Search NASA⌕ Search

SEARCH · Search NASA

Results for “dilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A Kernel-Free Particle-Finite Element Method for Hypervelocity Impact Simulation

An improved hybrid particle-finite element method has been developed for the simulation of hypervelocity impact problems. Unlike alternative methods, the revised formulation computes the density without reference to any kernel or interpolation functions, for either the density or the rate of dilatation. This simplifies the state space model and leads to a significant reduction in computational cost. The improved method introduces internal energy variables as generalized coordinates in a new formulation of the thermomechanical Lagrange equations. Example problems show good agreement with exact solutions in one dimension and good agreement with experimental data in a three dimensional simulation.

Park, Young-Keun↗

Abnormalities in intracellular calcium regulation and contractile function in myocardium from dogs with pacing-induced heart failure

24 d of rapid ventricular pacing induced dilated cardiomyopathy with both systolic and diastolic dysfunction in conscious, chronically instrumented dogs. We studied mechanical properties and intracellular calcium (Ca2+i) transients of trabeculae carneae isolated from 15 control dogs (n = 32) and 11 dogs with pacing-induced cardiac failure (n = 26). Muscles were stretched to maximum length at 30 degrees C and stimulated at 0.33 Hz; a subset (n = 17 control, n = 17 myopathic) was loaded with the [Ca2+]i indicator aequorin. Peak tension was depressed in the myopathic muscles, even in the presence of maximally effective (i.e., 16 mM) [Ca2+] in the perfusate. However, peak [Ca2+]i was similar (0.80 +/- 0.13 vs. 0.71 +/- 0.05 microM; [Ca2+]o = 2.5 mM), suggesting that a decrease in Cai2+ availability was not responsible for the decreased contractility. The time for decline from the peak of the Cai2+ transient was prolonged in the myopathic group, which correlated with prolongation of isometric contraction and relaxation. However, similar end-diastolic [Ca2+]i was achieved in both groups (0.29 +/- 0.05 vs. 0.31 +/- 0.02 microM), indicating that Cai2+ homeostasis can be maintained in myopathic hearts. The inotropic response of the myopathic muscles to milrinone was depressed compared with the controls. However, when cAMP production was stimulated by pretreatment with forskolin, the response of the myopathic muscles to milrinone was improved. Our findings provide direct evidence that abnormal [Ca2+]i handling is an important cause of contractile dysfunction in dogs with pacing-induced heart failure and suggest that deficient production of cAMP may be an important cause of these changes in excitation-contraction coupling.

Non-NASA Center↗

Resistance to outflow of cerebrospinal fluid after central infusions of angiotensin

Infusions of artificial cerebrospinal fluid (CSF) into the cerebroventricles of conscious rats can raise CSF pressure (CSFp). This response can be modified by some neuropeptides. One of these, angiotensin, facilitates the rise in CSFp. We measured CSFp in conscious rats with a computerized system and evaluated resistance to CSF outflow during infusion of artificial CSF, with or without angiotensin, from the decay kinetics of superimposed bolus injections. Angiotensin (10 ng/min) raised CSFp (P less than 0.05) compared with solvent, but the resistance to CSF outflow of the two groups was similar (P greater than 0.05). Because CSFp was increased by angiotensin without an increase in the outflow resistance, a change in some volume compartment is likely. Angiotensin may raise CSFp by increasing CSF synthesis; this possibility is supported, since the choroid plexuses contain an intrinsic isorenin-angiotensin system. Alternatively, angiotensin may dilate pial arteries, leading to an increased intracranial blood volume.

NASA Discipline Cardiopulmonary↗

Discovery of an Afterglow Extension of the Prompt Phase of Two Gamma Ray Bursts Observed by Swift

Contemporaneous BAT and XRT observations of two recent well-covered GRBs observed by Swift, GRB 050315 and GRB 050319, show clearly a prompt component of the afterglow emission. The rapid slewing capability of the spacecraft enables X-ray observations immediately after the burst, typically approximately 100 s following the initiation of the prompt gamma-ray phase. By fitting a power law form to the gamma-ray spectrum, we extrapolate the time dependent fluxes measured by the BAT, in the energy band 15 - 350 keV, into the spectral regime observed by the XRT, 0.2 - 10 keV, and examine the functional form of the rate of decay of the two light curves. We find that the BAT and XRT light curves merge to form a unified curve. There is a period of steep decay up to approximately 300 s, followed by a flatter decay. The duration of the steep decay, approximately 100 s in the source frame after correcting for cosmological time dilation, agrees with a theoretical estimate for the deceleration time of the relativistic ejecta as it interacts with circumstellar material. For GRB 050315, the steep decay can be characterized by an exponential form, where T(sub e),(BAT)approximately equal to 24 plus or minus 2 s, and T(sub e)(XRT) approximately equal to 35 plus or minus 2 s. For GRB 050319 a power law decay -d lnf/d lnt = n, where n approximately equal to 3, provides a reasonable fit. The early time X-ray fluxes are consistent with representing the lower energy tail of the prompt emission, and provide our first quantitative measure of the decay of the prompt gamma-ray emission over a large dynamic range. The initial steep decay is expected from the high latitude emission from a curved shell of relativistic plasma illuminated only for a short interval. The overall conclusion is that the prompt phase of GRBs lasts for hundreds of seconds longer than previously thought.

