Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

60 APPLIED LIFE SCIENCES↗

Networked Gamma Radiation System for Tactical Deployment

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2" × 4" × 16" sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image quality of microcalcifications in digital breast tomosynthesis: Effects of projection-view distributions

Purpose: To analyze the effects of projection-view (PV) distribution on the contrast and spatial blurring of microcalcifications on the tomosynthesized slices (X-Y plane) and along the depth (Z) direction for the same radiation dose in digital breast tomosynthesis (DBT). Methods: A GE GEN2 prototype DBT system was used for acquisition of DBT scans. The system acquires PV images from 21 angles in 3 deg. increments over a {+-}30 deg. range. From these acquired PV images, the authors selected six subsets of PV images to simulate DBT of different angular ranges and angular increments. The number of PV images in each subset was fixed at 11 to simulate a constant total dose. These different PV distributions were subjectively divided into three categories: uniform group, nonuniform central group, and nonuniform extreme group with different angular ranges and angular increments. The simultaneous algebraic reconstruction technique (SART) was applied to each subset to reconstruct the DBT slices. A selective diffusion regularization method was employed to suppress noise. The image quality of microcalcifications in the reconstructed DBTs with different PV distributions was compared using the DBT scans of an American College of Radiology phantom and three human subjects. The contrast-to-noise ratio (CNR) and the full width at half maximum (FWHM) of the line profiles of microcalcifications within their in-focus DBT slices (parallel to detector plane) and the FWHMs of the interplane artifact spread function (ASF) in the Z-direction (perpendicular to detector plane) were used as image quality measures. Results: The results indicate that DBT acquired with a large angular range or, for an equal angular range,with a large fraction of PVs at large angles yielded superior ASF with smaller FWHM in the Z-direction. PV distributions with a narrow angular range or a large fraction of PVs at small angles had stronger interplane artifacts. In the X-Y focal planes, the effect of PV distributions on spatial blurring depended on the directions. In the X-direction (perpendicular to the chestwall), the normalized line profiles of the calcifications reconstructed with the different PV distributions were similar in terms of FWHM; the differences in the FWHMs between the different PV distributions were less than half a pixel. In the Y-direction (x-ray source motion), the normalized line profiles of the calcifications reconstructed with PVs acquired with a narrow angular range or a large fraction of PVs at small angles had smaller FWHMs and thus less blurring of the line profiles. In addition, PV distributions with a narrow angular range or a large fraction of PVs at small angles yielded slightly higher CNR than those with a wide angular range for small, subtle microcalcifications; however, PV distributions had no obvious effect on CNR for relatively large microcalcifications. Conclusions: PV distributions affect the image quality of DBT. The relative importance of the impact depends on the characteristics of the signal and the direction (perpendicular or parallel) relative to the direction of x-ray source motion. For a given number of PVs, the angular range and the distribution of the PVs affect the degree of in-plane and interplane blurring in opposite ways. The design of the scan parameters of tomosynthesis systems would require proper consideration of the characteristics of the signals of interest and the potential trade-off of the image quality of different types of signals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report: In-Situ TEM Observations of Degradation Mechanisms in Next-Generation High-Energy Density Lithium-Ion Battery Systems

