Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Effect of motion cues during complex curved approach and landing tasks: A piloted simulation study

A piloted simulation study was conducted to examine the effect of motion cues using a high fidelity simulation of commercial aircraft during the performance of complex approach and landing tasks in the Microwave Landing System (MLS) signal environment. The data from these tests indicate that in a high complexity MLS approach task with moderate turbulence and wind, the pilot uses motion cues to improve path tracking performance. No significant differences in tracking accuracy were noted for the low and medium complexity tasks, regardless of the presence of motion cues. Higher control input rates were measured for all tasks when motion was used. Pilot eye scan, as measured by instrument dwell time, was faster when motion cues were used regardless of the complexity of the approach tasks. Pilot comments indicated a preference for motion. With motion cues, pilots appeared to work harder in all levels of task complexity and to improve tracking performance in the most complex approach task.

Scanlon, Charles H.↗

Refinement of Objective Motion Cueing Criteria Investigation Based on Three Flight Tasks

The objective of this paper is to refine objective motion cueing criteria for commercial transport simulators based on pilots' performance in three flying tasks. Actuator hardware and software algorithms determine motion cues. Today, during a simulator qualification, engineers objectively evaluate only the hardware. Pilot inspectors subjectively assess the overall motion cueing system (i.e., hardware plus software); however, it is acknowledged that pinpointing any deficiencies that might arise to either hardware or software is challenging. ICAO 9625 has an Objective Motion Cueing Test (OMCT), which is now a required test in the FAA's part 60 regulations for new devices, evaluating the software and hardware together; however, it lacks accompanying fidelity criteria. Hosman has documented OMCT results for a statistical sample of eight simulators which is useful, but having validated criteria would be an improvement. In a previous experiment, we developed initial objective motion cueing criteria that this paper is trying to refine. Sinacori suggested simple criteria which are in reasonable agreement with much of the literature. These criteria often necessitate motion displacements greater than most training simulators can provide. While some of the previous work has used transport aircraft in their studies, the majority used fighter aircraft or helicopters. Those that used transport aircraft considered degraded flight characteristics. As a result, earlier criteria lean more towards being sufficient, rather than necessary, criteria for typical transport aircraft training applications. Considering the prevalence of 60-inch, six-legged hexapod training simulators, a relevant question is "what are the necessary criteria that can be used with the ICAO 9625 diagnostic?" This study adds to the literature as follows. First, it examines well-behaved transport aircraft characteristics, but in three challenging tasks. The tasks are equivalent to the ones used in our previous experiment, allowing us to directly compare the results and add to the previous data. Second, it uses the Vertical Motion Simulator (VMS), the world's largest vertical displacement simulator. This allows inclusion of relatively large motion conditions, much larger than a typical training simulator can provide. Six new motion configurations were used that explore the motion responses between the initial objective motion cueing boundaries found in a previous experiment and what current hexapod simulators typically provide. Finally, a sufficiently large pilot pool added statistical reliability to the results.

motion simulation↗

Intrinsic size dependent plasticity in BCC micro-pillars under uniaxial tension and pure torsion

The mechanical behavior of submicron body-centered cubic (BCC) micro-pillars is investigated by three-dimensional dislocation dynamics (DD) simulations to better understand the governing mechanisms for size dependent plasticity under uniaxial tension and pure torsion. A formula is developed to compute the incremental plastic twist due to dislocation motion in DD simulations. The DD simulations show that different dislocation microstructures are created depending on the loading conditions, which leads to different size dependent mechanical behavior. While in tension plasticity is mainly governed by the kinetics of dislocation motion controlled partly by the surface dislocation sources, plastic flow in torsion is controlled by dislocation pile-ups associated with strain gradients. The simulation results also reveal a Bauschinger effect and plastic recovery under cyclic twist, which have been observed in recent experiments.

36 MATERIALS SCIENCE↗

A comparison of the noise produced by a small jet on a moving vehicle with that in a free jet

A 2.54 cm (1.00 in.) nozzle supplied with nitrogen was mounted above an automobile and driven over an asphalt roadway past stationary microphones in an attempt to quantify the effects of the vehicle motion on jet mixing noise. The nozzle was then tested in the Langley anechoic noise facility with a large free jet simulating the relative motion. The results are compared for these two methods of investigating forward speed effects on jet mixing noise. The vehicle results indicate a noise with forward speed throughout the Doppler-shifted static spectrum. This decrease across the entire frequency range was also apparent in the free-jet results. The similarity of the results indicates that the effects of flight on jet mixing noise can be predicted by simulation of forward speed with a free jet. Overall sound pressure levels were found to decrease with forward speed at all observation angles for both methods of testing.

