Manufacturing Precise, Lightweight Paraboloidal Mirrors

A process for fabricating a precise, diffraction- limited, ultra-lightweight, composite- material (matrix/fiber) paraboloidal telescope mirror has been devised. Unlike the traditional process of fabrication of heavier glass-based mirrors, this process involves a minimum of manual steps and subjective judgment. Instead, this process involves objectively controllable, repeatable steps; hence, this process is better suited for mass production. Other processes that have been investigated for fabrication of precise composite-material lightweight mirrors have resulted in print-through of fiber patterns onto reflecting surfaces, and have not provided adequate structural support for maintenance of stable, diffraction-limited surface figures. In contrast, this process does not result in print-through of the fiber pattern onto the reflecting surface and does provide a lightweight, rigid structure capable of maintaining a diffraction-limited surface figure in the face of changing temperature, humidity, and air pressure. The process consists mainly of the following steps: 1. A precise glass mandrel is fabricated by conventional optical grinding and polishing. 2. The mandrel is coated with a release agent and covered with layers of a carbon- fiber composite material. 3. The outer surface of the outer layer of the carbon-fiber composite material is coated with a surfactant chosen to provide for the proper flow of an epoxy resin to be applied subsequently. 4. The mandrel as thus covered is mounted on a temperature-controlled spin table. 5. The table is heated to a suitable temperature and spun at a suitable speed as the epoxy resin is poured onto the coated carbon-fiber composite material. 6. The surface figure of the optic is monitored and adjusted by use of traditional Ronchi, Focault, and interferometric optical measurement techniques while the speed of rotation and the temperature are adjusted to obtain the desired figure. The proper selection of surfactant, speed or rotation, viscosity of the epoxy, and temperature make it possible to obtain the desired diffraction-limited, smooth (1/50th wave) parabolic outer surface, suitable for reflective coating. 7. A reflective coat is applied by use of conventional coating techniques. 8. Once the final figure is set, a lightweight structural foam is applied to the rear of the optic to ensure stability of the figure.

Hermann, Frederick Thomas↗

Assessment of Buffet Forcing Function Development Process Using Unsteady Pressure Sensitive Paint

A wind tunnel test was conducted at the Ames Unitary Plan Wind Tunnel to characterize the transonic buffet environment of a generic launch vehicle forebody. The test examined a highly instrumented version of the Coe and Nute Model 11 test article first tested in the 1960s. One of the measurement techniques used during this test was unsteady pressure sensitive paint (uPSP) developed at the Arnold Engineering Development Complex. This optical measurement technique measured fluctuating pressures at over 300,000 locations on the surface of the model. The high spatial density of these measurements provided an opportunity to examine in depth the assumptions underpinning the development of buffet forcing functions (BFFs) used in the development of the Space Launch System vehicle. The comparison of discrete-measurement-based BFFs to BFFs developed by continuous surface pressure integration indicates that the current BFF development approach under predicts low frequency content of the BFFs while over predicting high frequency content. Coherence-based adjustments employed to reduce over prediction in the surface integration of discrete pressure measurements contribute to the inaccuracy of the BFFs and their implementation should be reevaluated.

Sekula, Martin K.↗

Determining Aerodynamic Loads Based on Optical Deformation Measurements

This paper describes a videogram metric technique for determining aerodynamic loads based on optical elastic deformation measurements. The data reduction methods are developed to extract the normal force and pitching moment from beam deformation data. The axial force is obtained by measuring the axial translational motion of a movable shaft in a spring/bearing device. Proof-of-concept calibration experiments are conducted to assess the accuracy of this optical technique.

Liu, Tianshu↗

Liquidus temperature and optical properties measurement by containerless techniques

Reactive alloy liquidus temperatures measured by conventional, contained techniques are often in error due to reactions with containers and gaseous impurities. This paper describes a new liquidus temperature measurement technique that avoids these problems by employing containerless processing. This technique relies on precise and accurate noncontact temperature measurements (NCTM), which are made possible by spectral emissivity values. The spectral emissivities, epsilon(sub lambda), are measured along with the optical properties (real, n, and imaginary, k, components of the index of refraction) using polarimetric techniques on electromagnetically levitated specimens. Results from work done at Vanderbilt University and Intersonics on the Ti-Al system are presented to demonstrate the above techniques.

