Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Radiation Templates of Spent Fuel in Casks

BNL and INL propose to perform a scoping study, using heavily collimated gamma and fast neutron detectors, to obtain passive radiation templates of dry storage casks containing spent fuel. The goal is to demonstrate sufficient spatial resolution and sensitivity to detect a missing fuel assembly. Such measurements, combined with detailed modeling and decay corrections should provide confidence that the cask contents have not been altered, despite loss of continuity of knowledge (CoK). The concept relies on the leakage of high energy gammas and neutrons through the shielding of the casks. Tests will emphasize organic scintillators with pulse shape discrimination, but baseline comparisons will be made to high purity germanium (HPGe) and collimated moderated 3He detectors deployed in the same locations. Commercial off-the-shelf (COTS) detectors and data acquisition electronics will be used with custom-built collimators and shielding.

36 MATERIALS SCIENCE↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

FAST, LOW-IONIZATION EMISSION REGIONS OF THE PLANETARY NEBULA M2-42

Spatially resolved observations of the planetary nebula M2-42 (PN G008.2−04.8) obtained with the Wide Field Spectrograph on the Australian National University 2.3 m telescope have revealed the remarkable features of bipolar collimated jets emerging from its main structure. Velocity-resolved channel maps derived from the [N ii] λ6584 emission line disentangle different morphological components of the nebula. This information is used to develop a three-dimensional morpho-kinematic model, which consists of an equatorial dense torus and a pair of asymmetric bipolar outflows. The expansion velocity of about 20 km s{sup −1} is measured from the spectrum integrated over the main shell. However, the deprojected velocities of the jets are found to be in the range of 80–160 km s{sup −1} with respect to the nebular center. It is found that the mean density of the collimated outflows, 595 ± 125 cm{sup −3}, is five times lower than that of the main shell, 3150 cm{sup −3}, whereas their singly ionized nitrogen and sulfur abundances are about three times higher than those determined from the dense shell. The results indicate that the features of the collimated jets are typical of fast, low-ionization emission regions.

79 ASTRONOMY AND ASTROPHYSICS↗

The Mochi LabJet Experiment for Measurements of Canonical Helicity Injection in a Laboratory Astrophysical Jet

The Mochi device is a new pulsed power plasma experiment designed to produce long, collimated, stable, magnetized plasma jets when set up in the LabJet configuration. The LabJet configuration aims to simulate an astrophysical jet in the laboratory by mimicking an accretion disk threaded by a poloidal magnetic field with concentric planar electrodes in front of a solenoidal coil. The unique setup consists of three electrodes, each with azimuthally symmetric gas slits. Two of the electrodes are biased independently with respect to the third electrode to control the radial electric field profile across the poloidal bias magnetic field. This design approximates a shear azimuthal rotation profile in an accretion disk. The azimuthally symmetric gas slits provide a continuously symmetric mass source at the footpoint of the plasma jet, so any azimuthal rotation of the plasma jet is not hindered by a discrete number of gas holes. The initial set of diagnostics consists of current Rogowski coils, voltage probes, magnetic field probe arrays, an interferometer and ion Doppler spectroscopy, supplemented by a fast ion gauge and a retarding grid energy analyzer. The measured parameters of the first plasmas are ~10 22 m -3 , ~0.4 T, and 5–25 eV, with velocities of ~20–80 km s -1 . Finally, the combination of a controllable electric field profile, a flared poloidal magnetic field, and azimuthally symmetric mass sources in the experiment successfully produces short-lived (~10 μs, ≳5 Alfvén times) collimated magnetic jets with a ~10:1 aspect ratio and long-lived (~100 μs, ≳40 Alfvén times) flow-stabilized, collimated, magnetic jets with a ~30:1 aspect ratio.

42 ENGINEERING↗

Instrumentation for the measurement of high energy phenomena on NASA spacecraft.

