At least 973 records · Page 54

Preliminary modeling of triply periodic minimal surface (TPMS) structures using RELAP5-3D

With the United States Department of Energy (DOE)’s goal of quadrupling the nation’s nuclear energy supply by 2050, and with the Advanced Fuels Campaign pushing for new types of advanced reactor fuels and geometries, the need has arisen for new nuclear fuel designs. One such design is to swap out current nuclear fuel geometries in exchange for another type of geometry, called a Triply Periodic Minimal Surface (TPMS). TPMSs are self-supporting, infinitely repeating lattices—attributes that lend themselves well to additive manufacturing. These surfaces also possess enhanced heat transfer properties thanks to their internal area changes and large surface-area-to-volume ratios. Their drawback, however, is an increased pressure drop. Given the small amount of correlations and data (Reynolds numbers in the 2,000–8,000 range), and the minimal amount of experience so far obtained by modeling TPMS structures using 1D systems codes such as the Reactor Excursion and Leak Analysis Program (RELAP5-3D), further research into this topic was needed. Using data from the University of Wisconsin - Madison (UW), curve fits were created for both a Heat Transfer Coefficient (HTC) correlation and a Darcy friction factor empirical coefficient correlation. The curves’ coefficients and multipliers were then output and utilized in RELAP5-3D models of two upcoming experiments—Flow Loop for INFLUX Pressure drop (FLIP) and Microreactor Agile Non-nuclear Experimental Test (MAGNET)—aimed at increasing the available data for Reynolds numbers to the 16,000–36,000 range for TPMS structures. The models were run under the conditions utilized by a Computational Fluid Dynamics (CFD) analysis performed by another group at Idaho National Laboratory. Only CFD pressure drop values were obtained from the FLIP test, and those values showed that the RELAP5-3D models had a lower rate of pressure increase in comparison to the CFD values. In addition, there seemed to be a vertical shift upward in the pressure drop for both models whenever the TPMS porosity decreased, and the RELAP5-3D models showed a higher vertical shift in comparison to the CFD values. The MAGNET results did not correspond to any CFD or experimental results against which they could be compared, so they were instead compared against the proposed CFD input conditions. These values were then compared with each other to make sure the model seemed to be performing as expected, paving the way for future tests that can be run for the purpose of further analyses and comparisons. The pressure drop increased with temperature and mass flow rate independently. The temperature change would decrease with increasing mass flow rate and temperature, which was just as we expected based on the fact that the lower viscosity and decreased density would result in higher friction and churning losses. The last metric that was assessed was the enthalpy flow change, which increased with increasing mass flow rate and decreasing temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved neutron-gamma discrimination for a {sup 6}Li-glass neutron detector using digital signal analysis methods

A {sup 6}Li-glass scintillator (GS20) based neutron Anger camera was developed for time-of-flight single-crystal diffraction instruments at Spallation Neutron Source. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio (defined as NGD ratio) on the order of 10{sup 4}. The NGD ratios of Anger cameras need to be improved for broader applications including neutron reflectometers. For this purpose, six digital signal analysis methods of individual waveforms acquired from photomultiplier tubes were proposed using (i) charge integration, (ii) pulse-amplitude histograms, (iii) power spectrum analysis combined with the maximum pulse-amplitude, (iv) two event parameters (a{sub 1}, b{sub 0}) obtained from a Wiener filter, (v) an effective amplitude (m) obtained from an adaptive least-mean-square filter, and (vi) a cross-correlation coefficient between individual and reference waveforms. The NGD ratios are about 70 times those from the traditional PHA method. Our results indicate the NGD capabilities of neutron Anger cameras based on GS20 scintillators can be significantly improved with digital signal analysis methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flight and Stability of a Laser Inertial Fusion Energy Target in the Drift Region between Injection and the Reaction Chamber with Computational Fluid Dynamics

A Laser Inertial Fusion Energy (LIFE) target’s flight through a low Reynolds number and high Mach number regime was analyzed with computational fluid dynamics software. This regime consisted of xenon gas at 1,050 K and approximately 6,670 Pa. Simulations with similar flow conditions were performed with a sphere and compared with experimental data and published correlations for validation purposes. Transient considerations of the developing flow around the target were explored. Simulations of the target at different velocities were used to determine correlations for the drag coefficient and Nusselt number as functions of the Reynolds number. Simulations with different angles of attack were used to determine the aerodynamic coefficients of drag, lift, Magnus moment, and overturning moment as well as target stability. The drag force, lift force, and overturning moment changed minimally with spin. Above an angle of attack of 15°, the overturning moment would be destabilizing. At low angles of attack (less than 15°), the overturning moment would tend to decrease the target’s angle of attack, indicating the lack of a need for spin for stability at small angles. This stabilizing moment would cause the target to move in a mildly damped oscillation about the axis parallel to the free-stream velocity vector through the target’s center of gravity.

