Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A quantitative figure of merit for battery SEI films and their use as functional solid-state electrolytes

As a key passivation film that governs battery operation, the solid electrolyte interphase (SEI) has long been credited for enabling high-performance batteries or blamed for their eventual death. However, qualitative descriptions of the SEI often found in the literature (e.g., “conductive,” “passivating”) highlight our incomplete understanding of this layer, where even the most basic properties foundational to SEI function remain difficult to measure. Here, we quantify SEI conductivities and SEI transference numbers using a separator-free Cu|SEI|Li architecture that treats the SEI as a functional solid-state electrolyte (SSE). We find that while any SEI property alone (e.g., electronic conductivity) is weakly correlated (R 2 < 0.67) with battery performance (e.g., Coulombic efficiency), a strong correlation (R 2 > 0.99) can be achieved by defining the “SEI cT number” as a product between the SEI transference number (T) and the ratio of SEI conductivities (c). Analogous to the thermoelectric figure of merit (i.e., zT ), SEI cT quantitatively benchmarks the holistic impact of SEI properties on battery performance and underscores the pitfalls of citing such properties in isolation. Perhaps most strikingly, we demonstrate that Li metal deposition and stripping at room temperature is possible in our separator-free Cu|SEI|Li cell, confirming that the SEI can function precisely as an SSE. Together, these results enrich our understanding of the SEI, not just as a passivation layer but as a functional structure that can potentially have important implications for solid-state batteries.

Science & Technology - Other Topics↗

A quantitative imaging framework for lithium morphology: Linking deposition uniformity to cycle stability in lithium metal batteries

Characterizing the morphology of lithium (Li) is crucial for developing long-lasting lithium metal batteries. It is well established that more uniform Li deposition correlates with better cell performance. Li morphology is often characterized through qualitative analysis of scanning electron microscopy (SEM) images; however, there are no widely accepted metrics to quantitatively describe deposition uniformity. Here, we propose a framework to quantify uniformity through SEM image analysis via the index of dispersion (ID) metric, which is defined and presented in the context of Li metal batteries. We also explore experimental impacts of sampling protocols onIDmeasurements. Our results demonstrate that theIDmetric is highly sensitive to variations in deposition uniformity, including the coexistence and uniformity of multiple morphologies, uniformity within a single morphology, and particle size distribution uniformity. Furthermore, it is demonstrated that uniformity, as measured by theID, can be related to the average potential of Li||Li symmetric cells over cycling. Higher capacity cycling leads to more pronounced changes in bothIDand average cell potential. Local minima/maxima are found consistently in bothIDand average cell potential immediately before cells short-circuit, which we suggest may indicate a collapse of the microstructure prior to failure. We put forward this framework as a more robust approach to quantify Li deposition uniformity, advancing the development of Li metal batteries that are safer and longer lasting.

Science & Technology - Other Topics↗

Cancer-associated p53 tetramerization domain mutants: quantitative analysis reveals a low threshold for tumor suppressor inactivation

The tumor suppressor p53, a 393-amino acid transcription factor, induces cell cycle arrest and apoptosis in response to genotoxic stress. Its inactivation via the mutation of its gene is a key step in tumor progression, and tetramer formation is critical for p53 post-translational modification and its ability to activate or repress the transcription of target genes vital in inhibiting tumor growth. About 50% of human tumors have TP53 gene mutations; most are missense ones that presumably lower the tumor suppressor activity of p53. In this study, we explored the effects of known tumor-derived missense mutations on the stability and oligomeric structure of p53; our comprehensive, quantitative analyses encompassed the tetramerization domain peptides representing 49 such substitutions in humans. Their effects on tetrameric structure were broad, and the stability of the mutant peptides varied widely ({Delta}T{sub m} = 4.8 {approx} -46.8 C). Because formation of a tetrameric structure is critical for protein-protein interactions, DNA binding, and the post-translational modification of p53, a small destabilization of the tetrameric structure could result in dysfunction of tumor suppressor activity. We suggest that the threshold for loss of tumor suppressor activity in terms of the disruption of the tetrameric structure of p53 could be extremely low. However, other properties of the tetramerization domain, such as electrostatic surface potential and its ability to bind partner proteins, also may be important.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics

Liquid chromatography-mass spectrometry (LC-MS)-based quantitative proteomics has become increasingly applied for a broad range of biological applications due to growing capabilities for broad proteome coverage and good accuracy in quantification. Herein, we review the current LC-MS-based quantification methods with respect to their advantages and limitations, and highlight their potential applications.