High energy astrophysical observations will be conducted primarily from the Small Astronomy Satellites (SAS) and the High Energy Astronomy Observatories (HEAO). The first satellite (SAS A) will carry a set of collimated proportional counters to conduct a high sensitivity, high spatial resolution, all sky survey for X-ray sources. The objective of SAS B will be to search for celestial gamma-ray sources and regions and to measure the flux and energy spectrum of any sources located. A wire grid digitized spark chamber will be the prime detection instrument. The instrumentation of SAS C will consist of modulation collimators, slot collimators, and proportional counters.

Opp, A. G.↗

Dual acting slit control mechanism

A dual acting control system for mass spectrometers is described, which permits adjustment of the collimating slit width and centering of the collimating slit while using only one vacuum penetration. Coaxial shafts, each with independent vacuum bellows are used to independently move the entire collimating assembly or to adjust the slit dimension through a parallelogram linkage.

Struthoff, G. L.↗

Studies of auroral X-ray imaging from high altitude spacecraft

Results of a study of techniques for imaging the aurora from a high altitude satellite at X-ray wavelengths are summarized. The X-ray observations allow the straightforward derivation of the primary auroral X-ray spectrum and can be made at all local times, day and night. Five candidate imaging systems are identified: X-ray telescope, multiple pinhole camera, coded aperture, rastered collimator, and imaging collimator. Examples of each are specified, subject to common weight and size limits which allow them to be intercompared. The imaging ability of each system is tested using a wide variety of sample spectra which are based on previous satellite observations. The study shows that the pinhole camera and coded aperture are both good auroral imaging systems. The two collimated detectors are significantly less sensitive. The X-ray telescope provides better image quality than the other systems in almost all cases, but a limitation to energies below about 4 keV prevents this system from providing the spectra data essential to deriving electron spectra, energy input to the atmosphere, and atmospheric densities and conductivities. The orbit selection requires a tradeoff between spatial resolution and duty cycle.

Mckenzie, D. L.↗

Dual laser optical system and method for studying fluid flow

A dual laser optical system and method is disclosed for visualization of phenomena in transport substances which induce refractive index gradients such as fluid flow and pressure and temperature gradients in fluids and gases. Two images representing mutually perpendicular components of refractive index gradients may be viewed simultaneously on screen. Two lasers having wave lengths in the visible range but separated by about 1000 angstroms are utilized to provide beams which are collimated into a beam containing components of the different wave lengths. The collimated beam is passed through a test volume of the transparent substance. The collimated beam is then separated into components of the different wave lengths and focused onto a pair of knife edges arranged mutually perpendicular to produce and project images onto the screen.

Owen, R. B.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

Space shuttle molecular and wake vacuum measurements

The wake environment of the space shuttle is analyzed to determine whether it is feasible to perform ultrahigh vacuum experiments in or near the payload bay with the shuttle oriented such that the payload bay faces the antivelocity direction. Several mechanisms were considered by which molecules could approach the payload bay from this direction and their relative contributions to the wake environment are estimated. These mechanisms include ambient atmospheric molecules that have velocities in excess of the orbital velocity which can overtake the shuttle, ambient atmospheric molecules that are backscattered by collisions with the shuttle induced atmosphere, and self scattering from the induced atmosphere. These estimates are compared with the measurements made with the collimated mass spectrometer which was part of the Induced Environment Contamination Monitor flown on several of the early shuttle flights. Although the collimated mass spectrometer was not designed for this purpose and the instrument background for the species for which the collimator is effective is above the expected levels, upper limits can be established for these species in the wake environment which are consistent with the analysis. There was considerably more helium and argon observed in the wake direction than was predicted, however. Possible origins of these gases are discussed.

