Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comparing the accuracy of four-dimensional photon dose calculations with three-dimensional calculations using moving and deforming phantoms

Purpose: Four-dimensional (4D) dose calculation algorithms, which explicitly incorporate respiratory motion in the calculation of doses, have the potential to improve the accuracy of dose calculations in thoracic treatment planning; however, they generally require greater computing power and resources than currently used for three-dimensional (3D) dose calculations. The purpose of this work was to quantify the increase in accuracy of 4D dose calculations versus 3D dose calculations. Methods: The accuracy of each dose calculation algorithm was assessed using measurements made with two phantoms. Specifically, the authors used a rigid moving anthropomorphic thoracic phantom and an anthropomorphic thoracic phantom with a deformable lung insert. To incorporate a clinically relevant range of scenarios, they programed the phantoms to move and deform with two motion patterns: A sinusoidal motion pattern and an irregular motion pattern that was extracted from an actual patient's breathing profile. For each combination of phantom and motion pattern, three plans were created: A single-beam plan, a multiple-beam plan, and an intensity-modulated radiation therapy plan. Doses were calculated using 4D dose calculation methods as well as conventional 3D dose calculation methods. The rigid moving and deforming phantoms were irradiated according to the three treatment plans and doses were measured using thermoluminescent dosimeters (TLDs) and radiochromic film. The accuracy of each dose calculation algorithm was assessed using measured-to-calculated TLD doses and a {gamma} analysis. Results: No significant differences were observed between the measured-to-calculated TLD ratios among 4D and 3D dose calculations. The {gamma} results revealed that 4D dose calculations had significantly greater percentage of pixels passing the 5%/3 mm criteria than 3D dose calculations. Conclusions: These results indicate no significant differences in the accuracy between the 4D and the 3D dose calculation methods inside the gross tumor volume. On the other hand, the film results demonstrated that the 4D dose calculations provided greater accuracy than 3D dose calculations in heterogeneous dose regions. The increase in accuracy of the 4D dose calculations was evident throughout the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance levels of EPID-based quality control for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) includes features such as a variable dose rate and gantry speed in addition to the beam modulation achieved with multileaf collimator (MLC) motion patterns employed in intensity modulated radiotherapy. Three tests have previously been proposed for the evaluation of the performance of VMAT delivery. In order to enable a convenient and accurate routine machine quality control (QC) program, the present study proposes tolerance levels for these tests based on a department-wide implementation of an electronic portal imaging device (EPID)-based QC. Methods: Three different VMAT tests--a picket fence (PF) test, a dose rate versus gantry speed (DRGS) test, and a dose rate versus MLC leaf speed (DRMLC) test--were performed on nine accelerators using two different EPIDs (aS1000 and aS500, Varian Medical Systems). All tests were repeated six times for each accelerator. The images were analyzed using an in-house-developed software. For the PF test, the positions and widths of individual MLC leaf gaps were compared to the mean value. In the DRGS and DRMLC tests, different combinations of dose rate, gantry speed, and MLC leaf speed were used to deliver identical doses to separate parts of the EPID. The tests were evaluated by looking for deviations in the constancy of the measured dose for the preset combinations of dose rate, gantry speed, and MLC leaf speed. Results: For the PF test, a 0.3 mm tolerance level was suggested for the positioning of the MLC leaves. The tolerance level for the gap width was 0.5 mm. For the DRGS and DRMLC tests, a 3% tolerance level was proposed. Conclusions: With the adapted levels of tolerance for an EPID-based approach, the PF, the DRGS, and the DRMLC tests offer a convenient and accurate machine QC program for linear accelerators used for VMAT.