This project originally sought to characterize nanoscale processes associated with the degradation of next-generation high energy density lithium-ion battery electrodes via in-situ transmission electron microscopy (TEM). The research also focused on developing the experimental techniques necessary for investigating electrochemical systems by in-situ transmission electron microscopy and providing a framework for understanding and quantifying electron beam effects that influence experimental results. In line with these goals, this project demonstrated and published the first in-situ TEM cycling of a Li-ion battery electrode in commercially relevant non-aqueous electrolyte: a technique subsequently adopted by a number of researchers in the field. Experiments performed on Sn anodes, demonstrated porosity evolution during Li dealloying as a mechanism for strain accommodation during the first cycle, and observed partially reversible crystalline to amorphous phase transitions associated with Li insertion and extraction in subsequent cycles. Complementary study of in-situ dealloying in a simple model, Au-Cu, was also performed. We also published the earliest quantitative measurements of electron beam effects in aqueous and non-aqueous liquids. Specifically, we utilized a model system to quantify the fraction of incident electron beam that contributed to charge transfer mediated reactions in non-aqueous liquid, since such liquids are primarily dose sensitive. We also quantified the evolution of model aqueous chemistries as a function of dose rate and chemical potential to better understand the reaction mechanisms active in liquids exposed to electron beams. The original project goals included the use of controlled environments to simulate different battery operational conditions. To aid such experiments, we developed new experimental apparatuses and techniques to perform in-situ liquid cell TEM under controlled temperature, including heating and cooling. We demonstrated this capability in aqueous systems; specifically understanding phase selection and solid-liquid interface interactions with particles during water crystallization and hydrothermal precipitation kinetics of ZnO. We also published the first demonstration of in-situ TEM based high-field (plasma) experiments and in-situ TEM of aqueous photochemistry, which demonstrated an previously unrecognized early growth mode transition during Au sputtering and delocalization of gas bubble nucleation during water splitting, respectively. In addition to the scientific results, this portion of the project greatly expanded the range of systems that can be characterized in realistic environments at the nanoscale via in-situ TEM. Unfortunately, commercial battery electrolytes are quite sensitive to electron dose. This limits the time of acquisition and/or the spatial resolution of the experiments. The same problem has been encountered in all subsequent publications in the field. The major problem, relative to the project original goals, is that long term cycling is challenging to characterize and the desired high resolution or analytical capabilities are limited. In line with our original goals to characterize battery reaction and degradation mechanisms under controlled electrochemical cycling, we developed a completely new type of Li-ion electrochemical cell that has been useful for both structural and analytical characterization. To date, we have demonstrated this platform for in-situ cycling of Li-ion batteries during scanning electron microscopy (SEM), Auger electron spectroscopy (AES), and x-ray photoelectron spectroscopy (XPS). In-situ AES has been found to be a quite powerful tool to characterize the chemical evolution of Li-ion batteries cycled in-situ and much of our effort in the final project period has focused on charactering Li-ion cathodes using the technique. We utilized in-situ SEM to propose a new mechanism for Li whisker/dendrite formation and show the importance of diffusion mediated stress relaxation in fracture of Sn anode particles. A combination of in-situ XPS and AES was used to clarify the CuO anode reaction mechanism. In the final project period, we have gained new insights into surface reactions occurring on cathodes at high voltage using in-situ AES. Specifically, we have discovered that many of the SEI formation reactions typically attributed to electrolyte decomposition are actually more fundamental to the electrode material surface thermodynamics in the presence of an arbitrary carbon source. These insights greatly affect how we understand and control surface degradation induced capacity fade at cathodes. Finally, we have made some effort to apply this novel in-situ platform to TEM characterization and believe this is a fruitful avenue for future research.

25 ENERGY STORAGE↗

A Novel Fast Helical 4D-CT Acquisition Technique to Generate Low-Noise Sorting Artifact–Free Images at User-Selected Breathing Phases

Purpose: To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Methods and Materials: Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. The tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Results: Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. Conclusions: The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact–free images at a patient dose similar to or less than current 4D-CT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Passive gamma analysis of the boiling-water-reactor assemblies

This research focused on the analysis of a set of stationary passive gamma measurements taken on the spent nuclear fuel assemblies from a boiling water reactor (BWR) using pulse height analysis data acquisition. The measurements were performed on 25 different BWR assemblies in 2014 at Sweden’s Central Interim Storage Facility for Spent Nuclear Fuel (Clab). This study was performed as part of the Next Generation of Safeguards Initiative–Spent Fuel project to research the application of nondestructive assay (NDA) to spent fuel assemblies. The NGSI–SF team is working to achieve the following technical goals more easily and efficiently than in the past using nondestructive assay (NDA) measurements of spent fuel assemblies: (1) verify the initial enrichment, burnup, and cooling time of facility declaration; (2) detect the diversion or replacement of pins, (3) estimate the plutonium mass, (4) estimate the decay heat, and (5) determine the reactivity of spent fuel assemblies. The final objective of this project is to quantify the capability of several integrated NDA instruments to meet the aforementioned goals using the combined signatures of neutrons, gamma rays, and heat. This report presents a selection of the measured data and summarizes an analysis of the results. Specifically, trends in the count rates measured for spectral lines from the following isotopes were analyzed as a function of the declared burnup and cooling time: 137 Cs, 154 Eu, 134Cs, and to a lesser extent, 106 Ru and 144 Ce. From these measured count rates, predictive algorithms were developed to enable the estimation of the burnup and cooling time. Furthermore, these algorithms were benchmarked on a set of assemblies not included in the standard assemblies set used by this research team.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Resolution Full-Field Structural Microscopy of the Voltage-Induced Filament Formation in VO 2 -Based Neuromorphic Devices

