Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Assessment of Spatial Uncertainties in the Radiotherapy Process With the Novalis System

Purpose: The purpose of this study was to evaluate the accuracy of a new version of the ExacTrac X-ray (ETX) system with statistical analysis retrospectively in order to determine the tolerance of systematic components of spatial uncertainties with the Novalis system. Methods and Materials: Three factors of geometrical accuracy related to the ETX system were evaluated by phantom studies. First, location dependency of the detection ability of the infrared system was evaluated. Second, accuracy of the automated calculation by the image fusion algorithm in the patient registration software was evaluated. Third, deviation of the coordinate scale between the ETX isocenter and the mechanical isocenter was evaluated. From the values of these examinations and clinical experiences, the total spatial uncertainty with the Novalis system was evaluated. Results: As to the location dependency of the detection ability of the infrared system, the detection errors between the actual position and the detected position were 1% in translation shift and 0.1{sup o} in rotational angle, respectively. As to the accuracy of patient verification software, the repeatability and the coincidence of the calculation value by image fusion were good when the contrast of the X-ray image was high. The deviation of coordinates between the ETX isocenter and the mechanical isocenter was 0.313 {+-} 0.024 mm, in a suitable procedure. Conclusions: The spatial uncertainty will be less than 2 mm when suitable treatment planning, optimal patient setup, and daily quality assurance for the Novalis system are achieved in the routine workload.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Fast Reactor Physics Model Verification Studies using ARC and PyARC Workflows

PyARC was recently developed at Argonne National Laboratory to automate many of the tasks required in the ARC (Argonne Reactor Computation) fast reactor simulation workflow, from input file generation, code execution, data transfer between ARC codes, and output postprocessing. PyARC will likely be the path forward to train new users of the ARC codes with the goal of wide adoption by the national laboratories, academia, and industry. In particular, for the ANL-JAEA collaboration under the Civil Nuclear Working Group (CNWG) project agreement NE-01, PyARC will be used to model the Joyo and EBR-II reactors for comparisons with measured data and calculated results from JAEA (Task 3: Fast Reactor Fuel and Core). As an additional avenue for verification and validation, this report investigates the use of PyARC towards a variety of existing ARC-based reactor models, in order to understand its efficacy in replicating the behavior of base ARC codes and better understand any limitations within modeling realistic fast reactor problems. To this end, PyARC was used to model the Joyo MKI, RBEC Benchmark-M, PRISM Mod-B, and EBR-II Run 138B cores, and its results were compared to those from existing ARC-based models. It was found that for hexagonal-based geometries PyARC was able to replicate the behavior of ARC codes to within 10 pcm for small reactor cores, and ~150pcm difference in eigenvalue for larger cores. These discrepancies are attributed primarily to differences in local mesh refinement options between ARC and PyARC, which currently cannot be resolved with PyARC’s latest version (1.6.0). In some of these cases, PyARC was used to model steady-state problems with initial core compositions originating from a prior REBUS depletion calculation. While PyARC was not designed to support such steady-state calculations, workarounds were applied to replicate the behavior of ARC-based calculations as closely as possible. Thus, these results demonstrate the wide extent to which they can be applied to fast reactor problems while still providing immense benefit to the user in terms of automating and standardizing common routines within the fast reactor analysis workflow. This study concluded that PyARC will be suitable for modeling the steady-state conditions of the EBR-II and Joyo fast reactors as part of the CNWG project agreement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-DE-201-02: A Statistical Analysis Tool for Plan Quality Verification in HDR Brachytherapy Forward Planning for Cervix Cancer

Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginal mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.

