Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Ultrasensitive mode-localized mass sensor with electrically tunable parametric sensitivity

We use the phenomena of mode localization and vibration confinement in pairs of weakly coupled, nearly identical microelectromechanical (MEMS) resonators as an ultrasensitive technique of detecting added mass on the resonator. The variations in the eigenstates for induced mass additions are studied and compared with corresponding resonant frequency shifts in pairs of MEMS resonators that are coupled electrostatically. We demonstrate that the relative shifts in the eigenstates can be over three orders of magnitude greater than those in resonant frequency for the same addition of mass. We also investigate the effects of voltage controlled electrical spring tuning on the parametric sensitivity of such sensors and demonstrate sensitivities tunable by over 400%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening

We demonstrate an optically pumped {sup 87}Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the {sup 87}Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peristaltic pump-based low range pressure sensor calibration system

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Selective Single-Barium Ion Detection with Dry Diazacrown Ether Naphthalimide Turn-on Chemosensors

Single-molecule fluorescence imaging (SMFI) of gas-phase ions has been proposed for “barium tagging,” a burgeoning area of research in particle physics to detect individual barium daughter ions. This has potential to significantly enhance the sensitivity of searches for neutrinoless double-beta decay (0νββ) that is obscured by background radiation events. The chemistry required to make such sensitive detection of Ba 2+ by SMFI in dry Xe gas at solid interfaces has implications for solid-phase detection methods but has not been demonstrated. Here, we synthesized simple, robust, and effective Ba 2+ -selective chemosensors capable of function within ultrapure high-pressure 136 Xe gas. Turn-on fluorescent naphthalimide-(di)azacrown ether chemosensors were Ba 2+ -selective and achieved SMFI in a polyacrylamide matrix. Here, fluorescence and NMR experiments supported a photoinduced electron transfer mechanism for turn-on sensing. Ba 2+ selectivity was achieved with computational calculations correctly predicting the fluorescence responses of sensors to barium, mercury, and potassium ions. With these molecules, dry-phase single-Ba 2+ ion imaging with turn-on fluorescence was realized using an oil-free microscopy technique for the first time—a significant advance toward single-Ba 2+ ion detection within large volumes of 136 Xe, plausibly enabling a background-independent technique to search for the hypothetical process of 0νββ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dependence of the compensation error on the error of a sensor and corrector in an adaptive optics phase-conjugating system

In the framework of a statistical model of an adaptive optics system (AOS) of phase conjugation, three algorithms based on an integrated mathematical approach are considered, each of them intended for minimisation of one of the following characteristics: the sensor error (in the case of an ideal corrector), the corrector error (in the case of ideal measurements) and the compensation error (with regard to discreteness and measurement noises and to incompleteness of a system of response functions of the corrector actuators). Functional and statistical relationships between the algorithms are studied and a relation is derived to ensure calculation of the mean-square compensation error as a function of the errors of the sensor and corrector with an accuracy better than 10%. Because in adjusting the AOS parameters, it is reasonable to proceed from the equality of the sensor and corrector errors, in the case the Hartmann sensor is used as a wavefront sensor, the required number of actuators in the absence of the noise component in the sensor error turns out 1.5 – 2.5 times less than the number of counts, and that difference grows with increasing measurement noise. (adaptive optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable Neutron Sensors for Emergency Response Operations

This article presents the experimental work performed in the area of neutron detector development at the Remote Sensing Laboratory–Andrews Operations (RSL-AO) sponsored by the U.S. Department of Energy, National Nuclear Security Administration (NNSA) in the last four years. During the 1950s neutron detectors were developed mostly to characterize nuclear reactors where the neutron flux is high. Due to the indirect nature of neutron detection via interaction with other particles, neutron counting and neutron energy measurements have never been as precise as gamma-ray counting measurements and gamma-ray spectroscopy. This indirect nature is intrinsic to all neutron measurement endeavors (except perhaps for neutron spin-related experiments, viz. neutron spin-echo measurements where one obtains μeV energy resolution). In emergency response situations generally the count rates are low, and neutrons may be scattered around in inhomogeneous intervening materials. It is also true that neutron sensors are most efficient for the lowest energy neutrons, so it is not as easy to detect and count energetic neutrons. Most of the emergency response neutron detectors are offshoots of nuclear device diagnostics tools and special nuclear materials characterization equipment, because that is what is available commercially. These instruments mostly are laboratory equipment, and not field-deployable gear suited for mobile teams. Our goal is to design and prototype field-deployable, ruggedized, lightweight, efficient neutron detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗

