Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comanche Helmet-Mounted Display Heading-Tape Simulation

The Aeroflightdynamics Directorate (AMRDEC) conducted a simulation to assess the performance associated with a Contact Analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a Compressed heading tape similar to that specified by the former Military Standard (MIL-STD) 1295. Six experienced pilots flew three modified Aeronautical Design Standards (ADS)-33 maneuvers (Hover Turn, Bob-up, Transient Turn) and a precision traffic pattern in the NASA Vertical Motion Simulator (VMS). Analysis of the pilot objective performance data and subjective handling qualities ratings (HQRs) showed the following: Compressed symbology in the Velocity Stabilization (VelStab) flight mode generally produced the most precise performances over Contact Analog symbology with respect to the heading, altitude, position, and time criteria specified for the maneuvers tested. VelStab outperformed the Automatic Flight Control System (AFCS) on all maneuvers achieving desired performance on most maneuvers for both symbol sets. Performance in the AFCS mode was generally desirable to adequate for heading and altitude and did not meet adequate standards for hover position and time for the Hover Turn and Bob-up maneuvers. VelStab and AFCS performance were nearly the same for the Transient Turn. Pilot comments concerning the Contact Analog heading-tape implementation were generally unfavorable in spite of the achieved levels of performance. HQRs showed Compressed symbology in the VelStab flight mode produced the lowest mean HQR, encompassing mixed ratings of satisfactory handling and needing improvement. All other symbology/flight-mode combinations yielded higher HQRs, which characterized opinions that deficiencies in aircraft handling due to HMD symbology would need improvement. Contact Analog heading tape and other symbology require improvement, especially when operating in the AFCS mode. NASA-TLX rated Compressed symbology in the VelStab flight mode as the least demanding on resources, closely followed by ratings for Contact Analog in the VelStab mode. In a similar pattern, TLX ratings for maneuvers completed in the AFCS mode yielded a higher level of resource demand with even slighter differences between Contact Analog and Compressed symbology sets. Further research should be conducted where objective data and subjective HQR ratings indicate a need for improvement. The areas requiring attention are those where the symbology implementation, the flight control system, or a combination of both caused workload to reach an objectionable level where adequate performance was either difficult to achieve or unachievable. These areas are clearly identified in this report. Symbology that received negative HQR comments by a majority of pilots should also be examined. The summary of pilot comments can be found in appendix A. Additional simulation trials should be considered to address the identified issues.

Turpin, Terry↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

A fine pointing system for the large space telescope

The large space telescope (LST) developed by NASA requires ultrahigh pointing stability within 0.0005 arc sec rms. A fine guidance system is proposed to body-point the entire spacecraft within this limit. The spacecraft is modeled as a rigid body having reaction wheel actuators and subject to gravitational and magnetic disturbance torques. The fine guidance sensor is cluttered with electronic noise. The disturbance accommodation standard deviation optimal controller (DASOC) is designed to be optimal with respect to the transient and the steady state response to noise, whereas the steady state response to deterministic external torques is exactly zero. Compared with conventional controllers, the fine guidance system with the DASOC offers as much as a factor of 30 improvement in pointing stability, resulting in an optimal performance of nearly 0.0001 arc sec rms. Thus, the required pointing stability can easily be obtained, and a large margin remains for the compensation of possibile deteriorations.

Schiehlen, W. O.↗

A stable RNA virus-based vector for citrus trees

Virus-based vectors are important tools in plant molecular biology and plant genomics. A number of vectors based on viruses that infect herbaceous plants are in use for expression or silencing of genes in plants as well as screening unknown sequences for function. Yet there is a need for useful virus-based vectors for woody plants, which demand much greater stability because of the longer time required for systemic infection and analysis. We examined several strategies to develop a Citrus tristeza virus (CTV)-based vector for transient expression of foreign genes in citrus trees using a green fluorescent protein (GFP) as a reporter. These strategies included substitution of the p13 open reading frame (ORF) by the ORF of GFP, construction of a self-processing fusion of GFP in-frame with the major coat protein (CP), or expression of the GFP ORF as an extra gene from a subgenomic (sg) mRNA controlled either by a duplicated CTV CP sgRNA controller element (CE) or an introduced heterologous CE of Beet yellows virus. Engineered vector constructs were examined for replication, encapsidation, GFP expression during multiple passages in protoplasts, and for their ability to infect, move, express GFP, and be maintained in citrus plants. The most successful vectors based on the 'add-a-gene' strategy have been unusually stable, continuing to produce GFP fluorescence after more than 4 years in citrus trees.

