Search NASA⌕ Search

SEARCH · Search NASA

Results for “source selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Numerical solution of strong radiation gasdynamic interactions in a hydrogen-seedant mixture

Theoretical and experimental results are provided for the absorption of laser energy by a gas flow. A two-dimensional numerical model described the temperature field, fluid dynamics, variable absorptivity and gas dynamics. The model was tested using a hydrogen-seedant mixture injected with 10.6 micron laser radiation. The laser mix was selected to allow reduced temperature gradients and energy source terms. It was found possible, by varying parameters such as the laser power and flash pressure, to precisely position the peak absorptance region in higher speed flows. More refined models are being tested to achieve accurate absorptance predictions in flows below Mach 0.0001.

Merkle, C. L.↗

The complete sample of 1 Jansky BL Lacertae objects. I - Summary properties

The first well-defined, homogeneous radio sample of 34 BL Lac objects selected from a large-area survey of sources brighter than 1 Jy at 5 GHz is presented. Extensive optical spectroscopy reveals weak emission lines in roughly 3/4 of the 34 BL Lac objects in the sample. Optical imaging reveals that the nearby BL Lac objects are not stellar, and that the surface brightness distribution of the surrounding fuzz is consistent with the host galaxies being bright ellipticals. The results suggest that gravitational lensing may affect three of the 17 high-redshift BL Lac objects in the sample. The observations do not support a microlensing scenario for the low-redshift objects.

Stickel, M.↗

Interstellar medium continuum, autoionization, and line absorption in the extreme ultraviolet

We provide a new estimate of the effective absorption cross section of the interstellar medium at extreme ultraviolet wavelengths. The cross section for neutral helium is discussed in detail. Two spectral features of interstellar neutral helium, the 504 A ionization edge and the autoionization resonance feature at 206 A, are detectable with existing instrumentation. Measurements of the autoionization feature in continuum sources will provide a direct estimate of the intervening neutral helium column; in many cases this will be the only method to obtain this parameter. Although continuum metal opacities are negligible at wavelengths greater than 50 A we find that metal line features should be detectable in continuum sources with high signal to noise observations. A selection of some of the most prominent lines expected is provided.

Rumph, Todd↗

Electroencephalogram (EEG) and Magnetoencephalogram (MEG) as Tools for Evaluation of Cognitive Function

We have developed computerized analysis and display techniques to help identify the origins of visually evoked scalped potentials (VESP). The potentials are recorded simultaneously from many electrodes (usually 40 to 48) spaced over the region of the scalp where appreciable evoked potentials are found in response to particular stimulus. Contour mapping algorithms are then used to display the time behavior of equipotential surfaces on the scalp during the VESP. We then use an optimization technique to select the parameters of arrays of current dipole sources within the model until the model equipotential field distribution closely fits the measured data. Computer graphics are then used to display, as a movie, the actual and model scalp potential fields and the parameters of the dipole generators within the model head during the course of VESP activity. We have devised reaction time tests that involve potentially separable stages of cognitive processing and utilize stimuli that produce measurable cognition-related features in the late component of the evoked potential. We have used these techniques to determine the loci in the brain where known cognition-related features in the evoked potential are generated and we have explored the extent to which each of these features can be related to the reaction time tasks. We have also examined the temporal-spatial aspects of their cerebral involvement. Our current work is planned to characterize the age-related changes in the processes performed by such sources. We also use a neuromagnetometer to measure the evoked magnetic fields in similar circumstances; we will discuss the relative merits of the two methodologies.

Fender, Derek H.↗

Ground-Based Correlates of Solar Irradiance Variation

Ground-based instruments cannot directly measure solar irradiance variability at the 0.1% level at which it occurs because of the earth's atmosphere. However, many forms of ground-based solar observations correlate well with solar irradiance variations, and this fact has been used to construct facular-sunspot models which can explain about 90% of the variance of total solar irradiance as observed by spacecraft radiometers. It is not yet clear whether remaining discrepancies are observational or require additional sources in the model. This paper is a selective review of the current status of the use of ground-based data to understand spacecraft observations of solar irradiance and to apply this understanding to periods before space-based measurements were available. New results from the extension of the histogram analysis of NASA/NSO spectromagnetograph observations (Jones et al., 2000, ApJ529, 1070) to the period from Nov. 1992 to Sep. 2000 are reported which confirm that strong mixed polarity magnetic regions (quiet network) are not significantly correlated with total solar irradiance and which show an unexplained linear trend in the residuals of a multiple regression.

