Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple regression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Polymers for Extreme Conditions Designed Using Syntax-Directed Variational Autoencoders

We report the design/discovery of new materials is highly nontrivial owing to the near-infinite possibilities of material candidates and multiple required property/performance objectives. Thus, machine learning tools are now commonly employed to virtually screen material candidates with desired properties by learning a theoretical mapping from material-to-property space, referred to as the forward problem. However, this approach is inefficient and severely constrained by the candidates that the human imagination can conceive. Thus, in this work on polymers, we tackle the materials discovery challenge by solving the inverse problem: directly generating candidates that satisfy desired property/performance objectives. We utilize syntax-directed variational autoencoders (VAE) in tandem with Gaussian process regression (GPR) models to discover polymers expected to be robust under three extreme conditions: (1) high temperatures, (2) high electric field, and (3) high temperature and high electric field, useful for critical structural, electrical, and energy storage applications. This approach to learn from and augment) human ingenuity is general and can be extended to discover polymers with other targeted properties and performance measures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental validation of a coupled neutron-photon inverse radiation transport solver.

Forward radiation transport is the problem of calculating the radiation field given a description of the radiation source and transport medium. In contrast, inverse transport is the problem of inferring the configuration of the radiation source and transport medium from measurements of the radiation field. As such, the identification and characterization of special nuclear materials (SNM) is a problem of inverse radiation transport, and numerous techniques to solve this problem have been previously developed. The authors have developed a solver based on nonlinear regression applied to deterministic coupled neutron-photon transport calculations. The subject of this paper is the experimental validation of that solver. This paper describes a series of experiments conducted with a 4.5-kg sphere of alpha-phase, weapons-grade plutonium. The source was measured in six different configurations: bare, and reflected by high-density polyethylene (HDPE) spherical shells with total thicknesses of 1.27, 2.54, 3.81, 7.62, and 15.24 cm. Neutron and photon emissions from the source were measured using three instruments: a gross neutron counter, a portable neutron multiplicity counter, and a high-resolution gamma spectrometer. These measurements were used as input to the inverse radiation transport solver to characterize the solver's ability to correctly infer the configuration of the source from its measured signatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian learning of orthogonal embeddings for multi-fidelity Gaussian Processes

Uncertainty propagation in complex engineering systems often poses significant computational challenges related to modeling and quantifying probability distributions of model outputs, as those emerge as the result of various sources of uncertainty that are inherent in the system under investigation. Gaussian Processes regression (GPs) is a robust meta-modeling technique that allows for fast model prediction and exploration of response surfaces. Multi-fidelity variations of GPs further leverage information from cheap and low fidelity model simulations in order to improve their predictive performance on the high fidelity model. In order to cope with the high volume of data required to train GPs in high dimensional design spaces, a common practice is to introduce latent design variables that are typically projections of the original input space to a lower dimensional subspace, and therefore substitute the problem of learning the initial high dimensional mapping, with that of training a GP on a low dimensional space. Here in this paper, we present a Bayesian approach to identify optimal transformations that map the input points to low dimensional latent variables. The \projection" mapping consists of an orthonormal matrix that is considered a priori unknown and needs to be inferred jointly with the GP parameters, conditioned on the available training data. The proposed Bayesian inference scheme relies on a two-step iterative algorithm that samples from the marginal posteriors of the GP parameters and the projection matrix respectively, both using Markov Chain Monte Carlo (MCMC) sampling. In order to take into account the orthogonality constraints imposed on the orthonormal projection matrix, a Geodesic Monte Carlo sampling algorithm is employed, that is suitable for exploiting probability measures on manifolds. We extend the proposed framework to multi-fidelity models using GPs including the scenarios of training multiple outputs together. We validate our framework on three synthetic problems with a known lower-dimensional subspace. The benefits of our proposed framework, are illustrated on the computationally challenging aerodynamic optimization of a last-stage blade for an industrial gas turbine, where we study the effect of an 85-dimensional shape parameterization of a three-dimensional airfoil on two output quantities of interest, specifically on the aerodynamic efficiency and the degree of reaction

42 ENGINEERING↗

WE-G-BRD-05: Is “New Radiobiology” Needed to Account for the Anti-Tumor Efficacy of Hypofractionated Lung SBRT?

