Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A simplified model for thermal-wave cavity self-consistent measurement of thermal diffusivity

A simplified theoretical model was developed for the thermal-wave cavity (TWC) technique in this study. This model takes thermal radiation into account and can be employed for absolute measurements of the thermal diffusivity of gas and liquid samples without any knowledge of geometrical and thermal parameters of the components of the TWC. Using this model and cavity-length scans, thermal diffusivities of air and distilled water were accurately and precisely measured as (2.191 ± 0.004) × 10{sup −5} and (1.427 ± 0.009) × 10{sup −7} m{sup 2} s{sup −1}, respectively, in very good agreement with accepted literature values.

42 ENGINEERING↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XRFtomo

Based on [1], XRFtomo brings together a variety of image processing tools used for preparing, processing and reconstructing 3D renditions of samples imaged using a synchrotron-based x-ray fluorescence (XRF) microprobe or nanoprobe at the Advanced Photon Source (APS). This software bridges the gap between data acquisition and visualization by providing tools to adjust for misalignment in the imaging process and tools for running reconstructions[2], all with the use of a GUI or command line. XRFtomo accepts .h5 files processed through MAPS[3] and it outputs reconstructed cross-sections, projections, sinograms, metadata, and a configuration file with last-used parameters for rapid processing the next time the program is launched. These images serve as inputs for other 3D visualization software for generating volumetric renderings and animations.

Marin, Fabrico↗

Performance evaluation of a quasi-microscope for planetary landers

Spatial resolutions achieved with cameras on lunar and planetary landers have been limited to about 1 mm, whereas microscopes of the type proposed for such landers could have obtained resolutions of about 1 um but were never accepted because of their complexity and weight. The quasi-microscope evaluated in this paper could provide intermediate resolutions of about 10 um with relatively simple optics that would augment a camera, such as the Viking lander camera, without imposing special design requirements on the camera of limiting its field of view of the terrain. Images of natural particulate samples taken in black and white and in color show that grain size, shape, and texture are made visible for unconsolidated materials in a 50- to 500-um size range. Such information may provide broad outlines of planetary surface mineralogy and allow inferences to be made of grain origin and evolution. The mineralogical descriptions of single grains would be aided by the reflectance spectra that could, for example, be estimated from the six-channel multispectral data of the Viking lander camera.

Burcher, E. E.↗

Use of the Aromascan(TM) Instrument for Nonsubjective Evaluation of Rodent Spaceflight Hardware

This report describes the verification and utilization of the AromaScan(TM) (Hollis, NH) instrument for the ground-based evaluation of odor containment by various spaceflight habitats developed at NASA's Ames Research Center (ARC). The AromaScan(TM) instrument is an electronic odor detection system consisting of 32 polymer sensors that respond differentially to 10 different chemical groups present in an air sample. The AromaScan(TM) system also includes neural network software for constructing a database of known odors, against which an unknown odor can be compared. At present, the standard method for characterizing rodent odor containment during the development and testing of spaceflight hardware is the use of a human odor assessment panel. However, this can be a very time consuming and costly process, and the results are inherently subjective. The AromaScan(TM) system should produce more consistent and objective results, as well as a cost savings in the long term. To test and verify the AromaScan(TM) instrument, daily air samples will be collected from the exhaust port of rodent habitats, during experiment development tests, then injected into the instrument and used to create a database of recognizable odors. Human sniff tests will be performed in conjunction with the AromaScan(TM) analysis, and the results will be correlated. We will then teach the neural network to differentiate between an acceptable and an unacceptable odor profile, as defined by the human sniff test, and to be able to accurately identify an odor that would not pass a sniff panel. The results of our efforts will be to verify that the AromaScan(TM) system is a valuable alternative to human sniff panel assessments for the early iterative process of designing and testing rodent waste filters for spaceflight. Acceptance by a human panel will remain one of the final criteria for successful rodent habitat development.

Scribner, K. A.↗

Timing of Crystallisation of the Lunar Magma Ocean Constrained by the Oldest Zircon

The presently favoured concept for the early evolution of the Moon involves consolidation of debris from a giant impact of a Mars sized body with Earth forming a primitive Moon with a thick global layer of melt referred to as the Lunar Magma Ocean1 . It is widely accepted that many significant features observed on the Moon today are the result of crystallisation of this magma ocean. However, controversy exists over the precise timing and duration of the crystallisation process. Resolution of this problem depends on the establishment of precise and robust key crystallisation time points. We report a 4417 6 Myr old zircon in lunar breccia sample 72215,195, which provides a precisely determined younger limit for the solidification of the Lunar Magma Ocean. A model based on these data, together with the age of the Moon forming giant impact, defines an exponential time frame for crystallisation and suggests formation of anorthositic crust after about 80-85% of the magma ocean was solidified. In combination with other zircon ages the 4417 +/- 6 Myr age also suggests that the very small (less than a few per cent) residual portion of the magma ocean continued to solidify during the following 300-500 m.y.