Jones, Harrison P.↗

Coronal Activity in Low-Mass Pre-Main Sequence Stars: NGC 2264

We present the preliminary results of an analysis of ROSAT images in the region of the populous young (age approx. 3 Myr) star-forming region NGC 2264. The cluster was imaged with the ROSAT HRI in two sets of pointings -- one set near the central region of the cluster, centered on the star LW Mon, and the other set in the southern part of the cluster, centered near the star V428 Mon, just south of the Cone Nebula. In total 113 unique X-ray sources have been identified in the ROSAT images with signal-to-noise ratios greater than 3. The limiting luminosities (log Lx(ergs/sec)) for 3-sigma detections are estimated to be 30.18, 30.23, and 30.08 for the northern field, southern field, and overlap region between the two fields respectively. Extensive optical photometry, classification spectroscopy, and proper motions, obtained from recent ground-based surveys of this region, were used to identify the most likely optical counterpart to each X-ray source. Although most of our X-ray selected sample appears to be associated with NGC 2264 members, we find that the vast majority of the cluster membership was undetected in the ROSAT HRI survey. The X-ray cumulative luminosity function for solar-mass stars in NGC 2264 shows that most of the low-mass members probably have X-ray luminosities similar to those seen for the X-ray brightest members of older clusters such as IC 2391/IC 2602 (age approx. 50 Myr) and the Pleiades (age approx. 100 Myr). This research was funded in part by the SAO Summer Intern Program and NASA grant NAG5-8120.

Tebbe, H. J.↗

Full Scale Rotor Aeroacoustic Predictions and the Link to Model Scale Rotor Data

The NASA Aeroacoustic Prediction System (NAPS) is used to establish a link between model-scale and full-scale rotor predictions and is partially validated against measured wind tunnel and flight aeroacoustic data. The prediction approach of NAPS couples a comprehensive rotorcraft analysis with acoustic source noise and propagation codes. The comprehensive analysis selected for this study is CAMRAD-II, which provides the performance/trim/wake solution for a given rotor or flight condition. The post-trim capabilities of CAMRAD-II are used to compute high-resolution sectional airloads for the acoustic tone noise analysis, WOPMOD. The tone noise is propagated to observers on the ground with the propagation code, RNM (Rotor Noise Model). Aeroacoustic predictions are made with NAPS for an isolated rotor and compared to results of the second Harmonic Aeroacoustic Rotor Test (HART-II) program, which tested a 40% dynamically and Mach-scaled BO-105 main rotor at the DNW. The NAPS is validated with comparisons for three rotor conditions: a baseline condition and two Higher Harmonic Control (HHC) conditions. To establish a link between model and full-scale rotor predictions, a full-scale BO-105 main rotor input deck for NAPS is created from the 40% scale rotor input deck. The full-scale isolated rotor predictions are then compared to the model predictions. The comparisons include aerodynamic loading, acoustic levels, and acoustic pressure time histories for each of the three conditions. With this link established, full-scale predictions are made for a range of descent flight conditions and compared with measured trends from the recent Rotorcraft Operational Noise Abatement Procedures (RONAP) flight test conducted by DLR and ONERA. Additionally, the effectiveness of two HHC conditions from the HART-II program is demonstrated for the full-scale rotor in flight.

Boyd, D. Douglas, Jr.↗

The scope and direction of health informatics

Health Informatics (HI) is a dynamic discipline based on the medical sciences, information sciences, and cognitive sciences. Its domain can broadly be defined as medical information management. The purpose of this paper is to provide an overview of this domain, discuss the current "state of the art," and indicate the likely growth areas for health informatics. The sources of information used in this paper are selected publications from the literature of Health Informatics, HI 5300: Introduction to Health Informatics, which is a course from the Department of Health Informatics at the University of Texas Houston Health Sciences Center, and the author's personal experience in practicing telemedicine and implementing an electronic medical record at the NASA-Johnson Space Center. The conclusion is that the direction of Health Informatics is in the direction of data management, transfer, and representation via electronic medical records and the Internet.