Fiber Optic Instrumentation in High Temperature Irradiation Environments

The extremely harsh conditions of advanced reactor designs pose serious challenges for nuclear fuels and materials. Traditional instrumentation (thermocouples, strain gauges, etc.) are not well suited for extended operation in such a harsh environment. This work discusses the potential for using fiber optic-based instrumentation in high temperature irradiation experiments. The primary limitation of fiber optic instrumentation in irradiation experiments is signal darkening due to attenuation in the fiber material. A computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Preliminary results obtained using this model are shown for one cycle of irradiation in the high flux isotope reactor at various temperatures. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose in order to validate the predictive model. Demonstration of the safety and reliability of new and enhanced nuclear fuels and materials is essential for improving the safety and reliability of existing nuclear power plants and for the licensing and operation of advanced nuclear reactor technologies. Experimental validation of fuel performance codes requires high fidelity measurements during instrumented irradiation experiments. Therefore, a clear need exists for sensors of unprecedented accuracy, resolution, time/space/energy spectrum dependence, reduced size, and, perhaps most importantly, performance in harsh environments. The harsh environment during accelerated irradiation testing could include temperatures from 300 deg. C up to 2600 deg. C, and radiation damage levels ranging from 1 to greater than 100 dpa. Optical fiber-based sensors are a promising candidate for instrumentation in high temperature irradiation environments. Optical fibers are small, inexpensive, chemically inert, immune to electromagnetic interference, and made of high temperature radiation-hard materials. The ability to make distributed measurements of temperature or strain using a single inexpensive optical fiber currently exists for non-extreme environments as commercially available technology. Other advanced sensing technologies such as laser ultrasound, borescopes, and laser-induced breakdown spectroscopy use fiber optic light delivery as a critical component of the sensor design. Some potential applications for optical fiber-based sensors in instrumented irradiation experiments include in-situ measurements of thermal conductivity, ultrasonic measurement of elastic constants (with fiber optic delivery of signal for generation and detection of ultrasonic wave), and distributed measurements of temperature and/or strain (i.e., swelling). The primary limitation for the use of optical technologies for harsh environment (e.g., high neutron flux reactor environments) instrumentation is the attenuation of the light signal due to the effects of temperature and/or irradiation. This work summarizes initial efforts towards developing a predictive model of temperature-dependent radiation-induced attenuation in fused silica optical fibers at high dose. If there is adequate transmission in the fibers, fiber optic-based instrumentation could provide highly accurate distributed measurements during instrumented fuel/material irradiation experiments. Preliminary results show attenuation on the order of 5- 10 dB/m in the wavelength range of 750-900 nm at temperatures of 300 deg. C and below after one HFIR cycle (24 days). At higher temperatures (600 and 900 deg. C), the attenuation is reduced below 5 dB/m in the same wavelength range. This amount of attenuation is acceptable for most fiber optic based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high flux region. Many optical components use a wavelength of 850 nm, which lies in the low attenuation window. In order to refine and ultimately validate the predictive model of optical fiber attenuation, a reactor irradiation campaign has been initiated. Rabbit irradiation capsules have been designed to irradiate optical fiber material (low and high OH fused silica, as well as single crystal sapphire) specimens in the HFIR at temperatures ranging from 100 to 1200 deg. C. (authors)

42 ENGINEERING↗

Theory of signal and noise in double-gated nanoscale electronic pH sensors

The maximum sensitivity of classical nanowire (NW)-based pH sensors is defined by the Nernst limit of 59 mV/pH. For typical noise levels in ultra-small single-gated nanowire sensors, the signal-to-noise ratio is often not sufficient to resolve pH changes necessary for a broad range of applications. Recently, a new class of double-gated devices was demonstrated to offer apparent 'super-Nernstian' response (>59 mV/pH) by amplifying the original pH signal through innovative biasing schemes. However, the pH-sensitivity of these nanoscale devices as a function of biasing configurations, number of electrodes, and signal-to-noise ratio (SNR) remains poorly understood. Even the basic question such as 'Do double-gated sensors actually resolve smaller changes in pH compared to conventional single-gated sensors in the presence of various sources of noise?' remains unanswered. In this article, we provide a comprehensive numerical and analytical theory of signal and noise of double-gated pH sensors to conclude that, while the theoretical lower limit of pH-resolution does not improve for double-gated sensors, this new class of sensors does improve the (instrument-limited) pH resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of Surface Properties Pre-Rad and Post-Rad of n-in-p Silicon Sensors for Very High Radiation Environment

We are developing n{sup +}-in-p, p-bulk and n-readout, microstrip sensors as a non-inverting radiation hard silicon detector for the ATLAS Tracker Upgrade at the super LHC experiment. The surface radiation damages of the sensors fabricated by Hamamatsu Photonics are characterized on the interstrip capacitance, interstrip resistance and punch-through protection evolution. The detector should provide acceptable strip isolation, exceeding the input impedance of the signal readout chip {approx}1 k{Omega}, after the integrated luminosity of 6 ab{sup -1}, which is twice the luminosity goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inspection Tools for Hanford Tanks and Waste Transport Systems - 20444