60 APPLIED LIFE SCIENCES↗

Determine Operating Reactor to Use for the 2016 PCI Level 1 Milestone

The Consortium for Advanced Simulation of Light Water Reactors (LWRs) (CASL) Level 1 milestone to “Assess the analysis capability for core-wide [pressurized water reactor] PWR Pellet- Clad Interaction (PCI) screening and demonstrate detailed 3-D analysis on selected sub-region” (L1:CASL.P13.03) requires a particular type of nuclear power plant for the assessment. This report documents the operating reactor and cycles chosen for this assessment in completion of the physics integration (PHI) milestone to “Determine Operating Reactor to use for PCI L1 Milestone” (L3:PHI.CMD.P12.02). Watts Bar Unit 1 experienced (at least) one fuel rod failure in each of cycles 6 and 7, and at least one was deemed to be duty related rather than being primarily related to a manufacturing defect or grid effects. This brief report documents that the data required to model cycles 1–12 of Watts Bar Unit 1 using VERA-CS contains sufficient data to model the PHI portion of the PCI challenge problem. A list of additional data needs is also provided that will be important for verification and validation of the BISON results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

SU-E-T-762: Toward Volume-Based Independent Dose Verification as Secondary Check

Purpose: Lung SBRT plan has been shifted to volume prescription technique. However, point dose agreement is still verified using independent dose verification at the secondary check. The volume dose verification is more affected by inhomogeneous correction rather than point dose verification currently used as the check. A feasibility study for volume dose verification was conducted in lung SBRT plan. Methods: Six SBRT plans were collected in our institute. Two dose distributions with / without inhomogeneous correction were generated using Adaptive Convolve (AC) in Pinnacle3. Simple MU Analysis (SMU, Triangle Product, Ishikawa, JP) was used as the independent dose verification software program, in which a modified Clarkson-based algorithm was implemented and radiological path length was computed using CT images independently to the treatment planning system. The agreement in point dose and mean dose between the AC with / without the correction and the SMU were assessed. Results: In the point dose evaluation for the center of the GTV, the difference shows the systematic shift (4.5% ± 1.9 %) in comparison of the AC with the inhomogeneous correction, on the other hands, there was good agreement of 0.2 ± 0.9% between the SMU and the AC without the correction. In the volume evaluation, there were significant differences in mean dose for not only PTV (14.2 ± 5.1 %) but also GTV (8.0 ± 5.1 %) compared to the AC with the correction. Without the correction, the SMU showed good agreement for GTV (1.5 ± 0.9%) as well as PTV (0.9% ± 1.0%). Conclusion: The volume evaluation for secondary check may be possible in homogenous region. However, the volume including the inhomogeneous media would make larger discrepancy. Dose calculation algorithm for independent verification needs to be modified to take into account the inhomogeneous correction.

60 APPLIED LIFE SCIENCES↗

Gamma Source Verification for GAMSRC and GAMSOR

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gamma Source Verification for GAMSRC and GAMSOR

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interactions. The GAMSOR program was first built in the mid 1980s to properly account for the gamma heating in an operating reactor core on core internals. The GAMSOR code is sequence of DIF3D calculations to compute the neutron and gamma flux and combine them to define both the neutron and gamma heating throughout the modeled domain. The goal of this manuscript is to present the software verification of GAMSOR. The first step of the GAMSOR sequence of calculations involves of a modified version of DIF3D (called DIF3D-GAMSOR) which generates a gamma source distribution for the follow-on DIF3D gamma transport calculation (step 2). This modified version of DIF3D increases the burden of maintenance and verification work on GAMSOR as one must reverify the DIF3D capabilities which is undesirable. Because the calculation of the gamma source is the only unique aspect of GAMSOR beyond the regular DIF3D capabilities, that part was put in a standalone code called GAMSRC such that one can use the verified DIF3D code in step 1 followed by GAMSRC to carry out the same GAMSOR calculation step. As a consequence, this manuscript is focused on verification of the gamma source files generated by GAMSRC. The verification of the modified version of DIF3D (DIF3D-GAMSOR) will be done less rigorously in that it will be verified that it produces the same output that GAMSRC does and thus GAMSRC is equivalent to GAMSOR on the problems studied here. Hand calculations and independent numerical calculations of the gamma source generation are used for the verification work. This work follows the same methodology of GAMSRC. As expected, the results agree well with those calculated by GAMSRC as will be shown.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and verification of the pyIsoDep depletion package for nuclear thermal propulsion reactors