Naumann, R. J.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

High resolution observations of the L1551 bipolar outflow

The nearby dark cloud Lynds 1551 contains one of the closest examples of a well-collimated bipolar molecular outflow. This source has the largest angular size of any known outflow and was the first bipolar outflow to be detected. The outflow originates from a low-luminosity young stellar object, IRS-5. Optical and radio continuum observations show the presence of a highly collimated, ionized stellar wind orginating from close to IRS-5 and aligned with the molecular outflow. However, we have little information on the actual mechanism that generates the stellar wind and collimates it into opposed jets. The Very Large Array (VLA) observations indicate that the winds originate within 10(15) cm of IRS-5, unfortunately at a size scale difficult to resolve. For these reasons, observations of the structure and dynamics of the hypersonic molecular gas may provide valuable information on the origin and evolution of these outflows. In addition, the study of the impact of the outflowing gas on the surrounding molecular material is essential to understand the consequence these outflows have on the evolution and star formation history of the entire cloud. Moriarty-Schieven et al. (1986) obtained a oversampled map of the CO emission of a portion of both the blueshifted and redshifted outflows in LI551 using Five College Radio Astronomy Observatory 14 m telescope. The oversampled maps have been reconstructed to an effective angular resolution of 20 arcsec using a maximum entropy algorithm. A continuation of the study of Moriarty-Schieven et al. is presented. The entire L1551 outflow has now been mapped at 12 arcsec sampling requiring roughly 4000 spectra. This data has been constructed to 20 arcsec resolution to provide the first high resolution picture of the entire L1551 outflow. This new data has shown that the blueshifted lobe is more extended than previously thought and has expanded downstream sufficiently to break out of the dense molecular cloud, but the redshifted outflow is still confined within the molecular cloud. Details of the structure and kinematics of the high velocity gas are used to test the various models of the origin and evolution of outflows.

Snell, R.↗

Asymptotic structure of hydromagnetically driven relativistic winds

A fully relativistic analysis has been performed of the asymptotic structure of stationary axisymmetric hydromagnetic winds. If a flow fills the region containing the rotation axis, then the flux surfaces in the flow must collimate to a set of current-carrying cylindrical surface extending to infinite transverse radius, collimate to a set of cylindrical surfaces extending to a finite radius, or collimate to a current-free paraboloidal field configuration which fills up the entire space. If an asymptotically cylindrical flow carries a finite current at radii well beyond the light cylinder, then the Lorentz factor of the terminal flow speed on a given flux surface is proportional to the total current enclosed within this flux surface. If a flow is of type II paraboloidal, then its asymptotic energy flux is carried entirely by the gas motion rather than the electromagnetic fields.

Chiueh, Tzihong↗

Experimental study of solar simulator mirror cryocontamination

The background and tasks formulation of the study of Solar Simulator collimation mirror cryocontamination in Large Thermal Vacuum Facility are outlined, research methods and experiment procedures are described, experimental relationships obtained are analyzed and practical recommendations are given. The accepted procedure of thermal vacuum tests as a rule defines the sequence of operations for verifying the spacecraft under test without taking into account measures for preventing Solar Simulator collimation mirror contamination and degradation. On the other hand, evacuation procedures is defined for conditions of achieving the required vacuum in the shortest possible time with using the available evacuation equipment at a regime close to the optimum one. Similarly, cryopanel cooling down cyclogram and test object preparation process are not analyzed from the viewpoint of ways of reducing environmental detrimental effects on thermal vacuum facility contamination-sensitive systems. Solar Simulator mirror contamination and its reflective characteristics change results in degradation of solar flux parameters and reduction of simulator continuous operation time. Methods of consideration of optical effects due to mirror surface contamination are actually missing. The effects themselves are not quite understood and data cited in literature as a rule, were obtained under conditions different from real thermal vacuum facility and therefore should be subjected to additional experimental verification. Only in the last few years contamination effect on optical surfaces degradation has been considered with using empirical relations. Mirror reflective properties degradation leads to the increase of Solar Simulator errors. This ultimately has an adverse effect on S/C ground development, schedule and cost of thermal vacuum tests. Besides, the mirror maintenance in operable state becomes more expensive. The present paper is dedicated to the study of Solar Simulator collimation mirror contamination and to the search of ways for improving the mirror design and thermal vacuum test procedure. On the basis of tests performed, recommendations are devised on reducing chamber inner-optical surfaces cryocontamination and degradation.

