Search NASA⌕ Search

SEARCH · Search NASA

Results for “channel coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Evaluation of anticipatory signal to steam generator pressure control program for 700 MWe Indian pressurized heavy water reactor

700 MWe Indian Pressurized Heavy Water Reactor (IPHWR) is horizontal channel type reactor with partial boiling at channel outlet. Due to boiling, it has a large volume of vapor present in the primary loops. It has two primary loops connected with the help of pressurizer surge line. The pressurizer has a large capacity and is partly filled by liquid and partly by vapor. Large vapor volume improves compressibility of the system. During turbine trip or load rejection, pressure builds up in Steam Generator (SG). This leads to pressurization of Primary Heat Transport System (PHTS). To control pressurization of SG and PHTS, around 70% of the steam generated in SG is dumped into the condenser by opening Condenser Steam Dump Valves (CSDVs) and rest of the steam is released to the atmosphere by opening Atmospheric Steam Discharge Valves (ASDVs) immediately after sensing the event. This is accomplished by adding anticipatory signal to the output of SG pressure controller. Anticipatory signal is proportional to the thermal power of reactor and the proportionality constant is set so that SG pressure controller's output jacks up to ASDV opening range when operating at 100% FP. To simulate this behavior for 700 MWe IPHWR, Primary and secondary heat transport system is modeled. SG pressure control and other process control program have also been modeled to capture overall plant dynamics. Analysis has been carried out with 3-D neutron kinetics coupled thermal hydraulic computer code ATMIKA.T to evaluate the effect of the anticipatory signal on PHT pressure and over all plant dynamics during turbine trip in 700 MWe IPHWR. This paper brings out the results of the analysis with and without considering anticipatory signal in SG pressure control program during turbine trip. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The role of ion and electron-scale turbulence in setting heat and particle transport in the DIII-D ITER baseline scenario

In this work, the heat and particle transport in a DIII-D ITER Baseline Scenario (IBS) discharge has been investigated using both linear and nonlinear gyrokinetic simulations performed with the CGYRO code [J. Candy et al: Journal Comp. Phys. (2016)].These simulations were used to investigate the role that ion-scale ($k_θp_s$ < 1:0) and electron-scale ($k_θp_s$ > 1:0) turbulence play in determining heat and particle transport in the core of conditions believed to directly extrapolate to ITER operation. This investigation spans over nearly half of the plasma minor radius, from ρ = 0:45 - 0:85. To probe the nature of the transport and turbulence in these conditions and to validate the model against experimental fluxes, scans of $a/L_{T_i}$, $a/L_{T_e}$, and $a/L_n$ were performed at all radial locations. Long wavelength turbulence is found to be dominated by ITG modes with strong non-adiabatic electron effects and appears unable to reproduce ion and electron heat fluxes and electron particle fluxes simultaneously at most radial positions when single parameter scans are performed. To investigate the potential role of short wavelength turbulence, a series of electron-scale simulations are performed that indicate that experimentally relevant levels of electron heat flux could arise at sub-ion scales. Quantitative comparison of the simulated fluxes obtained from ion and electron-scale simulations with experimental levels along with the sensitivity of simulations results to changes in inputs is presented. Through extensive sensitivity scans and comparison with multiple transport channels, this work demonstrates a clear need for self-consistent modification of multiple inputs and suggests multi-scale interactions play a significant role at many of the radial locations studied. The results of this analysis help shape our understanding of the model fidelity needed to predict turbulence and transport reactor-relevant conditions and have important implications for the prediction of future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The application of MAMMOTH for a detailed tightly coupled fuel pin simulation with a station blackout