Nuclear thermal propulsion technology is currently being developed by the National Air and Space Administration for future manned Mars missions. There are multiple on-going activities to develop and enhance computational capabilities, single- and multi-physics, to advance the readiness level of this technology. The prediction of short-lived fission products is crucial to understand the reactivity penalty and the decay heat production during the different burnout stages of the vehicle. Generally, the solution entails coupled neutronic-depletion analysis. However, such simulations are somewhat expensive, especially if the duration of each engine burn is to be optimized. Therefore, there is a need to complement such high-fidelity techniques with time-efficient alternatives that do not require the sequential neutronic and depletion analysis. This paper details the methods and capabilities of pyIsoDep, an open-source code used for depletion analysis of nuclear thermal propulsion reactors. The package is general, in principle, and thus can be applied to any fission system, and can potentially be extended for fusion systems. The package was developed to provide a flexible and efficient alternative to pre-existing higher order depletion codes that could integrate well into mission and transient analysis of nuclear thermal propulsion reactors. Finally, this paper presents a validation and verification of pyIsoDep against analytical and Serpent-generated solutions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TU-G-BRD-01: Quantifying the Effectiveness of the Physics Pre-Treatment Plan Review for Detecting Errors in Radiation Therapy

Purpose: Physics pre-treatment plan review is crucial to safe radiation oncology treatments. Studies show that most errors originate in treatment planning, which underscores the importance of physics plan review. As a QA measure the physics review is of fundamental importance and is central to the profession of medical physics. However, little is known about its effectiveness. More hard data are needed. The purpose of this study was to quantify the effectiveness of physics review with the goal of improving it. Methods: This study analyzed 315 “potentially serious” near-miss incidents within an institutional incident learning system collected over a two-year period. 139 of these originated prior to physics review and were found at the review or after. Incidents were classified as events that: 1)were detected by physics review, 2)could have been detected (but were not), and 3)could not have been detected. Category 1 and 2 events were classified by which specific check (within physics review) detected or could have detected the event. Results: Of the 139 analyzed events, 73/139 (53%) were detected or could have been detected by the physics review; although, 42/73 (58%) were not actually detected. 45/73 (62%) errors originated in treatment planning, making physics review the first step in the workflow that could detect the error. Two specific physics checks were particularly effective (combined effectiveness of >20%): verifying DRRs (8/73) and verifying isocenter (7/73). Software-based plan checking systems were evaluated and found to have potential effectiveness of 40%. Given current data structures, software implementations of some tests such as isocenter verification check would be challenging. Conclusion: Physics plan review is a key safety measure and can detect majority of reported events. However, a majority of events that potentially could have been detected were NOT detected in this study, indicating the need to improve the performance of physics review.

60 APPLIED LIFE SCIENCES↗

STAT7 v1.2 Verification and Validation Report

This report documents the software testing which has been performed for the STAT7 Version 1.2 (hereafter STAT7 v1.2) software, a code for the statistical propagation of uncertainties in steady-state thermal hydraulics (TH) analysis of plate-fueled research and test reactors. The key capabilities addressed in this testing were selected based on the use of the software for analysis work supporting the conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors (USHPRR) such as the Massachusetts Institute of Technology Research Reactor (MITR-II). This testing scope includes comparison of the code’s statistical processing capabilities using statistical tests, comparison of coolant property evaluations to NIST data tables, and systematic comparison of key TH solver capabilities to the results of hand calculations and to predictions from PLTEMP/ANL Version 4.4. The good agreement achieved in this testing campaign, within the acceptance criteria of a 1% relative difference, also demonstrates that these capabilities have been implemented in STAT7 v1.2 correctly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary verification of the MCNP perturbation and fixed-source tally sensitivity tools

