Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Dynamics of tetrahydrofuran as minority component in a mixture with poly(2-(dimethylamino)ethyl methacrylate): A neutron scattering and dielectric spectroscopy investigation

We have investigated a mixture of poly(2-(dimethylamino)ethyl methacrylate) (PDMAEMA) and tetrahydrofuran (THF) (70 wt. % PDMAEMA/30 wt. % THF) by combining dielectric spectroscopy and quasielastic neutron scattering (QENS) on a labelled sample, focusing on the dynamics of the THF molecules. Two independent processes have been identified. The “fast” one has been qualified as due to an internal motion of the THF ring leading to hydrogen displacements of about 3 Å with rather broadly distributed activation energies. The “slow” process is characterized by an Arrhenius-like temperature dependence of the characteristic time which persists over more than 9 orders of magnitude in time. The QENS results evidence the confined nature of this process, determining a size of about 8 Å for the volume within which THF hydrogens’ motions are restricted. In a complementary way, we have also investigated the structural features of the sample. This study suggests that THF molecules are well dispersed among side-groups nano-domains in the polymer matrix, ruling out a significant presence of clusters of solvent. Such a good dispersion, together with a rich mobility of the local environment, would prevent cooperativity effects to develop for the structural relaxation of solvent molecules, frustrating thereby the emergence of Vogel-Fulcher-like behavior, at least in the whole temperature interval investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-surface Thermally Stable Mesoporous Gallium Phosphates Constituted by Nanoparticles as Primary Building Blocks

In constant, search for micro/mesoporous materials, gallium phosphates, have attracted continued interest due to the large pore size reported for some of these solids in comparison with analogous aluminum phosphates. However up to now, the porosity of gallium phosphates collapsed upon template removal or exposure to the ambient moisture. In the present work, we describe high-surface thermally stable mesoporous gallium phosphates synthesized from gallium propoxide and PCl{sub 3} and different templating agents such as amines (dipropylamine, piperidine and aminopiperidine) and quaternary ammonium salts (C{sub 16}H{sub 33}(CH{sub 3})3NBr and C{sub 16}PyCl). These highly reactive precursors have so far not been used as gallium and phosphate sources for the synthesis of gallophosphates. Conceptually, our present synthetic procedure is based on the fast formation of gallium phosphate nanoparticles via the reaction of gallium propoxide with PCl{sub 3} and subsequent construction of the porous material with nanoparticles as building blocks. The organization of the gallophosphate nanoparticles in stable porous structures is effected by the templates. Different experimental procedures varying the molar composition of the sol-gel, pH and the pretreatment of gallium precursor were assayed, most of them leading to satisfactory materials in terms of thermal stability and porosity. In this way, a series of gallium phosphates with surface are above 200 m{sup 2} g{sup -1}, and narrow pore size from 3 to 6 nm and remarkable thermal stability (up to 550 C) have been prepared. In some cases, the structure tends to show some periodicity and regularity as determined by XRD. The remarkable stability has allowed us to test the catalytic activity of gallophosphates for the aerobic oxidation of alkylaromatics with notable good results. Our report reopens the interest for gallophosphates in heterogeneous catalysis.

36 MATERIALS SCIENCE↗

Faulting of natural serpentinite: Implications for intermediate-depth seismicity

The seismic potential of serpentinites at high pressure was investigated via deformation experiments on cored natural serpentinite samples, during which micro-seismicity was monitored by recording Acoustic Emissions (AEs). Deformation was performed at pressures of 3–5 GPa, using a Deformation-DIA device, and over a wide range of temperatures, both within and outside antigorite's stability field. Below 400 °C, serpentinite deformation involves “silent” semi-brittle mechanisms, even in cases where strain localization is observed. At high temperature (i.e., above 600 °C), despite conditions propitious to dehydration embrittlement (i.e., fast strain rates and reaction kinetics), joint deformation and dehydration lead to ductile shear, without generation of AEs. Brittle behavior was observed in a narrow temperature window ca. 500 °C. In this latter case, AEs are consistently observed upon faulting and extremely sharp strain localization is observed in recovered samples. The resulting microstructures are consistent with the inverse ductile-to-brittle transition proposed by Proctor and Hirth (2016) in antigorite. This may therefore be a source of seismicity in subducting slabs at mantle pressures and temperatures from 500 to 600 °C. However, the acoustic signal observed here is orders of magnitude weaker than what is obtained at low PT conditions with brittle failure, consistently with low radiation efficiency of serpentinite faulting (Prieto et al., 2013) and suggests that other mechanisms are responsible for large intermediate-depth earthquakes. In fact, the present results are in line with a recent study (Ferrand et al., 2017), that suggests that intermediate earthquakes are likely induced by mechanical instabilities due to dehydration in partly hydrated peridotites.

