Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Draft ASME Boiler and Pressure Vessel Code Cases and Technical Bases for Use of Alloy 617 for Constructions of Nuclear Component Under Section III, Division 5

The American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code currently only allows five materials for use in construction of nuclear components for high temperature service. These are: 2.25Cr-1Mo and V-modified 9Cr-1Mo steels, Types 304 and 316 stainless steels and the high nickel Alloy 800H. Since 2005, the US high temperature gas-cooled reactor program has been characterizing elevated temperature mechanical properties of Alloy 617 as the leading candidate construction material for the intermediate heat exchanger. After analysis of these experimental results, along with historical data and additional results available through the Generation IV International Forum, Very High Temperature Reactor, Materials Program Management Board Materials Handbook, a draft ASME Code Case to allow nuclear construction with Alloy 617 for temperatures up to 1750°F (954°C) has been developed. This report contains the Code Case for Low Temperature Service Construction of Section III, Division 5, Subsection HB, Subpart A, Class A and Subsection HC, Subpart A, Class B components, which has been approved in Section II, Materials, and Section III, Rules for Construction of Nuclear Facility Components. Supporting technical justification for the low temperature Code Case is also included. This Code Case allows use of Alloy 617 up to 800°F (425°C). This report also contains an updated draft of a Section III, Division 5, Subsection HB, Subpart B, Class A Code Case for Alloy 617 to qualify it for use in construction of nuclear components up to 1750°F (954°C) for service life up to 100,000 hours. The draft contained in Appendix 4, subject to editorial revision and approval by the ASME Special Task Group on Alloy 617 Code Qualification, will be submitted for approval by letter ballot by the appropriate ASME Committees. The technical justification supporting the Code Case is presented in Appendix 5 of this report. This background document is part of the information package that will be submitted with the Code Case for ballot.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Spectrum Molten Salt-Fueled Reactor Reference Plant Model

This report details a fully coupled neutronics thermal hydraulics reference plant model for a thermal spectrum molten salt-fueled reactor. The Multiphysics model is developed on the Nuclear Regulatory Commission's Comprehensive Reactor Analysis Bundle available on the Idaho National Laboratory high-performance computer, which natively and seamlessly couples Griffin and Sam codes of the Multiphysics Object-Oriented Simulation Environment (MOOSE) based applications. Griffin provides the reactor physics capabilities, k-eigenvalue, delayed neutron precursor concentrations, and transient solutions for stationary and flowing fuels. Sam provides the solution of mass, momentum, and energy conservation equations of the whole system with a set of system components for one-dimensional single-phase flow. The neutronics feedback model relies primarily on fuel and moderator temperatures, fuel salt density, and delayed neutron precursors distributions. This report presents our results for the coupled steady state core and an unprotected loss of flow event. Although this model is prototypical regarding capabilities in the Comprehensive Reactor Analysis Bundle, its results are consistent with experimental data of the pump transient tests that were performed at zero power of the Molten Salt Reactor Experiment (MSRE).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Window observables for benchmarking parton distribution functions

Global analysis of collider and fixed-target experimental data and calculations from lattice quantum chromodynamics (QCD) are used to gain complementary information on the structure of hadrons. We propose novel ``window observables'' that allow for higher precision cross-validation between the different approaches, a critical step for studies that wish to combine the datasets. Global analyses are limited by the kinematic regions accessible to experiment, particularly in a range of Bjorken-x, and lattice QCD calculations also have limitations requiring extrapolations to obtain the parton distributions. We provide two different ``window observables'' that can be defined within a region of x where extrapolations and interpolations in global analyses remain reliable and where lattice QCD results retain sensitivity and precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The nature of flow distortions caused by rotor blade wakes

The distortion caused by wakes of rotor blades is one of the least understood phenomena in turbomachinery. An attempt is made to predict the decay characteristics of the defect in axial and tangential velocity components, and the decay of the maximum radial velocity inside the rotor wake using the momentum integral analysis. The predictions agree well with the experimental data taken at the exit of an axial flow fan operating at zero incidence. The measurements are carried out with a three sensor hot wire probe. The wake width is found to grow linearly with distance downstream and the defect in tangential velocity inside the rotor wake decays fastest of the three components. An empirical expression is also provided for the axial velocity profile of a rotor wake.