Medical Informatics Applications↗

Spirosymplokos deltaeiberi nov. gen., nov. sp.: variable-diameter composite spirochete from microbial mats

Large (up to 100 micrometers long), loosely coiled, free-living spirochetes with variable diameters (from 0.4 to 3 micrometers in the same cell) were seen at least 40 times between August 1990 and January 1993. These spirochetes were observed in mud water and enrichment media from highly specific habitats in intertidal evaporite flats at three disjunct localities, one in Spain and two in Mexico. All three are sites of commercial saltworks. Associated with Microcoleus chthonoplastes the large spirochetes from Spain display phototaxis and a composite organization. Shorter and smaller-diameter spirochetes are seen inside both healthy and spent periplasm of larger ones. Small spirochetes attached to large ones have been observed live. From two to twelve spirochete protoplasmic cylinders were seen inside a single common outer membrane. A distinctive granulated cytoplasm in which the granules are of similar diameter (20-32 nanometers) to that of the flagella (26 nanometers) was present. Granule diameters were measured in thin section and in negatively-stained whole-mount preparations. Based on their ultrastructure, large size, variable diameter, number of flagella (3 to 6), and phototactic behavior these unique spirochetes are formally named Spirosymplokos deltaeiberi. Under anoxic (or low oxygen) conditions they formed blooms in mixed culture in media selective for spirochetes. Cellobiose was the major carbon source in 80% seawater, the antibiotic rifampicin was added, mat from the original field site was present and tubes were incubated in the light at from 18-31 degrees C. Within 1-2 weeks populations of the large spirochete developed at 25 degrees C but they could not be transferred to fresh medium.

Non-NASA Center↗

SCARLET Photovoltaic Concentrator Array Selected for Flight Under NASA's New Millennium Program

The NASA Lewis Research Center continues to demonstrate its expertise in the development and implementation of advanced space power systems. For example, during the past year, the NASA New Millennium Program selected the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) photovoltaic array as the power system for its Deep Space-1 (DS-1) mission. This Jet Propulsion Laboratory (JPL) managed DS-1 mission, which represents the first operational flight of a photovoltaic concentrator array, will provide a baseline for the use of this technology in a variety of future government and commercial applications. SCARLET is a joint NASA Lewis/Ballistic Missile Defense Organization program to develop advanced photovoltaic array technology that uses a unique refractive concentrator design to focus sunlight onto a line of photovoltaic cells located below the optical element. The general concept is based on previous work conducted at Lewis under a Small Business Innovation Research (SBIR) contract with AEC-Able Engineering, Inc., for the Multiple Experiments to Earth Orbit and Return (METEOR) spacecraft. The SCARLET II design selected by the New Millennium Program is a direct adaptation of the smaller SCARLET I array built for METEOR. Even though SCARLET I was lost during a launch failure in October 1995, the hardware (designed, built, and flight qualified within 6 months) provided invaluable information and experience that led to the selection of this technology as the primary power source for DS-1.

Piszczor, Michael F., Jr.↗

Bright field illumination system

A Bright Field Illumination system for inspecting a range of characteristically different kinds of defects, depressions, and ridges in a selected material surface. The system has an illumination source placed near a first focus of an elliptical reflector. In addition, a camera facing the inspected area is placed near the illumination source and the first focus. The second focus of the elliptical reflector is located at a distance approximately twice the elliptical reflector's distance above the inspected surface. The elliptical reflector directs the light from the source onto the inspected surface. Due to the shape of the elliptical reflector, light that is specularly reflected from the inspected surface is directed into the camera is which located at the position of the reflected second focus of the ellipse. This system creates a brightly lighted background field against which damage sites appear as high contrast dark objects which can be easily detected by a person or an automated inspection system. In addition, the Bright Field Illumination system and method can be used in combination with a vision inspection system providing for multiplexed illumination and data handling of multiple kinds of surface characteristics including abrupt and gradual surface variations and differences between measured characteristics of different kinds and prior instruments.

Huber, Edward D.↗

The Scope and Direction of Health Informatics

Health Informatics (HI) is a dynamic discipline based upon the medical sciences, information sciences, and cognitive sciences. Its domain is can broadly be defined as medical information management. The purpose of this paper is to provide an overview of this domain, discuss the current "state of the art" , and indicate the likely growth areas for health informatics. The sources of information utilized in this paper are selected publications from the literature of Health Informatics, HI 5300: Introduction to Health Informatics, which is a course from the Department of Health Informatics at the University of Texas Houston Health Sciences Center, and the author's personal experience in practicing telemedicine and implementing an electronic medical record at the NASA Johnson Space Center. The conclusion is that the direction of Health Informatics is in the direction of data management, transfer, and representation via electronic medical records and the Internet.