60 APPLIED LIFE SCIENCES↗

Quantifying the Ligand-Induced Triplet Energy Transfer Barrier in a Quantum Dot-Based Upconversion System

During photon upconversion, quantum dots (QDs) transfer energy to molecules in solution through a long ligand shell. This insulating ligand shell imparts colloidal stability at the expense of efficient photosensitization. For the first time, we quantify the barrier these aliphatic ligands pose for triplet energy transfer in solution. Using transient absorption spectroscopy, we experimentally measure a small damping coefficient of 0.027 Å −1 for a ligand exceeding 10 carbons in length. The dynamic nature of ligands in solution lowers the barrier to charge or energy transfer compared to organic thin films. In addition, we show that surface ligands shorter than 8 carbons in length allow direct energy transfer from the QD, bypassing the need for a transmitter ligand to mediate energy transfer, leading to a 6.9% upconversion quantum yield compared with 0.01% for ligands with 18 carbons. Furthermore, this experimentally derived insight will enable the design of efficient QD-based photosensitizers for catalysis and energy conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perturbative transport modeling of cold-pulse dynamics in Alcator C-Mod Ohmic plasmas

Perturbative transport experiments in magnetically confined plasmas have shown, for more than 20 years, that the injection of cold pulses at the plasma edge can trigger the increase of core temperature. Predictive heat transport simulations with the trapped gyro Landau fluid (TGLF) quasilinear transport model demonstrate that the increase of core temperature in some regimes, and lack thereof in other regimes, can be explained by a change in dominant linear micro-instability in Alcator C-Mod. The effect of density and plasma current on the cold pulse are well captured by TGLF, including the relative change in position of the temperature flex point as current density changes. Linear stability analysis of simulated density and current scans reveals a competition between trapped electron and ion temperature gradient modes as the main driver of the core transient response. Here these results further demonstrate that cold-pulse propagation and associated phenomenology in the cases studied are well explained within the local transport paradigm, without resorting to non-local effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tech-X contributions to the Center for Tokamak Transients (CTTS) Scientific Discovery through Advanced Computing (SciDAC) project (Final Report)

The Center for Tokamak Transients Simulations (CTTS) consists of computational plasma physicists, computer scientists, and applied mathematicians who are together developing and applying simulation software to improve our understanding of and ability to predict and control transient events in tokamak discharges, particularly those that lead to violent disruptions. We have major simulation activities concerning disruptions that are caused by violating ideal MHD stability criteria, vertical displacement events, resistive wall modes, and tearing modes. We are performing comprehensive modeling of disruption mitigation techniques, particularly by shattered pellet injection (SPI). The Center is built around two mature extended MHD codes: NIMROD and M3D-C1. These codes are being extended in a number of ways as required by the demands of disruption modeling, and are being optimized to work well for larger problem size and modern computer architectures as required to model tokamak plasmas with realistic parameters over the required timescales. The codes will be coupled to the FronTier code for state-of-the-art modeling of SPI. Validation with experimental data on DIII-D, NSTX, and JET is being facilitated by rigorous uncertainty quantification (UQ). The high-level objectives of the center are to: (1) Develop better understanding and improved predictive capability of when crossing a linear stability boundary will likely lead to a disruption, (2) Provide a tool for calculating vessel forces, both axisymmetric and non-axisymmetric, for worst case VDE and other disruptions in tokamaks, (3) Develop increased understanding and improved predictive capability for locked mode disruptions and how best to avoid them, (4) Develop, verify, and validate 3D models for disruption mitigation by shattered pellets that can be used to design and optimize a system for future tokamaks, and (5) Increase the efficiency and scalability of the M3D-C1 and NIMROD codes so that they can model disruptions in ITER scale devices using the most powerful DOE HPC hardware, and (6) Demonstrate code-coupling via FronTier coupling with NIMROD and M3D-C1 and by interfacing these codes within a WDM framework.