Barthelmy, S. D.↗

Discovery of an Afterglow Extension of the Prompt Phase of Two Gamma Ray Bursts Observed by Swift

Contemporaneous BAT and XRT observations of two recent well-covered GRBs observed by Swift, GRB 050315 and GRB 050319, show clearly a prompt component joining the onset of the afterglow emission. The rapid slewing capability of the spacecraft enables X-ray observations immediately after the burst, typically ~ 100 s following the initiation of the prompt y-ray phase. By fitting a power law form to the y-ray spectrum, we extrapolate the time dependent fluxes measured by the BAT, in the energy band 15 - 350 keV, into the spectral regime observed by the XRT 0.2 - 10 keV, and examine the functional form of the rate of decay of the two light curves. We find that the BAT and XRT light curves merge to form a unified curve. There is a period of steep decay up to ~ 300 s, followed by a flatter decay. The duration of the steep decay, ~ 100 s in the source frame after correcting for cosmological time dilation, agrees roughly with a theoretical estimate for the deceleration time of the relativistic ejecta as it interacts with circumstellar material. For GRB 050315, the steep decay can be characterized by an exponential form, where one e-folding decay time Te (BAT)~ = 24 f 2 s, and Te,(XRT)~ = 35 f 2 s. For GRB 050319, a power law decay - d l n f / d l n t = n, where n approx. ~ = 3, provides a reasonable fit. The early time X-ray fluxes are consistent with representing the lower energy tail of the prompt emission, and provide our first quantitative measure of the decay of the prompt y-ray emission over a large dynamic range in flux. The initial steep decay is expected due to the delayed high latitude photons from a curved shell of relativistic plasma illuminated only for a short interval. The overall conclusion is that the prompt phase of GRBs remains observable for hundreds of seconds longer than previously thought.

Bathelmy, S. D.↗

Post-Launch Analysis of Swift's Gamma-Ray Burst Detection Sensitivity

The dependence of Swift#s detection sensitivity on a burst#s temporal and spectral properties shapes the detected burst population. Using s implified models of the detector hardware and the burst trigger syste m I find that Swift is more sensitive to long, soft bursts than CGRO# s BATSE, a reference mission because of its large burst database. Thu s Swift has increased sensitivity in the parameter space region into which time dilation and spectral redshifting shift high redshift burs ts.

Band, David L.↗

Oscillation Amplitude Growth for a Decelerating Object with Constant Pitch Damping

The equations governing the deceleration and oscillation of a blunt body moving along a planar trajectory are re-expressed in the form of the Euler-Cauchy equation. An analytic solution of this equation describes the oscillation amplitude growth and frequency dilation with time for a statically stable decelerating body with constant pitch damping. The oscillation histories for several constant pitch damping values, predicted by the solution of the Euler-Cauchy equation are compared to POST six degree-of-freedom (6-DoF) trajectory simulations. The simulations use simplified aerodynamic coefficients matching the Euler-Cauchy approximations. Agreement between the model predictions and simulation results are excellent. Euler-Cauchy curves are also fit through nonlinear 6-DoF simulations and ballistic range data to identify static stability and pitch damping coefficients. The model os shown to closely fit through the data points and capture the behavior of the blunt body observed in simulation and experiment. The extracted coefficients are in reasonable agreement with higher fidelity, nonlinear parameter identification results. Finally, a nondimensional version of the Euler-Cauchy equation is presented and shown to be a simple and effective tool for designing dynamically scaled experiments for decelerating blunt capsule flight.