07 ISOTOPE AND RADIATION SOURCES↗

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

60 APPLIED LIFE SCIENCES↗

Observation of coherent optical phonons excited by femtosecond laser radiation in Sb films by ultrafast electron diffraction method

The generation of coherent optical phonons in a polycrystalline antimony film sample has been investigated using femtosecond electron diffraction method. Phonon vibrations have been induced in the Sb sample by the main harmonic of a femtosecond Ti:Sa laser (λ = 800 nm) and probed by a pulsed ultrashort photoelectron beam synchronized with the pump laser. The diffraction patterns recorded at different times relative to the pump laser pulse display oscillations of electron diffraction intensity corresponding to the frequencies of vibrations of optical phonons: totally symmetric (A{sub 1g}) and twofold degenerate (E{sub g}) phonon modes. The frequencies that correspond to combinations of these phonon modes in the Sb sample have also been experimentally observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometry of divergent-beam diffraction.

Divergent-beam diffraction geometry for interpretation of Kossel diffraction patterns in space group assignment lattice parameters and structure factor evaluation

CRYSTAL STRUCTURE↗

Diffusion filter eliminates fringe effects of coherent laser light source

Diffusion filter comprised of small particles in colloidal suspension reduces the coherence of a laser beam used as a photographic light source. Interference patterns which obscure details in photographic film are eliminated, the intensity and collimation are moderately affected.

Olsasky, M. J.↗

High performance S-band horn antennas for radiometer use

Horn antennas of four types: pyramidal corrugated, conical corrugated, pyramidal dual mode and conical dual mode, have been constructed and evaluated for use as S-band radiometer antennas. Each of the structures is described and radiation patterns and impedance and resistive loss measurements including a layer of foreign material on a thin radome, are presented. A precision method for determining reflection losses is described using a multiprobe reflectometer technique. The same technique is also applied to the measurement of resistive losses by closing the ends of the antennas with short circuit plates and determining the losses from an accurate measurement of the reflection coefficient. The radiation patterns were recorded with the aid of a real-time digital computer. The stored patterns were then processed to yield gain and beam efficiency. It was concluded that it is possible to design a highly efficient antenna for radiometer use and to measure its parameters precisely. However, it was found that it is necessary to modify the conventional definition of beamwidth somewhat if this term is to be meaningful for radiometer applications.

Caldecott, R.↗

Aerodynamic and flow-visualization studies of two delta-wing entry vehicles at a Mach number of 20.3

The longitudinal, lateral, and directional aerodynamic characteristics of two space shuttle concepts have been obtained in helium for operational flight Reynolds numbers at angles of attack from minus 10 to 55 deg. Included are elevon control deflections, roll control due to ailerons, and the effects of a nose modification. Selected results were compared with those derived from tangent-cone and Newtonian theories. Also included are results of a flow-visualization study consisting of electron-beam-illuminated flow and surface oil-flow patterns.

Arrington, J. P.↗

Aerodynamic and flow visualization studies of variations in the geometry of irregular planform wings at a Mach number of 20.3

The longitudinal and summary lateral-directional stability characteristics have been obtained for a variety of irregular planform wings applied to a conceptual space shuttle orbiter. Three basic wing planforms with leading-edge sweep angles of 53.2 deg, 46.8 deg, and 35 deg were studied in conjunction with a series of inboard planform fillets with sweep angles up to 78 deg. The spanwise intersection point of the fillets and the basic wings was held constant. The data were obtained in the Langley 22-inch helium tunnel at a Mach number of 20.3 and a Reynolds number of 2.10 million based on model length. Model angle-of-attack range was from 0 deg to 54 deg at sideslip angles of 0 deg and minus 3.8 deg. Also included are results of a flow-visualization study consisting of electron-beam-illuminated flow and surface oil-flow patterns.

