Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical system integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Towards a Circular Economy for PET Bottles in the U.S. - 4P Model

The United States generates the most plastic waste of any country. Along with that GHG emissions from the global plastic economy are expected to increase to 15% of the global carbon budget by 2050. It is imperative that plastic recycling is made a reality to reduce both plastic pollution in the environment and GHG emissions. A portfolio of end-of-life strategies must be implemented to minimize environmental impacts and retain valuable plastic material, but it is challenging to compare options that generate products with different utility and lifetime. Plastic use reduction, reuse and recycling are thus increasingly important, but making informed policy and research decisions within this space can be challenging given the diverse range of available solutions. The novel analysis framework, Plastic Parallel Pathways Platform (4P) has been equipped with consequential life cycle assessment, techno-economic analysis, and a plastic circularity indicator to estimate the greenhouse gas (GHG) emissions, circularity, and cost of polyethylene terephthalate (PET) down-cycling to lower-quality resin, closed-loop recycling to food-grade PET bottles, up-cycling to fiber-reinforced plastic (FRP), and conversion to non-plastic products (electricity, oil) on a United States economy-wide basis. Integrating system dynamics into this robust plastics model that already incorporates techno-economics, circularity, and environmental impacts will enable identification of key bottlenecks between manufacturers, waste sorters, and reclaimers that currently prevent rapid decarbonization of the plastics economy. System dynamics (SD) explore the evolution of activities and technologies based on changed macro parameters such as plastic demand and supply, market shifts, and cross-sectoral interactions. This project particularly aims to explore the interplay between, waste collection, plastic waste sorting, recycling, and manufacturing, as well as the effect of plastic bale quality and plastic reuse initiatives on the surrounding process stages. This functionality will facilitate combinatory analysis in which a portfolio of end-of-life pathways are assessed simultaneously, with the exact makeup of that portfolio affected by parameters such as technology scales, resource constraints, and waste mitigation efforts. Integrating SD with the 4P framework enables analyzing the effect of increased revenue and reinvestment into improving process efficiencies, sorting and collection quantities. Through that, market effects of increased recycled resin availability can be studied for the plastics systems model for the US. The results will help identify technical or economic bottlenecks that currently limit efforts to decarbonize the U.S. plastics economy.

carbon↗

Towards a Circular Economy for PET Bottles in the U.S. - 4P Framework

The United States generates the most plastic waste of any country. Along with that GHG emissions from the global plastic economy are expected to increase to 15% of the global carbon budget by 2050. It is imperative that plastic recycling is made a reality to reduce both plastic pollution in the environment and GHG emissions. A portfolio of end-of-life strategies must be implemented to minimize environmental impacts and retain valuable plastic material, but it is challenging to compare options that generate products with different utility and lifetime. Plastic use reduction, reuse and recycling are thus increasingly important, but making informed policy and research decisions within this space can be challenging given the diverse range of available solutions. The novel analysis framework, Plastic Parallel Pathways Platform (4P) has been equipped with consequential life cycle assessment, techno-economic analysis, and a plastic circularity indicator to estimate the greenhouse gas (GHG) emissions, circularity, and cost of polyethylene terephthalate (PET) down-cycling to lower-quality resin, closed-loop recycling to food-grade PET bottles, up-cycling to fiber-reinforced plastic (FRP), and conversion to non-plastic products (electricity, oil) on a United States economy-wide basis. Integrating system dynamics into this robust plastics model that already incorporates techno-economics, circularity, and environmental impacts will enable identification of key bottlenecks between manufacturers, waste sorters, and reclaimers that currently prevent rapid decarbonization of the plastics economy. System dynamics (SD) explore the evolution of activities and technologies based on changed macro parameters such as plastic demand and supply, market shifts, and cross-sectoral interactions. This project particularly aims to explore the interplay between, waste collection, plastic waste sorting, recycling, and manufacturing, as well as the effect of plastic bale quality and plastic reuse initiatives on the surrounding process stages. This functionality will facilitate combinatory analysis in which a portfolio of end-of-life pathways are assessed simultaneously, with the exact makeup of that portfolio affected by parameters such as technology scales, resource constraints, and waste mitigation efforts. Integrating SD with the 4P framework enables analyzing the effect of increased revenue and reinvestment into improving process efficiencies, sorting and collection quantities. Through that, market effects of increased recycled resin availability can be studied for the plastics systems model for the US. The results will help identify technical or economic bottlenecks that currently limit efforts to decarbonize the U.S. plastics economy.