Anderson, Collin D.↗

Magneto-optic biosensor using bio-functionalized magnetized nanoparticles

A biosensor utilizing bio-functionalized magnetic nanoparticles is provided. An external magnetic field is applied to a suspension of magnetic nanoparticles. A linearly polarized incident light is applied to the suspension of magnetic nanoparticles. A photocurrent from polarized light scattering by bio-functionalized magnetic nanoparticles in liquid is detected. The magneto-optic sensing technique is applied to a micro-fluidic channel for rapid and sensitive detection with a small sample amount, and subsequent magnetic separation for detoxification. This technique is used for the detection of Brownian relaxation with time sweep as well as frequency sweep. The magneto-optical sensor enables rapidly detecting changes in local dynamic properties of the magnetic nanoparticles in liquids and magnetic modulation of ferromagnetic particles in liquid provides increased signal sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Status Report: Design and Fabricate Installation-Ready Test Capsule for the In-Situ Measurement of Elastic Properties Using an Optical Fiber-Based Measurement Technique

Microstructure evolution due to irradiation in a nuclear reactor can have a dramatic effect on material properties. A better understanding of this evolution is necessary for developing improved nuclear fuels and materials. The ability to measure such changes in real time is extremely limited due to the harsh conditions, high radiation fields, and limited access of the reactor environment. Through carefully designed experiments, measurement of elastic properties can be tied directly to microstructure. We present the methodology, design, and deployment plan for an instrument that has been developed to monitor grain microstructural changes during irradiation. Our measurement approach involves exciting and measuring the resonant frequency of a thin cantilever beam. Excitation and detection of the flexural vibrations of the beam are accomplished using optical methods that require only an optical fiber connection between the instrumentation and the sample. This technique has been demonstrated in a laboratory setting to monitor the recrystallization of highly textured copper during high temperature annealing. A test capsule incorporating this technique has been developed for in reactor testing. The capsule has been designed to be compatible with a reusable test module that allows simplified insertion in the TREAT reactor at INL. An exact replica of the instrument described in this Status Report, constructed from Quality Level 3 materials, is slated to be inserted into the TREAT reactor in FY19.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing soil water content variability across spatial scales from optimized high-resolution distributed temperature sensing technique

Fiber-optic Distributed Temperature Sensing, when combined with the Single-probe Heat-pulse technique can measure soil moisture (θ) across spatial scales. The key limitation of this system is in obtaining the relationship between soil thermal conductivity (λ) and θ for a specific field. Using the Department of Energy Atmospheric Radiation Measurement (ARM) site, this study tested a new methodology to account for the spatial variability in the λ-θ relationship using a Gaussian processes model. The resulting accurate θ measurements (RMSE = 0.03 m 3 m –3 ) were used to characterize the spatial variability of θ across scales and to develop an empirical equation that can correct for the changes in the θ spatial variability observed at different spatial resolutions. In addition, the number of required samples to accurately characterize θ and its variability over scales ranging from 5 m and 350 m were estimated. Finally, these findings provide key information to scale soil moisture from centimeters to hundreds of meters for process understanding.

54 ENVIRONMENTAL SCIENCES↗

Application of Digital Particle Imaging Velocimetry to Turbomachinery

Digital Particle Imaging Velocimetry (DPIV) is a powerful measurement technique, which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. The instantaneous planar velocity measurements obtained with PIV make it an attractive technique for use in the study of the complex flow fields encountered in turbomachinery. Many of the same issues encountered in the application of LDV to rotating machinery apply in the application of PIV. Techniques for optical access, light sheet delivery, CCD camera technology and particulate seeding are discussed. Results from the successful application of the PIV technique to both the blade passage region of a transonic axial compressor and the diffuser region of a high speed centrifugal compressor are presented. Both instantaneous and time-averaged flow fields were obtained. The 95% confidence intervals for the time-averaged velocity estimates were also determined. Results from the use of PIV to study surge in a centrifugal compressor are discussed. In addition, combined correlation/particle tracking results yielding super-resolution velocity measurements are presented.

Wernet, Mark P.↗

Ice Giant Exploration via Autonomous Optical Navigation

Long communication delays and the expense of supporting large-scale, human-managed spacecraft operations are significant impediments to deep-space exploration; however, implementing autonomy on-board the spacecraft can help overcome these hurdles. In this study, we investigate the feasibility of using on-board autonomous optical navigation techniques during approach to and proximity operations around the ice giants (i.e., Uranus and Neptune) while using the planets' satellites as optical beacons. Using beacon visibility and navigation uncertainties as metrics, we show what requirements (e.g., camera properties and beacon uncertainties) are needed to make these autonomously navigated missions feasible.

Olikara, Zubin↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam↗

Optical measurement systems

Some of the areas of research conducted at Lewis on optical measurement techniques are described. Two laser anemometer systems developed at Lewis are used to illustrate the special instrumentation needs encountered in aeropropulsion research. Velocity measurements to be made through small viewing ports, close to surfaces within the propulsion system components, and in turbulent or highly-accelerating flows are some of the significant challenges. The application to research facilities of two advanced optical systems, the rainbow schlieren and the combustor viewing system, is presented. The calibration and verification of commercial optical measuring systems, such as droplet sizing systems, are also discussed. Calibration techniques capable of simulating moving droplets for flight-type sizing systems are being developed at Lewis. The presentation concludes with a brief look at the forces driving future research on optical instrumentation.

