Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Simple, Secure, Internet Delivery of MOOSE-based Applications

Application packaging and distribution are the final steps for delivering software to end-users; both are frequently neglected when creating scientific software. Commercial businesses rely on electronic distribution systems that have rendered disk drives obsolete. Still, national laboratories continue to rely heavily on removable media to distribute and limit access to controlled applications. With increasing concerns of unauthorized copying of sensitive applications, a modern distribution system that utilizes cryptographically secure communication and authentication protocols has been developed. This new distribution system will secure the chain of custody for nuclear software while simultaneously simplifying access to these tools. This report summarizes four primary advancements made toward the secure distribution of Nuclear Energy Advanced Modeling and Simulation (NEAMS)-developed, Multiphysics Object Oriented Simulation Environment (MOOSE)-based applications: application installation, package distribution, automated package building, and distribution of documentation. NEAMS is currently developing more than ten separate applications based on the open-source MOOSE Framework. Distribution of these applications has primarily been accomplished by distributing source code, with end-users compiling the applications themselves. This work created a mechanism where MOOSE applications can be installed in a similar way to any other software. This allows both administrators and end-users simplified access to runnable executables. With this new installation capability, it was then possible to rethink distribution. A new, secure capability for delivering MOOSE-based applications over the internet has been created. This system requires unique cryptographic tokens for authentication, greatly securing the custody chain for software. Once granted access, installation of any NEAMS code can be accomplished with these terminal commands: "conda install ncrc" "ncrc install ncrc-bison." After these two commands (and authenticating) the BISON application will be securely down- loaded from Idaho National Laboratory (INL)’s servers, installed, and ready to use. To enable this new distribution capability to be successful, the open-source Continuous Integration, Verification, Enhancement, and Testing (CIVET) Continuous Integration (CI) capability was augmented to add Continuous Delivery (CD). CD enables the automated building and packaging of MOOSE-based applications as they are modified by development teams, ensuring that our customers can obtain up-to-date versions of the software at any time. The need for instruction on how to use these applications was addressed through modifications to the MOOSE documentation system. The MooseDocs capability, which enables robust documentation of MOOSE-based applications, has been extended to allow both for the installation of documentation and the packaging of documentation with installed applications. Together, these enhancements form the core of a new, secure distribution mechanism for nuclear simulation tools. In concert with the Nuclear Computational Resource Center (NCRC), NEAMS- developed applications will now be straightforward to obtain securely.

97 MATHEMATICS AND COMPUTING↗

Assessment of grid-friendly collective optimization framework for distributed energy resources

Distributed energy resources have the potential to provide services to facilities and buildings at lower cost and environmental impact in comparison to traditional electric-gridonly services. The reduced cost could result from a combination of higher system efficiency and exploitation of electricity tariff structures. Traditionally, electricity tariffs are designed to encourage the use of ‘off peak’ power and discourage the use of ‘onpeak’ power, although recent developments in renewable energy resources and distributed generation systems (such as their increasing levels of penetration and their increased controllability) are resulting in pressures to adopt tariffs of increasing complexity. Independently of the tariff structure, more or less sophisticated methods exist that allow distributed energy resources to take advantage of such tariffs, ranging from simple pre-planned schedules to Software-as-a-Service schedule optimization tools. However, as the penetration of distributed energy resources increases, there is an increasing chance of a ‘tragedy of the commons’ mechanism taking place, where taking advantage of tariffs for local benefit can ultimately result in degradation of service and higher energy costs for all. In this work, we use a scheduling optimization tool, in combination with a power distribution system simulator, to investigate techniques that could mitigate the deleterious effect of ‘selfish’ optimization, so that the high-penetration use of distributed energy resources to reduce operating costs remains advantageous while the quality of service and overall energy cost to the community is not affected.

Pensini, Alessandro↗

Agent-Based Distributed Energy Resources for Supporting Intelligence at the Grid Edge

This article proposes a novel multi-agent framework that can link various forms of resources and power electronic systems into distributed energy resources (DER). The proposed multiagent architecture can also integrate DERs to a central controller for optimization and control to support the grid. To demonstrate the flexibility of this novel framework, the developed agent system is applied to a set of end-use systems. Furthermore, the agent framework is validated in hardware using controller-hardware-in-the-loop simulation platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of contamination of municipal water distribution systems

A system for the detection of contaminates of a fluid in a conduit. The conduit is part of a fluid distribution system. A chemical or biological sensor array is connected to the conduit. The sensor array produces an acoustic signal burst in the fluid upon detection of contaminates in the fluid. A supervisory control system connected to the fluid and operatively connected to the fluid distribution system signals the fluid distribution system upon detection of contaminates in the fluid.

