Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Charged particle reflection from an artificially structured boundary that produces a spatially periodic magnetostatic field

Charged particle reflection away from an artificially structured boundary is studied by computer simulation. The artificially structured boundary produces a spatially periodic static magnetic field such that the spatial period of the field is much smaller than the dimensions of a source of incident charged particles. A planar artificially structured boundary comprised of a sequence of parallel wires is considered. The wires carry currents in alternating directions and produce the magnetic field. A classical trajectory Monte Carlo study is reported. The motion of charged particles that approach the artificially structured boundary at small or grazing angles of incidence transverse to the wires is simulated. The conditions under which the charged particles reflect away from the boundary without reaching it are determined, and the results are fit to obtain analytical expressions. The results are not dependent on the sign of charge of the incident particles.

43 PARTICLE ACCELERATORS↗

Anisotropic picosecond photoconductivity caused by optical alignment of electron momenta in cubic semiconductors

Transient photoconductivity in cubic semiconductors InGaAs and InAs excited by a femtosecond laser pulse in the presence of a uniform dc electric field has been studied with the use of the Monte Carlo simulation by taking into account optical alignment of photoexcited electrons over their momenta. Simulations show that due to the optical alignment effect and energy dependence of the electron mobility, the transient photoconductivity in cubic semiconductors becomes anisotropic during the first few picoseconds after optical excitation. The magnitude of this anisotropy reaches its peak when the excess energy of the optically excited electrons approaches the threshold for the intervalley transfer. It has also been found that when the electrons are excited near the threshold energy for the intervalley transfer, the component of the transient photocurrent directed along the dc field for a short time after the end of the femtosecond optical pulse can become negative. The anisotropy of the transient photoconductivity has been investigated experimentally on (001) InGaAs sample by the optical pump - terahertz-probe technique. Optically induced changes in terahertz pulse amplitude were found to be dependent on the direction of terahertz field relative to the polarization of the optical pump pulse and to the crystallographic axes of the semiconductor. Experimental data have been explained in terms of the transient anisotropic photoconductivity and correlate with the results of the Monte Carlo simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Representational analysis of extended disorder in atomistic ensembles derived from total scattering data

With the increased availability of high-intensity time-of-flight neutron and synchrotron X-ray scattering sources that can access wide ranges of momentum transfer, the pair distribution function method has become a standard analysis technique for studying disorder of local coordination spheres and at intermediate atomic separations. In some cases, rational modeling of the total scattering data (Bragg and diffuse) becomes intractable with least-squares approaches, necessitating reverse Monte Carlo simulations using large atomistic ensembles. However, the extraction of meaningful information from the resulting atomistic ensembles is challenging, especially at intermediate length scales. Representational analysis is used here to describe the displacements of atoms in reverse Monte Carlo ensembles from an ideal crystallographic structure in an approach analogous to tight-binding methods. Rewriting the displacements in terms of a local basis that is descriptive of the ideal crystallographic symmetry provides a robust approach to characterizing medium-range order (and disorder) and symmetry breaking in complex and disordered crystalline materials. Lastly, this method enables the extraction of statistically relevant displacement modes (orientation, amplitude and distribution) of the crystalline disorder and provides directly meaningful information in a locally symmetry-adapted basis set that is most descriptive of the crystal chemistry and physics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rotational symmetry relation for efficient response function generation in the coarse mesh transport method COMET

The coarse mesh transport code COMET is a continuous energy hybrid stochastic-deterministic neutronics solver with high fidelity and formidable computation speed in solving reactor core problems. Its method is based on the incident flux expansion theory. In this work, we take advantage of the local geometric symmetry in many reactor cores lattices (e.g., fuel lattices and reflector blocks) to develop relations among the flux response expansion coefficients for symmetric surfaces to further improve the computational efficiency of the COMET response function generation tool (method). This is done by a rigorous derivation of the transformation matrices for the angular and spatial expansion moments resulting from a rotation of a coarse mesh by an arbitrary angle. The relations for the response coefficients for the symmetric surfaces can be then written as the Kronecker product of those transformation matrices. The method is implemented into COMET and tested on two advanced high temperature reactor (AHTR) full-length single assembly benchmark problems. The COMET results using the response function library based on the symmetry relations were compared to those using the library directly generated by continuous energy Monte Carlo for all surfaces. It was found that the eigenvalues and stripe-wise fission densities using the two libraries are in statistical agreement as expected. This indicates that the new method maintains the high fidelity of the original COMET method while improving the computational efficiency in the response function generation by 270% to 400%, depending on the local geometric symmetry. This method also reduces the size of the response function library by the same magnitude (270% to 400%). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fe kα profiles from simulations of accreting black holes

