V&V for turbulent mixing in the intermediate asymptotic regime

Turbulent fluid flow interacts nonlinearly with a number of processes, including reactive flow (chemistry), radiation, and the transport of particles embedded in the flow. Subgrid scale modeling of these nonlinear processes is a major challenge to computational science. To this end, turbulent mixing of dissimilar fluids is a driver. Here we study validation issues for a class of turbulent mixing simulations. In previous work, we have obtained agreement between simulation and experiment. The present paper addresses a remaining issue, the role of meniscus related boundary effects for immiscible fluids in the validation process. Validation and even verification has been controversial for turbulent mixing flows, as commonly used numerical models are diffusive and the resulting numerical diffusion modifies the parameters of the problem and its solution. Additionally, numerical diffusion of concentration and temperature is well documented in the scientific literature for Eulerian simulations. Lagrangian simulations, which might appear to avoid this problem, are subject to mesh tangling, ensuing regridding and use of Arbitrary Lagrangian Eulerian codes to substitute for a pure Lagrangian algorithm. In practice, Lagrangian methods are potentially subject to the same numerical diffusion issues when used to study complex interface instabilities.

97 MATHEMATICS AND COMPUTING↗

Verification of maximum radial power peaking factor due to insertion of FPM-LEU target in the core of RSG-GAS reactor

Verification of Maximum Radial Power Peaking Factor due to insertion of FPM-LEU target in the core of RSG-GAS Reactor. Radial Power Peaking Factor in RSG-GAS Reactor is a very important parameter for the safety of RSG-GAS reactor during operation. Data of radial power peaking factor due to the insertion of Fission Product Molybdenum with Low Enriched Uranium (FPM-LEU) was reported by PRSG to BAPETEN through the Safety Analysis Report RSG-GAS for FPM-LEU target irradiation. In order to support the evaluation of the Safety Analysis Report incorporated in the submission, the assessment unit of BAPETEN is carrying out independent assessment in order to verify safety related parameters in the SAR including neutronic aspect. The work includes verification to the maximum radial power peaking factor change due to the insertion of FPM-LEU target in RSG-GAS Reactor by computational method using MCNP5and ORIGEN2. From the results of calculations, the new maximum value of the radial power peaking factor due to the insertion of FPM-LEU target is 1.27. The results of calculations in this study showed a smaller value than 1.4 the limit allowed in the SAR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Advanced Numerical Tools for the Nonlinear Seismic Analysis of Nuclear Systems

In the framework of Probabilistic Risk Assessment (PRA) of nuclear facilities, a rigorous dynamic characterization of all structural and non-structural components is of paramount concern. The common features of nuclear facilities lies in the combination of three characteristics: 1. low aspect ratio; 2. large mass; and 3. significant embedment in soil. These characteristics make the interaction between the structural system and the surrounding soil a key aspect to consider for seismic risk evaluations. The methodologies and numerical tools currently in use for simulating the seismic response of a nuclear facility with significant Soil Structure Interaction (SSI) date back to the 1970's and rely on a number of simplifying idealizations, mainly related to the characterization of the incident seismic waveforms, the assumption of linear-elastic behavior of the superstructures, and idealization of equivalent linear behavior of the supporting soils. Given this background and taking advantage of the substantial progress in computational mechanics in the last decades, the ongoing research aims at developing advanced numerical tools for the nonlinear, time history simulation of nuclear facilities. This translates into the availability of a robust nonlinear time-domain simulation tool that can accurately model the nonlinearities of coupled soil-structure systems, and whose development includes robust verification and validation. The work described herein is supported by the U.S. Department of Energy (DOE) and focuses on delivering the next-generation, high performance simulation tool in support of DOE needs and mission. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Xenon Oscillations via Point Kinetics