42 ENGINEERING↗

Checking nonflow assumptions and results via PHENIX published correlations in p+p, p+Au, d+Au, and 3 He+Au at √ s NN=200 GeV

Recently the PHENIX Collaboration has made available two-particle correlation Fourier coefficients for multiple detector combinations in minimum bias p+p and 0–5% central p+Au, d+Au, and 3 He+Au collisions at √ s NN = 200 GeV [Phys. Rev. C 105, 024901 (2022)]. Using these coefficients for three sets of two-particle correlations, azimuthal anisotropy coefficients v 2 and v 3 are extracted for midrapidity charged hadrons as a function of transverse momentum. In this paper, we use the available coefficients to explore various nonflow hypotheses as well as to compare the results with theoretical model calculations. The nonflow methods fail basic closure tests with ampt and pythia/angantyr, particularly when including correlations with particles in the low multiplicity light-projectile going direction. In data, the nonflow adjusted v 2 results are modestly lower in p+Au and the adjusted v 3 results are more significantly higher in p+Au and d+Au. However, the resulting higher values for the ratio v 3 /v 2 in p+Au at RHIC compared to p+Pb at the LHC is additional evidence for a significant overcorrection. Incorporating these additional checks, the conclusion that these flow coefficients are dominated by initial geometry coupled with final-state interactions (e.g., hydrodynamic expansion of quark-gluon plasma) remains true, and explanations based solely on initial-state glasma are ruled out. The detailed balance between intrinsic and fluctuation-driven geometry and the exact role of weakly versus strongly coupled prehydrodynamic evolution remains an open question for triangular flow, requiring further theoretical and experimental investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-65: A Prospective Trial of Open Face Masks for Head and Neck Radiotherapy

Purpose: Open face head and neck masks allow for active patient monitoring during treatment and may reduced claustrophobia and anxiety compared to closed masks. The ability of open masks to limit intrafraction motion and to preserve the patient shape/position from simulation over protracted treatments should be considered. Methods: Thirty-two head and neck patients were prospectively randomized to treatment in a closed mask or a novel open face mask. All patients received daily volumetric imaging. The daily images were automatically rigidly registered to the planning CT’s offline using a commercial image processing tool. The shifts needed to optimize the registration, the mutual information coefficient (MI), and the Pearson correlation (PC) coefficients were recorded to evaluate shape preservation. The open group was set-up and monitored with surface imaging at treatment. The real time surface imaging information was recorded to evaluate intrafraction motion. Results: Sixteen patients were included in each group. Evaluations were made over a total of 984 fractions. The mean MI and PC showed significantly higher shape preservation for the open group than for the closed group (p = 0). The mean rotations for the open group were smaller or < 0.15° larger versus the closed group. The mean intrafraction motion for the open group was 0.93 +/−0.99 mm (2 SD). The maximum single fraction displacement was 3.2 mm. Fourteen of 16 patients showed no significant correlation of motion with fraction number (p > 0.05). Conclusion: The open masks preserved shape as well as the closed masks, and they limited motion to < 2 mm for 95% of the treated fractions. These results are consistent over treatment courses of up to 35 fractions. The open mask is suitable for treatment with or without active monitoring. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

Biologically Effective Dose (BED) Correlation With Biochemical Control After Low-Dose Rate Prostate Brachytherapy for Clinically Low-Risk Prostate Cancer