Recent integrity issues in the double-shell tanks (DST) at Hanford have motivated the need for developing innovative tools that can provide information regarding the health of the tanks. These issues include the primary linear failure of AY-102 and recent concerns of thinning in the DST secondary liners. Other concerns include erosion or corrosion on transfer lines and processing pipes. In recent years, Florida International University (FIU) has supported DOE-EM by developing tools that can assist in understanding the health of tanks and waste transport system at Hanford. More specifically, FIU has developed a miniature rover that can be deployed through small risers and gain access to refractory slots in the Hanford DSTs. It traverses through the slots on the primary liner upside down via magnets to avoid debris in the slots. Recent modifications include a spring loaded magnetic arm that allows the unit to traverse over large weld seams but does not reduce the overall functionality of the system. The system has also incorporated a control capsule that will sit within the annulus of the tank and improves on issues related to signal and voltage loss over long tether lines. Lastly, the unit is also being augmented with a second module that will include a means to prep the tank surface and obtain a thickness measurement using a dual element ultrasonic sensor. FIU has also developed a 6-inch peristaltic pipe crawler that operates similar to the previous pipe crawlers developed at FIU. This crawler is a marsupial type crawler that will navigate through the 6-inch drain lines, and deploy a small rover at the entrance of the drain slots. This rover will also traverse upside down on the secondary liner and provide information regarding the health of the liner. An initial prototype for the crawler unit has been developed, assembled and tested. The system is pneumatic and consists of three modules - two grippers and one extender. The validation tests are conducted in a mockup of the drain lines and demonstrate the system's ability to navigate through long pipe lengths and elbows. In this paper, a general overview of each of the aforementioned systems is presented along with results from testing and demonstrations that shows the applicability of each system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-Management of Patient Body Position, Pose, and Motion Using Wide-Field, Real-Time Optical Measurement Feedback: Results of a Volunteer Study

Purpose: We present the results of a clinical feasibility study, performed in 10 healthy volunteers undergoing a simulated treatment over 3 sessions, to investigate the use of a wide-field visual feedback technique intended to help patients control their pose while reducing motion during radiation therapy treatment. Methods and Materials: An optical surface sensor is used to capture wide-area measurements of a subject's body surface with visualizations of these data displayed back to them in real time. In this study we hypothesize that this active feedback mechanism will enable patients to control their motion and help them maintain their setup pose and position. A capability hierarchy of 3 different level-of-detail abstractions of the measured surface data is systematically compared. Results: Use of the device enabled volunteers to increase their conformance to a reference surface, as measured by decreased variability across their body surfaces. The use of visual feedback also enabled volunteers to reduce their respiratory motion amplitude to 1.7 ± 0.6 mm compared with 2.7 ± 1.4 mm without visual feedback. Conclusions: The use of live feedback of their optically measured body surfaces enabled a set of volunteers to better manage their pose and motion when compared with free breathing. The method is suitable to be taken forward to patient studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PSF and MTF Measurement Methods for Thick CCD Sensor Characterization

Knowledge of the point spread function (PSF) of the sensors to be used in the Large Synoptic Survey Telescope (LSST) camera is essential for optimal extraction of subtle galaxy shape distortions caused by gravitational weak lensing. We have developed a number of techniques for measuring the PSF of candidate CCD sensors to be used in the LSST camera, each with its own strengths and weaknesses. The two main optical PSF measurement techniques that we use are the direct Virtual Knife Edge (VKE) scan as developed by Karcher, et al. and the indirect interference fringe method after Andersen and Sorensen that measures the modulation transfer function (MTF) directly. The PSF is derived from the MTF by Fourier transform. Other non-optical PSF measurement techniques that we employ include {sup 55}Fe x-ray cluster image size measurements and statistical distribution analysis, and cosmic ray muon track size measurements, but are not addressed here. The VKE technique utilizes a diffraction-limited spot produced by a Point-Projection Microscope (PPM) that is scanned across the sensor with sub-pixel resolution. This technique closely simulates the actual operating condition of the sensor in the telescope with the source spot size having an f/number close to the actual telescope design value. The interference fringe method uses a simple equal-optical-path Michelson-type interferometer with a single-mode fiber source that produces interference fringes with 100% contrast over a wide spatial frequency range sufficient to measure the MTF of the sensor directly. The merits of each measurement technique and results from the various measurement techniques on prototype LSST sensors are presented and compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of In-Sodium Hydrogen Sensor

The goal of this project is to demonstrate diffusion-type in-sodium hydrogen meters (ISHMs) for real-time, in-situ monitoring of hydrogen concentration in molten sodium of a sodium-cooled fast reactor (SFR). The FY22 R&D efforts have been focused on (a) enhancement and fabrication of meshed ISHM prototype, (b) reconstruction of ISHM sodium test apparatus, (c) in-sodium test of meshed ISHM, and (d) ISHM performance and failure evaluations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