Nemchin, A.↗

An Innovative Accident Tolerant LWR Fuel Rod Design Based on Uranium-Molybdenum Metal Alloy

The US Department of Energy is developing a uranium-molybdenum metal alloy Enhanced Accident Tolerant Fuel concept for Light Water Reactor applications that provides improved fuel performance during normal operation, anticipated operational occurrences, and postulated accidents. The high initial uranium atom density, the high thermal conductivity, and a low heat capacity permit a U-Mo-based fuel assembly to meet important design and safety requirements. These attributes also result in a fuel design that can satisfy increased fuel utilization demands and allow for improved accident tolerance in LWRs. This paper summarizes the results obtained from the on-going activities to; 1) evaluate the impact of the U-10wt%Mo thermal properties on operational and accident safety margins, 2) produce a triple extrusion of stainless steel cladding/niobium liner/U-10Mo fuel rod specimen and 3) test the high temperature water corrosion of rodlet samples containing a drilled hole in the cladding. Characterization of the cladding and liner thickness uniformity, microstructural features of the U-Mo gamma phase, and the metallurgical bond between the component materials will be presented. The results from corrosion testing will be discussed which yield insights into the resistance to attack by water ingress during high temperature water exposure for the triple extruded samples containing a drilled hole. These preliminary evaluations find that the U-10Mo fuel design concept has many beneficial features that can meet or improve conventional LWR fuel performance requirements under normal operation, AOOs, and postulated accidents. The viability of a deployable U-Mo fuel design hinges on demonstrating that fabrication processes and alloying additions can produce acceptable irradiation stability during normal operation and accident conditions and controlled metal-water reaction rates in the unlikely event of a cladding perforation. In the area of enhanced accident tolerance, a key objective is to establish that the lower stored energy of the U-Mo fuel design can provide the emergency core cooling systems the opportunity to maintain the reactor core in a coolable geometry following an accident.

Accident tolerance fuel↗

Mercury Recovery at Former Lithium Production Site at the Miramas in France - 18529

The former Lithium production facility located at Miramas in the South-East of France recently completed a 10-year program of process equipment removal, building demolition and soil remediation to recover mercury (Hg) that had been lost during operations at the site. After over 100 years ago chemical production, all production activities stopped in 2009, and immediately afterwards the clean-up project began. The main project focused on the demolition of all facilities and the decontamination of building materials and soil clean-up, with the goal of remediating the site for future industrial purposes. Prior to starting the decommissioning and clean-up work at the site a detailed site survey was conducted to identify the extent of the contamination of the site. After investigations into available technologies, the decision was made to install on-site treatment processes. This resulted in fewer residual environmental effects (trucking pollution, shipping containers, volume of materials, etc), a reduction in logistic complications, and, importantly, was cost effective compared to sending all untreated material to external processing facilities. This decision resulted in a need to optimize demolition waste management, while ensuring the highest clean-up and safety levels. A variety of treatment processes were investigated and compared and two technologies were finally selected and implemented. The first process was a 'thermal desorption unit (TDU),' which heated excavated soils and captured the vaporized mercury. The second was a washing process that was used to remove surface contamination. After the contaminated areas were excavated, materials were crushed, screened and sorted into different sizes, with each pile being routed to the appropriate process. The smaller-sized particles were treated in the TDU. A batch of around 12 MT was fed into a moisture evaporator and then into a mercury evaporator. The soils were then cooled, sampled to ensure no residual Hg contamination before being mixed with a binding agent, and returned to the excavation site. Larger materials with surface contamination were washed to remove the contamination. The liquid effluents were sent to a tank where the contaminated fines were removed, dried, pressed and sent for processing. If the washed, coarse materials failed to reach acceptable mercury levels, they were crushed again and sent to be treated in the TDU. The washing fluid was recycled for the next batch. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposal for a Sample Pilot Response Model

Regulations to establish operational and performance requirements for unmanned aircraft systems (UAS) are being developed by a consortium of government, industry and academic institutions. Those requirements will apply to the new detect and avoid (DAA) systems and other equipment necessary to integrate UAS with the National Airspace System (NAS) and are determined according to their contribution to the overall safety case for such an integration. In order to perform end-to-end verification and validation of DAA requirements, a committee accepted pilot response model is needed to emulate UAS pilots in closed-loop Monte Carlo fast-time simulations. This briefing focuses on background of the pilot model used in previous Airspace Concept Evaluation System studies, identification of strengths and weaknesses in that model, and proposals on model improvements. The briefing also looks to build consensus around a common architecture and assumptions for modeling the pilot for UAS DAA systems.

