Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Studies of a Space Lidar Instrument for the ASCENDS Mission

We have developed a lidar technique for measuring the tropospheric C02 concentrations as a candidate for NASA's planned ASCENDS mission. Our technique uses two pulsed laser transmitters allowing simultaneous measurement of a C02 absorption line in the 1570 nm band, 02 extinction in the Oxygen A-band and surface height and backscatter. The lidar measures the energy and time of flight of the laser echoes reflected from the atmosphere and surface. The lasers are stepped in wavelength across the C02 line and an 02 line region during the measurement. The receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the C02 and 02 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. Pulsed laser signals and a time gated receiver are used to isolate the laser echo signals from the surface, to reject laser photons scattered in the atmosphere, and measure the surface height and scattering profile in the path. We have recently completed a second design study for the space instrument. For the study, we selected a nominal sun-synchronous orbit with an altitude of 400 km and equator crossing time of 1:30 pm, and a receiver telescope with 1.5 m diameter.

Abshire, J. B.↗

He-Ne and CW CO2 laser long-path systems for gas detection

This paper describes the design and testing of a laboratory prototype dual He-Ne laser system for the detection of methane leaks from underground pipelines and solid-waste landfill sites using differential absorption of radiation backscattered from topographic targets. A laboratory-prototype dual CW carbon dioxide laser system also using topographic backscatter is discussed, and measurement results for methanol are given. With both systems, it was observed that the time-varying differential absorption signal was useful in indicating the presence of a gas coming from a nearby source. Limitations to measurement sensitivity, especially the role of speckle and atmospheric turbulence, are described. The speckle results for hard targets are contrasted with those from atmospheric aerosols. The appendix gives appropriate laser lines and values of absorption coefficients for the hydrazine fuel gases.

Grant, W. B.↗

Measurement of the dispersive and refractive indices of germanium using diode lasers

Germanium Fabry-Perot etalons are commonly used in diode laser spectroscopy to establish relative frequency calibration scales for molecular absorption spectra. Typically the channel spectrum of the etalon is recorded simultaneously with the molecular spectrum as the laser injection current is tuned linearly, and the etalon free spectral range (fringe spacing) is used to measure the frequency separations among lines in the molecular spectrum. For this purpose, the etalon free spectral range must be known for the measurement wavelength, and this in turn relies on knowledge of the etalon length and the dispersive index at this wavelength. It is pointed out that the most satisfactory approach is to measure directly the free spectral range or dispersive index of the etalon at the wavelength of interest. A description is presented of measurements of this type, performed near 7.9 and 10.1 micrometers for a 7.7-cm long germanium etalon.

Jennings, D. E.↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

TerraHertz Free Electron Laser Applications for Satellite Remote Sensing

The development of a Free Electron Laser (EL) operating in the terahertz frequency regime by the group at the University of Hawaii (Elias et al.) represents a significant new opportunity in the area of atmospheric remote sensing. The FEL has 2 salient features that create a unique opportunity. First of all it represents the only source in this frequency range with sufficient power to enable lidar instrumentation. Secondly its very high electrical efficiency (several times more efficient than any currently employed spaceborne laser) renders it a strong candidate for use in satellite remote sensing. On the negative side the atmosphere is rather strongly absorbing throughout this frequency range due primarily to the water vapor continuum absorption. This means that the instruments using this laser will not be able to access the lower troposphere because of its very high water concentration.. However the instrument will be very capable of measurements in the upper troposphere and stratosphere. A passive instrument, the Microwave Limb Sounder on the UARS satellite operated by Jet Propulsion Laboratory, has already demonstrated that this wavelength region can be used for chemical species with strong emission lines. A lidar would complement the capabilities of this instrument by providing the capability to measure absorbing species in the upper atmosphere. I will discuss the design of such an instrument in greater detail and estimate its performance in measuring a number of chemical species of interest to the Earth Science community.

Heaps, William S.↗

Yb fiber laser pumped mid-IR source based on difference frequency generation and its application to ammonia detection

A Yb fiber laser pumped cw narrow-linewidth tunable mid-IR source based on a difference frequency generation (DFG) in a periodically poled LiNbO3 (PPLN) crystal for trace gas detection was demonstrated. A high power Yb fiber laser and a distributed feedback (DFB) laser diode were used as DFG pump sources. This source generated mid-IR at 3 microns with a powers of ~2.5 microW and a spectral linewidth of less than 30 MHz. A frequency tuning range of 300 GHz (10 cm-1) was obtained by varying the current and temperature of the DFB laser diode. A high-resolution NH3 absorption Doppler-broadened spectrum at 3295.4 cm-1 (3.0345 microns) was obtained at a cell pressure of 27 Pa from which a detection sensitivity of 24 ppm m was estimated.