Purpose: The radiobiological understanding of SBRT is controversial. In this work, we modeled SBRT outcomes based on a previously published tumor control probability model, that incorporates hypoxia, proliferation and cell-cycle effects, in order to understand if non-traditional factors must be invoked to understand the efficacy of single and multiple fraction SBRT. Methods: We extracted cohorts from Mehta et al. (PRO (2012) 2:288) with easily identifiable fractionation parameters and commensurate outcome and prescription methods (n=2617). Each RT scheme was simulated in the model, and the surviving fraction (SF) of tumor cells was estimated. Another simulation was then carried out with conventional (2Gy/fx, 5fx/wk) fractionation until the same SF was achieved, resulting in model-derived equivalent dose in 2Gy/fx for α/β=10 (EQD2{sub 10}(model)). In the scatter plot of the outcome vs. EQD2{sub 10}(model), logistic regressions were performed for the total group or separate groups (conventional RT, SBRT with 3×10 fxs, and single fx SBRT), assuming the slope of the dose response curve (γ{sub 50}) of 1.5. Chi-squared tests were performed to test the validity of the fit. Results: With unfavorable hypoxic and cell-cycle effects, the effectiveness of typical SBRT regimes were predicted by the model to be significantly less effective than comparable standard fractionation regimes. The single-fraction TD{sub 50} was only 55% of the conventional fractionation TD{sub 50}, in units of EQD2{sub 10}(model). The dose response curves for the separate fractionation groups seems to represent the three different groups, with a high p-value for both SBRT groups. For the lower α/β of 3, the same patterns were observed with smaller differences among the groups. Conclusion: Based on classical radiobiology, the dose response relation of SBRT was evaluated and compared with conventional RT. Observed SBRT outcomes are inconsistent with classical radiobiology principles, suggesting the possible other effects, which increases as the fractional dose increases.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readings are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.

60 APPLIED LIFE SCIENCES↗

TU-G-204-06: Correlation Between Texture Analysis-Based Model Observer and Human Observer in Diagnosis of Ischemic Infarct in Non-Contrast Head CT of Adults

Purpose: To investigate the correlation between texture analysis-based model observer and human observer in the task of diagnosis of ischemic infarct in non-contrast head CT of adults. Methods: Non-contrast head CTs of five patients (2 M, 3 F; 58–83 y) with ischemic infarcts were retro-reconstructed using FBP and Adaptive Statistical Iterative Reconstruction (ASIR) of various levels (10–100%). Six neuro -radiologists reviewed each image and scored image quality for diagnosing acute infarcts by a 9-point Likert scale in a blinded test. These scores were averaged across the observers to produce the average human observer responses. The chief neuro-radiologist placed multiple ROIs over the infarcts. These ROIs were entered into a texture analysis software package. Forty-two features per image, including 11 GLRL, 5 GLCM, 4 GLGM, 9 Laws, and 13 2-D features, were computed and averaged over the images per dataset. The Fisher-coefficient (ratio of between-class variance to in-class variance) was calculated for each feature to identify the most discriminating features from each matrix that separate the different confidence scores most efficiently. The 15 features with the highest Fisher -coefficient were entered into linear multivariate regression for iterative modeling. Results: Multivariate regression analysis resulted in the best prediction model of the confidence scores after three iterations (df=11, F=11.7, p-value<0.0001). The model predicted scores and human observers were highly correlated (R=0.88, R-sq=0.77). The root-mean-square and maximal residual were 0.21 and 0.44, respectively. The residual scatter plot appeared random, symmetric, and unbiased. Conclusion: For diagnosis of ischemic infarct in non-contrast head CT in adults, the predicted image quality scores from texture analysis-based model observer was highly correlated with that of human observers for various noise levels. Texture-based model observer can characterize image quality of low contrast, subtle texture changes in addition to human observers.