McGinnis, Patrick J.↗

Improvement of Aerosol Optical Depth Retrieval over Hong Kong from a Geostationary Meteorological Satellite Using Critical Reflectance with Background Optical Depth Correction

Despite continuous efforts to retrieve aerosol optical depth (AOD) using a conventional 5-channelmeteorological imager in geostationary orbit, the accuracy in urban areas has been poorer than other areas primarily due to complex urban surface properties and mixed aerosol types from different emission sources. The two largest error sources in aerosol retrieval have been aerosol type selection and surface reflectance. In selecting the aerosol type from a single visible channel, the season-dependent aerosol optical properties were adopted from longterm measurements of Aerosol Robotic Network (AERONET) sun-photometers. With the aerosol optical properties obtained fromthe AERONET inversion data, look-up tableswere calculated by using a radiative transfer code: the Second Simulation of the Satellite Signal in the Solar Spectrum (6S). Surface reflectance was estimated using the clear sky composite method, awidely used technique for geostationary retrievals. Over East Asia, the AOD retrieved from the Meteorological Imager showed good agreement, although the values were affected by cloud contamination errors. However, the conventional retrieval of the AOD over Hong Kong was largely underestimated due to the lack of information on the aerosol type and surface properties. To detect spatial and temporal variation of aerosol type over the area, the critical reflectance method, a technique to retrieve single scattering albedo (SSA), was applied. Additionally, the background aerosol effect was corrected to improve the accuracy of the surface reflectance over Hong Kong. The AOD retrieved froma modified algorithmwas compared to the collocated data measured by AERONET in Hong Kong. The comparison showed that the new aerosol type selection using the critical reflectance and the corrected surface reflectance significantly improved the accuracy of AODs in Hong Kong areas,with a correlation coefficient increase from0.65 to 0.76 and a regression line change from τMI [basic algorithm] = 0.41τAERONET + 0.16 to τMI [new algorithm] = 0.70τAERONET + 0.01.

aerosols↗

Ambient monitoring to inform the protection of beneficial uses and achieve water quality goals in Sinclair and Dyes Inlets, Puget Sound, WA

Currently discharge limits enforced under the Clean Water Act are focused on meeting water quality standards at the end of the pipe and environmental performance is measured based on meeting the discharge limits; but meeting discharge limits has very little to do with achieving water quality goals for coastal and estuarine ecosystems. Therefore, an effective monitoring and assessment program is needed to assess continuous process improvement, evaluate the ecological conditions, and provide metrics that can inform effective management of coastal and estuarine water quality. As part of an integrated Environmental Investment (ENVVEST) project for Sinclair and Dyes Inlets (ENVVEST 2006; Johnston et al. 2009) a network of monitoring stations was established to characterize environmental conditions, assess potential impacts, and establish environmental quality trends within the Inlets. Water, sediment, and biota monitoring locations were selected that were co-located near suspected sources (industrial, waste water, and stormwater outfalls; marinas, stream mouths, and other sources) or were representative of ambient marine and nearshore conditions. Water column stations and effluents from industrial outfalls were sampled seasonally for trace metals (Cd, Cr, Cu, Hg, Pb, and Zn) using analytical procedures appropriate for seawater (Strivens, Brandenberger and Johnston, 2018), conventional parameters (salinity, dissolved and total organic carbon, total and suspended solids, dissolved O2, pH, turbidity, NO2+NO3, NH4, N, and P), and toxicity. Effluent and water column toxicity tests included mysid shrimp (Americamysis bahia) 96 hr survival, sand dollar (Dendraster excentricus) or purple sea urchin (Strongylocentrotus purpuratus) 96 hr embryo development, QwikLite – dinoflagellate (Pyrocystis lunula) 24 hr bioluminescence response, mussel larvae (Mytilus sp.) 48 hr larvae survival and development, and kelp (Macrocystis pyrifera) 48 hr growth and germination. Additionally, indigenous mussels (Mytilis spp.) were sampled biennially for contaminant residues of metals, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), lipid content, and stable isotopes of C and N. The mussel data were compared to benchmarks of ecological effects (Johnston et al. 2007, Applied Biomonitoring 2009), samples obtained from a local seafood market harvested from Penn Cove on Whidbey Island (PKPLPC), and data from the national mussel watch status and trends monitoring program (Kimbrough et al. 2008). Results from 2009-2016 showed that dissolved metals nearly always met water quality standards and that water quality in Navy nearshore areas appeared to improve after best management practices (BMPs) for industrial process improvements (US Navy 2012) were completed in Sept. 2013 (Figure 1). In general, toxicity from exposure to whole effluent samples was not observed and ambient water samples were not toxic to test organisms, except that ambient toxicity was only observed during the presence of algal blooms which showed that toxicity was highly correlated with the abundance of the toxic algae Gymnodinium splendens (Rosen et al. 2009). Overall, mussel tissue residues were below benchmarks at most locations (Figure 2), however there were locations that had elevated levels of PAHs, PCBs, Hg, and Cu. Results from the monitoring provide metrics that are being used to assess progress toward meeting environmental quality goals for the watershed.