Stone, D. R.↗

Bistatic radar meteorological satellite

A technique is discussed that employs a radar transmitter with a moderate size antenna placed in a geosynchronous orbit with either a 0 degree or a low inclination orbit. The reflected signals from the precipitation are then received either on a single beam from a satellite having a beamwidth of about 6 degrees or preferably with a beam that scans the U.S. in a raster pattern with about 0.9 degrees beamwidth. While it would seem that a bistatic system with the transmitter at synchronous altitude and the receivers near the surface would not be a very efficient way of designing a radar system, it is somewhat surprising that the required power and antenna sizes are not that great. Two factors make the meteorological application somewhat more attractive than the bistatic detection of point targets. First, the bistatic reflections of radar signals from precipitation are to a large extent omnidirectional, and while raindrops are spheriods rather than spheres, the relationship of the reflectivity of the rain to rainfall rate can be easily derived. The second reason is that the rain echo signal level is independent of range from a receive only radar, and if the bistatic system works at all, it will work at long ranges.

Nathanson, F. E.↗

Fundamental mode oscillation of a buried ridge waveguide laser array

An eight-element phase-locked array of index-guided separate confinement ridge AlGaAs diode lasers is fabricated. In this array the absorption of light in the region between lasers is negligible and the gain profile across the array is nearly uniform. Unlike most other arrays, this array oscillates in its fundamental mode. Stable radiation patterns of near diffraction-limited single narrow beam with 1.6 deg width are obtained. The beam width approaches the theoretical limit for the present array structure.

Mukai, S.↗

Limits of X-ray variability in active galactic nuclei

A significant correlation is demonstrataed here between the X-ray luminosity and the timescale of X-ray variability for Seyfert galaxies and quasars. This is interpreted as evidence that the emitting plasma is near the limit of being dominated by electron-positron pairs. BL Lac objects do not follow this pattern; this may be due either to relativistic beaming or to the differing importance of the pair production process.

Barr, P.↗

Experimental radar Doppler wind profile measurements at Kennedy Space Center

A wind profile radar demonstration project was sponsored by the Space Transportation System (STS) Program Office to study the feasibility of incorporating continuous, high time resolution radar wind data into STS operations. This project required wind profile radars to be deployed in the vicinity of the Shuttle launch site into an environment quite unlike typical VHF profiler sites. Two 50 MHz radars were operated at the Kennedy Space Center in environments that were noisy in terms of RFI, large stationary ground clutter sources, non-stationary clutter sources, and heavy local aircraft traffic. Processing compensation for these operational constraints magnified design limitations of the research-level radars used in the demonstration. This report addresses the importance of system design for unique or particular applications with reference to finite radiation patterns, zero-Doppler processing, radar frequency, and beam pointing.

Jost, R. J.↗

Multispectral observations of the Jovian aurora

The upper atmospheres of the Earth and the outer planets form a screen on which precipitating charged particles, like the electron beam in a television, trace fleeting, but revealing patterns of visible, ultraviolet, infrared, and x ray emissions that offer valuable clues to processes occurring within the planetary magnetospheres. At Earth, years of in situ measurements, as well as ground based observations, have yielded a picture (still fuzzy) where the interaction of the solar wind with the magnetosphere of the Earth provides a complex path for the storage and release of energy during magnetic substorms; the ultimate manifestation of terrestrial auroral processes. More recent global imaging of substorm events from high above the Earth (greater than 3.5 R(sub e)) by Dynamics Explorer have made a unique contribution towards understanding the global and temporal evolution of such auroral events by providing a morphological perspective and by providing the crucial observational link that allows the separation of spatial and temporal variations inherent in the interpretation of in situ data. A similar role was played by the Hubble Space Telescope (HST) during the recent encounter of Ulysses with Jupiter in helping to define a new paradigm in Jovian auroral physics. The old paradigm portrayed Jupiter's magnetosphere as totally dominated by internal processes (i.e. Io related tori, heavy ions, etc.) where energetic heavy ion precipitation in the inner magnetosphere was solely responsible for the observed auroral phenomena. Ulysses and HST portray a more Earth-like paradigm where electron acceleration in the outer magnetosphere near the boundary with the solar wind plays a distinct role in the formation of auroral hot spots, yet energetic heavy ions also enter into the picture (similar to the role of the energetic ions from the terrestrial ring current during magnetic substorms). These heavy ions as a result of excitation during their transit through the atmosphere produce the x ray emissions observed in Roentgensatellit (ROSAT) x ray energy spectra.

