Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Development of a Fast and Accurate PCRTM Radiative Transfer Model in the Solar Spectral Region

A fast and accurate principal component-based radiative transfer model in the solar spectral region (PCRTMSOLAR) has been developed. The algorithm is capable of simulating reflected solar spectra in both clear sky and cloudy atmospheric conditions. Multiple scattering of the solar beam by the multilayer clouds and aerosols are calculated using a discrete ordinate radiative transfer scheme. The PCRTM-SOLAR model can be trained to simulate top-of-atmosphere radiance or reflectance spectra with spectral resolution ranging from 1 cm(exp −1) resolution to a few nanometers. Broadband radiances or reflectance can also be calculated if desired. The current version of the PCRTM-SOLAR covers a spectral range from 300 to 2500 nm. The model is valid for solar zenith angles ranging from 0 to 80 deg, the instrument view zenith angles ranging from 0 to 70 deg, and the relative azimuthal angles ranging from 0 to 360 deg. Depending on the number of spectral channels, the speed of the current version of PCRTM-SOLAR is a few hundred to over one thousand times faster than the medium speed correlated-k option MODTRAN5. The absolute RMS error in channel radiance is smaller than 10(exp −3) mW∕cm)exp 2)∕sr∕cm(exp −1) and the relative error is typically less than 0.2%.

Liu, Xu↗

A Coordinated Mineralogical and Oxygen Isotopic Study of Refractory Ca-Al-Rich Inclusions

Refractory Ca-Al-rich inclusions (CAIs) in primitive chondritic meteorites represent the oldest solids that formed in our Solar System. Coordinated analyses using multiple ion and electron-beam techniques are vital to fully understand complex nebular and asteroidal processes that CAIs may have experienced in the context of the formation and early evolution of our Solar System. We report the results of a coordinated mineralogical and oxygen isotopic study of unique grossite bearing CAIs from reduced CV (Vigarano type) carbonaceous chondrites using transmission electron microscopy and secondary ion mass spectrometry. Grossite (CaAl 4 O 7 ) occurs in cores of nodules in fine grained CAIs that likely represent aggregates of nebular condensates. In many occurrences, grossite has been partially replaced by hercynite [(Fe,Mg,Zn)Al 2 O 4 ], which displays complex microstructures and compositions, and magnetite nanoparticles. This grossite alteration likely occurred via crystallographically controlled metasomatic reactions with Zn, Fe-rich aqueous fluids on the parent asteroid. The constituent phases of grossite bearing CAIs show heterogeneous oxygen isotopic compositions . That is, grossite and perovskite are 16 O poor and melilite is variably 16 O-depleted in contrast to solar like, 16 O-rich hibonite and spinel. The observed oxygen isotopic distribution is interpreted as a result of mineralogically controlled oxygen isotopic exchange with an 16 O-poor fluid on the parent asteroid. Collectively, we conclude that the presence of limited fluids played an important role in preferential alteration of grossite to hercynite and magnetite and various degrees of 16 O depletion in grossite, perovskite, and melilite during thermal metamorphism on the CV chondrite parent asteroid.

Jangmi Han↗

Tunable X-ray source

A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

07 ISOTOPE AND RADIATION SOURCES↗

Aerosol mass spectrometry systems and methods

A system according to one embodiment includes a particle accelerator that directs a succession of polydisperse aerosol particles along a predetermined particle path; multiple tracking lasers for generating beams of light across the particle path; an optical detector positioned adjacent the particle path for detecting impingement of the beams of light on individual particles; a desorption laser for generating a beam of desorbing light across the particle path about coaxial with a beam of light produced by one of the tracking lasers; and a controller, responsive to detection of a signal produced by the optical detector, that controls the desorption laser to generate the beam of desorbing light. Additional systems and methods are also disclosed.

47 OTHER INSTRUMENTATION↗

Event Reconstruction in the NOvA Experiment

The NOvA experiment observes oscillations in two channels (electron-neutrino appearance and muon-neutrino disappearance) using a predominantly muon-neutrino NuMI beam. The Near Detector records multiple overlapping neutrino interactions in each event and the Far Detector has a large background of cosmic rays due to being located on the surface. The oscillation analyses rely on the accurate reconstruction of neutrino interactions in order to precisely measure the neutrino energy and identify the neutrino flavor and interaction mode. Similarly, measurements of neutrino cross sections using the Near Detector require accurate identification of the particle content of each interaction. A series of pattern recognition techniques have been developed to split event records into individual spatially and temporally separated interactions, to estimate the interaction vertex, and to isolate and classify individual particles within the event. This combination of methods to achieve full event reconstruction in the NOvA detectors has discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated transmission electron microscope

An integrated transmission electron microscope comprising multiple electron sources for tuned beams of ultrafast, scanning probe, and parallel illumination in varied beam energies can be alternated within sub-microseconds onto a sample with dynamic ‘transient state’ processes to acquire atomic-scale structural/chemical data with site specificity. The various electron sources and condenser optics enable high-resolution imaging, high-temporal resolution imaging, and chemical imaging, using fast-switching magnets to direct the different electron beams onto a single maneuverable objective pole piece where the sample resides. Such multimodal in situ characterization tools housed in a single microscope have the potential to revolutionize materials science.