60 APPLIED LIFE SCIENCES↗

Multiple Document Representations from News Alerts for Automated Bio-surveillance Event Detection

Due to globalization, geographic boundaries no longer serve as effective shields for the spread of infectious diseases. In order to aid bio-surveillance analysts in disease tracking, recent research has been devoted to developing information retrieval and analysis methods utilizing the vast corpora of publicly available documents on the internet. In this work, we present methods for the automated retrieval and classification of documents related to active public health events. We demonstrate classification performance on an auto-generated corpus, using recurrent neural network, TFIDF, and Naive Bayes log count ratio document representations. By jointly modeling the title and description of a document, we achieve 97% recall and 93.3% accuracy with our best performing bio-surveillance event classification model; logistic regression on the combined output from a pair of bidirectional recurrent neural networks.

language analysis, Biosurveillance, document class↗

Distant Metastases Following Permanent Interstitial Brachytherapy for Patients With Clinically Localized Prostate Cancer

Purpose: Recent publications have suggested high-risk patients undergoing radical prostatectomy have a lower risk of distant metastases and improved cause-specific survival (CSS) than patients receiving definitive external beam radiation therapy (XRT). To date, none of these studies has compared distant metastases and CSS in brachytherapy patients. In this study, we evaluate such parameters in a consecutive cohort of brachytherapy patients. Methods and Materials: From April 1995 to June 2007, 1,840 consecutive patients with clinically localized prostate cancer were treated with brachytherapy. Risk groups were stratified according to National Comprehensive Cancer Network ( (www.nccn.org)) guidelines. Subgroups of 658, 893, and 289 patients were assigned to low, intermediate, and high-risk categories. Median follow-up was 7.2 years. Along with brachytherapy implantation, 901 (49.0%) patients received supplemental XRT, and 670 (36.4%) patients received androgen deprivation therapy (median duration, 4 months). The mode of failure (biochemical, local, or distant) was determined for each patient for whom therapy failed. Cause of death was determined for each deceased patient. Multiple parameters were evaluated for impact on outcome. Results: For the entire cohort, metastases-free survival (MFS) and CSS at 12 years were 98.1% and 98.2%, respectively. When rates were stratified by low, intermediate, and high-risk groups, the 12-year MFS was 99.8%, 98.1%, and 93.8% (p < 0.001), respectively. CSS rates were 99.8%, 98.0%, and 95.3% (p < 0.001) for low, intermediate, and high-risk groups, respectively. Biochemical progression-free survival was 98.7%, 95.9% and 90.4% for low, intermediate, and high-risk patients, respectively (p < 0.001). In multivariate Cox-regression analysis, MFS was mostly closely related to Gleason score and year of treatment, whereas CSS was most closely associated with Gleason score. Conclusions: Excellent CSS and MFS rates are achievable with high-quality brachytherapy for low, intermediate, and high-risk patients. These results compare favorably to alternative treatment modalities. In particular, our MFS and CSS rates for high-risk patients appear superior to those of published radical prostatectomy series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ballistic limit regression analysis for Space Station Freedom meteoroid and space debris protection system

