Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Advanced Spectroscopic and Thermal Imaging Instrumentation for Shock Tube and Ballistic Range Facilities

The Electric Arc Shock Tube (EAST) facility and Hypervelocity Free Flight Aerodynamic Facility (HFFAF, an aeroballistic range) at NASA Ames support basic research in aerothermodynamic phenomena of atmospheric entry, specifically shock layer radiation spectroscopy, convective and radiative heat transfer, and transition to turbulence. Innovative optical instrumentation has been developed and implemented to meet the challenges posed from obtaining such data in these impulse facilities. Spatially and spectrally resolved measurements of absolute radiance of a travelling shock wave in EAST are acquired using multiplexed, time-gated imaging spectrographs. Nearly complete spectral coverage from the vacuum ultraviolet to the near infrared is possible in a single experiment. Time-gated thermal imaging of ballistic range models in flight enables quantitative, global measurements of surface temperature. These images can be interpreted to determine convective heat transfer rates and reveal transition to turbulence due to isolated and distributed surface roughness at hypersonic velocities. The focus of this paper is a detailed description of the optical instrumentation currently in use in the EAST and HFFAF.

Grinstead, Jay H.↗

The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-QI-14: Quantitative Variogram Detection of Mild, Unilateral Disease in Elastase-Treated Rats

Purpose: Determining the presence of mild or early disease in the lungs can be challenging and subjective. We present a rapid and objective method for evaluating lung damage in a rat model of unilateral mild emphysema based on a new approach to heterogeneity assessment. We combined octree decomposition (used in three-dimensional (3D) computer graphics) with variograms (used in geostatistics to assess spatial relationships) to evaluate 3D computed tomography (CT) lung images for disease. Methods: Male, Sprague-Dawley rats (232 ± 7 g) were intratracheally dosed with 50 U/kg of elastase dissolved in 200 μL of saline to a single lobe (n=6) or with saline only (n=5). After four weeks, 3D micro-CT images were acquired at end expiration on mechanically ventilated rats using prospective gating. Images were masked, and lungs were decomposed to homogeneous blocks of 2×2×2, 4×4×4, and 8×8×8 voxels using octree decomposition. The spatial variance – the square of the difference of signal intensity – between all pairs of the 8×8×8 blocks was calculated. Variograms – graphs of distance vs. variance - were made, and data were fit to a power law and the exponent determined. The mean HU values, coefficient of variation (CoV), and the emphysema index (EI) were calculated and compared to the variograms. Results: The variogram analysis showed that significant differences between groups existed (p<0.01), whereas the mean HU (p=0.07), CoV (p=0.24), and EI (p=0.08) did not. Calculation time for the variogram for a typical 1000 block decomposition was ∼6 seconds, and octree decomposition took ∼2 minutes. Decomposing the images prior to variogram calculation resulted in a ∼700x decrease in time as compared to other published approaches. Conclusions: Our results suggest that the approach combining octree decomposition and variogram analysis may be a rapid, non-subjective, and sensitive imaging-based biomarker for quantitative characterization of lung disease.

60 APPLIED LIFE SCIENCES↗

Energetic neutral atoms: Imaging the magnetospheric ring current

Magnetospheric imaging is a new discipline whose goal is to make pictures of the energetic particle populations trapped in the magnetic field of Earth (or any other planet). This project demonstrated the technical feasibility and scientific validity of magnetospheric imaging using energetic neutral atoms (ENA) with the publication and quantitative analysis of the first ENA images ever obtained from space. ENA's are produced when singly-charged energetic (approximately 100 keV) trapped ions make an atomic collision with the neutral hydrogen atoms which boil of the top of the Earth's atmosphere. These hydrogen atoms suffuse the entire trapping volume of the magnetosphere. The energetic ion steals the electron from the atmospheric hydrogen, so the energetic ion is transformed into an energetic neutral atom with a velocity of several thousands of kilometers/second. Moreover, the new-born ENA preserves the velocity that the trapped ion had at the time of the collision. Consequently, any population of energetic ions emits ENA's.