Galjaev, V. L.↗

Simulation of gamma-ray spectra for a variety of user-specified detector designs

The gamma-ray spectrum simulation program BSIMUL was designed to allow the operator to follow the path of a gamma-ray through a detector, shield and collimator whose dimensions are entered by the operator. It can also be used to simulate spectra that would be generated by a detector. Several improvements have been made to the program within the last few months. The detector, shield and collimator dimensions can now be entered through an interactive menu whose options are discussed below. In addition, spectra containing more than one gamma-ray energy can now be generated with the menu - for isotopes listed in the program. Adding isotopes to the main routine is also quite easy. Subroutines have been added to enable the operator to specify the material and dimensions of a collimator. This report details the progress made in simulating gamma-ray spectra for a variety of user-specified detector designs. In addition, a short discussion of work done in the related areas of pulse shape analysis and the spectral analysis is included. The pulse shape analysis and spectral analysis work is being performed pursuant to the requirements of contract F-94-C-0006, for the Advanced Research Projects Agency and the U.S. Air Force.

Rester, A. C., Jr.↗

A comparison between using incoherent or coherent sources to align and test an adaptive optical telescope

The concept in the initial alignment of the segmented mirror adaptive optics telescope called the phased array mirror extendable large aperture telescope (Pamela) is to produce an optical transfer function (OTF) which closely approximates the diffraction limited value which would correspond to a system pupil function that is unity over the aperture and zero outside. There are differences in the theory of intensity measurements between coherent and incoherent radiation. As a result, some of the classical quantities which describe the performance of an optical system for incoherent radiation can not be defined for a coherent field. The most important quantity describing the quality of an optical system is the OTF and for a coherent source the OTF is not defined. Instead a coherent transfer function (CTF) is defined. The main conclusion of the paper is that an incoherent collimated source and not a collimated laser source is preferred to calibrate the Hartmann wavefront sensor (WFS) of an aligned adaptive optical system. A distant laser source can be used with minimum problems to correct the system for atmospheric turbulence. The collimation of the HeNe laser alignment source can be improved by using a very small pin hole in the spatial filter so only the central portion of the beam is transmitted and the beam from the filter is nearly constant in amplitude. The size of this pin hole will be limited by the sensitivity of the lateral effect diode (LEDD) elements.

Anderson, Richard↗

Ionization cones and radio ejecta in active galaxies

We report radio mapping at three frequencies of the Seyfert 2 galaxy NGC 5252, which is known to exhibit a spectacular pair of 'ionization cones' in optical emission-line images. The radio structure of the galaxy comprises an unresolved (less than 50 pc) source coincident with the optical nucleus, weak, narrow features extending approximately equal to 900 pc to north and south from the nucleus, and an unresolved radio source some 10 kpc from the nucleus. The inner parts of the extended radio structure and the off-nuclear source align well with the axis of the ionization cones. There are currently 11 Seyfert galaxies known to possess an ionization cone or a bi-cone; 8 of these galaxies also contain a linear (double, triple, or jet-like) nuclear radio structure. For this limited, incomplete sample, there is a tight alignment between cone and radi axes: the formal mean difference between the measured projections of these axes on the sky is only 6 deg, and the alignment may well be better than this at the location(s) closer to the nucleus where the collimation occurs. Although the degree of collimation is much worse for the ionizing photons than for the radio plasma, it is clear that they are collimated by the same, or coplanar, nulcear disks or tori. In particular, if the ionization cones result from absorption by dusty tori on the pc scale and the radio ejecta from accretion disks around the central black hole, the absence of differential precession indicates that either the gravitating mass distribution is close to spherical or the dusty torus has settled into a preferred plane. The cones currently known in late-type (but not early-type) spirals show a trend to align with the axis of the galaxy stellar disk. We argue that this alignment is either an observational selection effect or indicates that the gas accreted to power the nuclear activity has an internal origin in late-type spirals, but may have an external origin (e.g., a galaxy merger) in early-types. .

Wilson, A. S.↗