Norum, T. D.↗

Expanding the computational frontier of multi-scale atmospheric simulation to advance understanding of low cloud / climate feedbacks: Final Technical Report

Marine boundary layer clouds are a challenge for climate models. They cover much of the oceans, but they are driven by small-scale turbulent eddies only a few hundred meters across, which in turn respond to the cloud formation. Global climate models have a grid spacing that is far too large to simulate such fluid motions, so they parameterize these cloud formation processes. Different climate modeling groups have designed different parameterizations in which the clouds turn out to be differently sensitive to a warming climate. This drives uncertainties in our best guess at the sensitivity of global warming to greenhouse gas increases. If these cloud-forming eddies could be directly simulated using the well-known equations of fluid motion, they would no longer need to be parameterized, removing a major source of climate modeling uncertainty. In this project, we overcame software engineering challenges to successfully implemented ‘ultraparameterization’ (UP), the first global model that does this, and we tested how well it works. We simulated five-year periods with present-day temperatures and with a warmer climate, and we investigated how the UP-simulated clouds responded to climate – the ‘cloud feedback’ problem. We found little response of clouds at all latitudes to the imposed climate change, which is within the range of predictions of conventional global climate models. UP is a variation on superparameterization, in which small cloud-resolving models (CRMs) are embedded in each column of the global model. In UP, the CRM grid is fine enough (250 m horizontal × 20 m vertical) to explicitly capture boundary-layer turbulent eddies and associated clouds. Because only one small columnar patch is simulated within each climate model grid cell, this is a million-fold more efficient than simulating the entire globe on this same CRM grid., but achieves much of the same effect for the cloud properties. It doesn’t work perfectly. For instance, like conventional climate models, UP simulates too little subtropical stratocumulus cloud, a bias that we are continuing to work to reduce. However, because it directly simulates the turbulent cloud-forming processes, UP is inherently more plausible for simulating how clouds will change in a perturbed climate. In future, we hope to apply UP to another key climate modeling issue: cloud-aerosol interaction and the effect of human-produced aerosols on the climate change we have already experienced and that which is likely to come.

54 ENVIRONMENTAL SCIENCES↗

A Nonergodic Ground-Motion Model for the San Francisco Bay Area for Small-Magnitude Earthquakes

ABSTRACT Recently, generative models have become a computationally efficient alternative to physics-based numerical simulations of ground motions. Neural networks can learn from existing ground-motion data to generate unobserved ground-motion data at new source and site locations. A key challenge with generative models is ensuring that predicted ground motions remain within a physically realistic range. For this purpose, we developed an empirical, nonergodic ground-motion model (GMM) for small-magnitude earthquakes in the San Francisco Bay area based on about 5000 recordings per component for Mw ≤ 4 earthquakes. The nonergodic GMM predicts spatially varying median source, site, and path effects for both the Fourier amplitude spectrum (FAS) and the Fourier phase derivative (a proxy for duration), as well as the corresponding epistemic uncertainty for each term. For FAS, our model shows above-average source and site effects in the western part of the region and below-average effects in the eastern part, with regional effects exhibiting larger spatial correlation lengths with increasing frequency. For duration, the source term is negligible for small-magnitude earthquakes, and the site term leads to site-specific variations up to 5 s. Path effects for FAS and duration depend on the source–site pair and are extrapolated spatially using recent methods for path-effect modeling. The aleatory variability of the within-site within-path residuals is similar to the variability found in previous studies for other regions. The nonergodic model provides two key contributions: first, median adjustment terms that are transferable to larger magnitude earthquakes, further reducing aleatory variability in probabilistic seismic hazard analysis; second, region-specific criteria for validating machine learning-based ground-motion generators to evaluate whether synthetic ground motions exhibit physically realistic source, site, and path effects.

Lacour, Maxime↗

Verification and compensation of respiratory motion using an ultrasound imaging system

Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm displacement resulted in compensation rates of 60%–84.4%. Conclusions: This study has shown that a respiratory compensating system combined with noninvasive ultrasound can provide real-time compensation of the respiratory motion of patients.