47 OTHER INSTRUMENTATION↗

Power peaking with small modular reactors to support deep penetration of renewable energy sources - 192

As inherently intermittent sources of renewable energy more fully penetrate the US grid, peaking power is largely being supplied by carbon-emitting natural gas turbines. Significant greenhouse gas emissions can be avoided if these plants are replaced with carbon-neutral nuclear facilities to provide peaking power to complement renewable generation and meet overall power demand. There is a great deal of previous work regarding reactor power shaping with control rod movement for both currently operating nuclear power plants and proposed plants, but the literature on load-following to meet less predictable, more rapidly varying power demand is less comprehensive. We have chosen the Westinghouse IRIS integral PWR as our candidate for modeling, simulation, and control studies. A nodal model of the IRIS integral PWR, partially adapted from a MATLAB/Simulink model constructed by prior students at the University of Tennessee in Knoxville, has been constructed in Modelica. Currently the model includes the reactor vessel and steam generator system and simple assumptions for the balance of plant. The control scheme for the load-following operation of an IRIS integral PWR model would ultimately lead to the development of real operational mechanisms and principles in a grid with significant renewables capacity. In the future the model will be integrated with sophisticated grid and hybrid energy systems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technologies to Increase PV Hosting Capacity in Distribution Feeders

This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

14 SOLAR ENERGY↗

Versioned distributed arrays for resilience in scientific applications: Global view resilience

Exascale studies project reliability challenges for future high-performance computing (HPC) systems. We propose the Global View Resilience (GVR) system, a library that enables applications to add resilience in a portable, application-controlled fashion using versioned distributed arrays. We describe GVR’s interfaces to distributed arrays, versioning, and cross-layer error recovery. Using several large applications (OpenMC, the preconditioned conjugate gradient solver PCG, ddcMD, and Chombo), we evaluate the programmer effort to add resilience. The required changes are small (<2% LOC), localized, and machine-independent, requiring no software architecture changes. We also measure the overhead of adding GVR versioning and show that generally overheads <2% are achieved. We conclude that GVR’s interfaces and implementation are flexible and portable and create a gentle-slope path to tolerate growing error rates in future systems.

97 MATHEMATICS AND COMPUTING↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Evaluation of Communication Issues in Primal-Dual-Based Distributed Energy Resource Management Systems (DERMS): Preprint

With the increasing adoption of distributed energy resources (DERs) in distribution networks, DERMS is becoming an attractive option to coordinate the control of DERs, especially primal-dual-based DERMS which is a well-developed class of them. In order to help lower the uncertainty in commercializing them, we evaluate and find the upper limits of severity for some common issues that can occur within the communication systems on which a primal-dual-based DERMS relies on; these include packet losses, link failures, and delays. This information can help a DERMS operator decide on the specifications for the communication infrastructure it will invest in for the DERMS. Our evaluation is based on numerical simulations of a real-world feeder with around 2,000 nodes and a DERMS that controls 163 PV generators and 140 energy storage batteries. In general, we found that the DERMS becomes less resistant to communication issues as the information flows closer to the DERs implementing the controllable power injections.

communication delay↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful sel ection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful selection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation Aspects of Smart Grids Cyber-Security Cross-Layered Framework for Critical Infrastructure Operation

Communication networks in power systems are a major part of the smart grid paradigm. It enables and facilitates the automation of power grid operation as well as self-healing in contingencies. Such dependencies on communication networks, though, create a roam for cyber-threats. An adversary can launch an attack on the communication network, which in turn reflects on power grid operation. Attacks could be in the form of false data injection into system measurements, flooding the communication channels with unnecessary data, or intercepting messages. Using machine learning-based processing on data gathered from communication networks and the power grid is a promising solution for detecting cyber threats. In this paper, a co-simulation of cyber-security for cross-layer strategy is presented. The advantage of such a framework is the augmentation of valuable data that enhances the detection as well as identification of anomalies in the operation of the power grid. The framework is implemented on the IEEE 118-bus system. The system is constructed in Mininet to simulate a communication network and obtain data for analysis. A distributed three controller software-defined networking (SDN) framework is proposed that utilizes the Open Network Operating System (ONOS) cluster. According to the findings of our suggested architecture, it outperforms a single SDN controller framework by a factor of more than ten times the throughput. This provides for a higher flow of data throughout the network while decreasing congestion caused by a single controller’s processing restrictions. Furthermore, our CECD-AS approach outperforms state-of-the-art physics and machine learning-based techniques in terms of attack classification. The performance of the framework is investigated under various types of communication attacks.

cross-layered↗

Numerical and experimental investigation of DNAPL removal mechanisms in a layered porous medium by means of soil vapor extraction