97 MATHEMATICS AND COMPUTING↗

Exploratory flight test of advanced piloted spacecraft - Circa 1963

The NASA early experimental program for parawing and lifting body spacecraft recovery concepts is discussed. Simple hand drawings, in-house construction, and crude drop tests were used in lieu of a thorough stress analysis. The parawing (parasev) was controlled by manually shifting the center of gravity with respect to the center of pressure; the craft would take off while being towed at 40 KIAS. The M-2 lifting body was originally constructed with a 3/32 in. mahogany skin by a glider manufacturer and employed general aviation aircraft nose and main wheel assemblies. A minimum altitude of 200 ft was found acceptable for release of the parasev, allowing the pilot time to adjust for transients incurred at the tow release. A small landing assist rocket was furnished for the M-2/F-2 and X-24A lifting bodies to enhance stability, and landings at a maximum lift/drag ratio of 2.8 were successfully completed. The data gained were eventually applied in the development of the Shuttle.

Thompson, M. O.↗

The Origins Space Telescope Integration and Testing

This paper describes the plans, flows, key facilities, test beds, pathfinders, simulators and ground support equipment that could be used to fully integrate, functionally test and qualify the Origins Space Telescope (Origins). The Origins Observatory consists of the Spacecraft Bus Module (SBM) and the Cryogenic Payload Module (CPM), which comprises the telescope and three science instruments. The telescope is a Three Mirror Anastigmat (TMA) and is composed of four mirrors: three with optical power (the elliptical primary, hyperbolic secondary, and elliptical tertiary mirrors) and a flat field-steering mirror (FSM). The three science instruments spanning the wavelength range 2.8 to 588 μm provide the powerful new spectroscopic and imaging capabilities required to achieve the scientific objectives. The Origins Survey Spectrometer (OSS) uses six gratings in parallel to take multi-beam spectra simultaneously across the 25 to 588 μm window through long slits enabling deep 3D extra-galactic surveys. The Far-IR Imager/Polarimeter (FIP) provides imaging and polarimetric measurement capabilities at 50 and 250 μm. Its fast mapping enables rapid follow-up of transient or variable sources and efficient monitoring campaigns. The Mid-Infrared Spectrometer (MISC-T) provides spectroscopy simultaneously over 2.8 to 20 μm with exquisite stability and precision (<5 ppm between 2.8 to 10 μm, <20 ppm between 11 to 20 μm). All the instruments are delivered for Integration and Test fully qualified and calibrated. The Integration and Test program implemented at each level of assembly is discussed as well as the separation of thermal vacuum testing between the hot and cold zones of the Observatory. Portions of this manuscript appear in the Origins Study Final Report.

Origins↗

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isolator Shock Train Response to Dual-Mode Scramjet Throttling-Like Forcing

Typical dual-mode scramjet designs employ an isolator component situated between the inlet and combustor. The isolator fluidically buffers the inlet from the combustor via the formation of a shock train, an interconnected series of shock-boundary layer interactions. The isolator is required during ramjet-engine operation and at the lower edges of the scramjet operational envelope. In an operational engine, transient behavior imposes fluidic dynamics due to attitude adjustments, combustor throttling, aberrant resonances within the combustor, etc. To accommodate these transients, the shock train adjusts on both temporal and spatial scales. Sufficiently large downstream pressure increases in the combustor play a critical role during unstart, whereby strong compression waves propagate upstream in the isolator to ultimately force the shock train out the inlet, if it cannot stabilize to the pressure increase. This critically reduces the engine mass flow rate, potentially causing a catastrophic reduction in thrust and loss of the vehicle. A nearly instantaneous unstart can, in principle, be predicted by a ratio of the normal shock pressure jump in an inviscid isolator. However, lower-magnitude perturbations, below this bound, also induce unstarts. Understanding the transient behavior inherent in unsteady isolator operation is critical to reducing safety margin in isolator length and refining engine control algorithms to improve engine performance. The Isolator Dynamics Research Lab (IDRL) is a cold-flow, direct-connect isolator facility ideal for assessing the fundamental fluid dynamics of shock trains. The internal flow of a scramjet isolator is modeled using a 2D, symmetric Mach 2.5 nozzle followed by a 695 mm long, 25.4x50.8 mm rectangular isolator test section. A blockage cone on a high-speed ball screw actuator downstream of the isolator is pulsed to simulate the throttling behavior in an operational combustor. Wall flush high-speed static pressure transducers detect the streamwise shock train within the isolator. Time delays between the onset of the throttling and the response motion of the shock train are analyzed to assess the controlling scales and parameters. From this analysis, the response time of the isolator shock train system is found to depend primarily on the isolator back pressure time-rate-of-change but quickly saturates to a maximum propagation speed along the isolator. These results inform dual-mode scramjet engine designers of the critical parameters and limits of an unstart resistant engine.