Santiago, Confesor↗

Small Angle X-Ray Scattering and Polymers

Polymers are some of the most versatile and useful materials on this planet. Properties of polymers are a result of their processing history, chemical makeup, and physical structure. Therefore, characterization is necessary to develop new polymer formulations and processes. Many established techniques for polymer characterization are destructive, and alternative methods that don’t destroy samples are in high demand. Thermal analysis techniques such as differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) yield important characteristic information for polymer samples while destroying the sample. Non-destructive strategies such as X ray diffraction (XRD) or small angle X-ray scattering (SAXS) can also find polymer characteristics while preserving a sample’s attributes. Sample preservation is desirable when investigating novel formulation and processing methods. SAXS analysis will be done on two different polymers: polyethylene, and a triblock copolymer. Using these two polymers allows for confidence between tests as polyethylene is very common, and well understood. Polyethylene analysis will be done first, and when methods have been refined so that the SAXS data matches accepted thermal analysis values for HDPE, there will be confidence to use the same analysis on block copolymers. Block copolymers remain relatively unexplored, so SAXS data will yield valuable information on their characteristics. Understanding the mechanical properties of these polymers is paramount to their application in upcycling, a process by which waste plastic can be converted into a higher value commodity. For this project, the upcycling process will be done via 3-dimensional (3d) printing.

36 MATERIALS SCIENCE↗

Evaluation of Various Depainting Processes on Mechanical Properties of 2024-T3 Aluminum Substrate

Alternate alkaline and neutral chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. These chemicals also, in general, meet corrosion acceptance criteria as specified in SAE MA 4872. Alternate acid chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. However, these chemicals do not generally meet corrosion acceptance criteria as specified in SAE MA 4872, especially in the areas of non-clad material performance and hydrogen embrittlement. Media blast methods reviewed in the study do not, in general, adversely affect fatigue performance or crack detectability of 2024-T3 substrate. Sodium bicarbonate stripping exhibited a tendency towards inhibiting crack detectability. These generalizations are based on a limited sample size and additional testing should be performed to characterize the response of specific substrates to specific processes.

McGill, P.↗

A simple way to measure daily lifestyle regularity

A brief diary instrument to quantify daily lifestyle regularity (SRM-5) is developed and compared with a much longer version of the instrument (SRM-17) described and used previously. Three studies are described. In Study 1, SRM-17 scores (2 weeks) were collected from a total of 293 healthy control subjects (both genders) aged between 19 and 92 years. Five items (1) Get out of bed, (2) First contact with another person, (3) Start work, housework or volunteer activities, (4) Have dinner, and (5) Go to bed were then selected from the 17 items and SRM-5 scores calculated as if these five items were the only ones collected. Comparisons were made with SRM-17 scores from the same subject-weeks, looking at correlations between the two SRM measures, and the effects of age and gender on lifestyle regularity as measured by the two instruments. In Study 2 this process was repeated in a group of 27 subjects who were in remission from unipolar depression after treatment with psychotherapy and who completed SRM-17 for at least 20 successive weeks. SRM-5 and SRM-17 scores were then correlated within an individual using time as the random variable, allowing an indication of how successful SRM-5 was in tracking changes in lifestyle regularity (within an individual) over time. In Study 3 an SRM-5 diary instrument was administered to 101 healthy control subjects (both genders, aged 20-59 years) for two successive weeks to obtain normative measures and to test for correlations with age and morningness. Measures of lifestyle regularity from SRM-5 correlated quite well (about 0.8) with those from SRM-17 both between subjects, and within-subjects over time. As a detector of irregularity as defined by SRM-17, the SRM-5 instrument showed acceptable values of kappa (0.69), sensitivity (74%) and specificity (95%). There were, however, differences in mean level, with SRM-5 scores being about 0.9 units [about one standard deviation (SD)] above SRM-17 scores from the same subject-weeks. SRM-5 scores also deviated more from a Gaussian distribution than did SRM-17 ones. In a study with a sample size of 101, the new SRM-5 instrument yielded scores with a mean of 4.11 and an SD of 1.13. Correlations between lifestyle regularity and age, and between lifestyle regularity and morningness appeared similar whether 5-item or 17-item SRM measures were used. When a gender difference in lifestyle regularity appeared, it was detected by both SRM-5 and SRM-17 measures.

