Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Multi-fidelity information fusion and resource allocation

This project created and demonstrated a framework for the efficient and accurate prediction of complex systems with only a limited amount of highly trusted data. These next generation computational multi-fidelity tools fuse multiple information sources of varying cost and accuracy to reduce the computational and experimental resources needed for designing and assessing complex multi-physics/scale/component systems. These tools have already been used to substantially improve the computational efficiency of simulation aided modeling activities from assessing thermal battery performance to predicting material deformation. This report summarizes the work carried out during a two year LDRD project. Specifically we present our technical accomplishments; project outputs such as publications, presentations and professional leadership activities; and the project’s legacy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Strange Case of Ground-Coupled Airwaves on Seismoacoustic Stations at Local to Near-Regional Scales

Here we investigate the application of ground-coupled airwaves observed by seismoacoustic stations at local to near-regional scales to detect signals of interest and determine back-azimuth information. Ground-coupled airwaves are created from incident pressure waves traveling through the atmosphere that couple to the earth and transmit as a seismic wave with retrograde elliptical motion. Previous studies at sub-local scales (<10 km from a source of interest) found the back-azimuth to the source could be accurately determined from seismoacoustic signals recorded by acoustic and 3-component seismic sensors spatially separated on the order of 10 to 150 m. The potential back-azimuth directions are estimated from the coherent signals between the acoustic and vertical seismic data, via a propagation-induced phase shift of the seismoacoustic signal. A unique solution is then informed by the particle motion of the 3-component seismic station, which was previously found to be less accurate than the seismoacoustic-sensor method. We investigate the applicability of this technique to greater source-receiver distances, from 50-100 km and up to 400 km, which contains pressure waves with tropospheric and stratospheric ray paths, respectively. Specifically, we analyze seismoacoustic sources with ground truth from rocket motor fuel elimination events at the Utah Test and Training Range (UTTR) as well as a 2020 rocket launch in Southern California. From these sources we observe evidence that while coherent signals can be seen from both sources on multiple seismoacoustic station pairs, the determined ground-coupled airwave back-azimuths are more complicated than results at more local scales. Our findings suggest more complex factors including incidence angle, coupling location, subsurface material, and atmospheric propagation effects need to be fully investigated before the ground-coupled airwave back-azimuth determination method can be applied or assessed at these further distances.

58 GEOSCIENCES↗

Electrolyzers for Hydrogen Production: Solid Oxide, Alkaline, and Proton Exchange Membrane

The effects of climate change have led to a push for cleaner energy sources across multiple sectors. Hydrogen has emerged as a promising energy carrier in this context, as it can be produced using various water electrolysis technologies capable of utilizing clean power (e.g., nuclear and renewable electricity). However, a comprehensive environmental assessment of these technologies requires an understanding of the environmental impacts during their complete life cycle, including the embodied emissions in their material composition and during their manufacturing stages; these emissions are often neglected. This report provides a brief overview of major water electrolysis technologies, viz., proton exchange membrane electrolyzer cell (PEMEC) or polymer electrolyte membrane (PEM), alkaline electrolysis cell (AEC) and solid oxide electrolysis cell (SOEC), along with a detailed bill of materials for these technologies that has been incorporated in the updated G reenhouse gases, R egulated E missions, and E nergy use in T ransportation (GREET ® ) 2022 model. We also provide an inventory for the intermediate materials used to produce these electrolyzers, which has not been covered in prior releases. Using these material and energy flows, the GREET model provides a detailed life cycle inventory (energy use and emissions) from raw material extraction through complete production of electrolyzers for major electrolysis technologies.

08 HYDROGEN↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Full Integration of Lipidomics Data into Multi-OMIC Functional Enrichment

Lipids have numerous roles critical to living systems. Many of these vital functions are tightly linked or regulated by proteins. Even though the function of many lipid-related enzymes is known, direct links between most individual lipid species and the enzymes that metabolize them are severely lacking. This missing connection impedes biological progress. A resource that allows users to quickly identify protein-lipid relationships will advance our understanding of lipid homeostasis and metabolic perturbed systems. Databases are readily available for mapping small molecule metabolites (i.e., polar metabolites) and specific oxidized fatty acid lipids (e.g., arachidonic acid derivatives) to proteins/enzymes known to be directly involved in metabolism of these molecules (e.g. SMPDB, Reactome, HMDB, BioCyc). This enables the integration of metabolite and protein (as well as transcript) data when performing functional enrichment and metabolic modeling allowing researchers to rapidly examine metabolic pathways from multiple omics sources. Currently, linking lipidomics data with proteomics data is conducted using a time-intensive, user defined, manual process. Here we propose creating a tool that will link lipidomics and proteomics data and also conduct functional enrichment analysis and visualization allowing for full statistical integration. Using text-mining approaches, we will extract lipid references from uniprot and create a database linking lipid species to enzymes directly related to their metabolism. We will also extract directional annotation, which will allow even greater specificity when linking data types and will help eliminate false positives from functional associations.