59 BASIC BIOLOGICAL SCIENCES↗

On single-crystal neutron-diffraction in DACs: quantitative structure refinement of light elements on SNAP and TOPAZ

Quantitative single crystal neutron-diffraction in diamond anvil cells has so far been limited by the neutron flux available at the various neutron sources. As a result, highly precise measurements of the exact position of light elements have not been possible preventing, for example, structural studies of hydrogen and hydrogen bonds under pressure. Here we report experiments carried out on SNAP at the Spallation Neutron Source (ORNL, TN, USA) to explore the possibility and current limits of such studies. Furthermore, we benchmarked the obtained data quality with reference experiments carried out on TOPAZ, a dedicated single-crystal instrument.We show that measuring single-crystal diffraction intensities on SNAP is possible to such a precision that we are able to resolve the hydrogen bonds in potassium dideuterium phosphate (DKDP) as well as in ice VI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative Analysis of Ultralow-Density Materials Using Laboratory-Based Quasi-Monochromatic Radiography

The measurement of the density of materials, especially ultralow-density foams, is difficult in that the measurement must be precise and localizable. The density of the material is often governed by its cellular (i.e., porous) structure, and many techniques exist to create that structure. Often, the cellular structure can vary from one location within the material to another, and when at low densities (i.e., densities lower than ~500 mg/cm 3 ), it can vary due to shrinkage during syneresis, collapse under the weight of gravity, or gas/water vapor uptake. Quantifying this variation is important for a variety of applications, especially when used in plasma physics targets. Knowing the density and its variation across the sample is critical for experimental results to be accurately predicted by physics calculations and for modeling the results of the physics targets. The use of quasi-monochromatic radiography provides a means to image the two-dimensional (2-D) distribution of density variation within silica aerogel materials and to quantitatively measure that variation from sample to sample and lot to lot. For this work, two batches of silica aerogels with targeted densities of ~20 mg/cm 3 were created, one batch at Lawrence Livermore National Laboratory, and the other batch at Los Alamos National Laboratory. Outlined here is a quasi-monochromatic radiography system using various X-ray sources coupled to a doubly curved crystal optic and X-ray charge-coupled device camera to image and characterize these materials. It was found that measuring the density both gravimetrically and using quasi-monochromatic radiography were statistically identical, although the two batches were found to be slightly higher than their targeted density due to shrinkage. The radiography system also provided 2-D information as to the aerogel quality, i.e., presence of voids, chipped material, or inclusions.

36 MATERIALS SCIENCE↗

A QUANTITATIVE ANALYSIS OF DISTANT OPEN CLUSTERS

The oldest open star clusters are important for tracing the history of the Galactic disk, but many of the more distant clusters are heavily reddened and projected against the rich stellar background of the Galaxy. We have undertaken an investigation of several distant clusters (Berkeley 19, Berkeley 44, King 25, NGC 6802, NGC 6827, Berkeley 52, Berkeley 56, NGC 7142, NGC 7245, and King 9) to develop procedures for separating probable cluster members from the background field. We next created a simple quantitative approach for finding approximate cluster distances, reddenings, and ages. We first conclude that with the possible exception of King 25 they are probably all physical clusters. We also find that for these distant clusters our typical errors are about {+-}0.07 in E(B - V), {+-}0.15 in log(age), and {+-}0.25 in (m - M){sub o}. The clusters range in age from 470 Myr to 7 Gyr and range from 7.1 to 16.4 kpc from the Galactic center.