We present the first results from a new technique for the prediction of Fe Kα profiles directly from general relativistic magnetohydrodynamic (GRMHD) simulations. Data from a GRMHD simulation are processed by a Monte Carlo global radiation transport code, which determines the X-ray flux irradiating the disk surface and the coronal electron temperature self-consistently. With that irradiating flux and the disk’s density structure drawn from the simulation, we determine the reprocessed Fe Kα emission from photoionization equilibrium and solution of the radiation transfer equation. We produce maps of the surface brightness of Fe Kα emission over the disk surface, which—for our example of a 10M{sub ⊙} Schwarzschild black hole accreting at 1% the Eddington value—rises steeply one gravitational radius outside the radius of the innermost stable circular orbit and then falls ∝r {sup −2} at larger radii. We explain these features of the Fe Kα radial surface brightness profile as consequences of the disk’s ionization structure and an extended coronal geometry, respectively. We also present the corresponding Fe Kα line profiles as would be seen by distant observers at several inclinations. Both the shapes of the line profiles and the equivalent widths of our predicted Kα lines are qualitatively similar to those typically observed from accreting black holes. Most importantly, this work represents a direct link between theory and observation: in a fully self-consistent way, we produce observable results—iron fluorescence line profiles—from the theory of black hole accretion with almost no phenomenological assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic hierarchical coarse-graining with the inverse Monte Carlo method

We outline our coarse-graining strategy for linking micro- and mesoscales of soft matter and biological systems. The method is based on effective pairwise interaction potentials obtained in detailed ab initio or classical atomistic Molecular Dynamics (MD) simulations, which can be used in simulations at less accurate level after scaling up the size. The effective potentials are obtained by applying the inverse Monte Carlo (IMC) method [A. P. Lyubartsev and A. Laaksonen, Phys. Rev. E 52(4), 3730–3737 (1995)] on a chosen subset of degrees of freedom described in terms of radial distribution functions. An in-house software package MagiC is developed to obtain the effective potentials for arbitrary molecular systems. In this work we compute effective potentials to model DNA-protein interactions (bacterial LiaR regulator bound to a 26 base pairs DNA fragment) at physiological salt concentration at a coarse-grained (CG) level. Normally the IMC CG pair-potentials are used directly as look-up tables but here we have fitted them to five Gaussians and a repulsive wall. Results show stable association between DNA and the model protein as well as similar position fluctuation profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on space charge compensation in negative hydrogen ion beam

Negative hydrogen ion beam can be compensated by the trapping of ions into the beam potential. When the beam propagates through a neutral gas, these ions arise due to gas ionization by the beam ions. However, the high neutral gas pressure may cause serious negative hydrogen ion beam loss, while low neutral gas pressure may lead to ion-ion instability and decompensation. To better understand the space charge compensation processes within a negative hydrogen beam, experimental study and numerical simulation were carried out at Peking University (PKU). The simulation code for negative hydrogen ion beam is improved from a 2D particle-in-cell-Monte Carlo collision code which has been successfully applied to H{sup +} beam compensated with Ar gas. Impacts among ions, electrons, and neutral gases in negative hydrogen beam compensation processes are carefully treated. The results of the beam simulations were compared with current and emittance measurements of an H{sup −} beam from a 2.45 GHz microwave driven H{sup −} ion source in PKU. Compensation gas was injected directly into the beam transport region to modify the space charge compensation degree. The experimental results were in good agreement with the simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of internal energy relaxation in shocks using molecular dynamics based models

Recent potential energy surfaces (PESs) for the N{sub 2} + N and N{sub 2} + N{sub 2} systems are used in molecular dynamics (MD) to simulate rates of vibrational and rotational relaxations for conditions that occur in hypersonic flows. For both chemical systems, it is found that the rotational relaxation number increases with the translational temperature and decreases as the rotational temperature approaches the translational temperature. The vibrational relaxation number is observed to decrease with translational temperature and approaches the rotational relaxation number in the high temperature region. The rotational and vibrational relaxation numbers are generally larger in the N{sub 2} + N{sub 2} system. MD-quasi-classical trajectory (QCT) with the PESs is also used to calculate the V-T transition cross sections, the collision cross section, and the dissociation cross section for each collision pair. Direct simulation Monte Carlo (DSMC) results for hypersonic flow over a blunt body with the total collision cross section from MD/QCT simulations, Larsen-Borgnakke with new relaxation numbers, and the N{sub 2} dissociation rate from MD/QCT show a profile with a decreased translational temperature and a rotational temperature close to vibrational temperature. The results demonstrate that many of the physical models employed in DSMC should be revised as fundamental potential energy surfaces suitable for high temperature conditions become available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dressed counterions: Strong electrostatic coupling in the presence of salt