The accurate calculation of desired quantities to predict fuel behavior in a nuclear reactor requires the solution of inter linked equations representing different physics phenomena. Traditional fuels performance codes often rely on internal empirical models for the pin power density and a simplified boundary condition on the cladding outer surface. These simplifications are performed because of the difficulty of coupling applications or codes on differing domains and mapping the required data. In this work the MAMMOTH application is employed in the demonstration of an approach that more consistent with first principles, in a simulation that couples the neutronics application Rattlesnake, the thermal fluids application RELAP-7 and the fuels performance application BISON. A single fuel pin was modeled based on the dimensions of a fuel rod from a Westinghouse 17*17 optimized PWR fuel assembly. The simulation consisted of a depletion period of 1343 days, representing three full operating cycles, followed by a station blackout (SBO) event. The fuel rod was depleted with a total pin power of 65.81 kW. After 1343 days the fission power was reduced to zero (simulating a reactor shutdown). Decay heat calculations provided the time-varying energy source after this time. For this problem, Rattlesnake, BISON, and RELAP-7 are coupled under MAMMOTH in a tightly coupled approach. Each system solves its physics on a separate mesh and, for RELAP-7 and BISON, on only a subset of the full problem domain. Rattlesnake solves the neutronics over the whole domain, which includes the fuel, cladding, gaps, water, and top and bottom rod holders. Here BISON is applied to the fuel and cladding with a 2-D axisymmetric domain, and RELAP-7 is applied to the flow of the circular outer water channel with a set of 1-D flow equations. For this work, the mesh on the Rattlesnake side is either be 3-D (for low order PN transport or diffusion) or 2-D axisymmetric (for diffusion). BISON has a matching ring structure mesh for the fuel so both the power density and local burnup are transferred accurately from Rattlesnake. At each depletion time step, Rattlesnake calculates a power density, fission density rate, burnup distribution and fast flux based on the current water density and fuel temperature. These are then mapped to the BISON mesh to perform a fuels performance solution. BISON calculates the fuel temperature and cladding surface temperature based upon the current power density and bulk fluid temperature. RELAP-7 then calculates the fluid temperature, water density fraction and water phase velocity based upon the cladding surface temperature. The fuel temperature and the fluid density are then passed back to Rattlesnake for another neutronics calculation. For this paper, sets of results from the detailed calculation are provided for both depletion and the SBO event. We demonstrate that a detailed simulation akin to first principles can be achieved using MAMMOTH and the various MOOSE application on differing domains. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Gyrokinetic simulations of mesoscale energetic particle-driven Alfvenic turbulent transport embedded in microturbulence

Energetic particle (EP) transport from local high-n toroidal Alfven eigenmodes (TAEs) and energetic particle modes (EPMs) is simulated with a gyrokinetic code. Linear and nonlinear simulations have identified a parameter range where the longwave TAE and EPM are unstable alongside the well-known ion-temperature-gradient (ITG) and trapped-electron-mode (TEM) instabilities. A new eigenvalue solver in GYRO facilitates this mode identification. States of nonlinearly saturated local TAE/EPM turbulent intensity are identified, showing a 'soft' transport threshold for enhanced energetic particle transport against the TAE/EPM drive from the EP pressure gradient. The very long-wavelength (mesoscale) TAE/EPM transport is saturated partially by nonlinear interaction with microturbulent ITG/TEM-driven zonal flows. Fixed-gradient-length, nonlinearly saturated states are accessible over a relatively narrow range of EP pressure gradient. Within this range, and in the local limit employed, TAE/EPM-driven transport more closely resembles drift-wave microturbulent transport than 'stiff' ideal MHD transport with a clamped critical total pressure gradient. At a higher, critical EP pressure gradient, fixed-gradient nonlinear saturation fails: EP transport increases without limit and background transport decreases. Presumably saturation is then obtained by relaxation of the EP pressure gradient to near this critical EP pressure gradient. If the background plasma gradients driving the ITG/TEM turbulence and zonal flows are weakened, the critical gradient collapses to the TAE/EPM linear stability threshold. Even at the critical EP pressure gradient there is no evidence that TAE/EPM instability significantly increases transport in the background plasma channels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE EFFECT OF STARSPOTS ON ACCURATE RADIUS DETERMINATION OF THE LOW-MASS DOUBLE-LINED ECLIPSING BINARY GU Boo