Lesco, Daniel J.↗

Thermal annealing induced structural and optical properties of Se{sub 72}Te{sub 25}In{sub 3} thin films

Thin films of a- Se{sub 72}Te{sub 25}In{sub 3} were prepared by vacuum evaporation technique in a base pressure of 10{sup -6} Torr on to well cleaned glass substrate. a-Se{sub 72}Te{sub 25}In{sub 3} thin films were annealed at different temperatures below their crystallization temperatures for 2h. The structural analysis of the films has been investigated using X-ray diffraction technique. The optical absorption spectra of these films were measured in the wavelength range 400-1100 nm in order to derive the absorption coefficient of these films. The optical band gap of as prepared and annealed films as a function of photon energy has been studied. It has been found that the optical band gap decreases with increasing annealing temperatures in the present system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A passion for precision

For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic power and chirp measurements of amplified 19 ps pulses in traveling-wave and reflective semiconductor optical amplifiers using a linear pulse characterization technique

The dynamic chirp and power of amplified pulses in semiconductor optical amplifiers is of importance in the application of these devices as conventional amplifiers and in optical signal processing. Non-linear measurement techniques are appropriate for pulsewidths less than 5 ps but have low sensitivity for wider pulsewidths commonly present in moderate bit rate optical systems. Typical measurements of chirp and power of 20 GHz repetition rate amplified 19 ps pulsewidth pulses in traveling-wave and reflective SOAs are obtained using a linear characterization technique based on small-signal sinusoidal modulation at half the pulse stream repetition rate and post-processing of the resulting optical spectrums. The results show that the amplified pulse dynamic power and chirp can have a complex structure and thereby pulse spectrum, which in turn can influence pulse propagation in optical fiber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of thermal annealing on structure and optical band gap of amorphous Se{sub 72}Te{sub 25}Sb{sub 3} thin films

Thin films of a−Se{sub 72}Te{sub 25}Sb{sub 3} were prepared by vacuum evaporation technique in a base pressure of 10{sup −6} Torr on to well cleaned glass substrate. a−Se{sub 72}Te{sub 25}Sb{sub 3} thin films were annealed at different temperatures below their crystallization temperatures for 2h. The structural analysis of the films has been investigated using X-ray diffraction technique. The optical band gap of as prepared and annealed films as a function of photon energy in the wavelength range 400–1100 nm has been studied. It has been found that the optical band gap decreases with increasing annealing temperatures in the present system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical properties of WO{sub 3} thin films using surface plasmon resonance technique

Indigenously assembled surface plasmon resonance (SPR) technique has been exploited to study the thickness dependent dielectric properties of WO{sub 3} thin films. WO{sub 3} thin films (80 nm to 200 nm) have been deposited onto gold (Au) coated glass prism by sputtering technique. The structural, optical properties and surface morphology of the deposited WO{sub 3} thin films were studied using X-ray diffraction, UV-visible spectrophotometer, Raman spectroscopy, and Scanning electron microscopy (SEM). XRD analysis shows that all the deposited WO{sub 3} thin films are exhibiting preferred (020) orientation and Raman data indicates that the films possess single phase monoclinic structure. SEM images reveal the variation in grain size with increase in thickness. The SPR reflectance curves of the WO{sub 3}/Au/prism structure were utilized to estimate the dielectric properties of WO{sub 3} thin films at optical frequency (λ = 633 nm). As the thickness of WO{sub 3} thin film increases from 80 nm to 200 nm, the dielectric constant is seen to be decreasing from 5.76 to 3.42, while the dielectric loss reduces from 0.098 to 0.01. The estimated value of refractive index of WO{sub 3} film is in agreement to that obtained from UV-visible spectroscopy studies. The strong dispersion in refractive index is observed with wavelength of incident laser light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical spacing effect in organic photovoltaic cells incorporating a dilute acceptor layer

The addition of spacing layers in organic photovoltaic cells (OPVs) can enhance light absorption by optimizing the spatial distribution of the incident optical field in the multilayer structure. We explore the optical spacing effect in OPVs achieved using a diluted electron acceptor layer of C{sub 60}. While optical spacing is often realized by optimizing buffer layer thickness, we find that optical spacing via dilution leads to cells with similar or enhanced photocurrent. This is observed despite a smaller quantity of absorbing molecules, suggesting a more efficient use of absorbed photons. In fact, dilution is found to concentrate optical absorption near the electron donor-acceptor interface, resulting in a marked increase in the exciton diffusion efficiency. Contrasting the use of changes in thickness to engineer optical absorption, the use of dilution does not significantly alter the overall thickness of the OPV. Optical spacing via dilution is shown to be a viable alternative to more traditional optical spacing techniques and may be especially useful in the continued optimization of next-generation, tandem OPVs where it is important to minimize competition for optical absorption between individual sub-cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