60 APPLIED LIFE SCIENCES↗

Integrated dynamic analysis simulation of space stations with controllable solar array

A methodology is formulated and presented for the integrated structural dynamic analysis of space stations with controllable solar arrays and non-controllable appendages. The structural system flexibility characteristics are considered in the dynamic analysis by a synthesis technique whereby free-free space station modal coordinates and cantilever appendage coordinates are inertially coupled. A digital simulation of this analysis method is described and verified by comparison of interaction load solutions with other methods of solution. Motion equations are simulated for both the zero gravity and artificial gravity (spinning) orbital conditions. Closed loop controlling dynamics for both orientation control of the arrays and attitude control of the space station are provided in the simulation by various generic types of controlling systems. The capability of the simulation as a design tool is demonstrated by utilizing typical space station and solar array structural representations and a specific structural perturbing force. Response and interaction load solutions are presented for this structural configuration and indicate the importance of using an integrated type analysis for the predictions of structural interactions.

Heinrichs, J. A.↗

Prospects for constraining the spin of the massive black hole at the galactic center via the relativistic motion of a surrounding star

In this paper, we investigate the quality of constraining the spin of the massive black hole (MBH) at the Galactic center (GC) by using full general relativistic simulations of the motion of a surrounding star. We obtain the dependence mapping of the spin-induced signals on any spin direction of the MBH for given example stars, which indicates the feasibility to test whether the spin direction is the same as the normal of the young stellar disk located at the GC, and, further, to provide insights into the assembly history of the MBH. We demonstrate the quality of constraining the MBH spin that may be achieved, given any set of the astrometric and the redshift precisions of observational facilities. We find that in the ranges of the astrometric and the velocity precisions with 1–30 μas and 0.1–10 km s{sup −1}, an improvement in astrometric precision would be more effective at improving the quality of constraining the spin than an improvement in velocity precision. We obtain the parameter space of the semimajor axis and the eccentricity for the orbit of the target star that a high-precision constraint on the GC MBH spin can be obtained via the motion of the star. Our results show that the spin of the GC MBH can be constrained with a 1σ error ≲0.1 or even ≲0.02 by monitoring the orbital motion of a star, if existing as expected, with a semimajor axis ≲300 au and eccentricity ≳0.95 over a period shorter than a decade through future facilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental validation of the van Herk margin formula for lung radiation therapy

Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available within ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatial arrangement of dynamic surface species from solid-state NMR and machine learning-accelerated MD simulations

Here, the surface arrangement of motional organic functionalities is explored by experimental dipolar coupling measurements and the prediction of motionally-averaged coupling constant from molecular dynamics simulations. The use of machine learning potentials was key to reaching the timescale required. The distance between dynamic surface species are important in cooperative heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of seismic velocity models in southern California with full-waveform simulations

SUMMARY Crustal seismic velocity models provide essential information for many applications including earthquake source properties, simulations of ground motion and related derivative products. We present a systematic workflow for assessing the accuracy of velocity models with full-waveform simulations. The framework is applied to four regional seismic velocity models for southern California: CVM-H15.11, CVM-S4.26, CVM-S4.26.M01 that includes a shallow geotechnical layer, and the model of Berg et al. For each model, we perform 3-D viscoelastic wave propagation simulations for 48 virtual seismic noise sources (down to 2 s) and 44 moderate-magnitude earthquakes (down to 2 s generally and 0.5 s for some cases) assuming a minimum shear wave velocity of 200 m s–1. The synthetic waveforms are compared with observations associated with both earthquake records and noise cross-correlation data sets. We measure, at multiple period bands for well-isolated seismic phases, traveltime delays and normalized zero-lag cross-correlation coefficients between the synthetic and observed data. The obtained measurements are summarized using the mean absolute derivation of time delay and the mean correlation coefficient. These two metrics provide reliable statistical representations of model quality with consistent results in all data sets. In addition to assessing the overall (average) performance of different models in the entire study area, we examine spatial variations of the models’ quality. All examined models show good phase and waveform agreements for surface waves at periods longer than 5 s, and discrepancies at shorter periods reflecting small-scale heterogeneities and near-surface structures. The model performing best overall is CVM-S4.26.M01. The largest misfits for both body and surface waves are in basin structures and around large fault zones. Inaccuracies generated in these areas may affect tomography and model simulation results at other regions. The seismic velocity models for southern California can be improved by adding better resolved structural representations of the shallow crust and volumes around the main faults.