Lakshminarayana, B.↗

Spacelab cryogenic propellant management experiment

The conceptual design of a Spacelab cryogen management experiment was performed to demonstrate toe desirability and feasibility of subcritical cryogenic fluid orbital storage and supply. A description of the experimental apparatus, definition of supporting requirements, procedures, data analysis, and a cost estimate are included.

Cady, E. C.↗

Vibration and buckling studies of pretensioned structures

Results of analyses and tests of a simple pretensional structure are presented. Linear finite element analysis correlated well with experimental small amplitude vibration data. The buckling and vibration behavior of a pretensional stayed column was studied in detail. The bifurcation buckling load was also predicted accurately. Postbuckling behavior of the column was unusual and results in a post buckling restoring force of only 1/64 the bifurcation buckling load. Interaction between lateral accelerations and compressive load creates isolated stay slackening at loads above 50 percent of the buckling load. Further research will be required to fully understand their impact on the use of pretensioned structures as large space structures.

Belvin, W. K.↗

Deriving Strain Modes From Vibrational Tests

Measurements and theoretical analysis complement each other. Experimental acceleration and strain data used to calculate coefficients of low-frequency vibrational modes of object under test. An iterative comparison of experimental and calculated strains give modal model of improved accuracy that predicts strains under operating conditions. Method useful in fatigue life and reliability analyses of buildings, pumps, engines, vehicles, and other systems subject to vibrations and loud noises during operation.

Young, J. W.↗

Fluid mass and thermal loading effects on the modal characteristics of space shuttle main engine liquid oxygen inlet splitter vanes

An analysis and evaluation of experimental modal survey test data on the variations of modal characteristics induced by pressure and thermal loading events are presented. Extensive modal survey tests were carried out on a Space Shuttle Main Engine (SSME) test article using liquid nitrogen under cryogenic temperatures and high pressures. The results suggest that an increase of pressure under constant cryogenic temperature or a decrease of temperature under high pressure induces an upward shift of frequencies of various modes of the structures.

Panossian, H. V.↗

Thermodynamic properties and crystallization kinetics at high liquid undercooling

The heat capacities of liquid and crystalline Au-Pb-Sb alloys in the glass-forming composition range were measured with droplet emulsion and bulk samples. Based on the measured C(sub p) data, the entropy, enthalpy, and Gibbs free energy functions of the eutectic, solid mixture, and undercooled liquid were determined as a function of undercooling and compared with theoretical predictions. The results indicate an isentropic temperature at 313 + or - 5 K, which agrees well with experimental data for the glass transition. A kinetics analysis of the nucleation undercooling response suggests that the proper choice for the Gibbs free energy change during crystallization is most important in analyzing the nucleation kinetics. By classical nucleation theory, the prefactors obtained, based on a variety of theoretical predictions for the driving force, can differ by six orders of magnitude. If the nucleation rates are extrapolated to high undercooling, the extrapolations based on measured heat capacity data show agreement, whereas the predicted nucleation rates are inconsistent with results from drop tower experiments. The implications for microg experiments are discussed.

Fecht, Hans J.↗

Boundary layer energization by means of optimized vortex generators

A three-dimensional, multi-block, multi-zone, Euler analysis has been developed and applied to analyze the flow processes induced by a lateral array of low profile vortex generators (VG). These vortex generators have been shown to alleviate boundary layer separation through the generation of streamwise vorticity. The analysis has been applied to help develop improved VG configurations in an efficient manner. Special attention has been paid to determining the accuracy requirements of the solver for calculations in which vortical mechanisms are dominant. The analysis has been used to assess the effectiveness or boundary layer energization capacity of different VG's, including the effect of scale and shape variation. Finally, the analysis has been validated through comparisons with experimental data obtained in a large-scale low-speed wind tunnel.