We reformulate the theory of strong electrostatic coupling in order to describe an asymmetric electrolyte solution of monovalent salt ions and polyvalent counterions using field-theoretical techniques and Monte Carlo simulations. The theory is based on an asymmetric treatment of the different components of the electrolyte solution. The weak coupling Debye-Hueckel approach is used in order to describe the monovalent salt ions while a strong coupling approach is used to tackle the polyvalent counterions. This combined weak-strong coupling approach effectively leads to dressed interactions between polyvalent counterions and thus directly affects the correlation attraction mediated by polyvalent counterions between like-charged objects. The general theory is specifically applied to a system composed of two uniformly charged plane-parallel surfaces in the presence of salt and polyvalent counterions. In the strong coupling limit for polyvalent counterions, the comparison with Monte Carlo simulations shows good agreement for large enough values of the electrostatic coupling parameter. We delineate two limiting laws that in fact encompass all the Monte Carlo data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron contamination modeling and skin dose in 6 MV longitudinal field MRIgRT: Impact of the MRI and MRI fringe field

Purpose: In recent times, longitudinal field MRI-linac systems have been proposed for 6 MV MRI-guided radiotherapy (MRIgRT). The magnetic field is parallel with the beam axis and so will alter the transport properties of any electron contamination particles. The purpose of this work is to provide a first investigation into the potential effects of the MR and fringe magnetic fields on the electron contamination as it is transported toward a phantom, in turn, providing an estimate of the expected patient skin dose changes in such a modality. Methods: Geant4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam were performed. Longitudinal magnetic fields of strengths between 0 and 3 T were applied to a 30 x 30 x 20 cm{sup 3} phantom. Surrounding the phantom there is a region where the magnetic field is at full MRI strength, consistent with clinical MRI systems. Beyond this the fringe magnetic field entering the collimation system is also modeled. The MRI-coil thickness, fringe field properties, and isocentric distance are varied and investigated. Beam field sizes of 5 x 5, 10 x 10, 15 x 15 and 20 x 20 cm{sup 2} were simulated. Central axis dose, 2D virtual entry skin dose films, and 70 {mu}m skin depth doses were calculated using high resolution scoring voxels. Results: In the presence of a longitudinal magnetic field, electron contamination from the linear accelerator is encouraged to travel almost directly toward the patient surface with minimal lateral spread. This results in a concentration of electron contamination within the x-ray beam outline. This concentration is particularly encouraged if the fringe field encompasses the collimation system. Skin dose increases of up to 1000% were observed for certain configurations and increases above Dmax were common. In nonmagnetically shielded cases, electron contamination generated from the jaw faces and air column is trapped and propagated almost directly to the phantom entry region, giving rise to intense dose hot spots inside the x-ray treatment field. These range up to 1000% or more of Dmax at the CAX, depending on field size, isocenter, and coil thickness. In the case of a fully magnetically shielded collimation system and the lowest MRI field of 0.25 T, the entry skin dose is expected to increase to at least 40%, 50%, 65%, and 80% of Dmax for 5 x 5, 10 x 10, 15 x 15, and 20 x 20 cm{sup 2}, respectively. Conclusions: Electron contamination from the linac head and air column may cause considerable skin dose increases or hot spots at the beam central axis on the entry side of a phantom or patient in longitudinal field 6 MV MRIgRT. This depends heavily on the properties of the magnetic fringe field entering the linac beam collimation system. The skin dose increase is also related to the MRI-coil thickness, the fringe field, and the isocenter distance of the linac. The results of this work indicate that the properties of the MRI fringe field, electron contamination production, and transport must be considered carefully during the design stage of a longitudinal MRI-linac system.

