Search NASA⌕ Search

SEARCH · Search NASA

Results for “analysis programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Nuclear magnetic resonance probe head design for precision strain control

Here, we present the design and construction of an NMR probe to investigate single crystals under strain at cryogenic temperatures. The probe head incorporates a piezoelectric-based apparatus from Razorbill Instruments that enables both compressive and tensile strain tuning up to strain values on the order of 0.3% with a precision of 0.001%. 75 As NMR in BaFe 2 As 2 reveals large changes to the electric field gradient and indicates that the strain is homogeneous to within 16% over the volume of the NMR coil.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CONFIRMATION OF X-RAY ABSORPTION BY WARM-HOT INTERGALACTIC MEDIUM IN THE SCULPTOR WALL

In a previous paper, we reported a 3{sigma} detection of an absorption line from the warm-hot intergalactic medium (WHIM) using the Chandra and XMM X-ray grating spectra of the blazar H2356-309, the sight line of which intercepts the Sculptor Wall, a large-scale superstructure of galaxies at z {approx} 0.03. To verify our initial detection, we obtained a deep (500 ks), follow-up exposure of H2356-309 as part of the Cycle-10 Chandra Large Project Program. From a joint analysis of the Cycle-10 and previous (Cycle-8) Chandra grating data we detect the redshifted O VII WHIM line at a significance level of 3.4{sigma}, a substantial improvement over the 1.7{sigma} level reported previously when using only the Cycle-8 data. The significance increases to 4.0{sigma} when the existing XMM grating data are included in the analysis, thus confirming at higher significance the existence of the line at the redshift of the Sculptor Wall with an equivalent width of 28.5 {+-} 10.5 mA (90% confidence). We obtain a 90% lower limit on the O VII column density of 0.8 x 10{sup 16} cm{sup -2} and a 90% upper limit on the Doppler b parameter of 460 km s{sup -1}. Assuming the absorber is uniformly distributed throughout the {approx}15 Mpc portion of the blazar's sight line that intercepts the Sculptor Wall, that the O VII column density is {approx}2 x 10{sup 16} cm{sup -2} (corresponding to b {approx_gt} 150 km {sup -1} where the inferred column density is only weakly dependent on b), and that the oxygen abundance is 0.1 solar, we estimate a baryon over-density of {approx}30 for the WHIM, which is consistent with the peak of the WHIM mass fraction predicted by cosmological simulations. The clear detection of O VII absorption in the Sculptor Wall demonstrates the viability of using current observatories to study WHIM in the X-ray absorption spectra of blazars behind known large-scale structures.

79 ASTRONOMY AND ASTROPHYSICS↗

Herschel observations of the W3 GMC (II): Clues to the formation of clusters of high-mass stars

The W3 giant molecular cloud is a prime target for investigating the formation of high-mass stars and clusters. This second study of W3 within the HOBYS Key Program provides a comparative analysis of subfields within W3 to further constrain the processes leading to the observed structures and stellar population. Probability density functions (PDFs) and cumulative mass distributions (CMDs) were created from dust column density maps, quantified as extinction A{sub V}. The shape of the PDF, typically represented with a lognormal function at low A{sub V} “breaking” to a power-law tail at high A{sub V}, is influenced by various processes including turbulence and self-gravity. The breaks can also be identified, often more readily, in the CMDs. The PDF break from lognormal (A{sub V}(SF) ≈ 6–10 mag) appears to shift to higher A{sub V} by stellar feedback, so that high-mass star-forming regions tend to have higher PDF breaks. A second break at A{sub V}>50 mag traces structures formed or influenced by a dynamic process. Because such a process has been suggested to drive high-mass star formation in W3, this second break might then identify regions with potential for hosting high-mass stars/clusters. Stellar feedback appears to be a major mechanism driving the local evolution and state of regions within W3. A high initial star formation efficiency in a dense medium could result in a self-enhancing process, leading to more compression and favorable star formation conditions (e.g., colliding flows), a richer stellar content, and massive stars. This scenario would be compatible with the “convergent constructive feedback” model introduced in our previous Herschel study.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH- AND INTERMEDIATE-MASS YOUNG STELLAR OBJECTS IN THE LARGE MAGELLANIC CLOUD