Jungjohann, Katherine L.↗

Differential holography

Differential Holography technology measures the amplitude and/or phase of, e.g., an incident linearly polarized spatially coherent quasi-monochromatic optical field by optically computing the first derivative of the field and linearly mapping it to an irradiance signal detectable by an image sensor. This information recorded on the image sensor is then recovered by a simple algorithm. In some embodiments, an input field is split into two or more beams to independently compute the horizontal and vertical derivatives (using amplitude gradient filters in orthogonal orientations) for detection on one image sensor in separate regions of interest (ROIs) or on multiple image sensors. A third unfiltered beam recorded in a third ROI directly measures amplitude variations in the input field to numerically remove its contribution as noise before recovering the original wavefront using a numerical in algorithm. When combined, the measured amplitude and phase constitute a holographic recording of the incident optical field.

Ravizza, Frank↗

Advanced Bent Crystal Collimation Studies at the Tevatron (T-980)

The T-980 bent crystal collimation experiment at the Tevatron has recently acquired substantial enhancements. First, two new crystals - a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal manufactured and characterized by the PNPI group. Second, a two plane telescope with 3 high-resolution pixel detectors per plane along with corresponding mechanics, electronics, control and software has been manufactured, tested and installed in the E0 crystal region. The purpose of the pixel telescope is to measure and image channeled (CH), volume-reflected (VR) and multiple volume-reflected (MVR) beam profiles produced by bent crystals. Third, an ORIGIN-based system has been developed for thorough analysis of experimental and simulation data. Results of analysis are presented for different types of crystals used from 2005 to present for channeling and volume reflection including pioneering tests of two-plane crystal collimation at the collider, all in comparison with detailed simulations.

43 PARTICLE ACCELERATORS↗

InAs Terahertz Metalens Emitter for Focused Terahertz Beam Generation

Metasurfaces have opened doors to combining multiple photonic functionalities in a single compact device. In particular, the ability to generate short terahertz (THz) pulses with precise wavefront engineering in a single THz metasurface redefined the role metasurfaces can play in THz systems. Here, an InAs metalens emitter which generates and focuses a THz pulse beam is demonstrated using a 130 nm thick InAs metasurface designed as a binary‐phase Fresnel zone plate. The THz beam is focused to a spot of ≈430 μm at 1 THz with a short focal length of 5 mm and large numerical aperture of 0.5. Nanoscale InAs Mie resonators comprising the metasurface enable THz generation with an amplitude as high as 20 times compared to plasmonic THz emitters and several times compared to a 1 mm thick ZnTe crystal. This InAs metasurface emitter provides a new paradigm for designing THz imaging, spectroscopy, and communication systems, where THz beam generation and shaping are performed with a single device without compromising the generation efficiency, while eliminating losses and avoiding limitations of phase matching of conventional nonlinear optics approaches.

47 OTHER INSTRUMENTATION↗

A study of the short- to long-phantom dose ratios for CT scanning without table translation

Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm{sup 3} Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-beam Phased Array Antennas

Many of NASA's future missions require multiple accesses to work together as a single system. To accomplish these missions, multi-beam phased array antennas are required to communicate between satellites flying in fixed formation. In this paper, a comparison of different multi-beam systems will be given followed by detailed discussions of the lens array architecture and test results.

Lee, R. Q.↗

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of Multiple Volume Reflection of Ultrarelativistic Protons by a Sequence of Several Bent Silicon Crystals

The interactions of 400 GeV protons with different sequences of bent silicon crystals have been investigated at the H8 beam line of the CERN Super Proton Synchrotron. The multiple volume reflection of the proton beam has been studied in detail on a five-crystal reflector measuring an angular beam deflection {theta}=52.96{+-}0.14 {mu}rad. The efficiency was found larger than 80% for an angular acceptance at the reflector entrance of 70 {mu}rad, with a maximal efficiency value of {epsilon}=0.90{+-}0.01{+-}0.03.

43 PARTICLE ACCELERATORS↗

Large area direct-write focused ion-beam lithography with dual-beam microscope.

The authors have investigated the performance of focused ion-beam (FIB) direct-write lithography for large area (multiple write-field) patterning in an FEI Nova Nanolab 600 dual-beam microscope. Their system is configured with a 100 nm resolution X-Y stage and a RAITH ELPHY LITHOGRAPHY control interface, with its own integrated 16 bit DAC pattern generator and software. Key issues with regard to configuration, process parameters, and procedures have been addressed. Characterization of stitching errors, pattern repeatability, and drift were performed. Offset lithography (multiple exposures with offset write fields) and in-field registration marks were evaluated for correcting stitching errors, and a test microfluidic device covering an area of 1 x 1.4 mm{sup 2} was successfully fabricated. The authors found that by using a combination of offset lithography and in-field registration mark correction methods, the stitching errors can be kept well below 100 nm. They also found that due to higher beam deflection speed provided by the electrostatic scanning in FIB systems versus the wide-spread electron-beam systems with electromagnetic scanning, FIB lithography can be just as fast as electron-beam lithography for typical mill depths down to about 200-500 nm (material dependent). This opens the door for a large suite of applications for materials where pattern transfer is difficult or impossible by reactive methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WE-A-207-00: In Memoriam of Jacques Ovadia - Reinvigorating Scientific Excellence: Electron Beam Therapy - Past, Present and Future