circular economy↗

Cayuga County Regional Digester: Vision Becomes Reality. Final Report

With an average herd size of 113 mature cows, Cayuga County is home to 280 dairy farms and 31,500 dairy milking cows producing approximately 855 million gallons of milk per year. The Cayuga Dairy industry is a major contributor to the countys economy, employing nearly 1200 people, while generating $140,000,000 of revenue from sale of milk alone. At the same time, the Cayuga County dairy industry also produces 5.7 million gallons of manure daily: (a) Nearly 34% of this manure is produced on smaller farms. (b) Digesters are expensive pieces of equipment and require attention and care. ( c) The on-farm digester systems have fairly long payback (>10 years) even for larger CAFO farms (>1000 milking cows). In 2005, Cayuga County Soil and Water Conservation District (The District), a Public Agency under Cayuga County, decided to undertake a centralized community digester project. The primary goal of the project was to develop an economically sustainable model, under the auspices of The District to address manure management issues facing the smaller dairies, improve the water quality and improve the quality of life for Cayuga County residents. It is believed that the District has accomplished this goal by completing construction of Cayuga County Regional Digester on a parcel of land behind the Cayuga County Natural Resource Center located at 7413 County House Road in the Town of Sennett in Cayuga County, New York. The digester facility consists of the following major components. 1. Transfer Station: This an indoor truck bay, where 35,000 gallons of manure from three local farms, 8,500 gallons of liquid organic food-processor waste, and 1,200 gallons of brown grease are unloaded from tanker trucks and the digested slurry is loaded onto the tanker trucks for delivery back to the participating farms. 2. Anaerobic Digester: The project utilizes a hydraulic mix anaerobic digester, a unique design that has no internal moving parts for mixing. The digester, which operates at mesophilic temperatures, is designed to process the daily feedstock and produce 220,000 SCF2 of biogas per day. The digester also produces 44,000 gallons of digested slurry per day. 3. Biogas Conditioning System: The plant employs a biological biogas conditioning system to remove the H2S and moisture contents of the biogas and prepare it to be used by the plant generation system. 4. Combined Heat and Power System (CHP): This is a 633kW high efficiency biogas-fired GE-Jenbacher model JMS-312 GS-NL reciprocating engine cogeneration system. The heat recovery system incorporated into the package is designed to capture the waste heat from the engine exhaust, the jacket cooling water and the engine oil circuit. 5. Electrical Substation and Power Distribution Systems: An electrical distribution system has been constructed on-site that aggregates the electrical service of the different county buildings on the District campus into a county owned electric distribution system that is interconnected with the CHP and the local electric grid. The electrical system is designed, in accordance with the utility guidelines, to allow grid-parallel operation of CHP and provide for import and export of electric power. 6. Thermal Energy Distribution System: The heat recovery system has been integrated into a high temperature water distribution system that distributes the heat to the thermal circuits for the anaerobic digester facility. Additional piping has also been installed to transfer the remaining thermal energy to other county buildings on the campus. On a daily basis, the plant will co-process 35,000 gallons of manure from local dairy farms, 8,500 gallons of food-processor waste and 1,200 gallons of brown grease to produce 200,000 ft3/d of biogas and 44,000 gallons of pathogen-free nutrient-rich digested slurry for agricultural use by farms and in the local area.The biogas fueled CHP produces 5,157,000 kWh of electricity and 19,506 dekatherms of thermal energy per year. Electrical power generated by the cogeneration system powers all the buildings on the Cayuga County campus and any surplus power is exported to the grid under a power purchase agreement. Heat recovered from the cogeneration system will be used to maintain the temperature of the process equipment and the excess will be transported to the Cayuga County Public Safety Building to offset purchase of fossil fuel to fuel the boilers. The majority of plant operations are unmanned and automated. However, the plant will have a small staff of well-trained personnel to coordinate the feedstock deliveries and shipments, supervise the day-to-day operation, monitor the systems and perform maintenance, maintain a safe and reliable operation and to respond to emergencies.