scramjet↗

Thermal Analysis of a Uranium Silicide Miniplate Irradiation Experiment

This paper outlines the thermal analysis for the irradiation of high density uranium-silicide (U3Si2 dispersed in an aluminum matrix and clad in aluminum) booster fuel for a Boosted Fast Flux Loop designed to provide fast neutron flux test capability in the ATR. The purpose of this experiment (designated as Gas Test Loop-1 [GTL-1]) is two-fold: (1) to assess the adequacy of the U3Si2/Al dispersion fuel and the aluminum alloy 6061 cladding, and (2) to verify stability of the fuel cladding boehmite pre-treatment at nominal power levels in the 430 to 615 W/cm2 (2.63 to 3.76 Btu/s•in2) range. The GTL-1 experiment relies on a difficult balance between achieving a high heat flux, yet keeping fuel centerline temperature below a specified maximum value throughout an entire operating cycle of the reactor. A detailed finite element model was constructed to calculate temperatures and heat flux levels and to reveal which experiment parameters place constraints on reactor operations. Analyses were performed to determine the bounding lobe power level at which the experiment could be safely irradiated, yet still provide meaningful data under nominal operating conditions. Then, simulations were conducted for nominal and bounding lobe power levels under steady-state and transient conditions with the experiment in the reactor. Reactivity changes due to a loss of commercial power with pump coast-down to emergency flow or a standard in-pile tube pump discharge break were evaluated. The time after shutdown for which the experiment can be adequately cooled by natural convection cooling was determined using a system thermal hydraulic model. An analysis was performed to establish the required in-reactor cooling time prior to removal of the experiment from the reactor. The inclusion of machining tolerances in the numerical model has a large effect on heat transfer.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A laboratory measurement of CCD photometric and dimensional stability

The sun exhibits periodic and quasi-periodic variability in its total luminosity, which provides information about its internal structure and dynamics. Variability ranges from a few minutes to many-year time scales, with amplitudes as small as a few ppm in the milliHz band. Extension of this analysis to a large sample of outer stars would be interesting: a panoramic detector such as a CCD could record many stars at once. To meet this objective, a ppm time-series differential precision is required. Laboratory CCD photometric measurements presented here are promising for such an instrument. Normalizing the response from a portion of the CCD area removes most of the individual-frame variability. When a trend attributed to a thermal transient in the CCD dewar is removed, the individual-frame photometric precision is about 0.0001, limited by photoelectron counting statistics. The time-series power spectrum is flat within the desired frequency domain. Analysis of the dimensional stability of the CCD within the same data set indicates better than ppm performance, when first-order bulk motion and magnification changes are removed.

Buffington, Andrew↗

Laser frequency stabilization by dual arm locking for LISA

The Laser Interferometer Space Antenna (LISA) will be the first dedicated space based gravitational wave detector. LISA will consist of a triangular formation of spacecraft, forming an interferometer with 5x10{sup 6} km long arms. Annual length variations of the interferometer arms prevent exact laser frequency noise cancellation. Despite prestabilization to an optical cavity the expected frequency noise is many orders of magnitude larger than the required levels. Arm locking is a feedback control method that will further stabilize the laser frequency by referencing it to the 5x10{sup 6} km arms. Although the original arm locking scheme produced a substantial noise reduction, the technique suffered from slowly decaying start-up transients and excess noise at harmonic frequencies of the inverse round-trip time. Dual arm locking, presented here, improves on the original scheme by combining information from two interferometer arms for feedback control. Compared to conventional arm locking, dual arm locking exhibits significantly reduced start-up transients, no noise amplification at frequencies within the LISA signal band, and more than 50 fold improvement in noise suppression at low frequencies. In this article we present a detailed analysis of the dual arm locking control system and present simulation results showing a noise reduction of 10 000 at a frequency of 10 mHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved signal stability in inductively coupled plasma–atomic emission spectrometry through use of tandem spray chambers and surfactant addition