Non-NASA Center↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineering a highly dispersed core@shell structure for efficient photocatalysis: A case study of ternary novel BiOI@MIL-88A(Fe)@g-C3N4 nanocomposite

Highlights: • Novel ternary BiOI@MIL-88A(Fe)@g-C{sub 3}N{sub 4} core@shell photocatalyst is reported. • Photocatalytic degradation mechanism of organic pollutants is investigated. • It is divulged that the photodegradation is increased by BiOI supporting. • Core@shell structure of MIL-88A(Fe)@g-C{sub 3}N{sub 4} causes high activity. • Strong visible light absorption and electron transfer improve activity. - Abstract: Ternary novel BiOI@MIL-88A(Fe)@g-C{sub 3}N{sub 4} nanocomposite with core@shell structure was successfully synthesized by hydrothermal method. Fabricated photocatalysts were characterized and results confirmed the formation of MIL-88A(Fe)@g-C{sub 3}N{sub 4} core@shell structure and subsequently BiOI decoration on the surface of MIL-88A(Fe)@g-C{sub 3}N{sub 4}. Photocatalytic performances of prepared samples were investigated for degradation of Acid Blue 92 (AB92), Rhodamine B (RhB) and phenol under visible irradiation. It is clearly demonstrated that the as-prepared ternary BiOI@MIL-88A(Fe)@g-C{sub 3}N{sub 4} composites exhibits exceptional visible-light photocatalytic activities for cationic, anionic as well as neutral pollutant molecules compared to the widely accepted outstanding g-C{sub 3}N{sub 4}. It is mainly proved that the exceptional photocatalytic efficiencies are comprehensively ascribed to the porous structure of MIL-88A(Fe)@g-C{sub 3}N{sub 4}, greatly promoted charge separation and introduced catalytic functions to the carrier-related redox reactions by decorating BiOI and coupling g-C{sub 3}N{sub 4}, to modulate holes and electrons. Additionally, studies performed using radical scavengers showed the main reactive species in the photocataytic reaction for all chemical pollutant degradation.

36 MATERIALS SCIENCE↗

Challenges in spatial metabolomics and proteomics for functional tissue unit and single-cell resolution

While transcriptomics is the most broadly applied technology for global spatial and single cell measurements in healthy and diseased tissues. Transcripts are often used as a proxy for protein and even metabolite measurements, but it has become commonly accepted that extrapolating this kind of information is a poor proxy and not a substitute for direct measurement. Within the last decade advanced developments of mass spectrometry-based assays have made these direct measurements not only possible, but routine. Where mass spectrometry has become an enabling technology, and various methods can now detect hundreds of metabolites and thousands of proteins from samples. Not only can this be performed within bulk measurements, but much effort has been directed into translating these measurements to single cells and tissues at cellular resolution. The information obtained from mass spectrometry is now able to trace metabolic events and decipher feedback loops across anatomical regions, connecting genetic and metabolic networks that define phenotypes. Herein, we will broadly overview developments in the field over the past decade, leading into several case studies which highlight the direct measurement of metabolites, proteins, and proteoforms from thinly sliced tissues. Much of this work is feasible due to multidisciplinary team science, and we offer brief perspective on paths forward and the challenges that persist with adoption and application of spatial omics.

59 BASIC BIOLOGICAL SCIENCES↗

Fabrication of Sr silicate buffer layer on Si(100) substrate by pulsed laser deposition using a SrO target

The authors fabricated 2 × 1 Sr-reconstructed Si(100) substrates using thin SrO layers, and used them to direct growth of crystalline perovskite oxide on Si. The SrO layers used to reconstruct the Si(100) substrates were grown by pulsed laser deposition from a SrO single crystal target, followed by postdeposition-annealing (PDA) of the SrO/Si(100) structure. In situ observations of reflective high-energy electron diffraction during PDA confirmed a 2 × 1 reconstruction of the Si surface and x-ray photoemission spectroscopy of the annealed samples confirmed the existence of Sr atoms in a silicate phase, which indicated that a 2 × 1 Sr-reconstructed Si surface was achieved. The optimal fabrication conditions were annealing at 720 °C for 1 min and an equivalent SrO layer thickness (ML{sub eq}) of 2.5 ML{sub eq}. The temperature condition was very narrow, at 720 ± 20 °C, for an acceptable product. Subsequently, the authors demonstrated the growth of crystalline SrTiO{sub 3} films on the 2 × 1 Sr-reconstructed Si(100) surfaces.

36 MATERIALS SCIENCE↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