Purpose: To assess the correlation of postimplant dosimetric quantifiers with biochemical control of prostate cancer after low-dose rate brachytherapy. Methods and Materials: The biologically effective dose (BED), dose in Gray (Gy) to 90% of prostate (D{sub 90}), and percent volume of the prostate receiving 100% of the prescription dose (V{sub 100}) were calculated from the postimplant dose-volume histogram for 140 patients undergoing low-dose rate prostate brachytherapy from 1997 to 2003 at Durham Regional Hospital and the Durham VA Medical Center (Durham, NC). Results: The median follow-up was 50 months. There was a 7% biochemical failure rate (10 of 140), and 91% of patients (127 of 140) were alive at last clinical follow-up. The median BED was 148 Gy (range, 46-218 Gy). The median D{sub 90} was 139 Gy (range, 45-203 Gy). The median V{sub 100} was 85% (range, 44-100%). The overall 5-year biochemical relapse-free survival (bRFS) rate was 90.1%. On univariate Cox proportional hazards modeling, no pretreatment characteristic (Gleason score sum, age, baseline prostate-specific antigen, or clinical stage) was predictive of bRFS. The BED, D{sub 90}, and V{sub 100} were all highly correlated (Pearson coefficients >92%), and all were strongly correlated with bRFS. Using the Youden method, we identified the following cut points for predicting freedom from biochemical failure: D{sub 90} >= 110 Gy, V{sub 100} >= 74%, and BED >= 115 Gy. None of the covariates significantly predicted overall survival. Conclusions: We observed significant correlation between BED, D{sub 90}, and V{sub 100} with bRFS. The BED is at least as predictive of bRFS as D{sub 90} or V{sub 100}. Dosimetric quantifiers that account for heterogeneity in tumor location and dose distribution, tumor repopulation, and survival probability of tumor clonogens should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlating conductivity and Seebeck coefficient to doping within crystalline and amorphous domains in poly(3-(methoxyethoxyethoxy)thiophene)

Molecular doping of conjugated polymers (CPs) plays a vital role in optimizing organic electronic and energy applications. For the case of organic thermoelectrics, it is commonly believed that doping CPs with a strong dopant could result in higher conductivity (σ) and thus better power factor (PF). Herein, by investigating thermoelectric performance of a polar side-chain bearing CP, poly(3- (methoxyethoxyethoxy)thiophene) (P3MEET), vapor doped with fluorinatedderivative of tetracyanoquinodimethane FnTCNQ (n = 1, 2, 4), we show that using strong dopants can in fact have detrimental effects on the thermoelectric performance of CPs. Despite possessing higher electron affinity, doping P3MEET with F4TCNQ only results in a σ (27.0 S/cm) comparable to samples doped with other two weaker dopants F2TCNQ and F1TCNQ (26.4 and 20.1 S/cm). Interestingly, F4TCNQ-doped samples display a marked reduction in the Seebeck coefficient (α) compared to F1TCNQ- and F2TCNQ-doped samples from 42 to 13 μV/ K, leading to an undesirable suppression of the PF. Additionally, structural characterizations coupled with Kang-Snyder modeling of the α–σ relation show that the reduction of α in F4TCNQ-doped P3MEET samples originates from the generation of low mobility carrier within P3MEET's amorphous domain. Our results demonstrate that factors such as dopant distribution and doping efficiency within the crystalline and amorphous domains of CPs should play a crucial role in advancing rational design for organic thermoelectrics.

36 MATERIALS SCIENCE↗

Theory and Implementation of Nuclear Safety System Codes - Part II: System Code Closure Relations, Validation, and Limitations

This is Part II of two articles describing the details of thermal-hydraulic sys- tem codes. In this second part of the article series, the system code closure relationships (used to model thermal and mechanical non-equilibrium and the coupling of the phases) for the governing equations are discussed and evaluated. These include several thermal and hydraulic models, such as heat transfer coefficients for various flow regimes, two phase pressure correlations, two phase friction correlations, drag coefficients and interfacial models be- tween the fields. These models are often developed from experimental data. The experiment conditions should be understood to evaluate the efficacy of the closure models. Code verification and validation, including Separate Effects Tests (SETs) and Integral effects tests (IETs) is also assessed. It can be shown from the assessments that the test cases cover a significant section of the system code capabilities, but some of the more advanced reactor designs will push the limits of validation for the codes. Lastly, the limitations of the codes are discussed by considering next generation power plants, such as Small Modular Reactors (SMRs), analyz- ing not only existing nuclear power plants, but also next generation nuclear power plants. The nuclear industry is developing new, innovative reactor designs, such as Small Modular Reactors (SMRs), High-Temperature Gas-cooled Reactors (HTGRs) and others. Sub-types of these reactor designs utilize pebbles, prismatic graphite moderators, helical steam generators, in- novative fuel types, and many other design features that may not be fully analyzed by current system codes. This second part completes the series on the comparison and evaluation of the selected reactor system codes by discussing the closure relations, val- idation and limitations. These two articles indicate areas where the models can be improved to adequately address issues with new reactor design and development.