ENVVEST, PSEMP↗

System and method for in situ volumetric sensing of 3D cure state of resin being used in an additive manufacturing system

An in situ cure monitoring control system for use with a volumetric three dimensional (3D) printing system, wherein the volumetric 3D system includes a container defining a build volume, the container includes a photocurable resist used for making a 3D part, and the resist is responsive to an optical curing beam from a light source, which is controlled by a controller, and which is passed through the resist. The cure monitoring control system includes an optical signal source which generates optical signals having a wavelength selected in relation to a characteristic of the resist, and directed to pass through the build volume. A detector detects the optical signals and generates output signals in accordance therewith. Software monitors the output signals and uses the output signals to modify the curing beam to help optimize curing of the resist.

Panas, Robert Matthew↗

ILLICIT TRANSIT INTERDICTION GLOBAL ANALYSIS

This study aims to enhance the security of radioactive materials during transport by analyzing commonalities in cargo thefts conducted by non-state groups such as thieves and terrorists. This research focuses on identifying patterns and trends in the methods used to steal high-value cargo, with the goal of applying these insights to improve transport security of radioactive materials. Key questions addressed include the frequency of specific tools, techniques, and insider involvement in thefts, as well as the use of weapons, electronic jamming equipment, and specialized tools. Findings will inform security design improvements and industry practices to mitigate vulnerabilities. The study involves a comprehensive review of literature and case studies, utilizing data sources from 2018 to 2023. Articles will be selected based on their relevance to thefts of valuable cargo in transit, with a focus on incidents involving non-state actors. The methodology will include statistical and inferential analysis to identify trends, with results visualized through pie charts, frequency analyses, and terrain maps. The discussion will highlight the implications of findings and provide actionable recommendations for strengthening security measures. Limitations such as data availability and reporting inconsistencies will be acknowledged. Suggestions for future improvements will be constructed using existing case studies and expert feedback. The study’s outcomes aim to raise awareness within the industry, inform policy decisions, and enhance security protocols for radioactive material transport. Metrics for impact include the potential publication of findings, presentations at conferences to raise awareness, and the subsequent actions taken by stakeholders based on the research. By identifying trends and vulnerabilities and suggesting improvements, this research contributes to preventing the illicit use of nuclear and radiological materials.

Zineddin, Dr. Z. [ORNL] (ORCID:0009000848740725)↗

No evidence for radio-quiet BL Lacertae objects

Using a large, flux-limited sample of faint X-ray sources, a search has been conducted for radio-quiet BL Lacertae objects. None has been found. Thirty-two X-ray-selected BL Lac objects and BL Lac candidates have been found within the sources of the Einstein Medium Sensitivity Survey (EMSS). Thirty-one of these have been observed with the VLA and all have been detected at 5 GHz. While the optical magnitudes of the EMSS BL Lac objects range from 17 to 20.8, their radio-to-optical spectral indices occupy a very small range. The very bright X-ray-selected BL Lac objects like PKS 2155-304 and Markarian 501 have similar range values. Therefore, unlike the clear dichotomy between radio-loud quasars and radio-quiet QSOs, there is no evidence for two populations of Lacertids distinguished by radio loudness.

Stocke, John T.↗

Modular Soft X-Ray Emission Spectrograph

We have been developing the Hettrick-Underwood type soft x-ray spectrograph for over a decade. This optical design uses one spherical mirror for focusing x-rays onto the CCD detector and a set of variable line-spacing gratings for energy analysis. Unlike the previous effort carried out at the ALS, what we have achieved in the current design is to incorporate the concept of modularity. The model of spectrograph is shown below. It contains three major components: the optics chamber and downstream section (detector plus driving mechanism using a swing arm pivoted at the grating location, see figure) for inside and outside order (translation stage without swing arm, not shown here). Inside order design is often used when source size is larger than the detector pixel resolution, while the outside order is used when source size is smaller than the detector pixel resolution. Irrespective to which order is selected, there is no change in the mechanism of optics chamber. The location of optics chamber relative to the source and detector can also be changed to optimize the energy resolution at target photon energy. The incident angles on mirror and gratings can be varied, in conjunction with the grating line densities, to balance the resolution and throughput. The internal components of optics chamber are also modular and changing the dimension of optics can be done by using different holders. The modularity not only greatly reduces the design and assembling effort, but also offers the cost benefit. Although the cost of this type of spectrograph is expected to be higher than XES350, it is still significant lower than the one-of-the-kind design used at every synchrotron facilities. The unique flexibility and modularity not only allows the users to tailor the design of spectrograph for the characteristic of their sources, but also to have cost down in standardizing the fabrication parts.

Hussain, Zahid↗