09 BIOMASS FUELS↗

High-Temperature Passive Power Electronics

In many future NASA missions - such as deep-space exploration, the National AeroSpace Plane, minisatellites, integrated engine electronics, and ion or arcjet thrusters - high-power electrical components and systems must operate reliably and efficiently in high-temperature environments. The high-temperature power electronics program at the NASA Lewis Research Center focuses on dielectric and insulating material research, the development and characterization of high-temperature components, and the integration of the developed components into a demonstrable 200 C power system - such as an inverter. NASA Lewis has developed high-temperature power components through collaborative efforts with the Air Force Wright Laboratory, Northrop Grumman, and the University of Wisconsin. Ceramic and film capacitors, molypermalloy powder inductors, and a coaxially wound transformer were designed, developed, and evaluated for high-temperature operation.

Source record↗

Advanced Communication and Control for Distributed Energy Resource Integration: Phase 2 Scientific Report

The objective of this research project is to demonstrate sensing, communication, information and control technologies to achieve a seamless integration of multivendor distributed energy resource (DER) units at aggregation levels that meet individual user requirements for facility operations (residential, commercial, industrial, manufacturing, etc.) and further serve as resource options for electric and natural gas utilities. The fully demonstrated DER aggregation system with embodiment of communication and control technologies will lead to real-time, interactive, customer-managed service networks to achieve greater customer value. Work on this Advanced Communication and Control Project (ACCP) consists of a two-phase approach for an integrated demonstration of communication and control technologies to achieve a seamless integration of DER units to reach progressive levels of aggregated power output. Phase I involved design and proof-of-design, and Phase II involves real-world demonstration of the Phase I design architecture. The scope of work for Phase II of this ACCP involves demonstrating the Phase I design architecture in large scale real-world settings while integrating with the operations of one or more electricity supplier feeder lines. The communication and control architectures for integrated demonstration shall encompass combinations of software and hardware components, including: sensors, data acquisition and communication systems, remote monitoring systems, metering (interval revenue, real-time), local and wide area networks, Web-based systems, smart controls, energy management/information systems with control and automation of building energy loads, and demand-response management with integration of real-time market pricing. For Phase II, BPL Global shall demonstrate the Phase I design for integrating and controlling the operation of more than 10 DER units, dispersed at various locations in one or more Independent System Operator (ISO) Control Areas, at an aggregated scale of more than 1 MW, to provide grid support. Actual performance data with respect to each specified function above is to be collected during the Phase II field demonstration. At a minimum, the Phase II demonstration shall span one year of field operations. The demonstration performance will need to be validated by the target customer(s) for acceptance and subsequent implementation. An ISO must be involved in demonstration planning and execution. As part of the Phase II work, BPL Global shall develop a roadmap to commercialization that identifies and quantifies the potential markets for the integrated, aggregated DER systems and for the communication and control technologies demonstrated in Phase I. In addition, the roadmap must identify strategies and actions, as well as the regional and national markets where the aggregated DER systems with communication and control solutions will be introduced, along with a timeline projected for introduction into each identified market. In Phase I of this project, we developed a proof-of-concept ACCP system and architecture and began to test its functionality at real-world sites. These sites had just over 10 MW of DERs and allowed us to identify what needed to be done to commercialize this concept. As a result, we started Phase II by looking at our existing platform and identified its strengths and weaknesses as well as how it would need to evolve for commercialization. During this process, we worked with different stakeholders in the market including: Independent System Operators, DER owners and operators, and electric utility companies to fully understand the issues from all of the different perspectives. Once we had an understanding of the commercialized ACCP system, we began to document and prepare detailed designs of the different system components. The components of the system with the most significant design improvements were: the on-site remote terminal unit, the communication technology between the remote site and the data center, and the scalability and reliability of the data center application. As we began to implement the Phase II ACCP system, we upgraded the real-world demonstration sites from Phase I of the project as well as added additional sites to broaden the types of DER the platform was tested with. We worked with the owners and operators of these sites to understand how the system was meeting their needs and made modifications throughout the project as needed. This also included an effort to continue to understand the barriers to commercial adoption of the ACCP architecture and standardized communication protocols. The final aspect of this phase of the project was to prepare resources to aid in the commercial adoption of the ACCP architecture and standardized communication protocols. This entailed: presentations at conferences, published articles and papers, and web-based technical resources to provide tools to aid in the design and implementation of ACCP systems.