99 GENERAL AND MISCELLANEOUS↗

New correlation to predict the heat transfer coefficient in-tube cooling of supercritical CO{sub 2} in horizontal macro-tubes

The heat transfer coefficient during gas cooling process of supercritical CO{sub 2} without lubricating oil in horizontal macro-tubes has experimentally investigated. Investigation has done on two stainless steel circular tubes having inside-diameter of 4.55 mm and 7.75 mm and carried out for CO{sub 2} mass fluxes of 200-600 kg/m{sup 2} s, inlet fluid pressures of 7.5-10.0 MPa, and the inlet fluid temperatures of 90-100 C. The experimental results indicate that the gas cooling pressure, the inner tube diameter, the mass flux and the temperature of CO{sub 2} have significant effects on the heat transfer coefficient, especially near pseudo-critical region. The heat transfer coefficient decreases as the cooling pressure increases otherwise increases as mass flux increases. At any temperatures, smaller inner tube diameter shows higher heat transfer coefficient. In comparison between present experimental data and existing correlations from references, most of supercritical heat transfer correlations show large deviations with this present experimental data. Therefore, based on experimental data obtained in this present work, a new correlation is proposed to predict more accurate heat transfer coefficient of supercritical CO{sub 2} in horizontal macro-tubes under cooling conditions. The majority of the experimental values are within 13% of the values predicted by the new correlation. (author)

42 ENGINEERING↗

Low-Field Nuclear Magnetic Resonance Characterization of Carbonate and Sandstone Reservoirs From Rock Spring Uplift of Wyoming

Laboratory measurements including gas (N 2 ) porosity and permeability, time-domain nuclear magnetic resonance, thin section, and scanning electron microscopy analysis were conducted to obtain petrographical and petrophysical descriptions of the Weber Sandstone and Madison Limestone at the Rock Spring Uplift, a potential carbon dioxide storage site in Southwestern Wyoming. The relationships between pore structures, such as pore geometry, pore-size distribution, pore network, and porosity/permeability are investigated. First, using thin sections combined with scanning electron microscopy for pore structures description, all samples are described in detail from the geological, petrographysical, and diagenetic viewpoint. Results show that within the Madison Limestone, pore types include intercrystalline, vuggy, moldic, or mixed (combination of all other pore types). Both moldic and vuggy pore types are associated with samples of high porosity and permeability. Nuclear magnetic resonance relaxation time distributions show either bimodal or multimodal distributions. Large relaxation time components are associated with samples with large pores, whereas small components are dominated by small pores. The T 2 geometric mean correlates well with gas permeability. Additionally, short-time diffusion coefficients (D) were measured by pulsed field gradient method using a series of gradient strengths. We found that diffusion coefficient distributions correlate with the corresponding T 2 distributions for macropores. By comparing the dominant peak position of T 2 distributions and their corresponding diffusion coefficient distributions, we predicted the surface relaxivity of different rock types. We found that surface relaxivities of Weber Sandstone samples can be well predicted, while for Madison Limestone samples, surface relaxivities are overestimated due to diffusive pore coupling effect.

58 GEOSCIENCES↗

Reliability-guided digital image correlation for image deformation measurement

A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pretreatment Apparent Diffusion Coefficient of the Primary Lesion Correlates With Local Failure in Head-and-Neck Cancer Treated With Chemoradiotherapy or Radiotherapy

Purpose: This study was performed to evaluate whether the apparent diffusion coefficient (ADC) of a primary lesion correlates with local failure in primary head-and-neck squamous cell carcinoma (HNSCC) treated with chemoradiotherapy or radiotherapy. Methods and Materials: We retrospectively studied 38 patients with primary HNSCC (12 oropharynx, 20 hypopharynx, 4 larynx, 2 oral cavity) treated with chemoradiotherapy or radiotherapy with radiation dose to gross tumor volume equal to or over 60 Gy and who underwent pretreatment magnetic resonance imaging, including diffusion-weighted imaging. Ten patients developed local failure during follow-up periods of 2.0 to 9.3 months, and the remaining 28 showed local control during follow-up periods of 10.5 to 31.7 months. The variables that could affect local failure (age, tumor volume, ADC, T stage, N stage, dose, treatment method, tumor location, and overall treatment time) were analyzed using logistic regression analyses for all 38 patients and for 17 patients with Stage T3 or T4 disease. Results: In univariate logistic analysis for all 38 cases, tumor volume, ADC, T stage, and treatment method showed significant (p < 0.05) associations with local failure. In multivariate analysis, ADC and T stage revealed significance (p < 0.01). In univariate logistic analysis for the 17 patients with Stage T3 or T4 disease, ADC and dose showed significant (p < 0.01) associations with local failure. In multivariate analysis, ADC alone showed significance (p < 0.05). Conclusions: The results suggest that pretreatment ADC, along with T stage, is a potential indicator of local failure in HNSCC treated with chemoradiotherapy or radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implications of the recent high statistics determination of the pion electromagnetic form factor in the timelike region