Roelof, Edmond C.↗

Electroluminescence Imaging: A Study in the Impact of Microscopic Surface Defects

Electroluminescence (EL) imaging can be used as a quantitative characterization method for solar cell performance when combined with image processing, allowing for the impact of dust grain size on electroluminescence imaging characteristics to be investigated. Simulating these results via modelling can help to predict what dust grain sizes, if any, will have a greater impact on performance.

photovoltaics↗

Quantitative analysis of breast echotexture patterns in automated breast ultrasound images

Purpose: Breast tissue composition is considered to be associated with breast cancer risk. This study aimed to develop a computer-aided classification (CAC) system to automatically classify echotexture patterns as heterogeneous or homogeneous using automated breast ultrasound (ABUS) images. Methods: A CAC system was proposed that can recognize breast echotexture patterns in ABUS images. For each case, the echotexture pattern was assessed by two expert radiologists and classified as heterogeneous or homogeneous. After neutrosophic image transformation and fuzzy c-mean clusterings, the lower and upper boundaries of the fibroglandular tissues were defined. Then, the number of hypoechoic regions and histogram features were extracted from the fibroglandular tissues, and the support vector machine model with the leave-one-out cross-validation method was utilized as the classifier. The authors’ database included a total of 208 ABUS images of the breasts of 104 females. Results: The accuracies of the proposed system for the classification of heterogeneous and homogeneous echotexture patterns were 93.48% (43/46) and 92.59% (150/162), respectively, with an overall Az (area under the receiver operating characteristic curve) of 0.9786. The agreement between the radiologists and the proposed system was almost perfect, with a kappa value of 0.814. Conclusions: The use of ABUS and the proposed method can provide quantitative information on the echotexture patterns of the breast and can be used to evaluate whether breast echotexture patterns are associated with breast cancer risk in the future.

60 APPLIED LIFE SCIENCES↗

Sulphate resistance of low‐clinker engineered cementitious composites examined by MicroXRF imaging

Abstract Engineered cementitious composites (ECC) are a class of high‐performing fibre‐reinforced cementitious materials recognised for their increased ductility and durability compared to conventional cement‐based materials, owing to their autogenously controlled tight crack widths, even when subjected to high strains. To reduce ECC's environmental impact, this research examines the use of a low‐clinker binder − limestone‐calcined clay cement (LC3) − as an alternative to portland cement (PC), along with fly ash to further reduce the clinker proportion and the embodied CO 2 of the formulations. In conventional concrete, LC3 hydrates to a denser microstructure resulting from the synergistic reaction between limestone and calcined clay. At the lower water contents typical of ECC and with the presence of fly ash, the influence of the binder composition on the microstructure is difficult to anticipate. To examine the influence of these compositional variables on microstructure, permeability and durability, the sulphate resistance of LC3‐based ECC is explored. Specifically, the ECC‐LC3 blends are designed with high clinker replacement rate of 75% by mass of binder and contain either conventional fly ash or reclaimed fly ash at 50% by mass of binder. Expansion of ECC‐LC3 samples subjected to standard sodium sulphate test conditions was measured up to 12 months and the depth of penetration of sulphates into the ECC‐LC3 of varying compositions was quantified using micro‐X‐Ray Fluorescence (microXRF) imaging and modelling. The expansion results show that the ECC‐LC3 formulations performed better than the PC samples and can provide adequate resistance to external sulphate attack, even when reclaimed fly ashes are used in place of the conventional ash. In addition, the shallow penetration of sulphate into these cementitious composites demonstrates the low diffusion coefficients values that were determined using the quantitative data from MicroXRF imaging.