58 GEOSCIENCES↗

Hybrid simulations of plasma transport by Kelvin-Helmholtz instability at the magnetopause: magnetic shear

Two-dimensional hybrid (kinetic ions, massless fluid electrons) simulations of the Kelvin Helmholtz Instability (KHI) for a magnetopause configuration with a magnetic shear across the boundary are carried out to examine how the transport of magnetosheath plasma into the magnetosphere is affected by the shear field. Low magnetic shear conditions where the magnetosheath magnetic field is within 30{sup o} of northward is included in the simulations because KHI is thought to be important for plasma transport only for northward or near-northward interplanetary magnetic field orientations. The simulations show that coherent vortices can grow for these near-northward angles, and that they are sometimes more coherent than for pure northward conditions because the turbulence which breaks-down these vortices is reduced when there are magnetic tension forces. With increasing magnetic shear angle, the growth rate is reduced, and the vortices do not grow to as large of size which reduces the plasma transport. By tracking the individual particle motions diffusion coefficients can be obtained for the system, where the diffusion is not classical in nature but instead has a time dependence resulting from both the increasingly large-scale vortex motion and the small-scale turbulence generated in the break-down of the instabilities. Results indicate that diffusion on the order of 10{sup 9} m{sup 2}/s could possibly be generated by KHI on the flanks of the magnetosphere.

58 GEOSCIENCES↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Accurate Visual Heading Estimation at High Rotation Rate Without Oculomotor or Static-Depth Cues

It has been claimed that either oculomotor or static depth cues provide the signals about self-rotation necessary approx.-1 deg/s. We tested this hypothesis by simulating self-motion along a curved path with the eyes fixed in the head (plus or minus 16 deg/s of rotation). Curvilinear motion offers two advantages: 1) heading remains constant in retinotopic coordinates, and 2) there is no visual-oculomotor conflict (both actual and simulated eye position remain stationary). We simulated 400 ms of rotation combined with 16 m/s of translation at fixed angles with respect to gaze towards two vertical planes of random dots initially 12 and 24 m away, with a field of view of 45 degrees. Four subjects were asked to fixate a central cross and to respond whether they were translating to the left or right of straight-ahead gaze. From the psychometric curves, heading bias (mean) and precision (semi-interquartile) were derived. The mean bias over 2-5 runs was 3.0, 4.0, -2.0, -0.4 deg for the first author and three naive subjects, respectively (positive indicating towards the rotation direction). The mean precision was 2.0, 1.9, 3.1, 1.6 deg. respectively. The ability of observers to make relatively accurate and precise heading judgments, despite the large rotational flow component, refutes the view that extra-flow-field information is necessary for human visual heading estimation at high rotation rates. Our results support models that process combined translational/rotational flow to estimate heading, but should not be construed to suggest that other cues do not play an important role when they are available to the observer.

Stone, Leland S.↗

SU-D-BRE-01: A Realistic Breathing Phantom of the Thorax for Testing New Motion Mitigation Techniques with Scanning Proton Therapy

Purpose: A prototype breathing phantom (named LuCa) has been developed which simulates the anatomy and motion of a patient thorax.In this work, we describe the results of the first commissioning tests with LuCa. Methods: The phantom provides a close representation of the human thorax. The lungs,contained within a tissue-equivalent ribcage and skin,are made from a polymer foam,which is inflated and deflated using a custommade ventilator. A tumor is simulated using a wooden ball with cutplanes for placing GafChromic films. The ventilator,controlled with Labview software,simulates a full range of breathing motion types.Commissioning tests were performed to assess its performance using imaging (CT and radiographic) and film dosimetry as follows:i)maximum Tumor excursion at acceptable pressure ranges, ii)tumor Motion repeatability between breathing periods,iii)reproducibility between measurement days,iv)tumor-to-surface motion correlation and v)reproducibility of film positioning in phantom. Results: The phantom can generate repeatable motion patterns with sin{sup 4},sin,breath-hold (tumor amplitude repeatability <0.5mm over 10min),aswell as patient-specific motion types. Maximum excursions of the tumor are 20mm and 14mm for the large and small tumor inserts respectively. Amplitude reproducibility (Coefficient of Variation) averaged at 16% for the workable pressure range over 2 months. Good correlation between tumor and surface motion was found with R{sup 2}=0.92. Reproducibility of film positioning within the thorax was within 0.9mm, and maximum 3° error from the coronal plane. Film measurements revealed that the film repositioning error yields relative errors in the mean dose over the planned target volume (PTV) of up to 2.5% and 4.5% for films at the center and on the edge of the PTV respectively. Conclusion: Commissioning tests have shown that the LuCa phantom can produce tumor motion with excellent repeatability. However,a poorer performance in reproducibility of tumor amplitude for a given peak pressure week-to-week. Film set-up reproducibility is adequate for detection of dosimetric errors resulting from motion of >3%. This work is funded by Swiss National Fund Grants 320030-127569 and 320030-1493942-1.

60 APPLIED LIFE SCIENCES↗