Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

This is the presentation to follow conference paper of the same name. The adaptive compliant trailing edge (ACTE) flap experiment safety of flight requires that the flap to wing interface loads be sensed and monitored in real time to ensure that the wing structural load limits are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces will be monitored and each contains four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty one applied test load cases were developed using the predicted in-flight loads for the ACTE experiment.

strain gage calibration↗

kasacrgridppi.c1

This datastream is made by kasacrgridppi VAP. It has (time, Y, X) gridded Ka-band PPI radar data, using nearest neighbor algorithm, with calibrated (.b1) input. This datastream is very similar to kasacrgridrhi, with the output grid changed from (time, height, h_distance) to (time, Y, X). output c1 level data use calibrated b1 data as input.

54 ENVIRONMENTAL SCIENCES↗

Factors That Influence Variability in Stress-Drop Measurements Using Spectral Decomposition and Spectral-Ratio Methods for the 2019 Ridgecrest Earthquake Sequence

Stress drop is a fundamental parameter related to earthquake source physics, but is hard to measure accurately. To better understand how different factors influence stress-drop measurements, we compare two different methods using the Ridgecrest stress-drop validation data set: spectral decomposition (SD) and spectral ratio (SR), each with different processing options. Here, we also examine the influence of spectral complexity on source parameter measurement. Applying the SD method, we find that frequency bandwidth and time-window length could influence spectral magnitude calibration, while depth-dependent attenuation is important to correctly map stress-drop variations. For the SR method, we find that the selected source model has limited influence on the measurements; however, the Boatwright model tends to produce smaller standard deviation and larger magnitude dependence than the Brune model. Variance reduction threshold, frequency bandwidth, and time-window length, if chosen within an appropriate parameter range, have limited influence on source parameter measurement. For both methods, wave type, attenuation correction, and spectral complexity strongly influence the result. The scale factor that quantifies the magnitude dependence of stress drop show large variations with different processing options, and earthquakes with complex source spectra deviating from the Brune-type source models tend to have larger scale factor than earthquakes without complexity. Based on these detailed comparisons, we make a few specific suggestions for data processing workflows that could help future studies of source parameters and interpretations.

58 GEOSCIENCES↗

Design and characterization of a prototype divertor viewing infrared video bolometer for NSTX-U

The InfraRed Video Bolometer (IRVB) is a powerful tool to measure radiated power in magnetically confined plasmas due to its ability to obtain 2D images of plasma emission using a technique that is compatible with the fusion nuclear environment. A prototype IRVB has been developed and installed on NSTX-U to view the lower divertor. The IRVB is a pinhole camera which images radiation from the plasma onto a 2.5 μm thick, 9 × 7 cm{sup 2} Pt foil and monitors the resulting spatio-temporal temperature evolution using an IR camera. The power flux incident on the foil is calculated by solving the 2D+time heat diffusion equation, using the foil’s calibrated thermal properties. An optimized, high frame rate IRVB, is quantitatively compared to results from a resistive bolometer on the bench using a modulated 405 nm laser beam with variable power density and square wave modulation from 0.2 Hz to 250 Hz. The design of the NSTX-U system and benchtop characterization are presented where signal-to-noise ratios are assessed using three different IR cameras: FLIR A655sc, FLIR A6751sc, and SBF-161. The sensitivity of the IRVB equipped with the SBF-161 camera is found to be high enough to measure radiation features in the NSTX-U lower divertor as estimated using SOLPS modeling. The optimized IRVB has a frame rate up to 50 Hz, high enough to distinguish radiation during edge-localized-modes (ELMs) from that between ELMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Dimensional Calibration of Impact Dynamic Models

NASA Langley, under the Subsonic Rotary Wing Program, recently completed two helicopter tests in support of an in-house effort to study crashworthiness. As part of this effort, work is on-going to investigate model calibration approaches and calibration metrics for impact dynamics models. Model calibration of impact dynamics problems has traditionally assessed model adequacy by comparing time histories from analytical predictions to test at only a few critical locations. Although this approach provides for a direct measure of the model predictive capability, overall system behavior is only qualitatively assessed using full vehicle animations. In order to understand the spatial and temporal relationships of impact loads as they migrate throughout the structure, a more quantitative approach is needed. In this work impact shapes derived from simulated time history data are used to recommend sensor placement and to assess model adequacy using time based metrics and orthogonality multi-dimensional metrics. An approach for model calibration is presented that includes metric definitions, uncertainty bounds, parameter sensitivity, and numerical optimization to estimate parameters to reconcile test with analysis. The process is illustrated using simulated experiment data.