GU Boo is one of only a relatively small number of well-studied double-lined eclipsing binaries that contain low-mass stars. Lopez-Morales and Ribas present a comprehensive analysis of multi-color light and radial velocity curves for this system. The GU Boo light curves presented by Lopez-Morales and Ribas had substantial asymmetries, which were attributed to large spots. In spite of the asymmetry, Lopez-Morales and Ribas derived masses and radii accurate to {approx_equal}2%. We obtained additional photometry of GU Boo using both a CCD and a single-channel photometer and modeled the light curves with the ELC software to determine if the large spots in the light curves give rise to systematic errors at the few percent level. We also modeled the original light curves from the work of Lopez-Morales and Ribas using models with and without spots. We derived a radius of the primary of 0.6329 +- 0.0026 R{sub sun}, 0.6413 +- 0.0049 R{sub sun}, and 0.6373 +- 0.0029 R{sub sun} from the CCD, photoelectric, and Lopez-Morales and Ribas data, respectively. Each of these measurements agrees with the value reported by Lopez-Morales and Ribas (R{sub 1} = 0.623 +- 0.016 R{sub sun}) at the level of {approx}2%. In addition, the spread in these values is {approx}1%-2% from the mean. For the secondary, we derive radii of 0.6074 +- 0.0035 R{sub sun}, 0.5944 +- 0.0069 R{sub sun}, and 0.5976 +- 0.0059 R{sub sun} from the three respective data sets. The Lopez-Morales and Ribas value is R{sub 2} = 0.620 +- 0.020 R{sub sun}, which is {approx}2%-3% larger than each of the three values we found. The spread in these values is {approx}2% from the mean. The systematic difference between our three determinations of the secondary radius and that of Lopez-Morales and Ribas might be attributed to differences in the modeling process and codes used. Our own fits suggest that, for GU Boo at least, using accurate spot modeling of a single set of multi-color light curves results in radii determinations accurate at the {approx}2% level.

79 ASTRONOMY AND ASTROPHYSICS↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

High-speed, multi-channel detector readout electronics for fast radiation detectors

In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz

Purpose: In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techniques was compared and the model was validated by experimental fluence and dose determinations. Methods: The depletion calculation code ORIGEN2 was used to compute the burn-up and relevant material composition of each burned fuel element from the day of first reactor operation to its current core. The material composition of the current core was used in a MCNP5 model of the initial core developed earlier. To perform calculations for the region outside the reactor core, the model was expanded to include the thermal column and compared with the previously established ATTILA model. Subsequently, the computational model is simplified in order to reduce the calculation time. Both simulation models are validated by experiments with different setups using alanine dosimetry and gold activation measurements with two different types of phantoms. Results: The MCNP5 simulated neutron spectrum and source strength are found to be in good agreement with the previous ATTILA model whereas the photon production is much lower. Both MCNP5 simulation models predict all experimental dose values with an accuracy of about 5%. The simulations reveal that a Teflon environment favorably reduces the gamma dose component as compared to a polymethyl methacrylate phantom. Conclusions: A computer model for BNCT dosimetry was established, allowing the prediction of dosimetric quantities without further calibration and within a reasonable computation time for clinical applications. The good agreement between the MCNP5 simulations and experiments demonstrates that the ATTILA model overestimates the gamma dose contribution. The detailed model can be used for the planning of structural modifications in the thermal column irradiation channel or the use of different irradiation sites than the thermal column, e.g., the beam tubes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactivity measurements using the Zolotukhin-Mogilner Method