79 ASTRONOMY AND ASTROPHYSICS↗

A QUANTITATIVE EXPLANATION OF THE OBSERVED POPULATION OF MILKY WAY SATELLITE GALAXIES

We revisit the well known discrepancy between the observed number of Milky Way (MW) dwarf satellite companions and the predicted population of cold dark matter (CDM) subhalos, in light of the dozen new low-luminosity satellites found in imaging data from the Sloan Digital Sky Survey (SDSS) and our recent calibration of the SDSS satellite detection efficiency, which implies a total satellite population far larger than these dozen discoveries. We combine a detailed dynamical model for the CDM subhalo population with simple, physically motivated prescriptions for assigning a stellar content to each subhalo, then apply observational selection effects and compare to the current observational census. Reconciling the observed satellite population with CDM predictions still requires strong mass-dependent suppression of star formation in low-mass subhalos: models in which the stellar mass is a constant fraction F {sub *}({omega} {sub b}/{omega} {sub m}) of the subhalo mass M {sub sat} at the time it becomes a satellite fail for any choice of F {sub *}. However, previously advocated models that invoke suppression of gas accretion after reionization in halos with circular velocity V {sub circ} {<=} V {sub crit} {approx} 35 km s{sup -1} can reproduce the observed satellite counts for -15 {<=} M{sub V} {<=} 0. Successful models require F {sub *} {approx} 10{sup -3} in halos with V {sub circ}>V {sub crit} and strong suppression of star formation before reionization in halos with V {sub circ} {approx}< 10 km s{sup -1}; models without pre-reionization suppression predict far too many satellites with -5 {<=} M{sub V} {<=} 0. In this successful model, the dominant fraction of stars formed after reionization at all luminosities. Models that match the satellite luminosity distribution also match the observed heliocentric radius distribution, and they reproduce the observed characteristic stellar velocity dispersion {sigma}{sub *} {approx} 5-10 km s{sup -1} of the SDSS dwarfs given the observed sizes ({approx}50-200 pc) of their stellar distributions. The model satellites have M(<300 pc) {approx} 10{sup 7} M {sub sun} as observed even though their present-day total halo masses span more than two orders of magnitude; the constancy of central masses mainly reflects the profiles of CDM halos. Our modeling shows that natural physical mechanisms acting within the CDM framework can quantitatively explain the properties of the MW satellite population as it is presently known, thus providing a convincing solution to the 'missing satellite' problem.

79 ASTRONOMY AND ASTROPHYSICS↗

QUANTITATIVE SPECTROSCOPY OF BLUE SUPERGIANT STARS IN THE DISK OF M81: METALLICITY, METALLICITY GRADIENT, AND DISTANCE

The quantitative spectral analysis of low-resolution ({approx}5 A) Keck LRIS spectra of blue supergiants in the disk of the giant spiral galaxy M81 is used to determine stellar effective temperatures, gravities, metallicities, luminosities, interstellar reddening, and a new distance using the flux-weighted gravity-luminosity relationship. Substantial reddening and extinction are found with E(B - V) ranging between 0.13 and 0.38 mag and an average value of 0.26 mag. The distance modulus obtained after individual reddening corrections is 27.7 {+-} 0.1 mag. The result is discussed with regard to recently measured tip of the red giant branch and Cepheid distances. The metallicities (based on elements such as iron, titanium, magnesium) are supersolar ( Almost-Equal-To 0.2 dex) in the inner disk (R {approx}< 5 kpc) and slightly subsolar ( Almost-Equal-To - 0.05 dex) in the outer disk (R {approx}> 10 kpc) with a shallow metallicity gradient of 0.034 dex kpc{sup -1}. The comparison with published oxygen abundances of planetary nebulae and metallicities determined through fits of Hubble Space Telescope color-magnitude diagrams indicates a late metal enrichment and a flattening of the abundance gradient over the last 5 Gyr. This might be the result of gas infall from metal-rich satellite galaxies. Combining these M81 metallicities with published blue supergiant abundance studies in the Local Group and the Sculptor Group, a galaxy mass-metallicity relationship based solely on stellar spectroscopic studies is presented and compared with recent studies of Sloan Digital Sky Survey star-forming galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EVOLUTION OF SOLAR FLUX FROM 0.1 nm TO 160 {mu}m: QUANTITATIVE ESTIMATES FOR PLANETARY STUDIES