The recently evaluated two-pion contribution to the muon g-2 and the phase of the pion electromagnetic form factor in the elastic region, known from {pi}{pi} scattering by Fermi-Watson theorem, are exploited by analytic techniques for finding correlations between the coefficients of the Taylor expansion at t=0 and the values of the form factor at several points in the spacelike region. We do not use specific parametrizations, and the results are fully independent of the unknown phase in the inelastic region. Using for instance, from recent determinations, <r{sub {pi}}{sup 2}>=(0.435{+-}0.005) fm{sup 2} and F(-1.6 GeV{sup 2})=0.243{sub -0.014}{sup +0.022}, we obtain the allowed ranges 3.75 GeV{sup -4} < or approx. c < or approx. 3.98 GeV{sup -4} and 9.91 GeV{sup -6} < or approx. d < or approx. 10.46 GeV{sup -6} for the curvature and the next Taylor coefficient, with a strong correlation between them. We also predict a large region in the complex plane where the form factor cannot have zeros.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-669: Commissioning of An Electronic Brachytherapy System for Targeted Mouse Irradiation

Purpose: The aim of this study was to commission the Xoft Axxent™ electronic brachytherapy (eBT) source and 10 mm diameter surface applicator with NIST traceability for targeted irradiations of mouse anal carcinomas. Methods: The Xoft Axxent™ electronic brachytherapy (eBT) and 10 mm diameter surface applicator was chosen by the collaborating physician as a radiation delivery mechanism for mouse anal carcinomas. The target dose was 2 Gy at a depth of 3 mm in tissue to be delivered in a single fraction. To implement an accurate and reliable irradiation plan, the system was commissioned by first determining the eBT source output and corresponding dose rate at a depth of 3 mm in tissue. This was determined through parallel-plate ion chamber measurements and published conversion factors. Well-type ionization chamber measurements were used to determine a transfer coefficient, which correlates the measured dose rate at 3 mm to the NIST-traceable quantity, air-kerma rate at 50 cm in air, for eBT sources. By correlating these two quantities, daily monitoring in the well chamber becomes an accurate and efficient quality assurance technique. Once the dose-rate was determined, a treatment recipe was developed and confirmed with chamber measurements to deliver the requested dose. Radiochromic film was used to verify the dose distribution across the field. Results: Dose rates at 3 mm depth in tissue were determined for two different Xoft Axxent™ sources and correlated with NIST-traceable well-type ionization chamber measurements. Unique transfer coefficients were determined for each source and the treatment recipe was validated by measurements. Film profiles showed a uniform dose distribution across the field. Conclusion: A Xoft Axxent™ eBT system was successfully commissioned for use in the irradiation of mouse rectal tumors. Dose rates in tissue were determined as well as other pertinent parameters to ensure accurate delivery of dose to the target region.

60 APPLIED LIFE SCIENCES↗

Development and Evaluation of a General Drag Model for Gas-Solid Flows via Deep Learning

This project presents the development and evaluation of a general drag model for gas–solid multiphase flows using deep learning techniques. A comprehensive database of more than 4,000 experimental and numerical data points for spherical and non spherical particles was compiled, incorporating geometric features such as sphericity, aspect ratio, and orientation. Several predictive approaches—including traditional em pirical correlations, machine learning, and deep neural networks—were benchmarked, with the proposed Drag Coefficient Correlation-aided Deep Neural Network (DCC DNN) demonstrating superior accuracy. To account for particle–particle interactions, additional drag data were generated using CFD-based simulations of packed and flu idized beds, leading to the development of a retrained model capable of incorporat ing volume fraction effects. Integration of the trained model with the MFiX CFD solver was achieved using FTorch, enabling drag predictions during discrete element method (DEM) simulations. Validation against experimental data for single particles and fluidized beds confirmed the model’s improved predictive ability, particularly for non-spherical geometries. While the model performed strongly under fluidized con ditions, limitations remained in unfluidized regimes, suggesting a need for expanded datasets. Overall, this study demonstrates the feasibility of combining deep learning with physics-informed CFD to improve drag modeling for gas–solid flows, with promis ing implications for scaling multiphase simulations in industrial applications.

42 ENGINEERING↗