Relationships defining the ballistic limit of Space Station Freedom's (SSF) dual wall protection systems have been determined. These functions were regressed from empirical data found in Marshall Space Flight Center's (MSFC) Hypervelocity Impact Testing Summary (HITS) for the velocity range between three and seven kilometers per second. A stepwise linear least squares regression was used to determine the coefficients of several expressions that define a ballistic limit surface. Using statistical significance indicators and graphical comparisons to other limit curves, a final set of expressions is recommended for potential use in Probability of No Critical Flaw (PNCF) calculations for Space Station. The three equations listed below represent the mean curves for normal, 45 degree, and 65 degree obliquity ballistic limits, respectively, for a dual wall protection system consisting of a thin 6061-T6 aluminum bumper spaced 4.0 inches from a .125 inches thick 2219-T87 rear wall with multiple layer thermal insulation installed between the two walls. Normal obliquity is d(sub c) = 1.0514 v(exp 0.2983 t(sub 1)(exp 0.5228). Forty-five degree obliquity is d(sub c) = 0.8591 v(exp 0.0428) t(sub 1)(exp 0.2063). Sixty-five degree obliquity is d(sub c) = 0.2824 v(exp 0.1986) t(sub 1)(exp -0.3874). Plots of these curves are provided. A sensitivity study on the effects of using these new equations in the probability of no critical flaw analysis indicated a negligible increase in the performance of the dual wall protection system for SSF over the current baseline. The magnitude of the increase was 0.17 percent over 25 years on the MB-7 configuration run with the Bumper II program code.

Jolly, William H.↗

The Impact of Below Detection Limit Samples in (NPP) Decommissioning Residual Risk Assessment - 17033

There are some technical problems with finalizing regulations and standards that address nuclear power plant (NPP) decommissioning site soil analyses for license termination. It is difficult to know how to best include detection limit observations from site soil analysis, because typical soil collection data is reported above, at, and below the detection limit. In addition, multiple detection limits are required to adequately estimate the soil radionuclide concentrations. In the literature, researchers analyzing environmental data refer to below the detection limit observations as 'left-censored data'. Left-censored data are less than the detection limit of the instrument(s) that made the measurements. Conventional approaches to managing left-censored data either ignore or simply replace the detection limits with zero, a fraction of the detection limit, or the detection limit itself. However, these approaches are statistically biased and limited in their usefulness. The Kaplan-Meier method, robust regression on order statistics method, and maximum likelihood estimation method are proposed to estimate the left-censored data more precisely. The proposed methods are applied to data from a Monazite powder manufacturing plant and the Colorado School of Mines Research Institute. Summary statistics such as the sample mean, sample standard deviation, sample percentiles are calculated from each data set and are used in risk and volume estimation calculations. Previous environmental analyses, such as the exposure assessment, recognize the uncertainty issue that is addressed in this research using the Latin hypercube sampling approach. Next, probabilistic distributions of the input parameters are developed for the uncertainty analyses. Finally, a framework methodology depicting the decision-making process in the proposed method is presented. The framework defines the critical steps, the amount of radioactivity, types of distributions, censoring percentage, sample size, and number of detection limits; it also allows the user to select the appropriate approach based on their site-specific data and analyses. The goal of this research is to develop a more precise risk assessment, estimate of the volume of soil removal, examine potential cost savings. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating the role of green infrastructure features in post-disaster recovery – Case Study of Beaumont, Texas after tropical storm imelda

While green infrastructure (GI) can provide multiple environmental benefits, its role in post-disaster economic and social recovery remains relatively underexplored. This article investigates whether different characteristics of GI, such as size, shape, connectivity, and amenities, affect the resilience of local businesses following Tropical Storm Imelda in Beaumont, Texas. The study utilizes SafeGraph mobility data to analyze foot traffic patterns to local businesses before, during, and after the disaster. FRAGSTATS indices measure GI characteristics (e.g., area, shape index, fractal dimension, proximity) while park features such as sports facilities, playgrounds, water features, and accessibility are cataloged through manual observation. Ordinary Least Squares regression models assess the relationship between park characteristics and post-recovery business performance, controlling for demographic variables including income, race, and poverty levels. Results indicate that certain GI attributes significantly enhance business recovery. Points of interest within walking distance (0.5 miles) of parks demonstrated better post-recovery status compared to those beyond this range. Specifically, parks with larger areas (p < 0.01) and more complex shapes measured by fractal dimension index (p < 0.01) had the strongest positive impact on surrounding businesses' recovery. Interestingly, playgrounds showed a negative correlation with recovery (p < 0.05), likely due to flood damage rendering them unusable during the immediate recovery period. Social vulnerability factors, including higher poverty rates and minority populations, negatively affected recovery outcomes despite park proximity.