Archival Spitzer Infrared Array Camera (IRAC) and MIPS observations of the Large Magellanic Cloud (LMC) have been used to search for young stellar objects (YSOs). We have carried out independent aperture photometry of these data and merged the results from different passbands to produce a photometric catalog. To verify our methodology we have also analyzed the data from the SAGE and SWIRE Legacy programs; our photometric measurements are in general agreement with the photometry released by these programs. A detailed completeness analysis for our photometric catalog of the LMC shows that the 90% completeness limits are, on average, 16.0, 15.0, 14.3, 13.1, and 9.2 mag at 3.6, 4.5, 5.8, 8.0, and 24 {mu}m, respectively. Using our mid-infrared photometric catalogs and two simple selection criteria, [4.5]-[8.0]>2.0 to exclude normal and evolved stars and [8.0]>14-([4.5]-[8.0]) to exclude background galaxies, we have identified a sample of 2910 sources in the LMC that could potentially be YSOs. We then used the Spitzer observations complemented by optical and near-infrared data to carefully assess the nature of each source. To do so we simultaneously considered multiwavelength images and photometry to assess the source morphology, spectral energy distribution (SED) from the optical through the mid-infrared wavelengths, and the surrounding interstellar environment to determine the most likely nature of each source. From this examination of the initial sample, we suggest that 1172 sources are most likely YSOs. We have also identified 1075 probable background galaxies, consistent with the expected number estimated from the SWIRE survey. Spitzer IRS observations of 269 of the brightest YSOs from our sample have confirmed that {approx}>95% are indeed YSOs. An examination of color-color and color-magnitude diagrams shows no simple criteria in color-magnitude space that can unambiguously separate the LMC YSOs from all asymptotic giant branch (AGB)/post-AGB stars, planetary nebulae, and background galaxies. A comprehensive search for YSOs in the LMC has also been carried out by the SAGE team and reported by Whitney et al. There are three major differences between these two searches. (1) In the common region of color-magnitude space, {approx}850 of our 1172 probable YSOs are missed in the SAGE YSO catalog because their conservative point-source identification criteria have excluded YSOs superposed on complex stellar and interstellar environments. (2) About 20%-30% of the YSOs identified by the SAGE team are sources we classify as background galaxies. (3) The SAGE YSO catalog identifies YSO in parts of color-magnitude space that we excluded and thus contains more evolved or fainter YSOs missed by our analysis. The shortcomings and strengths of both these YSO catalogs should be considered prior to statistical studies of star formation in the LMC. Finally, the mid-infrared luminosity functions in the IRAC bands of our most likely YSO candidates in the LMC can be well described by N(L) {proportional_to} L {sup -1}, which is consistent with the Salpeter initial mass function if a mass-luminosity relation of L {proportional_to} M {sup 2.4} is adopted.

79 ASTRONOMY AND ASTROPHYSICS↗

WavePropaGator : interactive framework for X-ray free-electron laser optics design and simulations

This article describes the WavePropaGator (WPG) package, a new interactive software framework for coherent and partially coherent X-ray wavefront propagation simulations. The package has been developed at European XFEL for users at the existing and emerging free-electron laser (FEL) facilities, as well as at the third-generation synchrotron sources and future diffraction-limited storage rings. The WPG addresses the needs of beamline scientists and user groups to facilitate the design, optimization and improvement of X-ray optics to meet their experimental requirements. The package uses the Synchrotron Radiation Workshop (SRW) C/C++ library and its Python binding for numerical wavefront propagation simulations. The framework runs reliably under Linux, Microsoft Windows 7 and Apple Mac OS X and is distributed under an open-source license. The available tools allow for varying source parameters and optics layouts and visualizing the results interactively. The wavefront history structure can be used for tracking changes in every particular wavefront during propagation. The batch propagation mode enables processing of multiple wavefronts in workflow mode. The paper presents a general description of the package and gives some recent application examples, including modeling of full X-ray FEL beamlines and start-to-end simulation of experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topology-Aware Performance Optimization and Modeling of Adaptive Mesh Refinement Codes for Exascale