Microscopy↗

Quantitative Fluorescence Microscopy To Determine Molecular Occupancy of Phospholipid Vesicles

Encapsulation of molecules in phospholipid vesicles provides unique opportunities to study chemical reactions in small volumes as well as the behavior of individual proteins, enzymes, and ribozymes in a confined region without requiring a tether to immobilize the molecule to a surface. These experiments generally depend on generating a predictable loading of vesicles with small numbers of target molecules and thus raise a significant measurement challenge, namely, to quantify molecular occupancy of vesicles at the single-molecule level. In this work, we describe an imaging experiment to measure the time-dependent fluorescence from individual dye molecules encapsulated in ~130 nm vesicles that are adhered to a glass surface. For determining a fit of the molecular occupancy data to a Poisson model, it is critical to count empty vesicles in the population since these dominate the sample when the mean occupancy is small, λ ≤ ~1. Counting empty vesicles was accomplished by subsequently labeling all the vesicles with a lipophilic dye and reimaging the sample. By counting both the empty vesicles and those containing fluors, and quantifying the number of fluors present, we demonstrate a self-consistent Poisson distribution of molecular occupancy for well-solvated molecules, as well as anomalies due to aggregation of dye, which can arise even at very low solution concentrations. Here, by observation of many vesicles in parallel in an image, this approach provides quantitative information about the distribution of molecular occupancy in a population of vesicles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualization and quantification of magnetic nanoparticles into vesicular systems by combined atomic and magnetic force microscopy

We report a phenomenological approach for the quantification of the diameter of magnetic nanoparticles (MNPs) incorporated in non-ionic surfactant vesicles (niosomes) using magnetic force microscopy (MFM). After a simple specimen preparation, i.e., by putting a drop of solution containing MNPs-loaded niosomes on flat substrates, topography and MFM phase images are collected. To attempt the quantification of the diameter of entrapped MNPs, the method is calibrated on the sole MNPs deposited on the same substrates by analyzing the MFM signal as a function of the MNP diameter (at fixed tip-sample distance) and of the tip-sample distance (for selected MNPs). After calibration, the effective diameter of the MNPs entrapped in some niosomes is quantitatively deduced from MFM images.

36 MATERIALS SCIENCE↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Hard-x-ray phase-imaging microscopy using the self-imaging phenomenon of a transmission grating

We report on a hard-x-ray imaging microscope consisting of a lens, a sample, and a transmission grating. After the theoretical framework of self-imaging phenomenon by the grating in the system is presented, equations for the electric field on the image plane are derived for ideal and real lenses and an equation for the intensity on the image plane for partially coherent illumination is derived. The equations are simple and similar to those applying to a projection microscope consisting of a transmission grating except that there is no defocusing effect, regardless of whether the grating is in front of or behind the lens. This means that x-ray phase-imaging microscopy can be done without the defocusing effect. It is also shown that, by resolving the self-image on the image plane, high-sensitive x-ray phase-imaging microscopy can be attained without degradation in the spatial resolution due to diffraction by the grating. Experimental results obtained using partially coherent illumination from a synchrotron x-ray source confirm that hard-x-ray phase-imaging microscopy can be quantitatively performed with high sensitivity and without the spatial resolution degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-26: The CT Compatibility of a Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer

Purpose: To examine CT metal image artifact from a novel direction-modulated brachytherapy (DMBT) tandem applicator (95% tungsten) for cervical cancer using a commercially available orthopedic metal artifact reduction (O-MAR) algorithm. Comparison to a conventional stainless steel applicator is also performed. Methods: Each applicator was placed in a water-filled phantom resembling the female pelvis and scanned in a Philips Brilliance 16-slice CT scanner using two pelvis protocols: a typical clinical protocol (120kVp, 16×0.75mm collimation, 0.692 pitch, 1.0s rotation, 350mm field of view (FOV), 600mAs, 1.5mm slices) and a protocol with a higher kVp and mAs setting useful for larger patients (140kVp, 16×0.75mm collimation, 0.688 pitch, 1.5s rotation, 350mm FOV, 870mAs, 1.5mm slices). Images of each tandem were acquired with and without the application of the O-MAR algorithm. Baseline scans of the phantom (no applicator) were also collected. CT numbers were quantified at distances from 5 to 30 mm away from the applicator’s edge (in increments of 5mm) using measurements at eight angles around the applicator, on three consecutive slices. Results: While the presence of both applicators degraded image quality, the DMBT applicator resulted in larger streaking artifacts and dark areas in the image compared to the stainless steel applicator. Application of the O-MAR algorithm improved all acquired images, both visually and quantitatively. The use of low and high kVp and mAs settings (120 kVp/600mAs and 140 kVp/870mAs) in conjunction with the O-MAR algorithm lead to similar CT numbers in the vicinity of the applicator and a similar reduction of the induced metal artifact. Conclusion: This work indicated that metal artifacts induced by the DMBT and the stainless steel applicator are greatly reduced when using the O-MAR algorithm, leading to better quality phantom images. The use of a high dose protocol provided similar improvements in metal artifacts compared to the clinical protocol.