NASA Discipline Environmental Health↗

Approaching the Lower Temporal Limit of Laser‐Produced Plasma Sources for Table‐Top Soft X‐Ray NEXAFS Measurements

Abstract The increasing popularity of time‐resolved X‐ray absorption measurements for understanding dynamics in molecular and material systems has led to many advances in table‐top sources for pulsed X‐rays. We report on a table‐top laser‐produced plasma (LPP) source that can perform soft X‐ray (SXR), near‐edge X‐ray absorption fine structure (NEXAFS) measurements using a laser source with 23 ps pulse duration. The spectrometer's key specifications, such as brilliance, resolution, and stability, are characterized against the more commonly used longer‐pulse‐duration LPP sources. The 23 ps laser produced approximately an order of magnitude weaker SXR flux than the 8 ns laser for a higher power density due to the smaller total energy absorbed by the plasma. The increased repetition rate, as well as the use of a high line‐density X‐grating, and a self‐referencing scheme still allowed for NEXAFS measurements of Si 3 N 4 and TiO 2 thin films with 2.5 minute acquisition times, a resolving power of E/ΔE=424, and a signal‐to‐noise ratio of 100. It was observed that degradation of the gas jet nozzle led to long‐term instability of the source, which can be remediated using alternative nozzle designs. This work demonstrates the feasibility of achieving higher temporal resolution in future time‐resolved X‐ray absorption measurements using table‐top LPP sources.

Nimlos, Danika [Division of Chemistry and Chemical↗

Infrared heterodyne spectrometer measurements of vertical profile of tropospheric ammonia and ozone

Remote sensing of the concentration and vertical distribution of atmospheric gases has been carried out using a dual CO2 laser multichannel infrared heterodyne spectrometer (IHS). The high specificity and nearly quantum-noise-limited sensitivity of the IHS provide the capability of scanning individual signature lines of selected atmospheric constituents in the 9 to 11 micron region. A comprehensive investigation of the spectral overlap between CO2 laser local oscillator transitions and selected atmospheric constituents was performed; measurements of the atmospheric absorption of solar radiation from the ground were carried out at selected laser transitions for ammonia and ozone.

Peyton, B. J.↗

Far infrared maser communications technology

An optically pumped FIR laser was constructed and tested. Optimum operating conditions were determined with CH3OH as the lasing medium. The laser was found to operate equally well with flowing gas or in a sealed off configuration. The FIR cavity stability and pump laser stability were found to have significant problems. The absorption coefficient per unit pressure of 1-1 difluoroethylene at the P(22) and P(24) lines of the 10.4 micron CO2 band was measured. The FIR line pumped by P(22) occurs at approximately 890 microns, which may be in an atmospheric transmission window. It was found that significant Stark tuning of absorption lines of methanol and 1-1 difluoroethylene can be accomplished, even at the usual 100 to 300 mTorr operating pressures of FIR lasers. This means that the use of Stark tuning may enable more effective use of pump laser output.

Claspy, P. C.↗

Tunable lasers and their application in analytical chemistry

The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.

Steinfeld, J. I.↗

Fiber-Based Laser Transmitter at 1.57 Micrometers for Remote Sensing of Atmospheric Carbon Dioxide from Satellites

Over the past 20 years, NASA Goddard has successfully developed space-based lidar for remote sensing studies of the Earth and planets. The lidar in all missions to date have used diode pumped Nd:YAG laser transmitters. Recently we have been concentrating work on developing integrated path differential absorption (IPDA) lidar to measure greenhouse gases, with the goal of measurements from space. Due to the absorption spectrum of CO2 a fiber-based master oscillator power amplifier (MOPA) laser with a tunable seed source is an attractive laser choice. Fiber-based lasers offer a number of potential advantages for space, but since they are relatively new, challenges exist in developing them. In order to reduce risks for new missions using fiber-based lasers, we developed a 30- month plan to mature the technology of a candidate laser transmitter for space-based CO2 measurements to TRL-6. This work is also intended to reduce development time and costs and increase confidence in future mission success.