In order to make neuromorphic functions in memristive devices more efficient, information about the structural properties of filament formation at the micro- and mesoscopic scales is necessary. Despite extensive research on VO 2 , a key material due to its filament formation, local operando structural measurements remain challenging and often involve destructive specimen preparation and long rastering times, greatly limiting the scope of experimental studies. Utilizing dark-field X-ray microscopy (DFXM), a fullfield imaging modality, structural signatures of the filament formation process operando are revealed in VO 2 devices. DFXM experiments illustrate that rutile filaments contain isolated monoclinic clusters, indicating structural nonuniformity interior to the filament. The formation of the rutile phase beneath device electrodes was shown to precede filament development, followed by the formation of filament paths guided by nucleation sites within the device. Finally, a medium-term (<30 min) memory mechanism is observed in VO 2 , mediated by sites within the device gap that tend to switch at significantly lower voltages after electrical cycling, a tendency that persists through a brief thermal reset. High spatial resolution, large field-of-view, structure selectivity, and fast signal acquisition of DFXM provided insight into structural features of the filamentary channel and surrounding regions during voltage cycling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of diterpene synthase genes in the wild rice species Oryza brachyatha provides evolutionary insight into rice phytoalexin biosynthesis

Highlights: • Diterpene-type phtyoalexin oryzalexins are only found in Oryza sativa. • Copalyl diphosphate synthase (CPS) and kaurene synthase-like in turn make diterpenes. • A distant wild rice species O. brachyantha has different CPS activity to O. sativa. • CPS activity type determines the range of diterpene-type phytoalexins produced. • syn-CPS acquisition was necessary for evolution of oryzalexin S production in rice. Cultivated rice (Oryza sativa; Os) produces a variety of labdane-related diterpenoids; not only phytohormone gibberellins (GAs) but also phytoalexins for defense including phytocassanes, momilactones and oryzalexins. Their carbon skeleton diterpenes are constructed from geranylgeranyl diphosphate via ent-copalyl diphosphate (ent-CDP) or its diastereomer syn-CDP. These two-step reactions are successively catalyzed by homologs of the two diterpene synthases, ent-CDP synthase (ent-CPS) and ent-kaurene synthase (KS) that are responsible for the biosynthesis of GAs; e.g. OsCPS4 and OsKSL8 that are involved in the biosynthesis of oryzalexin S, a rice phytoalexin. Oryza brachyantha (Ob) is the most distant wild rice species from Os among the Oryza genus. We previously reported that the Ob genome contains ObCPS{sub 1}1g, ObKSL8-a, ObKSL8-b and ObKSL8-c for specialized metabolism at a locus similar to the OsKSL8 locus on chromosome 11. These Ob genes are closely related to OsCPS4 and OsKSL8, respectively. We herein characterize the diterpene synthase genes in Ob, using functional analyses and expression analysis. Recombinant OsKSL8 and ObKSL8-a showed the same in vitro function when syn-CDP or normal-CDP were used as substrates. Nonetheless, our results suggest that Ob produces normal-CDP-related diterpenoid phytoalexins, presumably via ObKSL8-a, while Os produces a syn-CDP-related phytoalexin, oryzalexin S, via OsKSL8. This difference must be due to the kinds of CPS that are present in each species; Os has OsCPS4 encoding syn-CPS, while Ob has ObCPS{sub 1}1g encoding normal-CPS. Thus, we propose the evolutionary history underlying oryzalexin S biosynthesis: the gain of a syn-CPS was a critical event allowing the biosynthesis of oryzalexin S.