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

WE-A-207-01: Memorial Lecturer

The Medical Physics community lost one of its early pioneers in radiation oncology physics, Jacques Ovadia, who passed away in April of 2014 at the age of 90. Jacques received his Ph.D. in Nuclear Physics from the University of Illinois at Urbana in 1951. Subsequently, under the guidance of John Laughlin, he was introduced to the field of Medical Physics. When John moved to Memorial Sloan Kettering, Jacques followed him. There he gained clinical experience and expertise in the then cutting-edge field of high energy electron beam therapy. In 1956, Jacques joined Dr. Erich Uhlmann at Michael Reese Hospital in Chicago where one of the country’s first high energy medical linear accelerators had just been installed. During his 35 year tenure, Dr. Ovadia built a strong Medical Physics department that merged in 1984 with that of the University of Chicago. Jacques pioneered the use of high energy electron beams to treat deep seated tumors, multiple-field chest wall irradiation with variable electron energies, and even anticipated the current interest in high energy electron beam grid-therapy. At an early stage, he introduced a simulator, computerized treatment planning and in-house developed record and verify software. He retired in 1990 as Professor emeritus in Radiation and Cellular Biology at the University of Chicago. Dr. Ovadia was an early and strong supporter of AAPM. He was present at the Chicago ROMPS meeting where the decision was made to form an independent professional society for medical physics. He served as AAPM president in 1976. Jacques Ovadia is survived by his wife of 58 years, Florence, their daughter Corinne Graefe and son Marc Ovadia, MD, as well as four grandchildren and one great-grandchild. Jacques’ dynamic and ever enthusiastic personality inspired all who collaborated with him. He will be greatly missed.

60 APPLIED LIFE SCIENCES↗

Multibeam field emission x-ray system with half-scan reconstruction algorithm

Purpose: In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. Methods: The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a corresponding detector segment, and a sample rotation stage. The collimator is placed between the source and the object to restrict the x-ray radiations through the target object only. In this design, all the x-ray beams are activated simultaneously to provide multiple projection views of the object. The detector is virtually segmented and synchronized with the x-ray exposure and the physiological signals when gating is involved. The transmitted x-ray intensity from each beam is collected by the corresponding segment on the detector. After each exposure, the object is rotated by a step angle until sufficient data set is collected. The half-scan reconstruction formula for MBFEX system is derived from the conventional filtered backprojection algorithm. To demonstrate the advantages of the system and method in reducing motion artifacts, the authors performed simulations with both standard and dynamic Shepp-Logan phantoms. Results: The numerical results indicate that the proposed multibeam system and the associated half-scan algorithm can effectively reduce the scanning time and improve the image quality for a time-varying object. Conclusions: The MBFEX technique offers an opportunity for the innovation of multisource imaging system.

60 APPLIED LIFE SCIENCES↗

Channeling through Bent Crystals

Bent crystals have demonstrated potential for use in beam collimation. A process called channeling is when accelerated particle beams are trapped by the nuclear potentials in the atomic planes within a crystal lattice. If the crystal is bent then the particles can follow the bending angle of the crystal. There are several different effects that are observed when particles travel through a bent crystal including dechanneling, volume capture, volume reflection and channeling. With a crystal placed at the edge of a particle beam, part of the fringe of the beam can be deflected away towards a detector or beam dump, thus helping collimate the beam. There is currently FORTRAN code by Igor Yazynin that has been used to model the passage of particles through a bent crystal. Using this code, the effects mentioned were explored for beam energy that would be seen at the Facility for Advanced Accelerator Experimental Tests (FACET) at a range of crystal orientations with respect to the incoming beam. After propagating 5 meters in vacuum space past the crystal the channeled particles were observed to separate from most of the beam with some noise due to dechanneled particles. Progressively smaller bending radii, with corresponding shorter crystal lengths, were compared and it was seen that multiple scattering decreases with the length of the crystal therefore allowing for cleaner detection of the channeled particles. The input beam was then modified and only a portion of the beam sent through the crystal. With the majority of the beam not affected by the crystal, most particles were not deflected and after propagation the channeled particles were seen to be deflected approximately 5mm. After a portion of the beam travels through the crystal, the entire beam was then sent through a quadrupole magnet, which increased the separation of the channeled particles from the remainder of the beam to a distance of around 20mm. A different code, which was developed at SLAC, was used to create an angular profile plot which was compared to what was produced by Yazynin's code for a beam with no multiple scattering. The results were comparable, with volume reflection and channeling effects observed and the range of crystal orientations at which volume reflection is seen was about 1 mrad in both simulations.

43 PARTICLE ACCELERATORS↗