Economic resilience↗

Adapting Secure MultiParty Computation to Support Machine Learning in Radio Frequency Sensor Networks

In this project we developed and validated algorithms for privacy-preserving linear regression using a new variant of Secure Multiparty Computation (MPC) we call "Hybrid MPC" (hMPC). Our variant is intended to support low-power, unreliable networks of sensors with low-communication, fault-tolerant algorithms. In hMPC we do not share training data, even via secret sharing. Thus, agents are responsible for protecting their own local data. Only the machine learning (ML) model is protected with information-theoretic security guarantees against honest-but-curious agents. There are three primary advantages to this approach: (1) after setup, hMPC supports a communication-efficient matrix multiplication primitive, (2) organizations prevented by policy or technology from sharing any of their data can participate as agents in hMPC, and (3) large numbers of low-power agents can participate in hMPC. We have also created an open-source software library named "Cicada" to support hMPC applications with fault-tolerance. The fault-tolerance is important in our applications because the agents are vulnerable to failure or capture. We have demonstrated this capability at Sandia's Autonomy New Mexico laboratory through a simple machine-learning exercise with Raspberry Pi devices capturing and classifying images while flying on four drones.

42 ENGINEERING↗

FAIR Data and Interpretable AI Framework for Architectured Metamaterials (Final Report)

This research program established a transformative framework for the discovery and design of mechanical metamaterials, which are architected structures engineered to control physical phenomena like sound and vibration in ways natural materials cannot. To overcome the traditional reliance on trial-and-error, the project developed an interpretable Artificial Intelligence (AI) framework that moves beyond "black box" models to reveal the specific geometric patterns—such as "unit-cell templates"—that govern a material’s performance. A major breakthrough was the development of a hierarchical design method, which allows a single material to block vibrations across multiple frequency ranges simultaneously by layering patterns at different scales without them interfering with one another. This was further expanded to include irregular, graph-based designs that use spanning tree algorithms to ensure structural connectivity while allowing for customized, direction-dependent properties like stiffness and acoustic impedance. Beyond design, the project addressed the practicalities of real-world production by developing uncertainty quantification techniques that account for manufacturing defects and material variability, reducing the need for expensive physical testing by orders of magnitude. To speed up the discovery process, the team implemented Gaussian Process Regression and other surrogate models that provide accurate performance predictions at a fraction of the traditional computational cost. The AI-generated designs were successfully validated through fabrication of physical samples and wave propagation experiments, confirming their ability to accurately guide or reflect waves as predicted. By contributing these tools and high-quality FAIR benchmark datasets to the wider scientific community, this work provides a scalable foundation for advancing technologies in aerospace vibration control, medical imaging, and noise reduction.