We all appreciate the special role Xenon-135 plays in reactor transients. Unless there is sufficient reactivity override, on shutdown a conventional reactor cannot immediately restart because of the buildup of strongly absorbing Xenon from Iodine decay and the absence of neutron flux to continue its elimination. We are also aware of how the flux imbalance in a large reactor core gives rise to Xenon induced power precession around the core in unpredictable ways. In addition, with regard to computational methods, we lack readily accessible numerical algorithms enabling reliable characterization of Xenon oscillations with simple models to explain this fundamentally important phenomenon. Nowhere is this more apparent than in the classroom. In this presentation, we first consider a new 12-element comprehensive decay model to Xenon and its corresponding numerical implementation and verification to establish a predictive model of Xenon buildup in a constant flux. We then follow with a reduced self-consistent flux model in an infinite reactor- a model not found in textbooks. This presentation should appeal to those interested in developing high order numerical methods for reactor transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dependency of EBT2 film calibration curve on postirradiation time

Purpose: The Ashland Inc. product EBT2 film model is a widely used quality assurance tool, especially for verification of 2-dimensional dose distributions. In general, the calibration film and the dose measurement film are irradiated, scanned, and calibrated at the same postirradiation time (PIT), 1-2 days after the films are irradiated. However, for a busy clinic or in some special situations, the PIT for the dose measurement film may be different from that of the calibration film. In this case, the measured dose will be incorrect. This paper proposed a film calibration method that includes the effect of PIT. Methods: The dose versus film optical density was fitted to a power function with three parameters. One of these parameters was PIT dependent, while the other two were found to be almost constant with a standard deviation of the mean less than 4%. The PIT-dependent parameter was fitted to another power function of PIT. The EBT2 film model was calibrated using the PDD method with 14 different PITs ranging from 1 h to 2 months. Ten of the fourteen PITs were used for finding the fitting parameters, and the other four were used for testing the model. Results: The verification test shows that the differences between the delivered doses and the film doses calculated with this modeling were mainly within 2% for delivered doses above 60 cGy, and the total uncertainties were generally under 5%. The errors and total uncertainties of film dose calculation were independent of the PIT using the proposed calibration procedure. However, the fitting uncertainty increased with decreasing dose or PIT, but stayed below 1.3% for this study. Conclusions: The EBT2 film dose can be modeled as a function of PIT. For the ease of routine calibration, five PITs were suggested to be used. It is recommended that two PITs be located in the fast developing period (1∼6 h), one in 1 ∼ 2 days, one around a week, and one around a month.

61 RADIATION PROTECTION AND DOSIMETRY↗

Global Identification of Previously Undetected Pre-Satellite-Era Tropical Cyclone Candidates in NOAA/CIRES Twentieth-Century Reanalysis Data

Prior to the satellite era, limited synoptic observation networks led to an indefinite number of tropical cyclones (TCs) remaining undetected. This period of decreased confidence in the TC climatological record includes the first two-thirds of the twentieth century. While prior studies found that this undersampling exists, disagreement regarding its magnitude has caused difficulties in interpreting multidecadal changes in TC activity. Previous research also demonstrated that reanalyses can be used to extend TC climatology, utilizing the NOAA/Cooperative Institute for Research in Environmental Sciences (CIRES) Twentieth-Century Reanalysis to manually identify previously unknown Atlantic Ocean basin potential TCs. This study expands the spatiotemporal scope of the earlier work by presenting a filtering algorithm that dramatically improves the efficiency with which candidate events are identified in the reanalysis. This algorithm was applied to all tropical basins for the years 1871–1979, resulting in the first quantitative and objective global TC candidate event counts for the decades prior to formal recordkeeping. Observational verification performed on a subset of these events indicates that the algorithm identifies potential missing TCs at a success rate approximating that of earlier work with a significant decrease in the amount of time required. Extrapolating these proportions to all of the candidate events identified suggests that this method may help to locate hundreds of previously unknown TCs worldwide for future study and cataloging. As such, the dataset produced by this research is a source of independent guidance for use in ongoing and future TC climatology revision efforts to produce a more complete historical record more quickly than with current methods.