58 GEOSCIENCES↗

High Energy X-ray Applications for the Characterization of Metallic Uranium Alloys

Uranium-based metallic alloys are both candidates for fuels in high performance research and test reactors, as well as in fast spectrum reactors as nuclear transmutation fuels that can be utilized to burn long-lived minor actinides and fission products. Uranium-molybdenum (UMo) alloys are under development for the use in research and test reactors. Whereas, uranium-zirconium (U-Zr) alloys represent one of the types of fuels that are under consideration for use within the fast spectrum reactors. Both of these types of metallic fuels have been studied for over five decades in various types of reactors. Many of the previous studies had focused on performance-based aspects. However, recent advances in characterization tools and techniques, as well as short-term (low fluence) neutron irradiation facilities have contributed to a more in-depth understanding of nuclear fuel and material behavior following irradiation. This knowledge is crucial to the enhancement of current modeling and simulation techniques, particularly with respect to parameterization and validation. This paper focuses on the use of high energy x-rays to characterize metallic nuclear fuel. The specimens were composed of depleted uranium (DU) alloyed with either Zr or Mo, where DU-xZr (x = 10, 15, or 20 wt.%) and DU-yMo (y = 7 or 10 wt.%). The geometries of the specimens were 3 mm TEM disks that were ∼200 μm in thickness. The fuel alloys were initially prepared via an arc melting process. The samples were irradiated at the Advanced Test Reactor at Idaho National Laboratory (INL) using the hydraulic rabbit system. The hydraulic rabbit system allows for well-controlled, short term irradiations (less than one cycle), hence resulting in low fluences. The U-based alloys were irradiated to doses of 0.01 and 0.1 dpa. The irradiation temperature of the specimens ranged from 150 deg. C to 800 deg. C. Synchrotron characterization techniques can be used to provide insight into material microstructure ranging a multitude of spatial scales, from the atomic scale to the macroscale. High-energy x-rays at the National Synchrotron Light Source II (NSLS II) and the Advanced Photon Source (APS) have been utilized to understand the microstructural changes in these metallic alloys, specifically with respect to phase identification, phase fractions, chemical bonding, strain, and dislocation density through the use of diffraction and X-ray Absorption Spectroscopy (XAS). These experiments utilized a robot for specimen exchange during the diffraction measurements, allowing for remote handling of radioactive materials. This is an example of another recent advancement in characterization techniques that enables research with nuclear materials. Detailed results of the analyses of the microstructural changes are pending.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Noise in x-ray grating-based phase-contrast imaging

Purpose: Grating-based x-ray phase-contrast imaging is a fast developing new modality not only for medical imaging, but as well for other fields such as material sciences. While these many possible applications arise, the knowledge of the noise behavior is essential. Methods: In this work, the authors used a least squares fitting algorithm to calculate the noise behavior of the three quantities absorption, differential phase, and dark-field image. Further, the calculated error formula of the differential phase image was verified by measurements. Therefore, a Talbot interferometer was setup, using a microfocus x-ray tube as source and a Timepix detector for photon counting. Additionally, simulations regarding this topic were performed. Results: It turned out that the variance of the reconstructed phase is only dependent of the total number of photons used to generate the phase image and the visibility of the experimental setup. These results could be evaluated in measurements as well as in simulations. Furthermore, the correlation between absorption and dark-field image was calculated. Conclusions: These results provide the understanding of the noise characteristics of grating-based phase-contrast imaging and will help to improve image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Short-Term Oxidation Behavior of Model and Commercial Chromia-Forming Ferritic Stainless Steels in Air with Water Vapor