Barber, T. J.↗

Estimation of random bending strain using a scanning laser vibrometer

Results are presented which were obtained from vibration measurements at discrete locations on a randomly excited structure to estimate the power spectral density of bending strain. The technique is intended to be applied using a scanning laser vibrometer to allow a non-contacting measurement of random bending strain over the surface of a structure. The experimental setup is described along with the data analysis procedure. The results presented here indicate that the method is practical and can lead to reliable estimates.

Miles, R. N.↗

Application of a Navier-Stokes Solver to the Analysis of Multielement Airfoils and Wings Using Multizonal Grid Techniques

A computational study was performed to determine the predictive capability of a Reynolds averaged Navier-Stokes code (CFL3D) for two-dimensional and three-dimensional multielement high-lift systems. Three configurations were analyzed: a three-element airfoil, a wing with a full span flap and a wing with a partial span flap. In order to accurately model these complex geometries, two different multizonal structured grid techniques were employed. For the airfoil and full span wing configurations, a chimera or overset grid technique was used. The results of the airfoil analysis illustrated that although the absolute values of lift were somewhat in error, the code was able to predict reasonably well the variation with Reynolds number and flap position. The full span flap analysis demonstrated good agreement with experimental surface pressure data over the wing and flap. Multiblock patched grids were used to model the partial span flap wing. A modification to an existing patched- grid algorithm was required to analyze the configuration as modeled. Comparisons with experimental data were very good, indicating the applicability of the patched-grid technique to analyses of these complex geometries.

Jones, Kenneth M.↗

Gravity Induced Formation of Concentration Gradients in Supersaturated Binary Solutions

Experimental and theoretical studies of the formation of solute concentration gradient in supersaturated binary solutions in a gravitational field were carried out. The formation of solute concentration gradient was associated with the gravity induced redistribution of subcritical solute clusters. The birth-death process of the new solute-rich phase domains (subcritical solute clusters) was described in terms of the time-dependent Ginzburg Landau model developed for metastable state relaxation in binary (solute + solvent) non-critical solutions in the presence of a gravitational field. A new mathematical Ansatz was developed for solution of the model equations. This Ansatz has allowed to approach for the first time the following important problems: (1) Microstructure of solute distribution inside of the subcritical solute clusters. The analytical results obtained demonstrate that solute inside of the subcritical solute clusters is heterogeneously distributed with a spatially periodic structure. (2) Macrostructure of the solute subcritical clusters distribution in a gravitational field. The subcritical solute clusters are found to be distributed heterogeneously in a gravitational field. This heterogeneity, which is due to the heterogeneous birth-death process of the subcritical solute clusters in a gravitational field, initiates a noticeable solute concentration gradient in vertical columns of supersaturated binary solutions. An analysis and comparison of theoretical results and experimental data related to the solute concentration gradient formation in a gravitational field are presented. It is also demonstrated that the critical radius of solute clusters (radius of nucleation) and induction time are gravity-dependent.

Izmailov, Alexander F.↗

Accelerated Aging of the M119 Simulator

This paper addresses the storage requirement, shelf life, and the reliability of M119 Whistling Simulator. Experimental conditions have been determined and the data analysis has been completed for the accelerated testing of the system. A general methodology to evaluate the shelf life of the system as a function of the storage time, temperature, and relative humidity is discussed.

Bixon, Eric R.↗

Prognostics of Power MOSFET

This paper demonstrates how to apply prognostics to power MOSFETs (metal oxide field effect transistor). The methodology uses thermal cycling to age devices and Gaussian process regression to perform prognostics. The approach is validated with experiments on 100V power MOSFETs. The failure mechanism for the stress conditions is determined to be die-attachment degradation. Change in ON-state resistance is used as a precursor of failure due to its dependence on junction temperature. The experimental data is augmented with a finite element analysis simulation that is based on a two-transistor model. The simulation assists in the interpretation of the degradation phenomena and SOA (safe operation area) change.

Celaya, Jose Ramon↗