54 ENVIRONMENTAL SCIENCES↗

Development and Validation of Multidimensional Models of Supercritical CO 2 Energy Conversion Systems for Nuclear Power Reactors

A general objective of this project was to develop, verify and validate mechanistic multidimensional models of local flow and heat transfer in supercritical carbon dioxide (S-CO 2 ) devices and systems, and to demonstrate the application of the new models to selected components of S-CO 2 nuclear energy transport systems. Both steady-state and time-dependent operating conditions have been investigated. The overall workscope consisted of the following three major parts: Development, testing and validation of a mechanistic model of forced-convection heat transfer in heated channels cooled using S-CO 2 at slightly supercritical pressures; Development, testing and verification/validation of a new model of the dynamics of closed- loop S-CO 2 heat transport systems; and, Formulation, testing and verification of a mechanistic model for the analysis of flow and pressure distribution in S-CO 2 compressors. The results of the work performed for the project have been documented in several publications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and preliminary verification of the 3D core neutronic code: COCO

As the recent blooming economic growth and following environmental concerns (China)) is proactively pushing forward nuclear power development and encouraging the tapping of clean energy. Under this situation, CGNPC, as one of the largest energy enterprises in China, is planning to develop its own nuclear related technology in order to support more and more nuclear plants either under construction or being operation. This paper introduces the recent progress in software development for CGNPC. The focus is placed on the physical models and preliminary verification results during the recent development of the 3D Core Neutronic Code: COCO. In the COCO code, the non-linear Green's function method is employed to calculate the neutron flux. In order to use the discontinuity factor, the Neumann (second kind) boundary condition is utilized in the Green's function nodal method. Additionally, the COCO code also includes the necessary physical models, e.g. single-channel thermal-hydraulic module, burnup module, pin power reconstruction module and cross-section interpolation module. The preliminary verification result shows that the COCO code is sufficient for reactor core design and analysis for pressurized water reactor (PWR). (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quality Assurance of Multifractionated Pelvic Interstitial Brachytherapy for Postoperative Recurrences of Cervical Cancers: A Prospective Study

Purpose: To evaluate three-dimensional needle displacements during multifractionated interstitial brachytherapy (BT) for cervical cancers. Methods and Materials: Patients scheduled to undergo pelvic interstitial BT for postoperative and or postradiation vault recurrences were included from November 2009 to December 2010. All procedures were performed under spinal anesthesia. Postprocedure BT planning CT scans were obtained with patients in supine position with arms on the chest (interslice thickness of 3 mm). Thereafter, verification CT was repeated at every alternate fraction. Needle displacements were measured in reference to a relocatable bony point. The mean cranial, caudal, anteroposterior, and mediolateral displacements were recorded. Statistical significance of mean interfraction displacements was evaluated with Wilcoxon Test. Results: Twenty patients were included. Seventeen received boost BT (20 Gy/5 fractions/3 days) after external radiation, three received radical BT alone (36 Gy/9 fractions/5-8 days). An average of three scans (range, 2-3) were available per patient, and 357 needle displacements were analyzed. For the entire study cohort, the average of mean needle displacement was 2.5 mm (range, 0-7.4), 17.4 mm (range, 0-27.9), 1.7 mm (range, 0-6.7), 2.1 mm (range, 0-9.5), 1.7 mm (range, 0-9.3), and 0.6 mm (range, 0-7.8) in cranial, caudal, anterior, posterior, right, and left directions, respectively. The mean displacement in the caudal direction was higher between Days 1 and 2 than that between Days 2 and 3 (13.4 mm vs. 3.8 mm; p = 0.01). The average caudal displacements were no different between reirradiation and boost cohort (15.2 vs. 17.8 mm). Conclusions: Clinically significant caudal displacements occur during multifractionated pelvic brachytherapy. Optimal margins need to be incorporated while preplanning brachytherapy to account for interfraction displacements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involute Working Group – FSI Analysis of Fuel Plates Using Finite Volume and Finite Element Methods