The purpose of this work is to identify the mechanisms that govern the removal of carbon tetrachloride (CT) during soil vapor extraction (SVE) by comparing multiphase flow simulations with a detailed data set from a well-defined two-dimensional flow cell experiment. The flow cell was packed with two sandy soils including an embedded fine-grained sand layer. Gas concentrations at the outlet of the flow cell and 15 sampling ports inside the flow cell were measured during SVE. A dual-energy gamma radiation system was used to measure an initial NAPL saturation profile in a fine-grained sand layer. Imaging result from a dual-energy gamma radiation system with dyed CT mark along CT migration was used to construct the distribution of initial NAPL saturation in the flow cell for input to numerical simulations. Gas concentration results and photographs during SVE were compared to simulation results using a continuum-based multiphase flow simulator, STOMP (Subsurface Transport Over Multiple Phases). The measured effluent gas concentration decreased quickly at first, and then started to decrease gradually, resulting in long-term tailing. CT mass was removed quickly in coarse sand, followed by a slow removal from the fine-grained sand layer. An analytical solution for a one-dimensional advection and first-order volatilization model matched the tailing well with two fitting parameters. However, given detailed knowledge of the permeability field and initial NAPL distribution, we can predict the tailing and gas concentration profiles at sampling ports using equilibrium NAPL volatilization. NAPL flow occurs in the presence of free NAPL, and must be accounted for to accurately predict NAPL removal during the SVE experiment. The model prediction was accurate within the uncertainty of the measured or literature derived parameters (i.e., dispersivity and soil parameters). This study provides insights into the physical mechanisms of NAPL removal from a low permeability zone, and use of the local equilibrium assumption for NAPL volatilization during SVE. In addition, this study demonstrates that lack of detailed information regarding NAPL distribution and heterogeneity pattern lead overall NAPL removal to a kinetically controlled system at a 2-D flow cell scale.

54 ENVIRONMENTAL SCIENCES↗

An Optimized Input/Output-Constrained Control Design With Application to Microgrid Operation

In this paper, a nonlinear control design is presented for systems whose input and output vectors are saturated. The proposed synthesis includes an optimal tracker as the seed controller and explicitly imposes all the relevant constraints on system input, on the rate of change in the input, and on system output by using the tools of barrier functions, input-output feedback linearization, comparison argument, Lyapunov argument, and a real-time constrained optimization. The proposed design is applied to microgrid operation with high penetration of renewable generation, where net load and variable generation must be balanced and the microgrid should be operated at an optimal or near-optimal performance level. Since traditional generation has a limited ramping rate, battery storage devices and demand responses become necessary to effectively deal with variability of renewable generation and to maintain frequency stability, but their capacities are also limited. Finally,it is shown that the proposed design is effective for coordinated control of traditional generation, storage and demand response so that the power system frequency is guaranteed to be within the required operational limits and that renewable curtailment is eliminated or minimized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Secure and Safe Operation of Solar Photovoltaic Power Distribution Systems

Solar photovoltaic (PV)-rich power distribution systems are networked Cyber-Physical Systems (CPS). These are control systems where multiple computing nodes and diverse intelligent agents interact with the physical world in real-time. However, the presence of networked components renders them vulnerable to potential cyber-attacks, cyber-intrusions, and other malicious events. This is because these systems depend on the measurements reported from their heterogeneous sensors. This makes them vulnerable to potential cyber-attacks where malicious agents can compromise the sensors or the communication networks carrying the sensor measurements. This paper proposes a novel methodology for enhancing the cyber-security and cyber-resilient post-attack safe operation of solar PV-rich power distribution systems against potential cyber-attacks through the Dynamic Watermarking (DW), using online system identification. The resiliency of the proposed technique is tested and validated with several attack scenarios on both a lab-scale 3kW grid-connected PV inverter and a Hardware-in-the-Loop (HiL) system. The proposed approach can be applied to other types of power distribution systems to enhance their cyber-secure and cyber-resilient safe operation. This paper thereby contributes to the field of cyber-security of Cyber-Physical Energy Systems (CPES).

Kim, Jaewon↗

Leader–follower fixed-time consensus of multi-agent systems with high-order integrator dynamics

The leader-follower fixed-time consensus of high-order multi-agent systems with external disturbances is investigated in this paper. A novel sliding manifold is designed to ensure that the tracking errors converge to zero in a fixed-time during the sliding motion. Then, a distributed control law is designed based on Lyapunov technique to drive the system states to the sliding manifold in finite-time independent of initial conditions. Finally, the efficiency of the proposed method is illustrated by numerical simulations.

42 ENGINEERING↗