A high-purity Fe-20Cr and commercial type 430 ferritic stainless steel were exposed at 700 and 800 C in dry air and air with 10% water vapor (wet air) and characterized by SEM, XRD, STEM, SIMS, and EPMA. The Fe-20Cr alloy formed a fast growing Fe-rich oxide scale at 700 C in wet air after 24 h exposure, but formed a thin chromia scale at 700 C in dry air and at 800 C in both dry air and wet air. In contrast, thin spinel + chromia base scales with a discontinuous silica subscale were formed on 430 stainless steel under all conditions studied. Extensive void formation was observed at the alloy-oxide interface for the Fe-20Cr in both dry and wet conditions, but not for the 430 stainless steel. The Fe-20Cr alloy was found to exhibit a greater relative extent of subsurface Cr depletion than the 430 stainless steel, despite the former's higher Cr content. Depletion of Cr in the Fe-20Cr after 24 h exposure was also greater at 700 C than 800 C. The relative differences in oxidation behavior are discussed in terms of the coarse alloy grain size of the high-purity Fe-20Cr material, and the effects of Mn, Si, and C on the oxide scale formed on the 430 stainless steel.

08 HYDROGEN↗

High resolution x-ray Thomson scattering measurements from cryogenic hydrogen jets using the linac coherent light source

We present the first spectrally resolved measurements of x-rays scattered from cryogenic hydrogen jets in the single photon counting limit. The 120 Hz capabilities of the LCLS, together with a novel hydrogen jet design [J. B. Kim et al., Rev. Sci. Instrum. (these proceedings)], allow for the ability to record a near background free spectrum. Such high-dynamic-range x-ray scattering measurements enable a platform to study ultra-fast, laser-driven, heating dynamics of hydrogen plasmas. This measurement has been achieved using two highly annealed pyrolytic graphite crystal spectrometers to spectrally resolve 5.5 keV x-rays elastically and inelastically scattered from cryogenic hydrogen and focused on Cornell-SLAC pixel array detectors [S. Herrmann et al., Nucl. Instrum. Methods Phys. Res., Sect. A 718, 550 (2013)].

43 PARTICLE ACCELERATORS↗

Structure and dynamics of POPC bilayers in water solutions of room temperature ionic liquids

Molecular dynamics simulations in the NPT ensemble have been carried out to investigate the effect of two room temperature ionic liquids (RTILs), on stacks of phospholipid bilayers in water. We consider RTIL compounds consisting of chloride ([bmim][Cl]) and hexafluorophosphate ([bmim][PF{sub 6}]) salts of the 1-buthyl-3-methylimidazolium ([bmim]{sup +}) cation, while the phospholipid bilayer is made of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC). Our investigations focus on structural and dynamical properties of phospholipid and water molecules that could be probed by inelastic and quasi-elastic neutron scattering measurements. The results confirm the fast incorporation of [bmim]{sup +} into the lipid phase already observed in previous simulations, driven by the Coulomb attraction of the cation for the most electronegative oxygens in the POPC head group and by sizeable dispersion forces binding the neutral hydrocarbon tails of [bmim]{sup +} and of POPC. The [bmim]{sup +} absorption into the bilayer favours the penetration of water into POPC, causes a slight but systematic thinning of the bilayer, and further stabilises hydrogen bonds at the lipid/water interface that already in pure samples (no RTIL) display a lifetime much longer than in bulk water. On the other hand, the effect of RTILs on the diffusion constant of POPC (D{sub POPC}) does not reveal a clearly identifiable trend, since D{sub POPC} increases upon addition of [bmim][Cl] and decreases in the [bmim][PF{sub 6}] case. Moreover, because of screening, the electrostatic signature of each bilayer is only moderately affected by the addition of RTIL ions in solution. The analysis of long wavelength fluctuations of the bilayers shows that RTIL sorption causes a general decrease of the lipid/water interfacial tension and bending rigidity, pointing to the destabilizing effect of RTILs on lipid bilayers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of kaolin supported nanoscale zero-valent iron and its degradation mechanism of Direct Fast Black G in aqueous solution