60 APPLIED LIFE SCIENCES↗

TU-F-18C-03: X-Ray Scatter Correction in Breast CT: Advances and Patient Testing

Purpose: To further develop and perform patient testing of an x-ray scatter correction algorithm for dedicated breast computed tomography (BCT). Methods: A previously proposed algorithm for x-ray scatter signal reduction in BCT imaging was modified and tested with a phantom and on patients. A wireless electronic positioner system was designed and added to the BCT system that positions a tungsten plate in and out of the x-ray beam. The interpolation used by the algorithm was replaced with a radial basis function-based algorithm, with automated exclusion of non-valid sampled points due to patient motion or other factors. A 3D adaptive noise reduction filter was also introduced to reduce the impact of scatter quantum noise post-reconstruction. The impact on image quality of the improved algorithm was evaluated using a breast phantom and seven patient breasts, using quantitative metrics such signal difference (SD) and signal difference-to-noise ratios (SDNR) and qualitatively using image profiles. Results: The improvements in the algorithm resulted in a more robust interpolation step, with no introduction of image artifacts, especially at the imaged object boundaries, which was an issue in the previous implementation. Qualitative evaluation of the reconstructed slices and corresponding profiles show excellent homogeneity of both the background and the higher density features throughout the whole imaged object, as well as increased accuracy in the Hounsfield Units (HU) values of the tissues. Profiles also demonstrate substantial increase in both SD and SDNR between glandular and adipose regions compared to both the uncorrected and system-corrected images. Conclusion: The improved scatter correction algorithm can be reliably used during patient BCT acquisitions with no introduction of artifacts, resulting in substantial improvement in image quality. Its impact on actual clinical performance needs to be evaluated in the future. Research Agreement, Koning Corp., Hologic Inc., Barco Corp Consultant Agreement, Fujifilm Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-C-17A-06: A Hardware Implementation and Evaluation of Robotic SPECT: Toward Molecular Imaging Onboard Radiation Therapy Machines

Purpose: To construct a robotic SPECT system and demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch. The system has potential for on-board functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was developed utilizing a Digirad 2020tc detector and a KUKA KR150-L110 robot. An imaging study was performed with the PET CT Phantom, which includes 5 spheres: 10, 13, 17, 22 and 28 mm in diameter. Sphere-tobackground concentration ratio was 6:1 of Tc99m. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single pinhole collimator. The robotic system navigated the detector tracing the flat-top table to maintain the closest possible proximity to the phantom. For image reconstruction, detector trajectories were described by six parameters: radius-of-rotation, x and z detector shifts, and detector rotation θ, tilt ϕ and twist γ. These six parameters were obtained from the robotic system by calibrating the robot base and tool coordinates. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector-to-COR (center-ofrotation) distance. In acquisitions with background at 1/6th sphere activity concentration, photopeak contamination was heavy, yet the 17, 22, and 28 mm diameter spheres were readily observed with the parallel hole imaging, and the single, targeted sphere (28 mm diameter) was readily observed in the pinhole region-of-interest (ROI) imaging. Conclusion: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frame could be an effective means to estimate detector pose for use in SPECT image reconstruction. PHS/NIH/NCI grant R21-CA156390-01A1.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Kriging-Based Approach to Autonomous Experimentation with Applications to X-Ray Scattering

Abstract Modern scientific instruments are acquiring data at ever-increasing rates, leading to an exponential increase in the size of data sets. Taking full advantage of these acquisition rates will require corresponding advancements in the speed and efficiency of data analytics and experimental control. A significant step forward would come from automatic decision-making methods that enable scientific instruments to autonomously explore scientific problems—that is, to intelligently explore parameter spaces without human intervention, selecting high-value measurements to perform based on the continually growing experimental data set. Here, we develop such an autonomous decision-making algorithm that is physics-agnostic, generalizable, and operates in an abstract multi-dimensional parameter space. Our approach relies on constructing a surrogate model that fits and interpolates the available experimental data, and is continuously refined as more data is gathered. The distribution and correlation of the data is used to generate a corresponding uncertainty across the surrogate model. By suggesting follow-up measurements in regions of greatest uncertainty, the algorithm maximally increases knowledge with each added measurement. This procedure is applied repeatedly, with the algorithm iteratively reducing model error and thus efficiently sampling the parameter space with each new measurement that it requests. We validate the method using synthetic data, demonstrating that it converges to faithful replica of test functions more rapidly than competing methods, and demonstrate the viability of the approach in an experimental context by using it to direct autonomous small-angle (SAXS) and grazing-incidence small-angle (GISAXS) x-ray scattering experiments.