The three involute plate research reactors RHF, HFIR, and FRM II have expressed an interest in using computational software to carry their steady-state safety analysis. Since these tools represent a significant departure from the methods used currently (one-dimensional), the acceptability of the new approach by regulators requires thorough verification and validation of these tools. Therefore, Argonne National Laboratory and the three involute-plate reactors formed an informal group called the Involute Working Group aiming at qualifying computational tools to perform steady-state safety analysis. The present report focuses on a comparison of finite volume and finite element methods to model solids in fluid-structure interaction problems with the goal to estimate the coolant flow-induced fuel plate deflections obtained with the two methods. The finite volume method will be obsoleted in STARCCM+ by the end of 2021, nevertheless, this evaluation is important because the method was used by ANL researchers to model the response of the fuel plates, despite its drawbacks, which are discussed in the report. It was essential to check how those estimates compare to the results obtained with the finite element method that is considered superior for structural analysis. Various geometries, i.e., flat, cylindrical and circle-involute fuel plates, as well as coolant flow speed, were considered. The comparison shows that, independently of the plate geometry, the finite volume method significantly underestimates the deflection as compared to finite element method for coarser meshes. When the discretization is developed as a result of a mesh sensitivity study using finite element method, the result obtained using finite volume method can be a few times smaller than the corresponding finite element method solution. A code-to-code comparison , between STAR-CCM+ and LS-DYNA was included in the analysis. Within the LS-DYNA models, two types of finite element formulations were used: solid and shell finite elements. Mesh sensitivity study showed that both approaches converge to a similar value that was obtained with STAR-CCM+ finite element solver. The evaluation of the computational solvers was extended by adding two benchmark cases from the STAR-CCM+ Verification Suite and presented in the Appendix A. The selected cases are: (1) bending of a cantilever beam under external load, and (2) cylindrical shell deformation analysis, known in the literature as ‘Scordelis-Lo roof’. The problems were solved with finite volume, and finite element methods, and the results confirmed the previously discussed findings. The analysis shows that the finite element solver is superior to the finite volume solver in terms of representation of model geometry and estimating the structural behavior of fuel plates. Depending on the ratio of the load to the flexibility of the plate, the finite volume solver can greatly under- or overestimate the structural response if a very carefully selected mesh is not used.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-C-201-02: Dosimetric Verification of SBRT with FFF-VMAT Using a 3-D Radiochromic/Optical-CT Dosimetry System

Purpose: With an increasing use of small field size and high dose rate irradiation in the advances of radiotherapy techniques, such as stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS), an in-depth quality assurance (QA) system is required. The purpose of this study is to investigate a high resolution optical CT-based 3D radiochromic dosimetry system for SBRT with intensity modulated radiotherapy (IMRT) and flattening filter free (FFF) volumetric modulated arc therapy (VMAT). Methods: Cylindrical PRESAGE radiochromic dosimeters of 10cm height and 11cm diameter were used to validate SBRT. Four external landmarks were placed on the surface of each dosimeter to define the isocenter of target. SBRT plans were delivered using a Varian TrueBeam™ linear accelerator (LINAC). Three validation plans, SBRT with IMRT (6MV 600MU/min), FFF-VMAT (10MV 2400MU/min), and mixed FFF-VMAT (6MV 1400MU/min, 10MV 2400MU/min), were delivered to the PRESAGE dosimeters. Each irradiated PRESAGE dosimeter was scanned using a single laser beam optical CT scanner and reconstructed with a 1mm × 1mm high spatial resolution. The comparison of measured dose distributions of irradiated PRESAGE dosimeters to those calculated by Pinnacle{sup 3} treatment planning system (TPS) were performed with a 10% dose threshold, 3% dose difference (DD), and 3mm distance-to-agreement (DTA) Gamma criteria. Results: The average pass rates for the gamma comparisons between PRESAGE and Pinnacle{sup 3} in the transverse, sagittal, coronal planes were 94.6%, 95.9%, and 96.4% for SBRT with IMRT, FFF-VMAT, and mixed FFF-VMAT plans, respectively. A good agreement of the isodose distributions of those comparisons were shown at the isodose lines 50%, 70%, 80%, 90% and 98%. Conclusion: This study demonstrates the feasibility of the high resolution optical CT-based 3D radiochromic dosimetry system for validation of SBRT with IMRT and FFF-VMAT. This dosimetry system offers higher precision QA with 3D dose information for small beams compared to what is currently available.