43 PARTICLE ACCELERATORS↗

An intermediate model for fitting triplet–triplet annihilation in phosphorescent organic light emitting diode materials

Triplet–triplet annihilation (TTA) is one of the primary contributors to efficiency roll-off and permanent material degradation in phosphorescent organic light-emitting diodes. Here, the two limiting case models typically used to quantify this quenching mechanism are multi-step Dexter and single-step Förster, which, respectively, assume ideal Fickian diffusion or perfect trapping of triplet excitons. For device-relevant guest doping levels (typically 5–12 vol. %), both significant diffusion of excitons and trapping due to spatial and energetic disorder exist, so neither conventional model fits experimental data well. We develop and validate an intermediate TTA model, which is a weighted average of the limiting cases of pure radiative decay (no TTA) and multi-step Dexter based TTA that returns an effective TTA rate constant and a parameter quantifying the portion of well-isolated excitons. Kinetic Monte-Carlo simulations and time-resolved photoluminescence measurements of an archetype host–guest system demonstrate that our intermediate model provides significantly improved fits with more realistic physical values, is more robust to variations in experimental conditions, and provides an analysis framework for the effects of trapping on TTA.

30 DIRECT ENERGY CONVERSION↗

Deciphering the Scattering of Mechanically Driven Polymers Using Deep Learning

Here, we present a deep learning approach for analyzing two-dimensional scattering data of semiflexible polymers under external forces. In our framework, scattering functions are compressed into a three-dimensional latent space using a Variational Autoencoder (VAE), and two converter networks establish a bidirectional mapping between the polymer parameters (bending modulus, stretching force, and steady shear) and the scattering functions. The training data are generated using off-lattice Monte Carlo simulations to avoid the orientational bias inherent in lattice models, ensuring robust sampling of polymer conformations. The feasibility of this bidirectional mapping is demonstrated by the organized distribution of polymer parameters in the latent space. By integrating the converter networks with the VAE, we obtain a generator that produces scattering functions from given polymer parameters and an inferrer that directly extracts polymer parameters from scattering data. While the generator can be utilized in a traditional least-squares fitting procedure, the inferrer produces comparable results in a single pass and operates 3 orders of magnitude faster. This approach offers a scalable automated tool for polymer scattering analysis and provides a promising foundation for extending the method to other scattering models, experimental validation, and the study of time-dependent scattering data.

Ding, Lijie [Oak Ridge National Laboratory (ORNL),↗

Fluorine-18-Labeled Fluoromisonidazole Positron Emission and Computed Tomography-Guided Intensity-Modulated Radiotherapy for Head and Neck Cancer: A Feasibility Study

Purpose: Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTV{sub h}) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTV{sub h} increases the tumor control probability. This study examined the feasibility of fluorine-18-labeled fluoromisonidazole positron emission tomography/computed tomography ({sup 18}F-FMISO PET/CT)-guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. Methods and Materials: {sup 18}F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and {sup 18}F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated {sup 18}F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate {sup 18}F-FMISO PET/CT-guided IMRT plans. Results: The heterogeneous distribution of {sup 18}F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing {sup 18}F-FMISO PET/CT-guided IMRT for 10 HNC patients achieved 84 Gy to the GTV{sub h} and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTV{sub h} for 2 patients and were successful in 1, with normal tissue sparing. Conclusion: It was feasible to dose escalate the GTV{sub h} to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification and Validation of High-Fidelity Multi-Physics Simulation Codes for Advanced Nuclear Reactors (Year 2)

The project objective is to verify and validate a suite of high-fidelity multi-physics simulation methods and codes developed during the previous I-NERI projects, against Monte Carlo solutions and experimental measurements for LWR and VHTR cores. Using benchmark problems developed during the previous year, ANL and KAERI continued to work on verifying the neutronics code DeCART and associated cross section libraries. Initial progress was also made on validating the code against experimental data. KAERI focused on verifying the DeCART code against numerical benchmark problems such as a PMR200 2-D pin cell/core and a HTTR 2-D block/core as well as improving DeCART capabilities such as the cross-section library group structure optimization, the fundamental and generalized adjoint equation solver, cylindrical boundary treatment, improved ray tracing, and implementing the direct resonance integral table method for resonance treatment. Verification test results for the updated capabilities showed substantial improvements in the estimation of eigenvalue and reaction rates.