The zero count probability method (also called Zolotukhin-Mogilner Method, after its inventors) is a method for measuring the reactivity in nuclear reactors, being a competitor of the [more well-known in the West] Feynman-alpha Method and the Rossi-alpha Method. The modus operandi of this method is using the detector channels where there was no counting at all in order to calculate reactor parameters. In deep subcriticality few models have been tested and this work tries out the Zolotukhin-Mogilner Method in one of such scenarios: measurements will be made in environments below -3,5 k pcm in the zero-potency water-moderated reactor IPEN/MB-01 which is fuelled by UO{sub 2} enriched by 4.3%. These extremely low reactivity environments are required because the chance of no counts on the detector must be significant: otherwise, the method would demand a large time of acquisition of data. Besides that, the method is very simple and straightforward. One of the advantages of this method is that it needs very little data reduction, since the essential data is directly given by the measuring apparatus. The detection will be in charge of modern BF{sub 3} detectors. It will be assumed that, in these deep subcritical systems, the function K{sub eff} = f(N-Nkp) has a linear portion in its first part, resulting of the decomposition of it in a Taylor series. The value of alpha is related to the reactivity ρ with linear dependency. The results will be compared with recent studies of the two main methods described above. Presented for the first time in the 60's, this tool has seen little use in the west hemisphere. This work shows its use in the measurements of the nuclear reactor IPEN/MB-01, as well as the code developed for its employment. It will be the first time this method is used in the south hemisphere. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-I-15: Evaluation of a New MR-Compatible Respiratory Motion Device at 3T

Purpose: Recent advances in MRI-guided radiotherapy has inspired the development of MRI-compatible motion devices that simulate patient periodic motion in the scanner, particularly respiratory motion. Most commercial devices rely on non MR-safe ferromagnetic stepper motors which are not practical for regular QA testing. This work evaluates the motion performance of a new fully MRI compatible respiratory motion device at 3T. Methods: The QUASAR™ MRI-compatible respiratory motion phantom has been recently developed by Modus QA Inc., London, ON, Canada. The prototype is constructed from diamagnetic materials with linear motion generated using MRI-compatible piezoelectric motors that can be safely inserted in the scanner bore. The tumor was represented by a fillable sphere and is attached to the linear motion generator. The spherical tumor-representative and its surroundings were filled with different concentrations of MnCl2 to produce realistic relaxation times. The motion was generated along the longitudinal (H/F) axis of the bore using sinusoidal reference waveform (amplitude = 15 mm, frequency 0.25 Hz). Imaging was then performed on 3T Philips Achieva using a 32-channel cardiac coil. Fast 2D spoiled gradient-echo was used with a spatial resolution of 1.8 × 1.8 mm{sup 2} and slice thickness of 4 mm. The motion waveform was then measured on the resultant image series by tracking the centroid of the sphere through the time series. This image-derived measured motion was compared to the software-generated reference waveform. Results: No visible distortions from the device were observed on the images. Excellent agreement between the measured and the reference waveforms were obtained. Negligible motion was observed in the lateral (R/L) direction. Conclusion: Our investigation demonstrates that this piezo-electric motor design is effective at simulating periodic motion and is a potential candidate for MRI-radiotherapy respiratory motion simulation. Future work should focus on evaluating non-sinusoidal waveforms, fast 3D pulse sequences, and perform dosimetric QA.

60 APPLIED LIFE SCIENCES↗

SU-E-T-84: Comparison of Three Different Systems for Patient-Specific Quality Assurance: Cranial Stereotactic Radiosurgery Using VMAT with Multiple Non Coplanar Arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered. The purpose of the study is to compare three different dosimeters for pre-treatment QA. Methods: Nineteen patients (affected by neurinomas, brain metastases, and by meningiomas) were treated with VMAT plans computed on a Monte Carlo based TPS. Gafchromic films inside a slab phantom (GF), 3-D cylindrical phantom with two orthogonal diodes array (DA), and 3-D cylindrical phantom with a single rotating ionization chambers array (ICA), have been evaluated. The dosimeters are, respectively, characterized by a spatial resolution of: 0.4 (in our method), 5 and 2.5 mm. For GF we used a double channel method for calibration and reading protocol; for DA and ICA we used the 3-D dose distributions reconstructed by the two software sold with the dosimeters. With the need of a common system for analyze different measuring approaches, we used an in-house software that analyze a single coronal plane in the middle of the phantoms and Gamma values (2% / 2 mm and 3% / 3 mm) were computed for all patients and dosimeters. Results: The percentage of points with gamma values less than one was: 95.7% for GF, 96.8% for DA and 95% for ICA, using 3%/3mm criteria, and 90.1% for GF, 92.4% for DA and 92% for ICA, using 2% / 2mm gamma criteria. Tstudent test p-values obtained by comparing the three datasets were not statistically significant for both gamma criteria. Conclusion: Gamma index analysis is not affected by different spatial resolution of the three dosimeters.