Source record↗

The composite classification problem in optical information processing

Optical pattern recognition allows objects to be recognized from their images and permits their positional parameters to be estimated accurately in real time. The guiding principle behind optical pattern recognition is that a lens focusing a beam of coherent light modulated with an image produces the two-dimensinal Fourier transform of that image. When the resulting output is further transformed by the matched filter corresponding to the original image, one obtains the autocorrelation function of the original image, which has a peak at the origin. Such a device is called an optical correlator and may be used to recognize the locate the image for which it is designed. (From a practical perspective, an approximation to the matched filter must be used since the spatial light modulator (SLM) on which the filter is implemented usually does not allow one to independently control both the magnitude and phase of the filter.) Generally, one is not just concerned with recognizing a single image but is interested in recognizing a variety of rotated and scaled views of a particular image. In order to recognize these different views using an optical correlator, one may select a subset of these views (whose elements are called training images) and then use a composite filter that is designed to produce a correlation peak for each training image. Presumably, these peaks should be sharp and easily distinguishable from the surrounding correlation plane values. In this report we consider two areas of research regarding composite optical correlators. First, we consider the question of how best to choose the training images that are used to design the composite filter. With regard to quantity, the number of training images should be large enough to adequately represent all possible views of the targeted object yet small enough to ensure that the resolution of the filter is not exhausted. As for the images themselves, they should be distinct enough to avoid numerical difficulties yet similar enough to avoid gaps in which certain views of the target will be unrecognized. One method that we introduce to study this problem is called probing and involves the creation of the artificial imagery. The second problem we consider involves the clasification of the composite filter's correlation plane data. In particular, we would like to determine not only whether or not we are viewing a training image, but, in the former case, we would like to determine which training image is being viewed. This second problem is investigated using traditional M-ary hypothesis testing techniques.

Hall, Eric B.↗

Lunar Geodetic Opportunities with the Laser Altimeter on LRO

The Lunar Reconnaissance Orbiter (LRO) is to be launched at the end of 2008 and will carry 7 instruments, one of which is a laser altimeter (LOLA), and obtain observations of the Moon for a period of 1 year. The orbit will be near polar and approximately circular at 50 km altitude with monthly orbital adjustments to maintain the mean altitude. The LOLA instrument has a -10 cm single-shot accuracy, with 5 beams, and operates at 28 Hz. It provides 5 adjacent profiles, each approximately 12 to 15 meters apart with a swath of approximately 65 meters. The 5 beams are arranged in a cross-shaped pattern that provides simultaneous along and cross track altimetry and providing slopes in 2 orthogonal directions every 50 meters along track. In combination with the LRO tracking data LOLA will be used to improve the model of the lunar gravity by using the altimeter on both the lunar near-side and far-side as an additional tracking system to enable precise positioning of the LRO spacecraft at about the 50 meter level rms. The instrument is expected to provide full polar coverage at very high northern and southern latitudes with spatial resolutions of 25 meters or better. In addition to the range to the surface LOLA measures the surface roughness from the spreading of the laser pulse and also the reflectance of the surface at 1064 nm. These measurements in conjunction with the altimetry will assist in the selection of future landing sites for future robotic and human missions to the Moon.

Zuber, Maria T.↗

Solar cell anomaly detection method and apparatus

A method is provided for detecting cracks and other imperfections in a solar cell, which includes scanning a narrow light beam back and forth across the cell in a raster pattern, while monitoring the electrical output of the cell to find locations where the electrical output varies significantly. The electrical output can be monitored on a television type screen containing a raster pattern with each point on the screen corresponding to a point on the solar cell surface, and with the brightness of each point on the screen corresponding to the electrical output from the cell which was produced when the light beam was at the corresponding point on the cell. The technique can be utilized to scan a large array of interconnected solar cells, to determine which ones are defective.

Miller, Emmett L.↗