Relative Credits for Extra Efficiency Code Measures

Energy codes contain mandatory and prescriptive items. Mandatory items must be complied with and prescriptive items can be traded off with other efficiency measures by following a performance path. In addition, energy codes can contain an extra efficiency requirement, where one or a number of items can be chosen to satisfy it. These items are contained in section C406 of the IECC and there is currently an addendum under consideration for ASHRAE Standard 90.1 that would create several optional items with a requirement to select one.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ASC news highlight for HQ, 12/11/18

LLNL’s package management tool, Spack, has reduced software build times from weeks to hours for programmatic codes, and the tool’s popularity has grown beyond the NNSA laboratories. New workflow features and ongoing community-building efforts have led ECP and many top supercomputing sites worldwide to adopt Spack as their official deployment tool. With a community of over 330 Spack contributors, the maintenance burden for over 3,000 open source packages is now shared with other centers. This reduction of general ASC software maintenance costs frees up code development resources to address unique requirements specific to the stockpile stewardship mission.

97 MATHEMATICS AND COMPUTING↗

Efficient Binary Static Code Data Flow Analysis Using Unsupervised Learning

The ever increasing need to ensure that code is reliably, efficiently and safely constructed has fueled the evolution of popular static binary code analysis tools. In identifying potential coding flaws in binaries, tools such as IDA Pro are used to disassemble the binaries into an opcode/assembly language format in support of manual static code analysis. Because of the highly manual and resource intensive nature involved with analyzing large binaries, the probability of overlooking potential coding irregularities and inefficiencies is quite high. In this paper, a light-weight data, unsupervised data flow methodology is described which uses highly-correlated data flow graph (CDFGs) to identify coding irregularities such that analysis time and required computing resources are minimized. Such analysis accuracy and efficiency gains are achieved by using a combination of graph analysis and unsupervised machine learning techniques which allows an analyst to focus on the most statistically significant flow patterns while performing binary static code analysis.