36 MATERIALS SCIENCE↗

Impairment of Human Ocular Tracking with Low-Dose Alcohol

Previous studies have documented adverse effects of alcohol on oculomotor performance. For example, moderate-dose alcohol (yielding a Blood Alcohol Concentration or BAC of 0.04-0.1%) has been shown to decrease steady-state pursuit gain (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to increase saccade latency (Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to decrease peak saccadic velocity (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Roche & King, 2010, Psychopharmacology, 212(1): 33), and to increase the frequency of catch-up saccades (Moser et al., 1998, J Neurol, 245(8): 542). Here, we administered two doses of ethanol on different days, yielding moderate (0.06%) and low (0.02%) levels of initial BAC, to examine the effects on human ocular tracking over BACs ranging from 0.00 to 0.07%. Twelve subjects (8 females) participated in a 5-day study. Three days of at-home measurements of daily activity and sleep were monitored, followed by two laboratory days where, ~5 hours after awakening, we administered one of the two possible single doses of alcohol. Using a previously published paradigm (Liston & Stone, 2014, J Vis, 14(14): 12), we measured oculomotor performance multiple times throughout the day with three pre-dosing baseline runs and bi-hourly post-dosing test runs until the subject recorded a BAC of 0.00% for two hours. BAC was measured before each run using an Alco-Sensor IV breathalyzer (Intoximeters, Inc., St. Louis, MO). For each of the oculometric measures, for each subject, we computed the within-subject % deviation for each test run from their baseline averaged across their three pre-dosing runs. We then averaged the data across subjects in 0.01% BAC bins. Finally, we used linear regression to compute the slope and x-intercept (threshold) of the mean binned % deviation as a function of BAC. We found that pursuit initiation was impaired at very low BAC levels, with significant (p < 0.002) linear trends in latency (+1.3%/0.01%BAC) and initial acceleration (-4.6%/0.01%BAC) with extrapolated absolute thresholds at or below 0.01% BAC. We also found that steady-state tracking was impaired showing significant (p < 0.002) linear trends in gain (- 3.8%/0.01%BAC) and catch-up saccade amplitude (+9.1%/0.01%BAC), again with extrapolated absolute thresholds around 0.01% BAC. We also found a significant (p < 0.02) increase in pursuit direction noise (+9.8%/0.01%BAC) with an extrapolated absolute threshold below 0.01% BAC. Many aspects of ocular tracking are impaired in a dose-dependent manner beginning at a BAC level around 0.01%, with significant effects at levels lower than previously reported and up to 8-times lower than the legal limit for driving in most states.

human performance↗

Incorporating residential AC load control into ancillary service markets: Measurement and settlement

Many pre-existing air conditioner load control programs can provide valuable operational flexibility but have not been incorporated into electricity ancillary service markets or grid operations. Multiple demonstrations have shown that residential air conditioner (AC) response can deliver resources quickly and can provide contingency reserves. A key policy hurdle to be overcome before AC load control can be fully incorporated into markets is how to balance the accuracy, cost, and complexity of methods available for the settlement of load curtailment. Overcoming this hurdle requires a means for assessing the accuracy of shorter-term AC load control demand reduction estimation approaches in an unbiased manner. This paper applies such a method to compare the accuracy of approaches varying in cost and complexity ? including regression analysis, load matching and control group approaches ? using feeder data, household data and AC end-use data. We recommend a practical approach for settlement, relying on an annually updated set of tables, with pre-calculated reduction estimates. These tables allow users to look up the demand reduction per device based on daily maximum temperature, geographic region and hour of day, simplifying settlement and providing a solution to the policy problem presented in this paper.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tuning the magnetic properties of the CrMnFeCoNi Cantor alloy

Magnetic properties of more than 20 Cantor alloy samples of varying composition were investigated over a temperature range of 5 K to 300 K and in fields of up to 70 kOe using magnetometry and muon spin relaxation. Two transitions are identified: a spin-glass-like transition that appears between 55K and 190K, depending on composition, and a ferrimagnetic transition that occurs at approximately 43K in multiple samples with widely varying compositions. The magnetic signatures at 43K are remarkably insensitive to chemical composition. A modified Curie-Weiss model was used to fit the susceptibility data and to extract the net effective magnetic moment for each sample. The resulting values for the net effective moment were either diminished with increasing Cr or Mn concentrations or enhanced with decreasing Fe, Co, or Ni concentrations. Beyond a sufficiently large effective moment, the magnetic ground state transitions from ferrimagnetism to ferromagnetism. The effective magnetic moments, together with the corresponding compositions, are used in a global linear regression analysis to extract element-specific effective magnetic moments, which are compared to the values obtained by ab initio based density functional theory calculations. Finally, these moments provide the information necessary to controllably tune the magnetic properties of Cantor alloy variants.