Integral benchmark experiments are vital in the adjustment and validation of the nuclear data that govern predictive simulations across the nuclear community. The nuclear data sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®) transport code are currently limited; however, expanding sensitivity capabilities will allow benchmark experiments to be designed to resolve compensating errors and adjust nuclear data where previously prohibitively difficult. This paper provides details of a preliminary verification for the use of (i.) the recently revised perturbation and (ii.) developmental fixed-source sensitivity tools within MCNP to calculate sensitivities of tallied responses (such as current integrated over a surface, F1, and flux averaged over a cell, F4) to nuclear data in fixed-source simulations. Energy-binned and energy-integrated sensitivities calculated with these tools are compared against sensitivities calculated using a central-difference approximation. Here, the verification is completed for four configurations of a benchmarked system using a 4.5-kg plutonium sphere surrounded by varying amounts of copper and/or polyethylene. The results show that sensitivities calculated with the perturbation and fixed-source sensitivity tools agree with the central-difference-based approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-268: A Feasibility Study of Independent Dose Verification for Vero4DRT

Purpose: Vero4DRT (Mitsubishi Heavy Industries Ltd.) has been released for a few years. The treatment planning system (TPS) of Vero4DRT is dedicated, so the measurement is the only method of dose verification. There have been no reports of independent dose verification using Clarksonbased algorithm for Vero4DRT. An independent dose verification software program of the general-purpose linac using a modified Clarkson-based algorithm was modified for Vero4DRT. In this study, we evaluated the accuracy of independent dose verification program and the feasibility of the secondary check for Vero4DRT. Methods: iPlan (Brainlab AG) was used as the TPS. PencilBeam Convolution was used for dose calculation algorithm of IMRT and X-ray Voxel Monte Carlo was used for the others. Simple MU Analysis (SMU, Triangle Products, Japan) was used as the independent dose verification software program in which CT-based dose calculation was performed using a modified Clarkson-based algorithm. In this study, 120 patients’ treatment plans were collected in our institute. The treatments were performed using the conventional irradiation for lung and prostate, SBRT for lung and Step and shoot IMRT for prostate. Comparison in dose between the TPS and the SMU was done and confidence limits (CLs, Mean ± 2SD %) were compared to those from the general-purpose linac. Results: As the results of the CLs, the conventional irradiation (lung, prostate), SBRT (lung) and IMRT (prostate) show 2.2 ± 3.5% (CL of the general-purpose linac: 2.4 ± 5.3%), 1.1 ± 1.7% (−0.3 ± 2.0%), 4.8 ± 3.7% (5.4 ± 5.3%) and −0.5 ± 2.5% (−0.1 ± 3.6%), respectively. The CLs for Vero4DRT show similar results to that for the general-purpose linac. Conclusion: The independent dose verification for the new linac is clinically available as a secondary check and we performed the check with the similar tolerance level of the general-purpose linac. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

COMBINE7.1 - A Portable ENDF/B-VII.0 Based Neutron Spectrum and Cross-Section Generation Program

COMBINE7.1 is a FORTRAN 90 computer code that generates multigroup neutron constants for use in the deterministic diffusion and transport theory neutronics analysis. The cross-section database used by COMBINE7.1 is derived from the Evaluated Nuclear Data Files (ENDF/B-VII.0). The neutron energy range covered is from 20 MeV to 1.0E-5 eV. The Los Alamos National Laboratory NJOY code is used as the processing code to generate a 167 fine-group cross-section library in MATXS format for Bondarenko self-shielding treatment. Resolved resonance parameters are extracted from ENDF/B-VII.0 File 2 for a separate library to be used in an alternate Nordheim self-shielding treatment in the resolved resonance energy range. The equations solved for energy dependent neutron spectrum in the 167 fine-group structure are the B-3 or B-1 approximations to the transport equation. The fine group cross sections needed for the spectrum calculation are first prepared by Bondarenko self-shielding interpolation in terms of background cross section and temperature. The geometric lump effect, when present, is accounted for by augmenting the background cross section. Nordheim self-shielded fine group cross sections for a material having resolved resonance parameters overwrite correspondingly the existing self-shielded fine group cross sections when this option is used. The fine group cross sections in the thermal energy range are replaced by those self-shielded with the Amouyal/Benoist/Horowitz method in the three region geometry when this option is requested. COMBINE7.1 coalesces fine group cross sections into broad group macroscopic and microscopic constants. The coalescing is performed by utilizing fine-group fluxes and/or currents obtained by spectrum calculation as the weighting functions. The multigroup constant may be output in any of several standard formats including ANISN 14** free format, CCCC ISOTXS format, and AMPX working library format. ANISN-PC, a one-dimensional, discrete-ordinate transport code, is incoprated into COMBINE7.1. As an option, the 167 fine-group constants generated by COMBINE portion in the program can be used to cacluate regionwise spectra in the ANISN portion, all internally to reflect the one-dimensional transport correction. Results for the criticality validation calculations are included as a part of verification and validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IAEA Coordinated Research Project on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis

The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of HTGR design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The predictive capability of coupled neutronics/thermal-hydraulics and depletion simulations for reactor design and safety analysis can be assessed with sensitivity analysis (SA) and uncertainty analysis (UA) methods. Uncertainty originates from errors in physical data, manufacturing uncertainties, modelling and computational algorithms. (The interested reader is referred to the large body of published SA and UA literature for a more complete overview of the various types of uncertainties, methodologies and results obtained). SA is helpful for ranking the various sources of uncertainty and error in the results of core analyses. SA and UA are required to address cost, safety, and licensing needs and should be applied to all aspects of reactor multi-physics simulation. SA and UA can guide experimental, modelling, and algorithm research and development. Current SA and UA rely either on derivative-based methods such as stochastic sampling methods or on generalized perturbation theory to obtain sensitivity coefficients. Neither approach addresses all needs. In order to benefit from recent advances in modelling and simulation and the availability of new covariance data (nuclear data uncertainties) extensive sensitivity and uncertainty studies are needed for quantification of the impact of different sources of uncertainties on the design and safety parameters of HTGRs. Only a parallel effort in advanced simulation and in nuclear data improvement will be able to provide designers with more robust and well validated calculation tools to meet design target accuracies. In February 2009, the Technical Working Group on Gas-Cooled Reactors (TWG-GCR) of the International Atomic Energy Agency (IAEA) recommended that the proposed Coordinated Research Program (CRP) on the HTGR Uncertainty Analysis in Modelling (UAM) be implemented. This CRP is a continuation of the previous IAEA and Organization for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA) international activities on Verification and Validation (V&V) of available analytical capabilities for HTGR simulation for design and safety evaluations. Within the framework of these activities different numerical and experimental benchmark problems were performed and insight was gained about specific physics phenomena and the adequacy of analysis methods.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementing Faraday effect measurement constraints into the Grad–Shafranov equilibrium fitting code EFIT

A new tool for the exploration and diagnosis of the internal magnetic field of plasmas in the DIII-D tokamak in the form of a constraint on the EFIT (Equilibrium Fitting) Grad–Shafranov code based on the Faraday-effect Radial Interferometer-Polarimeter (RIP) diagnostic is presented, including description, verification, and sample application. The physics underlying the diagnostic and its implementation into EFIT are discussed, and the results showing the verification of the model are given, and the model’s limitations are discussed. The influence of the diagnostic’s input on the resulting equilibrium parameters is characterized. Furthermore, the effect of electron density profile refinement is evaluated and found to be negligible. A sample application of the diagnostic is shown, indicating that the RIP constraint has similar effects on the equilibrium as motional Stark effect constraints do.

47 OTHER INSTRUMENTATION↗

A Structural Design Approach Tailored for the Rapid Preliminary Design of Microreactor Components

High-temperature microreactors can play a role in developing reliable, portable energy sources for off-grid remote locations, microgrid concepts, and industrial process heat. Portability and passive safety criteria tend to skew microreactor structural component designs toward complex geometries, high thermal stresses, and design bases with large numbers of startup/shutdown cycles. Current design rules, as typified by Section III of the American Society of Mechanical Engineers (ASME) Boiler & Pressure Vessel Code, are less than optimal for these conditions, particularly for preliminary component designs where developers need to rapidly consider a large number of potential component configurations. This paper presents a design method targeted toward rapid, efficient evaluation of preliminary component designs using modern finite element analysis. The new method retains key connections with the ASME Code rules and design data while streamlining the design approach. This paper presents the design method, several verification examples illustrating the similarities and differences between the new method and the current ASME rules, and the application of the new approach to the evaluation of a test article mimicking key features of a heat pipe–cooled microreactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