97 MATHEMATICS AND COMPUTING↗

North Dakota Integrated Carbon Storage Complex Feasibility Study. Final report

In spring 2017, the Energy & Environmental Research Center (EERC) initiated an effort to determine the feasibility of developing a commercial-scale CO 2 geologic storage complex able to store 50+ million tonnes (Mt) of CO 2 in central North Dakota safely, permanently, and economically. The objective was to fulfill the goals of the U.S. Department of Energy (DOE) Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative and address technical and nontechnical challenges specific to commercial-scale deployment of a CO2 storage project. The findings clearly show that the concept of capturing CO 2 from a lignite-fired electrical generation facility in central North Dakota and safely and permanently storing the CO 2 in the deep subsurface is indeed technically, economically, and socially feasible. This project evaluated two study areas and their respective geologic storage complexes located adjacent to separate coal-fired facilities in North Dakota: the Basin Electric Power Cooperative (BEPC)-owned Great Plains Synfuels Plant (GPSP) and the Minnkota Power Cooperative (Minnkota)-owned Milton R. Young Station (MRYS). These locations, one with CO 2 capture in place and an existing CO 2 pipeline, are bolstered by progressive North Dakota pore space ownership and long-term liability laws. These elements and a motivated team created an ideal synergistic scenario for ensuring success of the CarbonSAFE Initiative and promoting North Dakota’s statewide vision for carbon management. The project included drilling two new geologic characterization wells, integrating an existing 3-D seismic survey, creating a geologic model subsequently used for injection simulation, a risk assessment, public outreach, and generating a site development plan based on results. In addition, the performance of select National Risk Assessment Partnership tools was evaluated. The geologic characterization wells were drilled ~5600 feet deep to the Broom Creek Formation; ~350 feet of core was retrieved from each well. The core included the Broom Creek (targeted injection zone) and a portion of the overlying Opeche Shale (seal). The Flemmer-1 well, west of Beulah, North Dakota, yielded 169 feet of sandstone. The BNI-1 well located south of Center, North Dakota, yielded 124 feet of sandstone. In each case, laboratory analysis of the sandstone showed permeability in the 300–1000-mD range, with porosity of 20%–30%. The Flemmer-1 well was sited within the boundaries of an existing 3-D seismic survey. Colocating the well with the seismic survey maximized the relationship between new and legacy data and developed a first-of-its-kind interpretation of the geologic fabric of the Broom Creek. Geologic characterization data were integrated into a 5544-mi 2 geocellular model that encompassed both new wells and stratigraphy from the surface to the Amsden Formation (underlying the Broom Creek). The model was later expanded vertically to include the deeper Black Island–Deadwood interval to examine its potential viability as a storage target. The geocellular model provided the foundation for dynamic simulation of CO 2 into the Broom Creek. Results of the simulation suggest that the Broom Creek could accept the DOE target rate of 2 Mt/yr of CO 2 into as few as two wells. To bracket the expected capture from MRYS, simulations were also investigated for a 4-Mt/yr rate near MRYS. Although more wells are needed (two additional), the Broom Creek still has the storage resource to accept the CO 2 at the increased rate. A risk assessment exercise was conducted to identify and assess technical and nontechnical risks that could prevent potential candidate storage complexes within the study area from serving as commercial storage sites. The assessment identified and evaluated six technical risk categories: 1) CO 2 injectivity, 2) storage capacity, 3) lateral migration of CO 2 , 4) lateral pressure propagation, 5) vertical migration of CO 2 or formation brine, and 6) induced seismicity. Following two rounds of analysis and scoring, no risks were determined to preclude continued efforts to develop carbon capture, utilization, and storage (CCUS) in central North Dakota. The risk assessment results will be used to guide future site characterization, modeling and simulation, and monitoring activities. A specific nontechnical strategic risk based on challenges that may be realized in amalgamation of pore space resulted in vertically expanding the geologic model to incorporate the potential for stacked storage in multiple saline reservoirs. By including the Black Island–Deadwood interval (the basal sedimentary reservoir in this region), the amalgamated areal extent could be reduced by as much as 45%. Working with a smaller geographic area reduces risks and costs associated with monitoring and pore space leasing. An economic evaluation incorporating capture; transport (<5 mi); Class VI wells; permitting; and monitoring, verification, and accounting suggests implementing commercial-scale CCUS is economically attractive if the federal tax benefits of 45Q are included. This is validated by Minnkota’s continued pursuit of CO 2 capture and geologic storage at MRYS through its Project Tundra initiative, indicating that there is a business case for CCUS in central North Dakota. Currently, North Dakota is the only state with underground injection control (UIC) Class VI primacy. Built into the North Dakota Century Code is a series of regulatory requirements that guide the process to obtain a Class VI CO 2 storage facility permit. As part of this project, a site development plan was compiled to assure compliance with North Dakota’s requirements to permit a commercial-scale CO 2 storage operation and includes a prospective time line encompassing a general breakdown of activities. In total, an estimated 30 months would be needed to execute the necessary steps to attain a North Dakota CO 2 storage facility permit. Outreach was an integral part of the project and encompassed any project-related activity that had contact or exposure beyond the project team. The goals of outreach were to foster an environment from which stakeholders could make informed decisions about the project and gauge community receptiveness to a CCUS project. A consistent set of messages and outreach products were developed in conjunction with an outreach advisory board that integrated project partners and team members. To gauge public acceptability of geologically storing CO 2 , 5611 households in the project area were invited to participate in an online survey. The survey results indicate that the public attitude regarding CCUS is neutral to positive, with strong sentiment that CO 2 capture and storage may be an approach to maintain the economic vitality of the region. To achieve project objectives, critical support in the form of financial backing, engineering evaluations, site access, outreach collaboration, operations data, risk assessment/evaluation, and software access was provided by BEPC, the North Dakota Industrial Commission Lignite Research Council, ALLETE Clean Energy, BNI Energy, North American Coal Corporation, Minnkota, Prairie Public Broadcasting, Computer Modelling Group Ltd., and Schlumberger.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the New Home Market Opportunity: Case Study and Cost Modeling for Solar and Storage in 2030