03 NATURAL GAS↗

Grid Planning Impacts of Hydropower Growth and Decline

Hydropower and pumped storage hydropower (PSH) have a complex and uncertain future in the U.S. electricity system. On one hand, existing assets have the potential for an expanded role in integrating variable renewable energy while new deployment, particularly of PSH, can help meet growing needs for grid flexibility and improved reliability. On the other hand, challenging environmental and cost considerations could limit the extent of new investments in hydropower and PSH capacity and flexibility. This technical presentation demonstrates the use of a high-fidelity capacity expansion model of the U.S. electric grid (the National Renewable Energy Laboratory's Regional Energy Deployment System) to understand the impacts of alternative futures for the hydropower and PSH fleet, including scenarios of both growth and decline. Growth scenarios include new PSH deployment or improved hydropower flexibility, while scenarios of decline reduce the capacity or energy production potential of hydropower and PSH. Economic, environmental, and performance outcomes of the grid are compared across these scenarios to reveal the potential contributions of hydropower and PSH in the U.S. electric sector over the next several decades, focusing on changes to the grid technology mix, electric sector costs, electricity prices, and air emissions. This broad scenario approach demonstrates how flexible hydropower and PSH can help reduce air emissions and cost by complementing variable renewables, but the opposite can occur with reduced hydropower availability, particularly in the next decade. It is important to consider a wide range of scenarios and metrics to gain a national and regional understanding of hydropower's future in the United States.

capacity expansion↗

A view to the future of natural gas and electricity: An integrated modeling approach

This paper demonstrates the value of integrating two highly spatially resolved models: the Rice World Gas Trade Model (RWGTM) of the natural gas sector and the Regional Energy Deployment System (ReEDS) model of the U.S. electricity sector. The RWGTM passes electricity-sector natural gas prices to the ReEDS model, while the ReEDS model returns electricity-sector natural gas demand to the RWGTM. The two models successfully converge to a solution under reference scenario conditions. We present electricity-sector and natural gas sector evolution using the integrated models for this reference scenario. This paper demonstrates that the integrated models produced similar national-level results as when running in a stand-alone form, but that regional and state-level results can vary considerably. As we highlight, these regional differences have potentially significant implications for electric sector planners especially in the wake of substantive policy changes for the sector (e.g., the Clean Power Plan).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing Construction through the Buildings Workforce: Preprint

Buildings are America's energy hogs, consuming over 70 percent of all electricity and over 50 percent of all natural gas produced across the country. Achieving a clean energy future requires us to reinvent how buildings manage energy resources and how consumers demand it. The U.S. Department of Energy is investing in a range of technological advancements that are paving the way to a future where buildings are no longer simply energy consumers, but rather are part of an integrated system that help manage energy resources in a way that supports the electricity grid. This paradigm shift presents an opportunity to increase the efficiency of the built environment, but will only be realized if we build a knowledgeable workforce to design, construct, and operate these high-performance buildings in step with the rate of technological advancement.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Solar Thermoelectricity via Advanced Latent Heat Storage

We report on a new modular, dispatchable, and cost-effective solar electricity-generating technology. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) integrates several state-of-the-art technologies to provide electricity on demand. In the envisioned STEALS system, concentrated sunlight is converted to heat at a solar absorber. The heat is then delivered to either a thermoelectric (TE) module for direct electricity generation, or to charge a phase change material for thermal energy storage, enabling subsequent generation during off-sun hours, or both for simultaneous electricity production and energy storage. The key to making STEALS a dispatchable technology lies in the development of a 'thermal valve,' which controls when heat is allowed to flow through the TE module, thus controlling when electricity is generated. The current project addresses each of the three major subcomponents, (i) the TE module, (ii) the thermal energy storage system, and (iii) the thermal valve. The project also includes system-level and techno- economic modeling of the envisioned integrated system and will culminate in the demonstration of a laboratory-scale STEALS prototype capable of generating 3kWe.