Lee, C. H.↗

CTRANS: A Monte Carlo program for radiative transfer in plane parallel atmospheres with imbedded finite clouds: Development, testing and user's guide

The program called CTRANS is described which was designed to perform radiative transfer computations in an atmosphere with horizontal inhomogeneities (clouds). Since the atmosphere-ground system was to be richly detailed, the Monte Carlo method was employed. This means that results are obtained through direct modeling of the physical process of radiative transport. The effects of atmopheric or ground albedo pattern detail are essentially built up from their impact upon the transport of individual photons. The CTRANS program actually tracks the photons backwards through the atmosphere, initiating them at a receiver and following them backwards along their path to the Sun. The pattern of incident photons generated through backwards tracking automatically reflects the importance to the receiver of each region of the sky. Further, through backwards tracking, the impact of the finite field of view of the receiver and variations in its response over the field of view can be directly simulated.

Source record↗

Characteristics of nanosecond pulse needle-to-plane discharges at high pressure: a particle-in-cell Monte Carlo collision simulation

A model of one dimensional in position and three dimensional in velocity space self-consistent particle in cell with Monte Carlo collision technique was employed to simulate the argon discharge between the needle and plane electrodes at high pressure, in which a nanosecond rectangular pulse was applied to the needle electrode. The work focused on the investigation of the spatiotemporal evolution of the discharge versus the needle tip size and working gas pressure. The simulation results showed that the discharge occurred mainly in the region near the needle tip at atmospheric pressure, and that the small radius of the needle tip led to easy discharge. Reducing the gas pressure gave rise to a transition from a corona discharge to a glowlike discharge along the needle-to-plane direction. The microscopic mechanism for the transition can arguably be attributed to the peak of high-energy electrons occurring before the breakdown; the magnitude of the number of these electrons determined whether the breakdown can take place.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo implementation, validation, and characterization of a 120 leaf MLC

Purpose: Recently, the new high definition multileaf collimator (HD120 MLC) was commercialized by Varian Medical Systems providing high resolution in the center section of the treatment field. The aim of this work is to investigate the characteristics of the HD120 MLC using Monte Carlo (MC) methods. Methods: Based on the information of the manufacturer, the HD120 MLC was implemented into the already existing Swiss MC Plan (SMCP). The implementation has been configured by adjusting the physical density and the air gap between adjacent leaves in order to match transmission profile measurements for 6 and 15 MV beams of a Novalis TX. These measurements have been performed in water using gafchromic films and an ionization chamber at an SSD of 95 cm and a depth of 5 cm. The implementation was validated by comparing diamond measured and calculated penumbra values (80%-20%) for different field sizes and water depths. Additionally, measured and calculated dose distributions for a head and neck IMRT case using the DELTA{sup 4} phantom have been compared. The validated HD120 MLC implementation has been used for its physical characterization. For this purpose, phase space (PS) files have been generated below the fully closed multileaf collimator (MLC) of a 40 x 22 cm{sup 2} field size for 6 and 15 MV. The PS files have been analyzed in terms of energy spectra, mean energy, fluence, and energy fluence in the direction perpendicular to the MLC leaves and have been compared with the corresponding data using the well established Varian 80 leaf (MLC80) and Millennium M120 (M120 MLC) MLCs. Additionally, the impact of the tongue and groove design of the MLCs on dose has been characterized. Results: Calculated transmission values for the HD120 MLC are 1.25% and 1.34% in the central part of the field for the 6 and 15 MV beam, respectively. The corresponding ionization chamber measurements result in a transmission of 1.20% and 1.35%. Good agreement has been found for the comparison between transmission profiles resulting from MC simulations and film measurements. The simulated and measured values for the penumbra agreed within <0.5 mm for all field sizes, depths, and beam energies, and a good agreement has been found between the measured and the calculated dose distributions for the IMRT case. The total energy spectra are almost identical for the three MLCs. However, the mean energy, fluence and energy fluence are significantly different. Due to the different leaf widths of the MLCs, the shape of these distributions is different, each representing its leave structure. Due to the increase in width from the inner to the outer HD120 MLC leaves, the fluence and energy fluence clearly decrease below the outer leaves. The MLC80 and the M120 MLC resulted in an increase of the fluence and energy fluence compared with those resulted for the HD120 MLC. The dose reduction can exceed 20% compared with the dose of the open field due to the tongue and groove design of the HD120 MLC. Conclusions: The HD120 MLC has been successfully implemented into the SMCP. Comparisons between MC calculations and measurements show very good agreement. The SMCP is now able to calculate accurate dose distributions for treatment plans using the HD120 MLC.

61 RADIATION PROTECTION AND DOSIMETRY↗