Graphical abstract: UV–visible spectra of DFBG solution using K-nZVI (1:1) nanoparticles. (a) Before reaction; (b) during reaction; (c) after reaction. - Highlights: • Kaolin-supported Fe{sup 0} nanoparticle (K-nZVI) was synthesized. • Degradation of Direct Fast Black by K-nZVI was studied. • K-nZVI was characterized by SEM, XRD, UV and FIIR. • Degradation mechanism of Direct Fast Black was proposed. - Abstract: Calcinated kaolin supported nanoscale zero-valent iron (K-nZVI) was synthesized and used for the removal of tetrad azo-group dye-Direct Fast Black G (DFBG) from aqueous solution. The results demonstrated that after reacting for 10 min with an initial concentration of DFBG 100 mg L{sup −1} (pH 9.49), 78.60% of DFBG was removed using K-nZVI, while only 41.39% and 12.56% of DFBG were removed using nZVI and kaolin, respectively. K-nZVI with a mass ratio of nZVI nanoparticles versus kaolin at 1:1 was found to have a high degree of reactivity. Furthermore, scanning electron microscopy (SEM) confirmed that nZVI was better dispersed when kaolin was present. XRD patterns indicated that iron oxides were formed after reaction. Fourier transforms infrared spectra (FTIR) and UV–visible demonstrated that the peak in the visible light region of DFBG was degraded and new bands were observed. Kinetics studies showed that the degradation of DFBG fitted well to the pseudo first-order model. The degradation of DFBG by K-nZVI was based on its adsorption onto kaolin and iron oxides, and subsequently reduction using nZVI was proposed. A significant outcome emerged in that 99.84% of DFBG in wastewater was removed using K-nZVI after reacting for 60 min.

36 MATERIALS SCIENCE↗

High-Resolution Full-Field Structural Microscopy of the Voltage-Induced Filament Formation in VO 2 -Based Neuromorphic Devices

In order to make neuromorphic functions in memristive devices more efficient, information about the structural properties of filament formation at the micro- and mesoscopic scales is necessary. Despite extensive research on VO 2 , a key material due to its filament formation, local operando structural measurements remain challenging and often involve destructive specimen preparation and long rastering times, greatly limiting the scope of experimental studies. Utilizing dark-field X-ray microscopy (DFXM), a fullfield imaging modality, structural signatures of the filament formation process operando are revealed in VO 2 devices. DFXM experiments illustrate that rutile filaments contain isolated monoclinic clusters, indicating structural nonuniformity interior to the filament. The formation of the rutile phase beneath device electrodes was shown to precede filament development, followed by the formation of filament paths guided by nucleation sites within the device. Finally, a medium-term (<30 min) memory mechanism is observed in VO 2 , mediated by sites within the device gap that tend to switch at significantly lower voltages after electrical cycling, a tendency that persists through a brief thermal reset. High spatial resolution, large field-of-view, structure selectivity, and fast signal acquisition of DFXM provided insight into structural features of the filamentary channel and surrounding regions during voltage cycling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bismuth-Polyoxocation Coordination Networks: Controlling Nuclearity and Dimension-Dependent Photocatalysis