60 APPLIED LIFE SCIENCES↗

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

43 PARTICLE ACCELERATORS↗

Understanding structure-processing relationships in metal additive manufacturing via featurization of microstructural images

Understanding and predicting accurate property-structure-processing relationships for additively manufactured components is important for both forward and inverse design of robust, reliable parts and assemblies. While direct mapping of process parameters to properties is sometimes plausible, it is often rendered difficult due to poor microstructural control. Exploring the direct relationship between processing conditions and microstructural features can thus provide significant physical insights and aid the overall design process. Here, in this study, we develop an automated high-throughput framework to simulate an uncertainty-aware additive manufacturing (AM) process, characterize microstructural images, and extract meaningful features/descriptors. A kinetic Monte Carlo (KMC) based model of the AM process is used to simulate microstructural evolution for a diverse set of experimentally relevant processing conditions. We perform a parametric study to explore the relationship between microstructural features and processing conditions. Our results indicate that a many-to-one mapping can exist between processing conditions and typical descriptors; therefore, multiple descriptors are thus necessary to unambiguously represent microstructural images. Our work provides crucial quantitative and qualitative in-formation that would aid in the selection of features for microstructural images. Featurized microstructures could then be utilized to build data-driven models for predictive control of microstructures and thereby properties of additively manufactured components.

36 MATERIALS SCIENCE↗

Improved frame-based estimation of head motion in PET brain imaging

Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.

60 APPLIED LIFE SCIENCES↗

Software techniques for image processing

The present paper describes several software techniques that can be used to get the 'most' out of an image without destroying or adding any information. A simple overview is given of a general image-processing system, a number of systems in current use are listed, and three types of processing tasks are delineated: image diagnostics, subjective enhancement, and quantitative restoration. Examples of each of these types are discussed in some detail, including histogram, differences, and Fourier analysis for image diagnostics; contrast stretching, edge enhancement, and pseudocolor displays for subjective enhancement; and photometric correction, contouring, and geometric correction for quantitative restoration.

Klinglesmith, D. A.↗

SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion.

60 APPLIED LIFE SCIENCES↗

Chemical Imaging with Cluster Ion Beams and Lasers

The objective of this Department of Energy project has been to create a novel nanoscale three-dimensional molecule-specific imaging capability for characterization of a wide range of materials. Specific accomplishments are (1) demonstrated the generality of strong field ionization using femtosecond IR pulsed lasers to post-ionize sputtered molecules with the least amount of induced fragmentation, (2) constructed a novel multi-pass optic to more effectively sample the ablation plume created by the cluster ion beam, (3) utilized the chemistry of gas cluster ion beams containing 1000 – 10000 species to improve desorption ionization efficiency and probe the mechanism of this phenomenon using SFI, (4) for the first time, allowed images to be acquired quantitatively by separating the desorption step from the ionization step and characterizing complex multicomponent and multilayer structures. A critical part of this research has been to (1) demonstrate the unique capabilities of our technology by unraveling the architecture of complex aerosol particles with heterogeneous in-depth compositions and (2) to reveal the distribution of hydrocarbons and long chain fatty acids in b. braunii algal colonies at the single cell level, and elucidate the mechanism of hydrocarbon excretion. In general this major jump in 3-dimensional imaging capability is leading to applications in many areas of energy-related research that have heretofore remained insoluble.

3-dimensional chemical imaging↗