36 MATERIALS SCIENCE↗

Estimating Mangrove Aboveground Biomass from Airborne LiDAR Data: a Case Study from the Zambezi River Delta

Mangroves are ecologically and economically important forested wetlands with the highest carbon (C) density of all terrestrial ecosystems. Because of their exceptionally large C stocks and importance as a coastal buffer, their protection and restoration has been proposed as an effective mitigation strategy for climate change. The inclusion of mangroves in mitigation strategies requires the quantification of C stocks (both above and belowground) and changes to accurately calculate emissions and sequestration. A growing number of countries are becoming interested in using mitigation initiatives, such as REDD+ (reducing emissions from deforestation and forest degradation), in these unique coastal forests. However, it is not yet clear how methods to measure C traditionally used for other ecosystems can be modified to estimate biomass in mangroves with the precision and accuracy needed for these initiatives. Airborne Lidar (ALS) data has often been proposed as the most accurate way for larger scale assessments but the application of ALS for coastal wetlands is scarce, primarily due to a lack of contemporaneous ALS and field measurements. Here, we evaluated the variability in field and Lidar-based estimates of aboveground biomass (AGB) through the combination of different local and regional allometric models and standardized height metrics that are comparable across spatial resolutions and sensor types, the end result being a simplified approach for accurately estimating mangrove AGB at large scales and determining the uncertainty by combining multiple allometric models.We then quantified wall-to-wall AGB stocks of a tall mangrove forest in the Zambezi Delta, Mozambique. Our results indicate that the Lidar H100 height metric correlates well with AGB estimates, with R(exp 2) between 0.80 and 0.88 and RMSE of 33% or less. When comparing Lidar H100 AGB derived from three allometric models, mean AGB values range from 192 Mg ha(exp −1) up to 252 Mg ha(exp −1).We suggest the best model to predict AGB was based on the East Africa specific allometry and a power-based regression that used Lidar H100 as the height input with an R(exp 2) of 0.85 and an RMSE of 122 Mg ha(exp −1) or 33%. The total AGB of the Lidar inventoried mangrove area (6654 ha) was 1 350 902 Mg with a mean AGB of 203 Mg ha(exp −1) +/-166 Mg ha(exp −1). Because the allometry suggested here was developed using standardized height metrics, it is recommended that the models can generate AGB estimates using other remote sensing instruments that are more readily accessible over other mangrove ecosystems on a large scale, and as part of future carbon monitoring efforts in mangroves.

Fatoyinbo, Temilola↗

Machine Learning Approaches for Predicting Radiation Therapy Outcomes: A Clinician's Perspective

Radiation oncology has always been deeply rooted in modeling, from the early days of isoeffect curves to the contemporary Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) initiative. In recent years, medical modeling for both prognostic and therapeutic purposes has exploded thanks to increasing availability of electronic data and genomics. One promising direction that medical modeling is moving toward is adopting the same machine learning methods used by companies such as Google and Facebook to combat disease. Broadly defined, machine learning is a branch of computer science that deals with making predictions from complex data through statistical models. These methods serve to uncover patterns in data and are actively used in areas such as speech recognition, handwriting recognition, face recognition, “spam” filtering (junk email), and targeted advertising. Although multiple radiation oncology research groups have shown the value of applied machine learning (ML), clinical adoption has been slow due to the high barrier to understanding these complex models by clinicians. Here, we present a review of the use of ML to predict radiation therapy outcomes from the clinician's point of view with the hope that it lowers the “barrier to entry” for those without formal training in ML. We begin by describing 7 principles that one should consider when evaluating (or creating) an ML model in radiation oncology. We next introduce 3 popular ML methods—logistic regression (LR), support vector machine (SVM), and artificial neural network (ANN)—and critique 3 seminal papers in the context of these principles. Although current studies are in exploratory stages, the overall methodology has progressively matured, and the field is ready for larger-scale further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