Schoenenberger, Mark↗

Usefulness of Derived Frank Lead Parameters in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the accuracy of several known as well as newly-introduced derived Frank-lead ECG parameters in differentiating healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following derived Frank lead parameters were studied for their accuracy in detecting CAD and CM: the spatial ventricular gradient (VG), including its beat-to-beat coefficient of variability (VG CV); the spatial mean QRS (SM-QRS) and T-waves (SM-T) and their beat-to-beat coefficients of variability; the spatial ventricular activation time (VAT); the mean and maximum spatial QRS-T angles; and standard late potentials parameters (RMS40, fQRSD and LAS). Several of these parameters were accurate in discriminating between the control group and both diseased groups at p less than 0.0001. For example the fQRSD, VG CV, mean spatial QRS-T angle and VG minus SM-QRS (which is similar to the SM-T) had retrospective areas under the ROC curve of 0.78, 0.78, 0.80, and 0.84 (CAD vs. controls) and 0.93, 0.88, 0.98 and 0.99 (CM vs. controls), respectively. The single most effective parameter in discriminating between the CAD and CM groups was the spatial VAT (44 plus or minus 5.8 vs. 53 plus or minus 9.9 ms, p less than 0.0001), with an area under the ROC curve of 0.80. Since subsequent prospective analyses using new groups of patients and healthy subjects have yielded only slightly less accurate results, we conclude that derived Frank-lead parameters show great promise for potentially contributing to the development of a rapid and inexpensive resting ECG-based screening test for heart disease.

DePalma, J. L.↗

New and Improved T-wave Morphology Parameters to Differentiate Healthy Individuals from those with Cardiomyopathy and Coronary Artery Disease

We investigated the ability of several known as well as new ECG repolarization parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. The following multiple parameters of T-wave morphology (TWM) were derived via signal averaging and singular value decomposition (SVD, which yields 8 eigenvalues, rho(sub 1) greater than rho(sub 2)...greater than rho(sub 8) and studied for their retrospective accuracy in detecting underlying disease: 1) Principal component analysis ratio of the T wave (T-PCA) = 100*rho(sub 2)/rho(sub 1); 2) Relative T-wave residuum (rTWR) = 100* SIGMA (rho(sub 4)(sup 2) +...+ rho(sub 8)(sup 2)); 3) Modified complexity ratio of the T wave (T-mCR) = 100*SIGMA(rho(sub 3)(sup 2) +...+rho(sb 8) (sup 2)); and 4) Normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)/rho(sub 1)(sup 2). All TWM parameters significantly differentiated CAD from controls (p less than 0.0001), and also CM from controls (p less than 0.0001). Retrospective areas under the ROC curve were 0.77, 0.81, 0.82, and 0.83 (CAD vs. controls) and 0.93, 0.89, 0.95 and 0.96 (CM vs. controls) for T-PCA, rTWR, T-mCR and nTV respectively. The newer TWM parameters (T-mCR and nTV) thus outperformed the more established parameters (T-PCA and rTWR), presumably by putting a greater emphasis on the third T-wave eigenvalue, which in most healthy subjects has little energy compared to the first two eigenvalues. Subsequent prospective analyses have also yielded similar results, such that we conclude that diagnostic differentiation of pathology from non-pathology may be especially aided by detecting the transference of energy from the first and second T-wave eigenvalues into the third T-wave eigenvalue.

Greco, E. C.↗

Multi-channel System for Beat to Beat QT Interval Variability and its Use in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.

Starc, V.↗

Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead high-fidelity ECG employing and combining the results of several advanced ECG software techniques shows great promise as a rapid and inexpensive tool for screening of heart disease.

Schlegel, T. T.↗

Cardiovascular Adaptations to Long Duration Head-Down Tilt Bed Rest

INTRODUCTION: Orthostatic hypotension is a serious risk for crewmembers returning from spaceflight. Numerous cardiovascular mechanisms have been proposed to account for this problem, including vascular and cardiac dysfunction, which we studied during bed rest. METHODS: Thirteen subjects were studied before and during bed rest. Statistical analysis was limited to the first 49-60 days of bed rest, and compared to pre-bed rest data. Ultrasound data were collected on vascular and cardiac structure and function. Tilt testing was conducted for 30 minutes or until presyncopal symptoms intervened. RESULTS: Plasma volume was significantly reduced by day 7 of bed rest. Flow-mediated dilation in the leg was significantly increased at bed rest day 49. Arterial responses to nitroglycerin differed in the arm and leg, but did not change as a result of bed rest. Intimal-medial thickness markedly decreased at bed rest days 21, 35 and 49. Several cardiac functional parameters including isovolumic relaxation time, ejection time and myocardial performance index were significantly increased (indicating a decrease in cardiac function) during bed rest. There was a trend for decreased orthostatic tolerance following 60 days of bed rest. DISCUSSION: These data suggest that 6 head-down tilt bed rest alters cardiovascular structure and function in a pattern similar to short duration spaceflight. Additionally, the vascular alterations are primarily seen in the lower body, while vessels of the upper body are unaffected. KEY WORDS: spaceflight, orthostatic intolerance, hypotension, fluid-shift, plasma volume

Platts, Steven H.↗

Enhancement of USM3D Unstructured Flow Solver for High-Speed High-Temperature Shear Flows