60 APPLIED LIFE SCIENCES↗

A framework for collaborative review of candidate events in high data rate streams: The V-FASTR experiment as a case study

“Fast radio transients” are defined here as bright millisecond pulses of radio-frequency energy. These short-duration pulses can be produced by known objects such as pulsars or potentially by more exotic objects such as evaporating black holes. The identification and verification of such an event would be of great scientific value. This is one major goal of the Very Long Baseline Array (VLBA) Fast Transient Experiment (V-FASTR), a software-based detection system installed at the VLBA. V-FASTR uses a “commensal” (piggy-back) approach, analyzing all array data continually during routine VLBA observations and identifying candidate fast transient events. Raw data can be stored from a buffer memory, which enables a comprehensive off-line analysis. This is invaluable for validating the astrophysical origin of any detection. Candidates discovered by the automatic system must be reviewed each day by analysts to identify any promising signals that warrant a more in-depth investigation. To support the timely analysis of fast transient detection candidates by V-FASTR scientists, we have developed a metadata-driven, collaborative candidate review framework. The framework consists of a software pipeline for metadata processing composed of both open source software components and project-specific code written expressly to extract and catalog metadata from the incoming V-FASTR data products, and a web-based data portal that facilitates browsing and inspection of the available metadata for candidate events extracted from the VLBA radio data.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal design of antireflection coating and experimental verification by plasma enhanced chemical vapor deposition in small displays

Conventional antireflection coating by thin films of quarter-wavelength thickness is limited by material selections and these films' refractive indices. The optimal design by non-quarter-wavelength thickness is presented in this study. A multilayer thin-film model is developed by the admittance loci to show that the two-layer thin film of SiN{sub x}/SiO{sub y} at 124/87 nm and three layer of SiN{sub x}/SiN{sub y}/SiO{sub z} at 58/84/83 nm can achieve average transmittances of 94.4% and 94.9%, respectively, on polymer, glass, and silicon substrates. The optimal design is validated by plasma enhanced chemical vapor deposition of N{sub 2}O/SiH{sub 4} and NH{sub 3}/SiH{sub 4} to achieve the desired optical constants. Application of the antireflection coating to a 4 in. liquid crystal display demonstrates that the transmittance is over 94%, the mean luminance can be increased by 25%, and the total reflection angle increased from 41 deg. to 58 deg.

36 MATERIALS SCIENCE↗

The verification and uncertainty quantification of surrogate models used for structural analysis

High fidelity modeling of complex systems can require large finite element models to capture the physics of interest. Typically these high-order models take an excessively long time to run. For important studies such as model validation and uncertainty quantification, where probabilistic measures of the response are required, a large number of simulations of the high fidelity model with different parameters are necessary. In addition, some environments, such as an extensive random vibration excitation, require a long simulation time to capture the entire event. A process that produces a highly efficient model from the original high order model is necessary to enable these analyses. These highly efficient models are referred to as surrogate models, for their purpose is to represent the main physics that is of importance, but decrease the computational burden. A critical aspect of any surrogate model is how faithfully the efficient model represents the original high-order model. This paper describes the process for verifying a surrogate model using response quantities of interest and quantifying the introduced uncertainties in the use of the surrogate model. This is done to help any analyst if they use any surrogate model; such has, Craig-Bampton Reduc tions, POD, etc.

Ross, Michael↗

New Whole-House Solutions Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.