A search for causes of intermittent mid-term (about two hours) instability in emission signals from an inductively coupled plasma led to adoption of a tandem spray-chamber arrangement and subsequently to use of a surfactant (Triton X-100) to mitigate the remaining and newly found instabilities. Through a series of investigations, abrupt signal excursions in the tandem setup were traced to droplet coagulation and drainage inside the glass tube that connected the two spray chambers. However, the signal shifts were not the result of sample-solution release directly but rather to the influence of the underlying factors on plasma behavior. Experiments tailored to the study included not only examination of temporal signal behavior but also collection of long-term videos and measurement of radiofrequency characteristics of the plasma. The addition of a surfactant, Triton X-100, for signal-stability improvement is applicable not only to systems that employ tandem spray chambers but also to conventional single Scott-type chamber arrangements. Further, use of the surfactant was unsuccessful in overcoming “acid effects”, either of the steady-state or transient nature, and did not alter plasma background or analyte signals significantly.

Inductively coupled plasma–atomic emission spectro↗

Tunable Polaron Distortions Control the Extent of Halide Demixing in Lead Halide Perovskites

Photoinduced phase separation in mixed halide perovskites emerges from their electro-mechanical properties and high ionic conductivities, resulting in photoinduced I$^-$ rich charge carrier traps that diminish photovoltaic performance. Whether photoinduced phase separation stems from the polycrystalline microstructure or is an intrinsic material property has been an open question. We investigate the nanoscale photoinduced behavior of single-crystal mixed Br$^-$/I$^-$ methylammonium (MA + ) lead halide perovskite (MAPb(Br x I 1- x ) 3 ) nanoplates, eliminating effects from extended structural defects. Even in these nanoplates, we find that phase separation occurs, resulting in I$^-$rich clusters that are nucleated stochastically and stabilized by polarons. Upon lowering the electron-phonon coupling strength by partially exchanging MA + for Cs + , a phase-separated steady state is not reached, nevertheless transient I$^-$ clustering still occurs. Our results, supported by multiscale modeling, demonstrate that photoinduced phase separation is an intrinsic property of mixed halide perovskites, the extent and dynamics of which depends on the electron-phonon coupling strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Deacylation Mechanism of AmpC [beta]-Lactamase at Ultrahigh Resolution

{beta}-Lactamases confer bacterial resistance to {beta}-lactam antibiotics, such as penicillins. The characteristic class C {beta}-lactamase AmpC catalyzes the reaction with several key residues including Ser64, Tyr150, and Lys67. Here, we describe a 1.07 {angstrom} X-ray crystallographic structure of AmpC {beta}-lactamase in complex with a boronic acid deacylation transition-state analogue. The high quality of the electron density map allows the determination of many proton positions. The proton on the Tyr150 hydroxyl group is clearly visible and is donated to the boronic oxygen mimicking the deacylation water. Meanwhile, Lys67 hydrogen bonds with Ser64O{gamma}, Asn152O{delta}1, and the backbone oxygen of Ala220. This suggests that this residue is positively charged and has relinquished the hydrogen bond with Tyr150 observed in acyl-enzyme complex structures. Together with previous biochemical and NMR studies, these observations indicate that Tyr150 is protonated throughout the reaction coordinate, disfavoring mechanisms that involve a stable tyrosinate as the general base for deacylation. Rather, the hydroxyl of Tyr150 appears to be well positioned to electrostatically stabilize the negative charge buildup in the tetrahedral high-energy intermediate. This structure, in itself, appears consistent with a mechanism involving either Tyr150 acting as a transient catalytic base in conjunction with a neutral Lys67 or the lactam nitrogen as the general base. Whereas mutagenesis studies suggest that Lys67 may be replaced by an arginine, disfavoring the conjugate base mechanism, distinguishing between these two hypotheses may ultimately depend on direct determination of the pKa of Lys67 along the reaction coordinate.

08 HYDROGEN↗