60 APPLIED LIFE SCIENCES↗

Floodplain and Wetland Assessment for the Mortandad Wetland Enhancement and the DP Dissipater Projects at Los Alamos National Laboratory

This floodplain and wetland assessment was prepared in accordance with 10 Code of Federal Regulations (CFR) 1022 Compliance with Floodplain and Wetland Environmental Review Requirements, which was promulgated to implement the U.S. Department of Energy (DOE) requirements under Executive Order 11988 Floodplain Management and Executive Order 11990 Wetlands Protection. According to 10 CFR 1022, a 100-year floodplain is defined as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands” and a wetland is defined as “an area that is inundated or saturated by surface or groundwater at a frequency and duration sufficient to support, and that under normal circumstances does support, a prevalence of vegetation typically adapted for life in saturated soil conditions, including swamps, marshes, bogs, and similar areas.” In this action, DOE is proposing two projects to improve wetland and floodplain function at Los Alamos National Laboratory (LANL). The proposed work will comply with corrective action requirements under the Settlement Agreement and Stipulated Final Compliance Order (Settlement Agreement)1 Number HWB-14-20. The first project is located in Technical Areas (TA)-03 in upper Mortandad Canyon. The upper Mortandad wetlands have existing stormwater controls that need to be rehabilitated. Head-cut formation is occurring at the downstream portion of the wetland. This project will repair damages to the wetland and reduce the future erosion potential. The second project is located in TA-21 in Delta Prime (DP) Canyon. The intent of the DP Dissipater Project in DP Canyon is to install stormwater control structures in DP Canyon to retain low channel flows and reduce downstream sediment transport as well as peak flows during low and moderate storm events. Due to increased erosion, the stream bank in this area has unstable vertical walls within the stream channel. The DOE prepared this floodplain and wetland assessment to evaluate the potential impacts of implementing the proposed actions within the wetland and floodplain, as required by 10 CFR 1022.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-02: A Team Focused Clinical Implementation and Failure Mode and Effects Analysis of HDR Skin Brachytherapy Using Valencia and Leipzig Surface Applicators

Purpose: and Leipzig applicators (VLAs) are single-channel brachytherapy surface applicators used to treat skin lesions up to 2cm diameter. Source dwell times can be calculated and entered manually after clinical set-up or ultrasound. This procedure differs dramatically from CT-based planning; the novelty and unfamiliarity could lead to severe errors. To build layers of safety and ensure quality, a multidisciplinary team created a protocol and applied Failure Modes and Effects Analysis (FMEA) to the clinical procedure for HDR VLA skin treatments. Methods: team including physicists, physicians, nurses, therapists, residents, and administration developed a clinical procedure for VLA treatment. The procedure was evaluated using FMEA. Failure modes were identified and scored by severity, occurrence, and detection. The clinical procedure was revised to address high-scoring process nodes. Results: Several key components were added to the clinical procedure to minimize risk probability numbers (RPN): -Treatments are reviewed at weekly QA rounds, where physicians discuss diagnosis, prescription, applicator selection, and set-up. Peer review reduces the likelihood of an inappropriate treatment regime. -A template for HDR skin treatments was established in the clinical EMR system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planning physicist, and increases the detectability of an error during the physics second check. -A screen check was implemented during the second check to increase detectability of an error. -To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display. This facilitates data entry and verification. -VLAs are color-coded and labeled to match the EMR prescriptions, which simplifies in-room selection and verification. Conclusion: Multidisciplinary planning and FMEA increased delectability and reduced error probability during VLA HDR Brachytherapy. This clinical model may be useful to institutions implementing similar procedures.