Residential solar and storage markets are growing in the United States. With approximately 1 million new homes constructed every year, this represents a significant opportunity for solar and storage installations. Some homebuilders have begun to build new homes with solar and storage included as a standard offering. It is not clear how solar and storage is incorporated into the new construction process and at what cost. Further, it is unclear what barriers or opportunities exist to scale this model nationwide. To fill this gap in the literature, this research conducts a case study of Mandalay Homes' new solar and storage community in Arizona to gather lessons learned. From this foundation, we further generate a set of pathways to reduce install costs and expand solar and storage market penetration in this sector. To model existing and 2030 solar and storage costs, we use the National Renewable Energy Laboratory's (NREL's) bottom-up cost model. This modeling is further informed by 12 interviews conducted with new home builders, solar contractors, and other subject matter expert organizations. Our case study analysis generated three key considerations for other homebuilders including: 1. Educating local permitting, inspection, and in some cases utility officials on solar and storage products, designs, and code compliant building practices may be required. The need for education may decline as more local governments and utilities review and approve solar and storage projects. 2. Incorporating solar and storage systems into the homebuilding process can add complexity and related coordination challenges. This does not need to result in home construction delays, but can result in costly contractor "dry runs" to construction sites. 3. Deploying solar and storage at the time of new construction has significant economies of scale, which can improve the value proposition of the systems. The case study, extant literature, and interviews were used to model both existing and future solar and storage installation costs at time of new construction. Here, we find three key cost reduction opportunities relating to solar and battery storage hardware, customer acquisition, and overhead. If future contractors can maximize the cost reduction opportunities outlined here, residential new construction costs could decline by 8 - 25% by 2030, depending on the modeled scenario. Though we expect costs to decline through 2030, it is unclear which of these scenarios may ultimately appear. Interviewees further identified a variety of barriers across each cost category that could temper the savings shown here. At the same time, interviewees described several pathways to scale the new construction solar and storage market, beyond installation cost savings. Interviewees confirmed that changes in finance, rate design, resilience policies, deployment mandates, and DER aggregation could all support more market adoption than seen today. These findings suggest that there are significant opportunities to expand new construction markets and this research can serve as a baseline to assess progress in this segment through 2030.

14 SOLAR ENERGY↗

Technical Bases for Consequence Analyses Using MACCS (MELCOR Accident Consequence Code System)

The use of MELCOR Accident Consequence Code System (MACCS) in regulatory applications requires that input parameters used in MACCS models have a defensible and transparent technical basis. The existing technical basis for MACCS parameters was identified and updates were developed based on current data and information. The transparent way these updates are documented provides a technical basis for updating MACCS parameters with consistent application among the MACCS user community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Qualification of SAS4A/SASSYS-1 for Sodium-Cooled Fast Reactor Authorization and Licensing (Final CRADA Report)

This project focuses on assessment and qualification of the SAS4A/SASSYS-1 advanced reactor safety analysis code and its capacity to fulfill requirements associated with license/authorization of a sodium-cooled fast reactor (SFR). Specific objectives of this proposal include: development of a formal documentation requirements matrix that complies with a vendor’s NQA-1 program to identify needs for qualification documentation; completion of software methods qualification gap analysis to identify and close gaps in the verification and validation basis of the software; generation of an Acceptance Test Report to confirm compliance with the software requirements specification; and closure of gaps in Software Design Description (SDD) to assist with the eventual generation of a Modeling Licensing Topic Report (LTR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diversion Path Analysis: A Proposed Methodology to Develop an MC&A Approach for Liquid-Fueled Molten Salt Reactors

Nuclear material control and accounting (MC&A) is a critical element of both the US Nuclear Regulatory Commission (NRC) and US Department of Energy (DOE)’s domestic safeguards and security requirements. NRC licensees are required, under Title 10 of the Code of Federal Regulations (10 CFR) Part 74 to establish and maintain an MC&A program that captures and records the quantities and locations of special nuclear material (SNM) at the facility. Along with physical protection, MC&A is a key element of domestic nuclear material safeguards that enables the NRC to ensure that SNM is controlled and accounted for. SNM, per 10 CFR Part 74, refers to plutonium, 233 U, and uranium enriched in the isotope 233 U or 235 U, but does not include source material. Periodic physical inventories, coupled with material balance evaluations, are effective and demonstrated tools to account for and detect theft or diversion of SNM in facilities containing SNM in bulk material form (i.e., not in discrete, countable items). Historically in the United States, these types of facilities have included fuel fabrication, conversion, and enrichment facilities. In comparison, reactors have relied on item counting of assemblies and control of SNM while in containment (e.g., a sealed reactor pressure vessel) because, to date, reactor fuel has been in item form. In liquid-fueled molten salt reactors (MSRs), unlike traditional light water reactors (LWRs) or bulk facilities, bulk SNM quantities can change significantly during operation as a result of depletion and transmutation. This introduces challenges to the use of traditional periodic physical inventories and material balance evaluations to detect theft or diversion of SNM in reactors that use SNM in bulk material form. Liquid-fueled (i.e., salt-fueled) MSR facilities are MSRs that use SNM within a salt eutectic as the fuel. The SNM is in a bulk material form any time it is outside of fresh or spent fuel storage containers. Some examples of when SNM will be in bulk form in the facility are during addition of fuel to the reactor system, while fuel is circulating in operation, and while fuel is in a drain tank. Periodic physical inventories and material balance evaluations can likely be effectively applied to many portions of an MSR facility, including all areas where depletion and transmutation are not significantly changing the quantities of SNM within the control area. Within an MSR facility, this would include fresh fuel receipt and loading, waste streams that may contain SNM, irradiated fuel storage outside of the reactor core, and any irradiated fuel processing that may happen after SNM has been removed from the reactor. All of these process steps could rely on measurements of SNM quantities compared with documented inventories. Any discrepancies from predicted (i.e., book) inventories and measured inventories could be quantified as inventory differences, consistent with traditional MC&A guidance from the NRC (e.g., in NUREG-1065 Revision 2, NUREG-2159 Revision 1, and RG 5.29 Revision 2). Within the reactor system, additions and removals to the book inventory include depletion of the SNM (e.g., fission of 235 U), which complicates the use of physical inventories. SNM control, however, can also likely be effectively applied to detect theft of SNM throughout a liquid-fueled MSR facility. To complement these approaches, prior technical reports have identified that a diversion path analysis may be a useful, risk-informed, and performance-based tool to determine suitable elements of an MC&A approach for the reactor system within a liquid-fueled MSR facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solenoidal Fields from Permanent Magnets for a Polarized Electron Preinjector