Horta, Lucas G.↗

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.↗

ARCSTONE: Calibration of Lunar Spectral Reflectance from Space

Detecting and improving the scientific understanding of global trends in complex Earth systems, such as climate, increasingly depends on assimilating datasets from multiple instruments and platforms over decadal timescales. Calibration accuracy, stability, and inter-consistency among different instruments are key to developing reliable composite data records from sensors in low Earth and geostationary orbits, but achieving sufficiently low uncertainties for these performance metrics poses a significant challenge. Space-borne instruments commonly carry on-board references for calibration at various wavelengths, but these increase mass and mission complexity, and are subject to degradation in the space environment. The Moon can be considered a natural solar diffuser which can be observed as a calibration target by most spaceborne Earth-observing instruments. Since the lunar surface reflectance is effectively time-invariant, establishing the Moon as a high-accuracy calibration reference enables broad inter-calibration opportunities even between temporally non-overlapping instruments and provides an exo-atmospheric absolute radiometric standard. The ARCSTONE mission goal is to establish the Moon as a reliable reference for high-accuracy on-orbit calibration in the visible and near-infrared spectral region. The ARCSTONE instrument is a compact spectrometer, which will be packaged on a CubeSat intended for low Earth orbit. It will measure the lunar spectral reflectance with accuracy < 0.5% (k=1), sufficient to establish an SI-traceable absolute lunar calibration standard when referenced to the spectral solar irradiance across the 350 to 2300 nm spectral range. This lunar reference will help to enable high-accuracy absolute calibration and inter-calibration of past, current, and future Earth-observing sensors, meteorological imagers, and long-term climate monitoring satellite systems. The ARCSTONE team will present the development status of a full-spectral-range (FSR) instrument, the intended approach to calibration and characterization, and the planned path toward mission implementation.

calibration↗

ARCSTONE: Calibration of Lunar Spectral Reflectance from Space

Detecting and improving the scientific understanding of global trends in complex Earth systems, such as climate, increasingly depends on assimilating datasets from multiple instruments and platforms over decadal timescales. Calibration accuracy, stability, and inter-consistency among different instruments are key to developing reliable composite data records from sensors in low Earth and geostationary orbits, but achieving sufficiently low uncertainties for these performance metrics poses a significant challenge. Space-borne instruments commonly carry on-board references for calibration at various wavelengths, but these increase mass and mission complexity, and are subject to degradation in the space environment. The Moon can be considered a natural solar diffuser which can be observed as a calibration target by most spaceborne Earth-observing instruments. Since the lunar surface reflectance is effectively time-invariant, establishing the Moon as a high-accuracy calibration reference enables broad inter-calibration opportunities even between temporally non-overlapping instruments and provides an exo-atmospheric absolute radiometric standard. The ARCSTONE mission goal is to establish the Moon as a reliable reference for high-accuracy on-orbit calibration in the visible and near-infrared spectral region. The ARCSTONE instrument is a compact spectrometer, which will be packaged on a CubeSat intended for low Earth orbit. It will measure the lunar spectral reflectance with accuracy < 0.5% (k=1), sufficient to establish an SI-traceable absolute lunar calibration standard when referenced to the spectral solar irradiance across the 350 to 2300 nm spectral range. This lunar reference will help to enable high-accuracy absolute calibration and inter-calibration of past, current, and future Earth-observing sensors, meteorological imagers, and long-term climate monitoring satellite systems. The ARCSTONE team will present the development status of a full-spectral-range (FSR) instrument, the intended approach to calibration and characterization, and the planned path toward mission implementation.

Moon↗

Solar calibration of stellar rotation tracers

A study of the time variability of the disk-integrated solar magnetic flux, with a view to the behavior of emission-line intensity variations observed in lower main sequence stars, has determined that solar rotation modulation of the integrated flux is present in 75% of all rotations. For observing intervals of more than twice the lifetime of the features causing rotational modulation, the correct rotation period is identified in more than 90% of all cases. The optimum time for measuring rotational modulation is the decay phase of the activity cycle, and the solar rotation period is measured with an accuracy of a few percent. The lifetime of a rotational modulation period is approximately five rotations, and a sensitivity limit of Delta S= 0.005 is found for the Vaughan et al (1981) stellar rotation measures.