Large temperature and pressure fluctuations have a profound effect on turbulence development in transonic and supersonic jets. For high-speed, high-temperature jet flows, standard turbulence models lack the ability to predict the observed mixing rate of a shear layer. Several proposals to address this deficiency have been advanced in the literature to modify the turbulence transport equations in a variety of ways. In the present study, some of the most proven and simple modifications to two-equation turbulence models have been selected and implemented in NASA's USM3D tetrahedral Navier-Stokes flow solver. The modifications include the addition of compressibility correction and pressure dilatation terms in the turbulence transport equations for high-speed flows, and the addition of a simple modification to the Boussinesq's closure model coefficient for high-temperature jets. The efficacy of the extended models is demonstrated by comparison with experimental data for two supersonic axisymmetric jet test cases at design pressure ratio.

Pandya, Mohagna J.↗

Compressibility Considerations for kappa-omega Turbulence Models in Hypersonic Boundary Layer Applications

The ability of kappa-omega models to predict compressible turbulent skin friction in hypersonic boundary layers is investigated. Although uncorrected two-equation models can agree well with correlations for hot-wall cases, they tend to perform progressively worse - particularly for cold walls - as the Mach number is increased in the hypersonic regime. Simple algebraic models such as Baldwin-Lomax perform better compared to experiments and correlations in these circumstances. Many of the compressibility corrections described in the literature are summarized here. These include corrections that have only a small influence for kappa-omega models, or that apply only in specific circumstances. The most widely-used general corrections were designed for use with jet or mixing-layer free shear flows. A less well-known dilatation-dissipation correction intended for boundary layer flows is also tested, and is shown to agree reasonably well with the Baldwin-Lomax model at cold-wall conditions. It exhibits a less dramatic influence than the free shear type of correction. There is clearly a need for improved understanding and better overall physical modeling for turbulence models applied to hypersonic boundary layer flows.

Rumsey, C. L.↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Gender-related Changes in Dorsal Hand and Foot Vein Function Following 60 Days of Head Down Bed Rest

It is well known that female astronauts are more likely to experience post-flight orthostatic hypotension and presyncope compared to male astronauts. It has been suggested that the disproportionally higher incidence of presyncope (83% of female vs. 20% male crewmembers) may be due to sex-related differences in vascular function between the upper and lower limbs. However, much of this evidence is specific to changes in resistance vessels. Given that more than 70% of the circulating blood volume resides in compliance vessels, it is conceivable that even small changes in venous function may contribute to post-flight orthostatic hypotension. In spite of this, little is currently known regarding the influence of microgravity exposure on venous function between males and females. PURPOSE: To determine the influence of 60 days of HDBR on dorsal foot and hand vein function between healthy males (M) and females (F). METHODS: Using 2-D ultrasound, dorsal hand and foot vein diameter responses to intravenous infusions phenylephrine (PE), acetylcholine (ACh), and nitroglycerine (NTG) were determined in 26 adults; 10 females (age:37 +/- 2 yr ) and 16 males (age:34 +/- 2 yr ). Changes in venous function were calculated as the difference between diameter at baseline and following each venoactive drug. Differences in venous function between limb and sexes across HDBR were determined using mixed-effects linear regression. RESULTS: In response to 60 days of HDBR, the change in venousconstrictor response to PE in the dorsal hand veins was not significantly different between M and F. Interestingly, the change in constrictor response in the dorsal foot veins (compared to pre HDBR) was approximately 30% greater in the F, whereas the constrictor response was approximately 45% less in the M (p=0.026). HDBR had no influence on the change in dilator response to ACh, or NTG between M and F and between vascular beds. CONCLUSION: These results demonstrate that 60 days of HDBR contributes to sex-related differences in venous function. Importantly, the changes are specific to dorsal foot veins and do not appear to be related to changes in endothelial or smooth muscle function. Previous data from our laboratory indicate that females have an impaired sympathetic response following HDBR. However, the results from the current investigation imply that F maintain the ability to respond to sympathetic stimulation but may not be able to adequately activate a proper response following HDBR.

Westby, Christian M.↗

CO2 Effects in Space: Relationship to Intracranial Hypertension

This slide presentation reviews the effects of enhanced exposure to CO2 on Earth and in space. The effects of enhanced exposure to CO2 are experienced in almost all bodily systems. In space some of the effects are heightened due to the fluid shifts to the thorax and head. This fluid shift results in increased intracranial pressure, congested cerebral circulation, increased Cerebral Blood Flow (CBF) and Intravenous dilatation. The mechanism of the effect of CO2 on CBF is diagrammed, as is the Cerebrospinal Fluid (CSF) production. A listing of Neuroendocrine targets is included.

Alexander, David J.↗