This technical note describes the design of a compact focusing solenoid constructed from permanent bar magnets, intended for the low-energy section of a spin-polarized electron injector. Typically, quadrupole triplets provide appropriate focusing for the low-energy spin rotator section; however, their large footprint precludes the insertion of sufficient beam diagnostics. The primary motivation of this study is to provide beam focusing while preserving the vertical spin orientation of the electron beam. We propose a solenoidal field composed of multiple permanent magnets arranged to naturally yield a zero longitudinal magnetic field integral ($\int B_zdz = 0$). This design serves as a compact, passive, and non-coupling alternative to traditional quadrupole triplets. We present the magnet arrangement, field calculation methodology, spin tracking simulations using space charge codes, and calculations demonstrating that the required field strength is achievable.

43 PARTICLE ACCELERATORS↗

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Materials for NGNP/Gen IV

The bounding conditions were briefly summarized for the Next Generation Nuclear Plant (NGNP) that is the leading candidate in the Department of Energy Generation IV reactor program. Metallic materials essential to the successful development and proof of concept for the NGNP were identified. The literature bearing on the materials technology for high-temperature gas-cooled reactors was reviewed with emphasis on the needs identified for the NGNP. Several materials were identified for a more thorough study of their databases and behavioral features relative to the requirements ASME Boiler and Pressure Vessel Code, Section III, Division 1, Subsection NH.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing Price-Informed Operation of a Battery Storage System in an Office Building

New prescriptive efficiency requirements amended to US model energy codes historically have been evaluated using an average, blended electricity rate, which obscures demand charges. Post 2019, new measures can be evaluated using a representative time-of-use (TOU) tariff yet more sophisticated analysis methods are needed to consider a variety of TOU tariffs and assess price-informed control. To address these needs, this study couples building prototype simulation model with varying-in-sophistication battery storage operating strategies for different electricity TOU tariffs. The analysis compares the impact of operating a battery storage system following simpler rule-of-thumb methods versus a semi-optimized priced-informed heuristic approach. The investigation demonstrates that the heuristic approach results in greater electricity cost savings and is practical to implement.

Lei, Xuechen↗

Non-isobaric Thermal Instability

Multiphase media have very complex structure and evolution. Accurate numerical simulations are necessary to make advances in our understanding of this rich physics. Because simulations can capture both the linear and nonlinear evolution of perturbations with a relatively wide range of sizes, it is important to thoroughly understand the stability of condensation and acoustic modes between the two extreme wavelength limits of isobaric and isochoric instability as identified by Field. Partially motivated by a recent suggestion that large non-isobaric clouds can "shatter" into tiny cloudlets, we revisit the linear theory to survey all possible regimes of thermal instability. We uncover seven regimes in total, one of which allows three unstable condensation modes. Using the code Athena++, we determine the numerical requirements to properly evolve small amplitude perturbations of the entropy mode into the nonlinear regime. Here, our 1D numerical simulations demonstrate that for a typical AGN cooling function, the nonlinear evolution of a single eigenmode in an isobarically unstable plasma involves increasingly larger amplitude oscillations in cloud size, temperature, and density as the wavelength increases. Such oscillations are the hallmark behavior of non-isobaric multiphase gas dynamics and may be observable as correlations between changes in brightness and the associated periodic redshifts and blueshifts in systems that can be spatially resolved. Intriguingly, we discuss regimes and derive characteristic cloud sizes for which the saturation process giving rise to these oscillations can be so energetic that the cloud may indeed break apart. However, we dub this process "splattering" instead of "shattering," as it is a different fragmentation mechanism that is triggered when the cloud suddenly "lands" on the stable cold branch of the equilibrium curve.