Here, we introduce a topology-aware performance optimization and modeling workflow for AMR simulation that includes two new modeling tools, ProgrAMR and Mota Mapper, which interface with the BoxLib AMR framework and the SSTmacro network simulator. ProgrAMR allows us to generate and model the execution of task dependency graphs from high-level specifications of AMR-based applications, which we demonstrate by analyzing two example AMR-based multigrid solvers with varying degrees of asynchrony. Mota Mapper generates multiobjective, network topology-aware box mappings, which we apply to optimize the data layout for the example multigrid solvers. While the sensitivity of these solvers to layout and execution strategy appears to be modest for balanced scenarios, the impact of better mapping algorithms can be significant when performance is highly constrained by network hop latency. Furthermore, we show that network latency in the multigrid bottom solve is the main contributing factor preventing good scaling on exascale-class machines.

97 MATHEMATICS AND COMPUTING↗

TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-259: GPR Tables for the Estimation of Mid-Plane Dose Using EPID

Purpose: To develop a simple method for estimating the mid-plane dose (MPD) of a patient using Electronic Portal imaging Device (EPID). Methods: A Varian TrueBeam with aSi100 EPID was used in this study. The EPID images were acquired for a 30 cm × 30 cm homogeneous slab phantom and a 30 cm diameter 20 cm thick cylindrical phantom in the continuous dosimetry mode. The acquired EPID images in XIM format were imported into in-house MATLAB program for the data analysis. First, the dosimetric characteristics of EPID were studied for dose-response linearity, dose-rate dependence, and field size dependence. Next, the average pixels values of the EPID images were correlated with the MPD measured by an ionisation chamber for various thicknesses of the slab phantom (8 cm – 30 cm) and for various square field sizes (3×3 cm{sup 2} – 25×25 cm{sup 2} at the isocenter). Look-up tables called as GPR tables were then generated for both SSD and SAD setup by taking the ratio of MPD measured by the ionisation chamber and the corresponding EPID pixel values. The accuracy of the GPR tables was evaluated by varying the field size, phantom thickness, and wedge angles with the slab and cylindrical phantoms. Results: The dose response of EPID was linear from 20 MU to 300 MU. The EPID response for different dose rates from 40 MU/min to 600 MU/min was within ±1%. The difference in the doses from the GPR tables and the doses measured by the ionization chambers were within 2% for slab phantoms, and 3% for the cylindrical phantom for various field sizes, phantom thickness, and wedge angles. Conclusion: GPR tables are a ready reckoner for in-vivo dosimetry and it can be used to quickly estimate the MPD value from the EPID images with an accuracy of ±3% for common clinical treatment. project work funded by Union for International cancer control(UICC) under ICRETT fellowship.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife

Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dose deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

LAVA: An Open-Source Approach To Designing LAMP (Loop-Mediated Isothermal Amplification) DNA Signatures

Background: We developed an extendable open-source Loop-mediated isothermal AMPlification (LAMP) signature design program called LAVA (LAMP Assay Versatile Analysis). LAVA was created in response to limitations of existing LAMP signature programs. Results: LAVA identifies combinations of six primer regions for basic LAMP signatures, or combinations of eight primer regions for LAMP signatures with loop primers, which can be used as LAMP signatures. The identified primers are conserved among target organism sequences. Primer combinations are optimized based on lengths, melting temperatures, and spacing among primer sites. We compare LAMP signature candidates for Staphylococcus aureus created both by LAVA and by PrimerExplorer. We also include signatures from a sample run targeting all strains of Mycobacterium tuberculosis. Conclusions: We have designed and demonstrated new software for identifying signature candidates appropriate for LAMP assays. The software is available for download at http://lava-dna.googlecode.com/.