36 MATERIALS SCIENCE↗

Temporal Gating of Synaptic Competition in the Amygdala by Cannabinoid Receptor Activation

Abstract The acquisition of fear memories involves plasticity of the thalamic and cortical pathways to the lateral amygdala (LA). In turn, the maintenance of synaptic plasticity requires the interplay between input-specific synaptic tags and the allocation of plasticity-related proteins. Based on this interplay, weakly activated synapses can express long-lasting forms of synaptic plasticity by cooperating with strongly activated synapses. Increasing the number of activated synapses can shift cooperation to competition. Synaptic cooperation and competition can determine whether two events, separated in time, are associated or whether a particular event is selected for storage. The rules that determine whether synapses cooperate or compete are unknown. We found that synaptic cooperation and competition, in the LA, are determined by the temporal sequence of cortical and thalamic stimulation and that the strength of the synaptic tag is modulated by the endocannabinoid signaling. This modulation is particularly effective in thalamic synapses, supporting a critical role of endocannabinoids in restricting thalamic plasticity. Also, we found that the availability of synaptic proteins is activity-dependent, shifting competition to cooperation. Our data present the first evidence that presynaptic modulation of synaptic activation, by the cannabinoid signaling, functions as a temporal gating mechanism limiting synaptic cooperation and competition.

Madeira, Natália↗

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

WE-EF-207-07: Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)

Purpose: Conventional dual energy CT (DECT) reconstructs CT and basis material images from two full-size projection datasets with different energy spectra. To relax the data requirement, we propose an iterative DECT reconstruction algorithm using one full scan and a second sparse-view scan by utilizing redundant structural information of the same object acquired at two different energies. Methods: We first reconstruct a full-scan CT image using filtered-backprojection (FBP) algorithm. The material similarities of each pixel with other pixels are calculated by an exponential function about pixel value differences. We assume that the material similarities of pixels remains in the second CT scan, although pixel values may vary. An iterative method is designed to reconstruct the second CT image from reduced projections. Under the data fidelity constraint, the algorithm minimizes the L2 norm of the difference between pixel value and its estimation, which is the average of other pixel values weighted by their similarities. The proposed algorithm, referred to as structure preserving iterative reconstruction (SPIR), is evaluated on physical phantoms. Results: On the Catphan600 phantom, SPIR-based DECT method with a second 10-view scan reduces the noise standard deviation of a full-scan FBP CT reconstruction by a factor of 4 with well-maintained spatial resolution, while iterative reconstruction using total-variation regularization (TVR) degrades the spatial resolution at the same noise level. The proposed method achieves less than 1% measurement difference on electron density map compared with the conventional two-full-scan DECT. On an anthropomorphic pediatric phantom, our method successfully reconstructs the complicated vertebra structures and decomposes bone and soft tissue. Conclusion: We develop an effective method to reduce the number of views and therefore data acquisition in DECT. We show that SPIR-based DECT using one full scan and a second 10-view scan can provide high-quality DECT images and accurate electron density maps as conventional two-full-scan DECT.

60 APPLIED LIFE SCIENCES↗

MO-DE-207B-11: Reliability of PET/CT Radiomics Features in Functional and Morphological Components of NSCLC Lesions: A Repeatability Analysis in a Prospective Multicenter Cohort

Purpose: The goal of this study was to evaluate the repeatability of radiomics features (intensity, shape and heterogeneity) in both PET and low-dose CT components of test-retest FDG-PET/CT images in a prospective multicenter cohort of 74 NSCLC patients from ACRIN 6678 and a similar Merck trial. Methods: Seventy-four patients with stage III-IV NCSLC were prospectively included. The primary tumor and up to 3 additional lesions per patient were analyzed. The Fuzzy Locally Adaptive Bayesian algorithm was used to automatically delineate metabolically active volume (MAV) in PET. The 3D SlicerTM software was exploited to delineate anatomical volumes (AV) in CT. Ten intensity first-order features, as well as 26 textural features and four 3D shape descriptors were calculated from tumour volumes in both modalities. The repeatability of each metric was assessed by Bland-Altman analysis. Results: One hundred and five lesions (primary tumors and nodal or distant metastases) were delineated and characterized. The MAV and AV determination had a repeatability of −1.4±11.0% and −1.2±18.7% respectively. Several shape and heterogeneity features were found to be highly or moderately repeatable (e.g., sphericity, co-occurrence entropy or intensity size-zone matrix zone percentage), whereas others were confirmed as unreliable with much higher variability (more than twice that of the corresponding volume determination). Conclusion: Our results in this large multicenter cohort with more than 100 measurements confirm the PET findings in previous studies (with <30 lesions). In addition, our study is the first to explore the repeatability of radiomics features in the low-dose CT component of PET/CT acquisitions (previous studies considered dosimetry CT, CE-CT or CBCT). Several features were identified as reliable in both PET and CT components and could be used to build prognostic models. This work has received a French government support granted to the CominLabs excellence laboratory and managed by the National Research Agency in the “Investing for the Future” program under reference ANR-10-LABX-07-01, and support from the city of Brest.