Labonte, B. J.↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Online Analysis of {gamma}-ray Sources with H.E.S.S

Some of the {gamma}-ray sources detected by the H.E.S.S. experiment display irregular, often flare-like emission behaviour. A method to detect these outbursts as fast as possible is highly desirable. At H.E.S.S., first results from an offline analysis of pre-calibrated data can be obtained on-site approximately one hour after run end. We present a development and implementation of online analysis software that performs calibration and analysis of data at the time they are being taken allowing for a fast confirmation of observational results and appropriate reaction by the on-site shift crew.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Hyperspectral Sun Photometer for Satellite Remote Sensing Data Radiometric Calibration and Atmospheric Aerosol Studies

A simple and cost-effective, hyperspectral sun photometer for radiometric vicarious remote sensing system calibration, air quality monitoring, and potentially in-situ planetary climatological studies, was developed. The device was constructed solely from off the shelf components and was designed to be easily deployable for support of short-term verification and validation data collects. This sun photometer not only provides the same data products as existing multi-band sun photometers, this device requires a simpler setup, less data acquisition time and allows for a more direct calibration approach. Fielding this instrument has also enabled Stennis Space Center (SSC) Applied Sciences Directorate personnel to cross calibrate existing sun photometers. This innovative research will position SSC personnel to perform air quality assessments in support of the NASA Applied Sciences Program's National Applications program element as well as to develop techniques to evaluate aerosols in a Martian or other planetary atmosphere.

Pagnutti, Mary↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ICESat-2 Pointing Calibration and Geolocation Performance

ICESat-2 science requirements are dependent on the accurate real-time pointing control (i.e. geolocation control) and post-processed geolocation knowledge of the laser altimeter surface returns. Pre-launch pointing alignment errors and post-launch pointing alignment variation result in large geolocation errors that must be calibrated on orbit. In addition, the changing sun-orbit geometry causes thermal-mechanical forced laser frame alignment variations at the orbit period and trends from days, weeks and months. Early mission analysis computed precise post-launch laser beam alignment calibration. The alignment calibration was uploaded to the spacecraft and enabled the pointing control performance to achieve 4.4 ± 6.0 m, a significant improvement over the 45 m (1 σ) mission requirement. Laser frame alignment calibrations are used to reduce the alignment bias and time variation, as well as the orbital variation contributions to geolocation knowledge error from 6 m to 1.7 m (1 σ). Relative beam alignment of the six beams is calibrated and shown to contribute between 0.5 ± 0.1 m and 2.4 ± 0.2 m of remaining geolocation knowledge error. Independent geolocation assessment based on comparison to high-resolution digital elevation models agrees well with the calibration geolocation error estimates. The analysis demonstrates the ICESat-2 mission is performing far better than its geolocation knowledge requirement of 6.5 m (1 σ) after the laser frame alignment bias variation and orbital variation calibrations have been applied. Remaining geolocation error is beam dependent and ranges from 2.5 m for beam 6 to 4.4 m for beam 2 (mean + 1 σ).

S. B. Luthcke↗

On-chop processing for the wave union TDC implemented in FPGA

The wave union TDC implemented in FPGA utilizes multiple measurement method to reach time resolution beyond the natural carry cell delay in FPGA. Lacking of analog compensation for bin width control available in ASIC, the wave union TDC takes the after-fact digital calibration approach. In addition to the temperature drift, non-uniformity of the carry chain structure in FPGA causes complicate differential nonlinearity pattern which imposes significant on-chip calibration challenge. In this paper, processing strategies for the wave union TDC are discussed. Actual implementations in low-cost FPGA with 20ps and 10ps RMS resolutions are also presented.

43 PARTICLE ACCELERATORS↗

Energy Reconstruction and Calibration of the MicroBooNE LArTPC

MicroBooNE uses a liquid argon time projection chamber (LArTPC) for simultaneous tracking and calorimetry. Neutrino oscillation experiments plan to use LArTPCs over the next several decades. A challenge for these current and future experiments lies in characterizing detector performance and reconstruction capabilities with thorough associated systematic uncertainties. This work includes updates related to LArTPC detector physics challenges by reviewing MicroBooNE’s recent publications on calorimetry and its applications. Highlights include discussions on signal processing, calorimetric calibration, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and performance characteristics of a prototype NBS/GPS receiver

The construction and performance characteristics of a low-cost, high-accuracy GPS C/A receiver are reviewed. The receiver takes advantage of a simultaneous common view of the same satellites, which could allow time transfer with accuracies on the order of 10 ns or less for baselines as large as 3000 km. Frequency can be measured to better than one part in 10 to the 14th. The software and the receiver are configured to be fully automatic with a Z80A microprocessor setting the amplitude for the lock loops of the receiver and setting the synthesizer with corrects for Doppler shift. The microprocessor can calibrate a 0.1 ns built-in time interval counter.

Davis, D. D.↗