60 APPLIED LIFE SCIENCES↗

Pressure Drop Correlation Improvement for the Near-Wall Region of Pebble-Bed Reactors

Packed beds play an important role in several engineering fields, with their applications in nuclear energy being driven by the development of next-generation reactors utilizing pebble fuel. The random nature of a packed pebble bed creates a flow field that is complex and difficult to predict. Porous media models are an attractive option for modeling pebble-bed reactors (PBRs), as they provide intermediate fidelity results and are computationally efficient. Porous media models, however, rely on the use of correlations to estimate the effect of complicated flow features on the pressure drop and heat transfer in the system. Existing correlations were developed to predict the average behavior of the bed, but they are inaccurate in the near-wall region where the presence of the wall affects the pebble packing. This work aims to investigate the accuracy of a porous media model using the Kerntechnischer Ausschuss (KTA) correlation, the most common pressure drop correlation for PBRs compared to the high-fidelity large eddy simulation (LES). A bed of 1568 pebbles is investigated at Reynolds numbers from 625 to 10 000. The bed is divided into five concentric subdomains to compare the average velocity, friction losses, and form losses between the porous media and LES codes. The comparison between the LES simulation and the KTA correlation revealed that the KTA correlation largely underpredicts the form losses in the near-wall region, leading to an overprediction of the velocity near the wall by nearly 30%. An investigation of the form losses across the range of Reynolds numbers in the LES results provided additional insight into how the KTA correlation may be improved to better predict these spatial effects in a pebble bed. These data suggest that the form coefficient near the wall must be increased by 48% while decreasing the form coefficient of the inner bulk region of the bed by 15%. The implementation of these improvements to the KTA correlation in a porous media model produced a radial velocity profile that saw significantly improved agreement with the LES results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spatial Study 2022: Surface Water Samples, Cotton Strip Degradation, and Hydrologic Sensor Data across the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin. The dataset provides data and photos generated from sample collection during the same one-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. The contents include surface water geochemistry data; river substrate grain size photos; stream depth data; manual chamber open channel respiration data; and field metadata (including qualitative information on instream and river corridor characteristics). Grain size photos can be used to improve estimates of channel substrate D50 data. The dataset also includes tensile strength and photos from cotton strip field degradation experiments; five-week sensor time series temperature, dissolved oxygen, pressure, pH, specific conductance, chlorophyll A, and turbidity data; plots of the sensor data; and R scripts used to generate the plots. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. SSS data published in the CM data package were not included in this data package. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Additionally, sensor data from a similar 2021 spatial study can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1892052 and 2021 sample data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1898914. The 2021 spatial study had some sites in common with this 2022 spatial study. This dataset is comprised of three photo folders and one main data folder with six subfolders. The photo folders contain photographs and videos of cotton strip retrieval and sediment quadrats. The main data folder consists of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) total suspended solids (TSS) data and cotton strip tensile strength data and averages; (5) field protocol; (6) readme; (7) methods codes; (8) international generic sample number (IGSN) mapping file; (9) sensor installation methods summary; (10) stream depth and averages; and (11) Ultrameter data and averages. The Sonar subfolder consists of Sonar time-series depth data and a processing script. The BarotrollAtm, DepthHOBO, MantaRiver, miniDOT, and miniDOTManualChamber subfolders contain time-series data, plots, and summary files. All files are .csv, .pdf, .txt, .R, .Rmd, .jpg, .jpeg, .AVI, .mp4, or .mov. The data package was originally published in April 2023. It was updated in August 2023 (v2; modified files) and September 2024 (v3; modified files). See the change history section in the readme for details. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

60 APPLIED LIFE SCIENCES↗