59 BASIC BIOLOGICAL SCIENCES↗

DFTT report for Signal Analysis (2023)

The Detection Framework Testbed and Toolkit (DFTT) is a database and associated java programs intended to facilitate the development and testing of algorithms for operating suites of correlation and subspace detectors. This framework is a generalization of the system described in Harris and Dodge (2011) and Dodge and Harris (2016). DFTT allows retrospective processing of sequences of data using various system configurations. Results are saved in a database, so it is easy to compare the results obtained using different configurations of the system. The principal software components of DFTT are the ConfigCreator, the framework_runner and the Builder program. ConfigCreator assembles the files necessary to define a particular configuration used for processing. The framework_runner operates suites of detectors and saves the results in an Oracle™ database. Builder allows visual examination of templates and detected signals and allows editing and creation of detectors. In addition, there are tools for importing continuous data into the database. DFTT is licensed under the MIT license and has LLNL release number LLNL-CODE-801881. In the current fiscal year DFTT has been used in two different projects. The first (NTL-funded) project investigates the feasibility of screening nuisance detections using correlation detectors. The second (GNEM-funded) project seeks to extend the results of Harris and Dodge (2021) to 3- D sources and multiple stations. Each of these efforts required that additional functionality be added to DFTT. In this report I will summarize the enhancements to DFTT in the context of the relevant research effort.

58 GEOSCIENCES↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence in Nuclear Physics

Artificial Intelligence (AI) and Machine Learning (ML) are rapidly developing fields providing data-driven algorithms to predict, classify, and make decisions based on data. Nuclear Physics Research is data-driven and AI/ML techniques have been implemented for experiment and accelerator control, in theoretical applications, and in data processing and analysis. These algorithms open possibilities for automation, thereby augmenting human capabilities. Additionally, Open Science is enabled by simultaneous analyses of multiple data sources, leading to scientific knowledge. This talk will summarize current applications of AI/ML in nuclear physics, as well as accelerator applications, and will cover upcoming initiatives and research in AI/ML.

Jeske, Torri↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding Event Trajectories Across Massive Temporal Datasets with Word Embeddings and Visualization

In collaboration with researchers from Virginia Tech, Savannah River National Laboratory has continued development of a natural language processing pipeline to identify and extract events of interest from massive open data sources in the domain of worldwide state-sponsored civil nuclear energy. The foundation of the pipeline is built on compass aligned temporal word embedding models, whereby contextual shifts are automatically identified by comparing keyword embedding vectors across successive time windows. Within the approach, a contextual shift indicates the occurrence of a potential event of interest. However, in such a broad topical domain that captures events at a global scale, across various life cycle stages, and across numerous different technology types, a user that is monitoring events may have broad interests in capturing many different event types with varying degrees of signal. As such, the quantity of information that may be returned from an automated event extraction pipeline can be substantial, requiring manual effort to sift through the information to identify any relevant bits of information. Therefore, a more streamlined workflow that aids in directing a user toward specific information at different points in time is necessary. The workflow presented here has been developed with this concept in mind, built on top of the initial prototype event extraction pipeline, whereby a user can analyze temporal text-based data sources at multiple different contextual levels to isolate key points in time and key subdomains captured within a data corpus. Using multiple corpuses that consist of approximately 7 million Tweets and 7 million news articles, the team has extended compass aligned temporal word embedding models to establish an interconnected and hierarchical structure that relates known key words of interest to documents, local topics (i.e., within a time window), and global topics across the corpuses. All of this information is packaged into a visual analytics system that is linked to the information extraction pipeline and enables a user to identify contextual information that describes the evolution of a high dimensional embedding space across time to isolate changes of interest and explore associated events. This report demonstrates the use of these analytics and a means to fuse information across multiple datasets.

97 MATHEMATICS AND COMPUTING↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