79 ASTRONOMY AND ASTROPHYSICS↗

A new method for diagnosing effective radiative forcing from aerosol–cloud interactions in climate models

Aerosol–cloud interactions (ACIs) are a leading source of uncertainty in estimates of the historical effective radiative forcing (ERF). One reason for this uncertainty is the difficulty in estimating the ERF from aerosol–cloud interactions (ERFaci) in climate models, which typically requires multiple calls to the radiation code. Most commonly used methods also cannot disentangle the contributions from different processes to ERFaci. Here, we develop a new, computationally efficient method for estimating the shortwave (SW) ERFaci from liquid clouds using histograms of monthly averaged cloud fraction partitioned by cloud droplet effective radius (r e ) and liquid water path (LWP). Multiplying the histograms with SW cloud radiative kernels gives the total SW ERFaci from liquid clouds, which can be decomposed into contributions from the Twomey effect, LWP adjustments, and cloud fraction (CF) adjustments. We test the method with data from five CMIP6-era models, using the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite instrument simulator to generate the histograms. Our method gives similar total SW ERFaci estimates to other established methods in regions of prevalent liquid cloud and indicates that the Twomey effect, LWP adjustments, and CF adjustments have contributed -0.34 ± 0.23, -0.22 ± 0.13, and -0.09 ± 0.11 W m -2 , respectively, to the effective radiative forcing of the climate since 1850 in the ensemble mean (95 % confidence). These results demonstrate that widespread adoption of a MODIS r e –LWP joint histogram diagnostic would allow the SW ERFaci and its components to be quickly and accurately diagnosed from climate model outputs, a crucial step for reducing uncertainty in the historical ERF.

54 ENVIRONMENTAL SCIENCES↗

A model-independent data assimilation (MIDA) module and its applications in ecology

Abstract. Models are an important tool to predict Earth system dynamics. An accurate prediction of future states of ecosystems depends on not only model structures but also parameterizations. Model parameters can be constrained by data assimilation. However, applications of data assimilation to ecology are restricted by highly technical requirements such as model-dependent coding. To alleviate this technical burden, we developed a model-independent data assimilation (MIDA) module. MIDA works in three steps including data preparation, execution of data assimilation, and visualization. The first step prepares prior ranges of parameter values, a defined number of iterations, and directory paths to access files of observations and models. The execution step calibrates parameter values to best fit the observations and estimates the parameter posterior distributions. The final step automatically visualizes the calibration performance and posterior distributions. MIDA is model independent, and modelers can use MIDA for an accurate and efficient data assimilation in a simple and interactive way without modification of their original models. We applied MIDA to four types of ecological models: the data assimilation linked ecosystem carbon (DALEC) model, a surrogate-based energy exascale earth system model: the land component (ELM), nine phenological models and a stand-alone biome ecological strategy simulator (BiomeE). The applications indicate that MIDA can effectively solve data assimilation problems for different ecological models. Additionally, the easy implementation and model-independent feature of MIDA breaks the technical barrier of applications of data–model fusion in ecology. MIDA facilitates the assimilation of various observations into models for uncertainty reduction in ecological modeling and forecasting.

58 GEOSCIENCES↗

New Whole-House Solutions Case Study: The Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut

By working with builder partners on test homes, researchers from the U.S. Department of Energy’s Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 “Performance House” was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the “Performance House” were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

accessibility↗

Building America Top Innovations 2012: Building Science-Based Climate Maps

This Building America Top Innovations profile describes the Building America-developed climate zone map, which serves as a consistent framework for energy-efficiency requirements in the national model energy code starting with the 2004 IECC Supplement and the ASHRAE 90.1 2004 edition. The map also provides a critical foundation for climate-specific guidance in the widely disseminated EEBA Builder Guides and Building America Best Practice Guides.