Bismuth-oxocluster nodes for metal–organic frameworks (MOFs) and coordination networks/polymers are less prolific than other families featuring zinc, zirconium, titanium, lanthanides, etc. However, Bi 3+ is non-toxic, it readily forms polyoxocations, and its oxides are exploited in photocatalysis. This family of compounds provides opportunity in medicinal and energy applications. Here, we show that Bi node nuclearity depends on solvent polarity, leading to a family of Bi x -sulfonate/carboxylate coordination networks with x = 1–38. Larger nuclearity-node networks were obtained from polar and strongly coordinating solvents, and we attribute the solvent’s ability to stabilize larger species in solution. Here, the strong role of the solvent and the lesser role of the linker in defining node topologies differ from other MOF syntheses, and this is due to the Bi 3+ intrinsic lone pair that leads to weak node–linker interactions. We describe this family by single-crystal X-ray diffraction (eleven structures), obtained in pure forms and high yields. Ditopic linkers include NDS (1,5-naphthalenedisulfonate), DDBS (2,2'-[biphenyl-4,4'-diylchethane-2,1-diyl] dibenzenesulphonate), and NH 2 -benzendicarboxylate (BDC). While the BDC and NDS linkers yield more open-framework topologies that resemble those obtained by carboxylate linkers, topologies with DDBS linkers appear to be in part driven by association between DDBS molecules. An in situ small-angle X-ray scattering study of Bi 38 -DDBS reveals stepwise formation, including Bi 38 -assembly, pre-organization in solution, followed by crystallization, confirming the less important role of the linker. We demonstrate photocatalytic hydrogen (H 2 ) generation with select members of the synthesized materials without the benefit of a co-catalyst. Band gap determination from X-ray photoelectron spectroscopy (XPS) and UV–vis data suggest the DDBS linker effectively absorbs in the visible range with ligand-to-Bi-node charge transfer. In addition, materials containing more Bi (larger Bi 38 -nodes or Bi 6 inorganic chains) exhibit strong UV absorption, also contributing to effective photocatalysis by a different mechanism. All tested materials became black with extensive UV–vis exposure, and XPS, transmission electron microscopy, and X-ray scattering of the black Bi 38 -framework suggest that Bi o is formed in situ, without phase segregation. This evolution leads to enhanced photocatalytic performance, perhaps due to increased light absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interaction of radio frequency waves with cylindrical density filaments: scattering and radiation pressure

The propagation of radio-frequency (RF) waves in tokamaks can be affected by filamentary structures, or blobs, that are present in the edge plasma and the scrape-off layer. The difference in the permittivity between the surrounding plasma and interior of a filament leads to reflection, refraction and diffraction of the waves. This, in turn, can affect the power flow into the core of the plasma and reduce the efficiency of heating and/or current generation. The scattering of RF waves, lower hybrid, helicon and ion cyclotron waves, by a single cylindrical filament, embedded in a background plasma, is studied using a full-wave analytical theory developed previously (Ram & Hizanidis, Phys. Plasmas , vol. 23, 2016, 022504). The theory assumes that the plasma in and around a filament is homogeneous and cold. A detailed scattering analysis reveals a variety of common features that exist among the three distinctly different RF waves. These common attributes can be inferred intuitively based on an examination of the cold plasma dispersion relation. The physical intuition is a useful step to understanding experimental observations on scattering, as well as results from simulations that include general forms of edge plasma turbulence. While a filament can affect the propagation of RF waves, the radiation force exerted by the waves can influence the filament. The force on a filament is determined using the Maxwell stress tensor. In 1905, Poynting was the first to evaluate and measure the radiation force on an interface separating two different dielectric media (Poynting, London Edinburgh Dublin Philos. Mag. J. Sci. , vol. 9, 1905, pp. 393–406). For ordinary light propagating in vacuum and incident on a glass surface, Poynting noted that the surface is ‘pulled’ towards the vacuum. In a magnetized cold plasma, there are two independent wave modes. Even if only one of these modes is excited by an RF antenna, a filament will couple power to the other mode: a consequence of electromagnetic boundary conditions. This facet of scattering has consequences on the radiation force that go beyond Poynting's seminal contribution. The direction of the force depends on the polarization of the incident wave and on the mode structure of the waves inside and in the vicinity of a filament. It can either pull the filament toward the RF source or push it away. For slow lower hybrid waves, filaments with densities greater than the ambient density are pulled in, while filaments with lower densities are pushed out, thereby enhancing the density in front of the antenna. In the case of fast helicon and ion cyclotron waves, the direction of the force depends on the plasma and wave parameters; in particular, on the ambient density. The radiation force, in all three frequency ranges, is large enough to affect the motion of a filament and could be measured experimentally. This also suggests the possibility of modifying the edge turbulence using RF waves.