Fiber Lasers↗

A modified pump laser system to pump the titanium sapphire laser

As a result of the wide tunability of the titanium sapphire laser NASA has sited it to be used to perform differential absorption lidar (DIAL) measurements of H2O vapor in the upper and lower troposphere. The titanium sapphire laser can provide a spectrally narrow (0.3 to 1.0 pm), high energy (0.5 to 1.0 J) output at 727, 762, and 940 nm which are needed in the DIAL experiments. This laser performance can be obtained by addressing the line-narrowing issues in a master oscillator and the high energy requirement in a fundamental mode oscillator. By injection seeding, the single frequency property of the master oscillator can produce a line narrow high energy power oscillator. A breadboard model of the titanium sapphire laser that will ultimately be used in NASA lidar atmospheric sensing experiment is being designed. The task was to identify and solve any problem that would arise in the actual laser system. One such problem was encountered in the pump laser system. The pump laser that is designed to pump both the master oscillator and power oscillator is a Nd:YLF laser. Nd:YLF exhibits a number of properties which renders this material an attractive option to be used in the laser system. The Nd:YLF crystal is effectively athermal; it produces essentially no thermal lensing and thermally induced birefringence is generally insignificant in comparison to the material birefringence resulting from the uniaxial crystal structure. However, in application repeated fracturing of these laser rods was experience. Because Nd:YLF rods are not commercially available at the sizes needed for this application a modified pump laser system to replace the Nd:YLF laser rod was designed to include the more durable Nd:YAG laser rods. In this design, compensation for the thermal lensing effect that is introduced because of the Nd:YAG laser rods is included.

Petway, Larry B.↗

Atmospheric transmission coefficients for laser pulses with spectral widths of a few tenths of a nanometer over the wavelength region from 800 to 860 nanometers

Effective atmospheric transmission spectra were calculated from 800 to 860 nanometers for laser sources with spectral widths of a few tenths of a nanometer. In this spectral region, the atmospheric absorption lines (water lines) have linewidths of a few hundredths of a nanometer, so that the transmission coefficient for a relatively wide laser pulse must be computed by taking a weighted average over the pulse spectral width. Laser spectral widths of several tenths of a nanometer are shown to reduce the effective absorption by water lines to as little as 10 to 20 percent, even when the laser is centered on a line or overlaps several lines. Thus, the effect of absorption by atmospheric water lines may be greatly reduced for laser communication systems using laser diode array transmitters, for which the pulse spectral width may be a few tenths of a nanometer.

Safren, H. G.↗

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.↗

High-Resolution Thermal Profiling of a High-Power Diode Laser Facet During Aging

Here, we study the facet temperature distribution of a high-power diode laser over its lifetime using a noncontact, high spatial resolution CCD-based thermoreflectance technique. Based on the known correlation between non-radiative defects and heating, thermal maps can provide valuable information regarding the formation and evolution of small point defects that are at or near the facet during aging. In the laser under study in this work we measure the appearance of local hot spots on the facet, including concentrated hot spots that appear just before or just after COD and are correlated with loss of local light emission. The locations of these hot spots do not exhibit morphology changes in high-resolution SEM imaging of the facet, indicating that the related defects are too small to be observable in SEM or are located at some depth under the facet. Prior to COD, we measure a gradual facet temperature increase accompanied by a gradual optical power decrease and gradual facet optical absorption increase, indicating gradual degradation of the laser.

47 OTHER INSTRUMENTATION↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

On the possibility of measuring atmospheric OH using intracavity laser spectroscopy

Intracavity laser spectroscopy (ILS) has been demonstrated to be useful for measuring extremely weak absorption produced by gases in air. ILS is based on the observation that when there are spectrally narrow losses within the cavity of a broadband laser, the laser output has corresponding spectral holes where the laser oscillation is partially quenched. The depth of the laser output dips can be enhanced by a factor of 10(exp 5) over the depth of the initial cavity loss, and absorptivities of 10(exp -8) cm(exp -1) have been measured in lasers only one meter long. With ILS, one can achieve in a compact space a spectral contrast that would otherwise require kilometers of pathlength. ILS systems typically use quasi-continuous wave dye lasers operating close to threshold. The pump laser is modulated from just below to just above the threshold level for the dye laser, and the dye laser output is spectroscopically observed during a well defined time interval after the onset of lasing (the generation time). The spectral contrast of an intracavity absorber is equivalent to that produced by absorption through a path length equal to the generation time multiplied by the speed of light (assuming the cavity is completely filed with the absorber) up to some limiting time. Thus, if one measures the spectrum after 33 microseconds, the effective path length is 10,000 meters.

Mcmanus, J. Barry↗

Two-frequency laser-induced fluorescence technique for rapid velocity-field measurements in gas flows

A technique is presented for measurements of two-dimensional velocity fields in gas flows. The single-mode frequency of an argon-ion laser is fixed in the wing of an absorption line of iodine molecules that are seeded at low level in the flow of interest. The emitted fluorescence is detected with an image-intensified 100 x 100 photodiode-array camera. two pairs of counterpropagating laser sheets sequentially probe the flow to determine two velocity components. The frequency in one pair is shifted with respect to the other by an acousto-optic modulator. This two-frequency scheme eliminates the need to determine the slope of the line externally and offers the potential for combined pressure and velocity-field measurements.

Hiller, B.↗