14 SOLAR ENERGY↗

The Energy Systems Optimization Computer Program /ESOP/ developed for Modular Integrated Utility Systems /MIUS/ analysis

A significant energy and cost savings can be obtained by integrating various utility services (space heating and cooling, electrical power generation, solid waste disposal, potable water, and waste water treatment) into a single unit which provides buildings or groups of buildings with these services. This paper presents a description of a computer program, called the Energy Systems Optimization Program (ESOP). This program predicts the loads, energy requirements, equipment sizes, and life-cycle costs of alternative methods of meeting these utility requirements. The program has been used extensively for performing energy analyses of Modular Integrated Utility Systems (MIUS).

Ferden, S. L.↗

Optimal Operation and Impact Assessment of Distributed Wind for Improving Efficiency and Resilience of Rural Electricity Systems

This project aims to empower rural utilities by developing advanced optimization models and algorithms for effectively integrating distributed wind energy alongside battery storage and other distributed energy resources (DERs). The primary objectives are to reduce peak demand, ensure reliable emergency power supply, and regulate voltage and frequency. To address operational challenges, the project introduces innovative mitigation strategies and ultrafast assessment frameworks to evaluate the impacts of distributed wind and DERs on rural grids, offering actionable solutions to potential issues. Economic viability is assessed through cost-benefit analysis using real rural utility data, ensuring the practical application of the project outcomes.

17 WIND ENERGY↗

Evaluation of an Integrated Gas-Cooled Reactor Simulator and Brayton Turbine-Generator

A closed-loop brayton cycle, powered by a fission reactor, offers an attractive option for generating both planetary and in-space electric power. Non-nuclear testing of this type of system provides the opportunity to safely work out integration and system control challenges for a modest investment. Recognizing this potential, a team at Marshall Space Flight Center has evaluated the viability of integrating and testing an existing gas-cooled reactor simulator and a modified commercially available, off-the-shelf, brayton turbine-generator. Since these two systems were developed independently of one another, this evaluation had to determine if they could operate together at acceptable power levels, temperatures, and pressures. Thermal, fluid, and structural analyses show that this combined system can operate at acceptable power levels and temperatures. In addition, pressure drops across the reactor simulator, although higher than desired, are also viewed as acceptable. Three potential working fluids for the system were evaluated: N2, He/Ar, and He/Xe. Other potential issues, such as electrical breakdown in the generator and the operation of the brayton foil bearings using various gas mixtures, were also investigated.

Hissam, David Andy↗

Techno-Economic Optimization of CSP Plants with Free-Falling Particle Receivers

Particle receivers are one of the candidates for the next generation of CSP plants, whose goal is to reduce the levelized cost of electricity (LCOE) to 0.05 $/kWh. This paper presents a techno-economic analysis to study if a CSP system with free-falling particle receiver can achieve this goal. The plant analyzed integrates two ground-based bins to store the excess energy and a supercritical CO2 cycle to generate electricity. The model used for the analysis presents several upgrades to previous particle systems models in order to increase its fidelity, accuracy, and representativeness of an actual system. The main upgrades are the addition of off-design conditions during the annual simulations in all the components and an improved receiver model validated against CFD simulations. The size of the main components is optimized to obtain the system configuration with minimum LCOE. The results show that particle CSP systems can reduce the LCOE to 0.056 $/kWh if the configuration is composed of 1.61 × 106 m2 of heliostats, a 250 m high tower with a 537 m2 falling particle curtain, and 16 h thermal energy storage.

54 ENVIRONMENTAL SCIENCES↗

Design of energy storage system to improve inertial response for large scale PV generation

With high-penetration levels of renewable generating sources being integrated into the existing electric power grid, conventional generators are being replaced and grid inertial response is deteriorating. This technical challenge is more severe with photovoltaic (PV) generation than with wind generation because PV generation systems cannot provide inertial response unless special countermeasures are adopted. To enhance the inertial response, this paper proposes to use battery energy storage systems (BESS) as the remediation approach to accommodate the degrading inertial response when high penetrations of PV generation are integrated into the existing power grid. A sample power system was adopted and simulated using PSS/E software. Here, impacts of different penetration levels of PV generation on the system inertial response were investigated and then BESS was incorporated to improve the frequency dynamics.