Physics↗

Interaction of radio frequency waves with cylindrical density filaments -- scattering and radiation pressure

The propagation of radio-frequency (RF) waves in tokamaks can be affected by filamentary structures, or blobs, that are present in the edge plasma and the scrape-off layer. The difference in the permittivity between the surrounding plasma and interior of a filament leads to reflection, refraction and diffraction of the waves. This, in turn, can affect the power flow into the core of the plasma and reduce the efficiency of heating and/or current generation. The scattering of RF waves, lower hybrid, helicon and ion cyclotron waves, by a single cylindrical filament, embedded in a background plasma, is studied using a full-wave analytical theory developed previously (Ram & Hizanidis, Phys. Plasmas, vol. 23, 2016, 022504). The theory assumes that the plasma in and around a filament is homogeneous and cold. A detailed scattering analysis reveals a variety of common features that exist among the three distinctly different RF waves. These common attributes can be inferred intuitively based on an examination of the cold plasma dispersion relation. The physical intuition is a useful step to understanding experimental observations on scattering, as well as results from simulations that include general forms of edge plasma turbulence. While a filament can affect the propagation of RF waves, the radiation force exerted by the waves can influence the filament. The force on a filament is determined using the Maxwell stress tensor. In 1905, Poynting was the first to evaluate and measure the radiation force on an interface separating two different dielectric media (Poynting, London Edinburgh Dublin Philos. Mag. J. Sci., vol. 9, 1905, pp. 393–406). For ordinary light propagating in vacuum and incident on a glass surface, Poynting noted that the surface is ‘pulled’ towards the vacuum. In a magnetized cold plasma, there are two independent wave modes. Even if only one of these modes is excited by an RF antenna, a filament will couple power to the other mode: a consequence of electromagnetic boundary conditions. This facet of scattering has consequences on the radiation force that go beyond Poynting's seminal contribution. The direction of the force depends on the polarization of the incident wave and on the mode structure of the waves inside and in the vicinity of a filament. It can either pull the filament toward the RF source or push it away. For slow lower hybrid waves, filaments with densities greater than the ambient density are pulled in, while filaments with lower densities are pushed out, thereby enhancing the density in front of the antenna. In the case of fast helicon and ion cyclotron waves, the direction of the force depends on the plasma and wave parameters; in particular, on the ambient density. The radiation force, in all three frequency ranges, is large enough to affect the motion of a filament and could be measured experimentally. This also suggests the possibility of modifying the edge turbulence using RF waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and Perspectives for a Slow Positron Beam Facility at the HH--NIPNE Bucharest

The development of a positron annihilation spectroscopy laboratory at the HH-NIPNE Bucharest-to be used for material studies and applications was started in the last 10 years. In the framework of a national research project extended over the last 3 years, was designed a low energy positron accelerator, as a high-vacuum dedicated beam line with two options: a 25 mCi {sup 22}NaCl source and in line with the NIPNE-cyclotron or a new intense compact cyclotron. The construction of the beam line was planned as a sequence of modules: source- moderator system; magnetical filter for fast positrons in order to select the positrons energies in the range 0.8-1 keV; a modular system for focusing, transport and acceleration of monoenergetic positrons in the energy range 0.8-50 keV and a CDBS analysis chamber. The moderator proposed--is tungsten as a foil of about 3 {mu}m prepared at the Optoelectronics Institute were put into a thermal treatment vacuum chamber and bombarded with electrons from a 100 W electron gun After the treatment, they were tested for changes of elemental composition of the surface and structure at the Polytechnic University. The structure tests were performed on a DRON 3 M diffractometer, with a Co tube ({lambda}{sub K{alpha}} = 1.7903 A) - the angular regions studied were around 34 deg. (1 0 0) and 69 deg. (2 0 0). In the present time, the trajectories of the positron are going to be simulated with dedicated software (an ion and electron optics simulator). For the coincidence measurements (CDBS) set-up we used a home-made {sup 22}NaCl source, by separation without carrier from a metallic Mg target irradiated with 12 MeV protons and separated by columnar cation exchange. A home-made biparametric system for CDBS measurements will be reported, also.