Understanding changes in the solar flux over geologic time is vital for understanding the evolution of planetary atmospheres because it affects atmospheric escape and chemistry, as well as climate. We describe a numerical parameterization for wavelength-dependent changes to the non-attenuated solar flux appropriate for most times and places in the solar system. We combine data from the Sun and solar analogs to estimate enhanced UV and X-ray fluxes for the young Sun and use standard solar models to estimate changing visible and infrared fluxes. The parameterization, a series of multipliers relative to the modern top of the atmosphere flux at Earth, is valid from 0.1 nm through the infrared, and from 0.6 Gyr through 6.7 Gyr, and is extended from the solar zero-age main sequence to 8.0 Gyr subject to additional uncertainties. The parameterization is applied to a representative modern day flux, providing quantitative estimates of the wavelength dependence of solar flux for paleodates relevant to the evolution of atmospheres in the solar system (or around other G-type stars). We validate the code by Monte Carlo analysis of uncertainties in stellar age and flux, and with comparisons to the solar proxies {kappa}{sup 1} Cet and EK Dra. The model is applied to the computation of photolysis rates on the Archean Earth.

79 ASTRONOMY AND ASTROPHYSICS↗

TRACKING CORONAL FEATURES FROM THE LOW CORONA TO EARTH: A QUANTITATIVE ANALYSIS OF THE 2008 DECEMBER 12 CORONAL MASS EJECTION

We have tracked a slow magnetic cloud associated coronal mass ejection (CME) continuously from its origin as a flux rope structure in the low solar corona over a four-day passage to impact with spacecraft located near Earth. Combining measurements from the STEREO, ACE, and Wind space missions, we are able to follow major elements with enough specificity to relate pre-CME coronal structure in the low corona to the corresponding elements seen in the near-Earth in situ data. Combining extreme ultraviolet imaging, quantitative Thomson scattering data throughout the flight of the CME, and ''ground-truth'' in situ measurements, we: (1) identify the plasma observed by ACE and Wind with specific features in the solar corona (a segment of a long flux rope); (2) determine the onset mechanism of the CME (destabilization of a filament channel following flare reconnection, coupled with the mass draining instability) and demonstrate that it is consistent with the in situ measurements; (3) identify the origin of different layers of the sheath material around the central magnetic cloud (closed field lifted from the base of the corona, closed field entrained during passage through the corona, and solar wind entrained by the front of the CME); (4) measure mass accretion of the system via snowplow effects in the solar wind as the CME crossed the solar system; and (5) quantify the kinetic energy budget of the system in interplanetary space, and determine that it is consistent with no long-term driving force on the CME.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative spectroscopy of blue supergiants in metal-poor dwarf galaxy NGC 3109

We present a quantitative analysis of the low-resolution (∼4.5 Å) spectra of 12 late-B and early-A blue supergiants (BSGs) in the metal-poor dwarf galaxy NGC 3109. A modified method of analysis is presented which does not require use of the Balmer jump as an independent T {sub eff} indicator, as used in previous studies. We determine stellar effective temperatures, gravities, metallicities, reddening, and luminosities, and combine our sample with the early-B-type BSGs analyzed by Evans et al. to derive the distance to NGC 3109 using the flux-weighted gravity-luminosity relation (FGLR). Using primarily Fe-group elements, we find an average metallicity of [ Z-bar ] = –0.67 ± 0.13, and no evidence of a metallicity gradient in the galaxy. Our metallicities are higher than those found by Evans et al. based on the oxygen abundances of early-B supergiants ([ Z-bar ] = –0.93 ± 0.07), suggesting a low α/Fe ratio for the galaxy. We adjust the position of NGC 3109 on the BSG-determined galaxy mass-metallicity relation accordingly and compare it to metallicity studies of H II regions in star-forming galaxies. We derive an FGLR distance modulus of 25.55 ± 0.09 (1.27 Mpc) that compares well with Cepheid and tip of the red giant branch distances. The FGLR itself is consistent with those found in other galaxies, demonstrating the reliability of this method as a measure of extragalactic distances.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative spectroscopic J-band study of red supergiants in Perseus OB-1