25 ENERGY STORAGE↗

Leveraging National Laboratory Assets to Address Stability Challenges due to Declining Grid Inertia Using Geographically Distributed Electrical–Thermal Co-Emulation

Due to increased penetration of low-inertia resources into the electric grid, challenges are increasing for maintaining wide-area system stability. Grid stability assessment requires a faithful representation of the multiple-physics interaction at the system level, and timescales of interaction varying in orders of magnitude, from microseconds to seconds to several minutes. Along with the simulation-based techniques, hardware-in-the-loop (HIL), controller HIL, and power HIL techniques have been developed to better understand the emergent behavior of the system with emerging technologies. US National Laboratories have played a vital role in research and development to understand the behavior of individual technologies and devices integrated to the electric grid. Each national laboratory forwards a technological and strategic initiative tied core and enabling capabilities. Due to strategic, efficiency, and economic reasons, not all the labs have assets to conduct research on all technologies concomitantly, so it becomes crucial to integrate the labs across geographies to understand the interplay of different technologies together at the system level. This approach avoids duplication of the assets at different lab facilities and helps understand the integrated system behavior of various technologies representative of actual grid conditions by connecting multiple national labs. This article talks about techniques of connecting three national laboratories to enable co-emulation of electrical–mechanical–thermal characteristics of devices and systems. Such an approach can be used to understand the dynamic and transient interaction of multi-physics in a system level, at-scale emulation using real-time simulation tools and techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probabilistic Look-ahead Contingency Analysis Integration with Commercial Tool and Practical Data

This paper presents an initial effort of integrating a smart sampling-based probabilistic look-ahead contingency analysis algorithm with General Electric (GE) Grid Solutions’ commercial energy management system (EMS) tool as a proof-of-concept for a seamless research tool integration using real world large-scale grid data. With the increasing impact of random forces such as variable generation and load, their stochastic behaviors cannot be ignored. However, the current practices are still dominated by deterministic tools. They are becoming increasingly inadequate for the future grid. The developed look-ahead contingency analysis algorithm incorporates forecast errors of variable energy and load to address the challenges brought by the increasing uncertainty of power system. The algorithm can reveal the potential violations caused by the variance of variable energy and load that are not normally detected by traditional deterministic approaches. To test its performance under practical environments ( real data with real commercial tool), significant efforts have been made to prepare test cases, modify GE EMS tool, and adapt an extreme value distribution algorithm to analyze the GE EMS’s violation-only outputs. The test results clearly demonstrate the effectiveness of the developed algorithm as new transformer violations that were not previously detected have been identified. This performance provides better situational awareness to engineers for their decision-making process under uncertainty. Moreover, with the discussion of computational performance and future work, this paper has shown a clear path for integrating the probabilistic algorithm with commercial tools to make us better equipped for the changing power system.

Modeling and simulation of power systems, constrai↗

Design Exploration of a Mild Hybrid Electrified Aircraft Propulsion Concept

NASA has performed in-depth research and analysis into hybrid-electric aircraft concepts featuring high levels of electrification. Many of these concepts were found to be infeasible, whereas feasible designs were significantly heavier and more costly compared to conventional concepts. This study presents the development and analysis of an alternative mild hybrid concept that uses relatively low levels of stored electric energy applied strategically throughout the mission. The team researched several mild hybrid technologies, developed integrated aircraft models, and then evaluated the effects of these technologies on vehicle level performance metrics. Technologies explored in this study include the Turbine Electrified Energy Management system, electric taxi, electric climb assist, and replacing the auxiliary power unit with on-board electric energy storage. Key enabling technologies were energy storage devices that prioritized high power output over energy capacity and integrating electric motors with the shafts of the gas turbine engines. Significant performance improvements were observed when applying multiple technologies separately and in combination, with the most promising configuration incorporating all of them at once. Results for the mild hybrid configuration indicate an 8.2% reduction in block fuel, a 7.7% reduction in equivalent CO2 emissions, and a 3.5% increase in gross takeoff weight compared to a conventional baseline. Results of a cost analysis suggest the mild hybrid slightly reduces direct operating cost plus interest, which demonstrates that aircraft emissions can be significantly reduced without the cost increases associated with highly electrified concepts.

Turbine Electrified Energy Managment↗