43 PARTICLE ACCELERATORS↗

NiAl{sub 2}O{sub 4} catalysts prepared by combustion reaction using glycine as fuel

Graphical abstract: The reaction temperature was found to remain is practically constant throughout the interval preceding ignition, after which the temperature increased abruptly, reaching the maximum combustion temperature. All the reactions occurred in a matter of minutes, i.e., 5.8, 5.8 and 6 min, respectively, for compositions GES, 10GE and 20GE. Among the benefits of the combustion synthesis method are low processing cost, energy efficiency, high production rate and, especially, short reaction periods when compared with conventional methods (solid state reaction) to prepare ceramic oxide powders that require high calcination temperatures and long reaction periods. Highlights: {yields} We use a simple, fast and inexpensive technique for processing NiAl{sub 2}O{sub 4} catalyst nanopowders. {yields} We study the preparation of powders with nanometric sized particles. {yields} This material is extremely attractive for use in the development of new catalysts for a variety of chemical processes. {yields} Nanometric sized particles depend of the amount of glycine used in the synthesis process. -- Abstract: The aim of this work is to evaluate the influence of glycine fuel used in a stoichiometric proportion and with a 10% and 20% excess of this fuel in the preparation of NiAl{sub 2}O{sub 4} catalyst by combustion reaction. The powders were characterized by XRD, textural analysis by the BET nitrogen adsorption method, particle size distribution, and FTIR. The results show the presence of NiAl{sub 2}O{sub 4} as a major phase and traces of NiO and Ni in all the catalysts studied here. The crystallite sizes were 22 nm in the stoichiometric composition and 18 and 9 nm, respectively, in the composition containing 10% and 20% excess glycine. The powder obtained from all the compositions presented morphological characteristics with irregular plate-shaped agglomerates. The increase in excess glycine caused the particle size in the three compositions to decrease to 59, 54 and 38 nm and the agglomerate size to increase to 7, 8 and 12 {mu}m, respectively.

36 MATERIALS SCIENCE↗

A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation

HASE (Highly Automated Sputter Equipment) is a new mobile setup developed to investigate deposition processes with synchrotron radiation. HASE is based on an ultra-high vacuum sputter deposition chamber equipped with an in-vacuum sample pick-and-place robot. This enables a fast and reliable sample change without breaking the vacuum conditions and helps to save valuable measurement time, which is required for experiments at synchrotron sources like PETRA III at DESY. An advantageous arrangement of several sputter guns, mounted on a rotative flange, gives the possibility to sputter under different deposition angles or to sputter different materials on the same substrate. The chamber is also equipped with a modular sample stage, which allows for the integration of different sample environments, such as a sample heating and cooling device. The design of HASE is unique in the flexibility. The combination of several different sputtering methods like standard deposition, glancing angle deposition, and high pressure sputter deposition combined with heating and cooling possibil-ities of the sample, the large exit windows, and the degree of automation facilitate many different grazing incidence X-ray scattering experiments, such as grazing incidence small and wide angle X-ray scattering, in one setup. In this paper we describe in detail the design and the performance of the new equipment and present the installation of the HASE apparatus at the Micro and Nano focus X-ray Scattering beamline (MiNaXS) at PETRA III. Furthermore, we describe the measurement options and present some selected results. The HASE setup has been successfully commissioned and is now available for users.

43 PARTICLE ACCELERATORS↗

Recent development of the Multi-Grid detector for large area neutron scattering instruments

Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternative techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with standard equipment. Prototypes of different configurations and sizes have been developed and tested. A demonstrator, with a sensitive area of 0.8 m x 3 m, has been studied during the CRISP European project; it contains 1024 grids, and a surface of isotopically enriched B{sub 4}C film close to 80 m{sup 2}. Its size represented a challenge in terms of fabrication and mounting of the detection elements. Another challenge was to make the gas chamber mechanically compatible with operation in a vacuum TOF chamber. Optimal working condition of this detector was achieved by flushing Ar-CO{sub 2} at a pressure of 50 mbar, and by applying 400 Volts on the anodes. This unusual gas pressure allows to greatly simplifying the mechanics of the gas vessel in vacuum. The detection efficiency has been measured with high precision for different film thicknesses. 52% has been measured at 2.5 Angstrom, in good agreement with the MC simulation. A high position resolution has been achieved by centre of gravity measurement of the TOT (Time-Over-Threshold) signals between neighbouring grids. These results, as well as other detection parameters, including gamma sensitivity and spatial uniformity, will be presented. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)

Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.

60 APPLIED LIFE SCIENCES↗