We demonstrate how the metallicities of red supergiant (RSG) stars can be measured from quantitative spectroscopy down to resolutions of ≈3000 in the J-band. We have obtained high resolution spectra on a sample of the RSG population of h and χ Persei, a double cluster in the solar neighborhood. We show that careful application of the MARCS model atmospheres returns measurements of Z consistent with solar metallicity. Using two grids of synthetic spectra–one in pure LTE and one with non-LTE (NLTE) calculations for the most important diagnostic lines–we measure Z = +0.04 ± 0.10 (LTE) and Z = –0.04 ± 0.08 (NLTE) for the sample of eleven RSGs in the cluster. We degrade the spectral resolution of our observations and find that those values remain consistent down to resolutions of less than λ/δλ of 3000. Using measurements of effective temperatures we compare our results with stellar evolution theory and find good agreement. We construct a synthetic cluster spectrum and find that analyzing this composite spectrum with single-star RSG models returns an accurate metallicity. We conclude that the RSGs make ideal targets in the near infrared for measuring the metallicities of star forming galaxies out to 7-10 Mpc and up to 10 times farther by observing the integrated light of unresolved super star clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative analysis of time-resolved microwave conductivity data

Flash-photolysis time-resolved microwave conductivity (fp-TRMC) is a versatile, highly sensitive technique for studying the complex photoconductivity of solution, solid, and gas-phase samples. The purpose of this paper is to provide a standard reference work for experimentalists interested in using microwave conductivity methods to study functional electronic materials, describing how to conduct and calibrate these experiments in order to obtain quantitative results. The main focus of the paper is on calculating the calibration factor, K, which is used to connect the measured change in microwave power absorption to the conductance of the sample. We describe the standard analytical formulae that have been used in the past, and compare them to numerical simulations. This comparison shows that the most widely used analytical analysis of fp-TRMC data systematically under-estimates the transient conductivity by ~60%. We suggest a more accurate semi-empirical way of calibrating these experiments. However, we emphasize that the full numerical calculation is necessary to quantify both transient and steady-state conductance for arbitrary sample properties and geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Misinterpreting modified gravity as dark energy: a quantitative study

Standard cosmological data analyses typically constrain simple phenomenological dark-energy parameters, for example the present-day value of the equation of state parameter, w 0 , and its variation with scale factor, w a . However, results from such an analysis cannot easily indicate the presence of modified gravity. Even if general relativity does not hold, experimental data could still be fit sufficiently well by a phenomenological w 0 w a CDM, unmodified-gravity model. Hence, it would be very useful to know if there are generic signatures of modified gravity in standard analyses. Here we present, for the first time to our knowledge, a quantitative mapping showing how modified gravity models look when (mis)interpreted within the standard unmodified-gravity analysis. Scanning through a broad space of modified-gravity (Horndeski) models, and assuming a near-future survey consisting of CMB, BAO, and SNIa observations, we report values of the best-fit set of cosmological parameters including (w 0 , w a ) that would be inferred if modified gravity were at work. We find that modified gravity models that can masquerade as standard gravity lead to very specific biases in standard-parameter spaces. Here, we also comment on implications for measurements of the amplitude of mass fluctuations described by the parameter S 8 .

79 ASTRONOMY AND ASTROPHYSICS↗