air leakage↗

Numerical Uncertainties vs. Model Uncertainties in Two-phase Flow Simulations

In recent years, verification, validation and uncertainty quantification (VVUQ) have become a common practice in thermal-hydraulics analysis. In general, these activities deal with propagations of uncertainties in computer code simulations, e.g., through system analysis codes. However, most existing such activities in thermal-hydraulics analysis have been primarily focused on model uncertainties, while numerical uncertainties were largely overlooked. Numerical uncertainties (or numerical errors) can appear in many different forms, e.g., round-off error, statistical sampling error, and discretization error. As pointed out by Oberkampf and Roy, discretization error is usually the largest however the most difficult type of error to estimate reliably. In thermal-hydraulics analysis, especially two-phase flow simulations commonly encountered in reactor safety analysis, the lack of consideration on discretization error is mainly due to the difficulty in estimating them. Accurate estimations on discretization error require continuous mesh refinement and/or implementation of high-order numerical schemes in system analysis code, both of which are unfortunately difficult to achieve for existing codes. At first, it should be emphasized that mesh refinement (or mesh sensitivity study) is a well-understood concept in the thermal-hydraulics field. However, it is not commonly practiced for many reasons, e.g., lack of understanding on numerical errors by code users, consideration on computational cost, deteriorated numerical stability performance with refined meshes, and etc. Secondly, high-order (e.g., second-order) numerical schemes are simply unavailable in almost any existing system analysis code. Implementation of high-order numerical schemes in these codes is difficult, if not impossible, given the complexity of these codes. On the other hand, people tend to argue that numerical uncertainties (or discretization error as we have emphasized) are not as important as the commonly large uncertainties in two-phase flow models, e.g., closure correlations. As a result, nodalization is sometimes played unintentionally, or maybe intentionally, to match experimental data, which is referred as 'user effects' or 'compensating errors' in thermal-hydraulics community. Such a practice is highly criticized by Levy. In this work, we will at first build a computer code that incorporates both first-order and second-order numerical methods to solve the two-phase flow problems. The first-order method resembles the one used in many existing system analysis codes; and the second-order method works as the reference to estimate numerical errors. Numerical verifications on spatial discretization schemes will be presented in the form of mesh convergence study. It will also be demonstrated that, in practical scenarios, discretization errors can be as large as, or even larger than, model uncertainties via case studies.

42 ENGINEERING↗

SU-E-T-189: First Experimental Verification of the Accuracy of Absolute Dose Reconstruction From PET-CT Imaging of Yttrium 90 Microspheres

Purpose: In the past few years there have been numerous proposals for 3D dose reconstruction from the PET-CT imaging of patients undergoing radioembolization treatment of the liver with yttrium-90 microspheres. One of the most promising techniques uses convolution of the measured PET activity distribution with a pre-calculated Monte Carlo dose deposition kernel. The goal of the present study is to experimentally verify the accuracy of this method and to analyze the significance of various error sources. Methods: Optically stimulated luminescence detectors (OSLD) were used (NanoDot, Landauer) in this experiment. Two detectors were mounted on the central axis of a cylinder filled with water solution of yttrium-90 chloride. The total initial activity was 90mCi. The cylinder was inserted in a larger water phantom and scanned on a Siemens Biograph 16 Truepoint PET-CT scanner. Scans were performed daily over a period of 20 days to build a calibration curve for the measured absolute activity spanning 7 yttrium-90 half-lives. The OSLDs were mounted in the phantom for a predetermined period of time in order to record 2Gy dose. The measured dose was then compared to the dose reconstructed from the activity density at the location of each dosimeter. Results: Thorough error analysis of the dose reconstruction algorithm takes into account the uncertainties in the absolute PET activity, branching ratios, and nonlinearity of the calibration curve. The measured dose for 105-minute exposure on day 10 of the experiment was 219(11)cGy, while the reconstructed dose at the location of the detector was 215(47)cGy. Conclusion: We present the first experimental verification of the accuracy of the convolution algorithm for absolute dose reconstruction of yttrium-90 microspheres. The excellent agreement between the measured and calculated point doses will encourage the broad clinical adoption of the convolution-based dose reconstruction algorithm, making future quantitative dose/outcome studies possible.

60 APPLIED LIFE SCIENCES↗

Dosimetric verification of helical tomotherapy for total scalp irradiation

Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for a helical tomotherapy total scalp irradiation have been measured on an anthropomorphic phantom using radiochromic and radiographic film as well as a new skin dosimeter, the MOSkin. The superficial dose was found to be accurately calculated by the TomoTherapy planning system. This is in contrast to recent reports, probably due to a combination of the smaller dose grid resolution used in planning and this particular treatment primarily consisting of beamlets tangential to the scalp. The superficial dose was found to increase from 33.6 to 41.2 Gy and 36.0 to 42.0 Gy over the first 2 mm depth in the phantom in selected regions of the PTV, measured with radiochromic film. The prescription dose was 40 Gy. The superficial dose was at the prescription dose or higher in some regions due to the bolus effect of the thermoplastic head mask and the head rest used to aid treatment setup. It is suggested that to achieve the prescription dose at the surface ({<=}2 mm depth) bolus or a custom thermoplastic helmet is used.