60 APPLIED LIFE SCIENCES↗

Thoroughly testing and integrating hundreds of Pull Requests per month: ROOT’s new Cost-efficient and Feature Rich GitHub-based CI

ROOT is an open source framework, freely available on GitHub, at the heart of data acquisition, processing and analysis of HE(N)P experiments, and beyond. It is developed collaboratively: contributions are not authored only by ROOT team members, but also by the user community at large: developers and scientists from universities, labs as well as the private sector. More than 1500 GitHub Pull Requests are merged on average per year. It is in this context that code integration acquires a primary role. The review of code contributions isn’t enough: not only they need to be thoroughly reviewed, they also need to be thoroughly tested through a powerful CI infrastructure on several different platforms to comply with the high code quality standards of the project. Since the end of 2023, ROOT moved its continuous integration system from Jenkins to GitHub Actions. In this contribution, we characterise the transition to the GitHub CI, focussing on our strategy, its implementation and the lessons learned, as well as the advantages the new system offers with respect to the previous one. Particular emphasis will be given to the evaluation of the cost-benefit ratio for Jenkins and GitHub Actions for the ROOT project. We also describe how we manage to run in less than one hour thousands of unit, integration, functional and end-to-end tests on different flavours of Windows, four versions of macOS, as well as about ten of the most used Linux distributions, taking advantage of the CERN computing infrastructure.

Piparo, Danilo [CERN]↗

Investigating YAP’s role in Human Mammary Epithelial Cell (HMEC) Immortalization and Cancer Stem Cell (CSC) Phenotype Acquisition during Early Breast Cancer Progression

The malignant aspect of tumorigenesis in breast cancer is initiated when human mammary epithelial cells (HMEC) first immortalize (gain the ability to proliferate indefinitely) and subsequently undergo oncogenic activation. Our laboratory has developed a two-step HMEC immortalization process that we believe accurately models early breast cancer progression. Normal finite pre-stasis HMEC must overcome two distinct senescence barriers to achieve full immortality: stasis (stress-associated senescence) and replicative senescence, respectively. HMEC bypass stasis, and become post-stasis, when errors in the retinoblastoma pathway are present. Replicative senescence, a product of continuously shortening telomeres producing telomere dysfunction, is overcome by the reactivation of telomerase. Our lab has called HMEC that acquire the error allowing telomerase expression conditionally immortal (CI); CI cells may still have low telomerase expression. Full immortality is achieved when sufficient telomerase expression exists to maintain short stable telomeres following a process we have called conversion. The transcriptional coactivator YAP, upregulated in several human cancers, is closely correlated with a variety of oncogenic effects including proliferation and induction of cancer stem cell (CSC) properties. Our preliminary data have shown that YAP-transduced post-stasis HMEC expressed properties of CI cells. Growth curves indicated that some cell lines achieved full immortality; however, these cells had acquired an additional error – amplified expression of c-Myc, an oncogene known to induce telomerase in post-stasis or CI cells. The absence of uniform immortalization in the YAP-transduced cells suggests that YAP causes post-stasis HMEC to become conditionally immortal. This is further supported given that YAP-transduced post-stasis HMEC have decreased levels of the lncRNA MORT and rapidly go through conversion when p53 function is abrogated, well-documented attributes of CI HMEC. Previous studies have also reported that YAP controls the differentiation of breast progenitor cells; as a result, it is likely that YAP plays a role in inducing CSC phenotypes. In this study, we attempt to gain a greater understanding of YAP’s role in HMEC immortalization and induction of CSC properties in early breast cancer progression. We measured gene expression levels and attempted to identify proteins indicative of a CSC phenotype in YAP-transduced post-stasis HMEC. Our initial results did not reveal an association between YAP and HMEC conditional immortality or induction of CSC attributes in the cultures examined. However, using a YAP construct that promotes nuclear localization (where YAP is most active) has led to a potentially promising YAP-derived cell line that we presume to be immortal. We go on to demonstrate that YAP may be acting via non-transcriptional oncogenic roles in our HMEC specimens. Thus, we recommend future studies into YAP and the HMEC immortalization process given that they are promising targets for breast cancer prevention therapies.

Shah, Manav↗