59 BASIC BIOLOGICAL SCIENCES↗

Search for CP violation in singly Cabibbo suppressed four-body D decays

We search for CP violation in a sample of 4.7 x 10 4 singly Cabibbo suppressed D 0 → K + K - π + π - decays and 1.8(2.6) x 10 4 D (s) + → K S 0 K + π + π - decays. CP violation is searched for in the difference between the T-odd asymmetries, obtained using triple product correlations, measured for D and D decays. The measured CP violation parameters are A T (D 0 ) = (1.0 ± 5.1(stat) ± 4.4(syst)) x 10 -3 , A T (D + ) = (-11.96 ± 10.04(stat) ± 4.81(syst)) x 10 -3 and A T (D s + ) = (-13.57 ± 7.67(stat) ± 4.82(syst)) x 10 -3 . This search for CP violation showed that the T-odd correlations are a powerful tool to measure the CP violating observable A T . The relative simplicity of an analysis based on T-odd correlations and the high quality results that can be obtained, allow to consider this tool as fundamental to search for CP violation in four-body decays. Even if the CP violation has not been found, excluding any New Physics effect to the sensitivity of about 0.5%, it is still worth to search for CP violation in D decays. The high statistics that can be obtained at the LHC or by the proposed high luminosity B-factories, make this topic to be considered in high consideration by experiments such as LHCb, SuperB or SuperBelle. The results outlined in this thesis strongly suggest to include a similar analysis into the Physics program of these experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integration of Heat Transfer, Stress, and Particle Trajectory Simulation

Calabazas Creek Research, Inc. developed and currently markets Beam Optics Analyzer (BOA) in the United States and abroad. BOA is a 3D, charged particle optics code that solves the electric and magnetic fields with and without the presence of particles. It includes automatic and adaptive meshing to resolve spatial scales ranging from a few millimeters to meters. It is fully integrated with CAD packages, such as SolidWorks, allowing seamless geometry updates. The code includes iterative procedures for optimization, including a fully functional, graphical user interface. Recently, time dependent, particle in cell capability was added, pushing particles synchronically under quasistatic electromagnetic fields to obtain particle bunching under RF conditions. A heat transfer solver was added during this Phase I program. Completed tasks include: (1) Added a 3D finite element heat transfer solver with adaptivity; (2) Determined the accuracy of the linear heat transfer field solver to provide the basis for development of higher order solvers in Phase II; (3) Provided more accurate and smoother power density fields; and (4) Defined the geometry using the same CAD model, while maintaining different meshes, and interfacing the power density field between the particle simulator and heat transfer solvers. These objectives were achieved using modern programming techniques and algorithms. All programming was in C++ and parallelization in OpenMP, utilizing state-of-the-art multi-core technology. Both x86 and x64 versions are supported. The GUI design and implementation used Microsoft Foundation Class.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of SFR Primary System Simulation Capability for Advanced System Codes

Under the Reactor Product Line (RPL) of DOE/NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an SFR System Analysis Module is being developed at Argonne National Laboratory for whole-plant safety analysis. This tool will simulate tightly coupled physical phenomena – including nuclear fission, heat transfer, fluid dynamics, and thermal-mechanical response – in SFR structures, systems, and components. It is based on the MOOSE (Multi-physics Object-Oriented Simulation Environment) framework, which relies upon open-source libraries such as libMesh and PETSc for mesh generation, finite element analysis, and numerical solutions. This development is a coordinated effort along with the development of RELAP-7, which is an advanced safety analysis tool for light-water reactors developed at Idaho National Laboratory. The SFR Module is aimed to model and simulate the SFR systems with much higher fidelity and with well-defined and validated prediction capabilities. It will provide fast-running, modest-fidelity, whole-plant transient analyses capability, which is essential for fast turnaround design scoping and engineering analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Appendix J – GPRA05 Vehicle Technologies Program Documentation

Light-vehicle (LV) attributes were based on the FreedomCAR and Vehicle Technologies (FCVT) program goals, discussions with FCVT program managers, and technical analysis by contractors (Ref. 1). They were also based on a review of past GPRA characterizations (e.g., attributes included in the 2003 GPRA transportation methodology report that can be found on the EERE Web site (Ref. 2). Because the two models (NEMS-GPRA05 and MARKAL-GPRA05) that generate GPRA results require different levels of detail, the technical characterizations were provided in two parts: one for input to NEMS-GPRA05 and one for input to MARKALGPRA05. The discussion of the LV characterization is, thus, divided into two parts below.

33 ADVANCED PROPULSION SYSTEMS↗

Executive Summary

This document summarizes the results of the benefits analysis of EERE’s programs, as described in the FY 2005 Budget Request.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Executive Summary

This document summarizes the results of the benefits analysis of EERE’s programs, as described in the FY 2007 Budget Request.

2007 Budget↗