Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Measurements from an Aerial Vehicle: A New Tool for Planetary Exploration

Aerial vehicles fill a unique planetary science measurement gap, that of regional-scale, near-surface observation, while providing a fresh perspective for potential discovery. Aerial vehicles used in planetary exploration bridge the scale and resolution measurement gaps between orbiters (global perspective with limited spatial resolution) and landers (local perspective with high spatial resolution) thus complementing and extending orbital and landed measurements. Planetary aerial vehicles can also survey scientifically interesting terrain that is inaccessible or hazardous to landed missions. The use of aerial assets for performing observations on Mars, Titan, or Venus will enable direct measurements and direct follow-ons to recent discoveries. Aerial vehicles can be used for remote sensing of the interior, surface and atmosphere of Mars, Venus and Titan. Types of aerial vehicles considered are airplane "heavier than air" and airships and balloons "lighter than air". Interdependencies between the science measurements, science goals and objectives, and platform implementation illustrate how the proper balance of science, engineering, and cost, can be achieved to allow for a successful mission. Classification of measurement types along with how those measurements resolve science questions and how these instruments are accommodated within the mission context are discussed.

Wright, Henry S.↗

First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

60 APPLIED LIFE SCIENCES↗

Pulse compressor with aberration correction

In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete pulse compressor. The simulations reveal that the mirror pulse compressor can reduce the temporal spread of UEDs and DTEMs to the sub-100 femtosecond level for practical electron bunch sizes. EOI’s pulse compressors can be designed and built to attach to different types of UEDs and DTEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales to advance material science research in the field of nanotechnology as well as biomedical research.

47 OTHER INSTRUMENTATION↗

Super Resolution Digital Image Correlation (SR-DIC): an Alternative to Image Stitching at High Magnifications

Abstract Background High-resolution Digital Image Correlation (DIC) measurements have previously been produced by stitching of neighboring images, which often requires short working distances. Separately, the image processing community has developed super resolution (SR) imaging techniques, which improve resolution by combining multiple overlapping images. Objective This work investigates the novel pairing of super resolution with digital image correlation, as an alternative method to produce high-resolution full-field strain measurements. Methods First, an image reconstruction test is performed, comparing the ability of three previously published SR algorithms to replicate a high-resolution image. Second, an applied translation is compared against DIC measurement using both low- and super-resolution images. Third, a ring sample is mechanically deformed and DIC strain measurements from low- and super-resolution images are compared. Results SR measurements show improvements compared to low-resolution images, although they do not perfectly replicate the high-resolution image. SR-DIC demonstrates reduced error and improved confidence in measuring rigid body translation when compared to low resolution alternatives, and it also shows improvement in spatial resolution for strain measurements of ring deformation. Conclusions Super resolution imaging can be effectively paired with Digital Image Correlation, offering improved spatial resolution, reduced error, and increased measurement confidence.

Hansen, R. S.↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projected precipitation changes within the Great Lakes and Western Lake Erie Basin: a multi‐model analysis of intensity and seasonality

ABSTRACT The Great Lakes region encompasses the largest freshwater lake network in the world and supports a diverse network of agriculture, transportation, and tourism. Recently, Lake Erie has experienced increased hypoxia events, which have been attributed to agricultural practices and changes in run‐off. Here we examine the projected changes in extreme precipitation events to address concerns regarding regional agriculture, surface run‐off, and subsequent water quality. Precipitation projections within the overall Great Lakes Basin and the Western Lake Erie Basin subregion are examined using climate model simulations of varying spatial resolutions to understand historical precipitation and projected future precipitation. We develop three model ensembles for the historical period (1980–1999) and the mid‐century (2041–2060) that cover a range of spatial resolutions and future emissions scenarios, including: (1) 12 global model members from the fifth Climate Model Intercomparison Project ( CMIP5 ) using Representative Concentration Pathway ( RCP ) 8.5, (2) ten regional climate model ( RCM ) members from the North American Regional Climate Change Assessment Program driven by CMIP3 global models using the A2 emissions scenario, and (3) two high resolution RCM simulations ( RCM4 ) driven by CMIP5 global models using the RCP 8.5 scenario. For the historical period, all model ensembles overestimate winter and spring precipitation, and many of the models simulate a summer drying that is not observed. At mid‐century, most of the models predict a 10–20% increase in precipitation depending on the time of year. Daily probability distribution functions from three model ensembles reveal spring seasonal increases in high precipitation event probabilities when compared to the historical period, suggesting an increase in the frequency of high intensity precipitation at mid‐century. Overall, the presence of lakes or higher spatial resolution does not ensure improved representation of historical processes, and more complex interactions between large‐scale dynamics, local feedbacks, and physical parameterizations drive the model spread.

Basile, Samantha J.↗

GLASS daytime all-wave net radiation product: Algorithm development and preliminary validation

Mapping surface all-wave net radiation (R n ) is critically needed for various applications. Several existing R n products from numerical models and satellite observations have coarse spatial resolutions and their accuracies may not meet the requirements of land applications. In this study, we develop the Global LAnd Surface Satellite (GLASS) daytime R n product at a 5 km spatial resolution. Its algorithm for converting shortwave radiation to all-wave net radiation using the Multivariate Adaptive Regression Splines (MARS) model is determined after comparison with three other algorithms. The validation of the GLASS R n product based on high-quality in situ measurements in the United States shows a coefficient of determination value of 0.879, an average root mean square error value of 31.61 Wm -2 , and an average bias of 17.59 Wm -2 . Furthermore, we also compare our product/algorithm with another satellite product (CERES-SYN) and two reanalysis products (MERRA and JRA55), and find that the accuracy of the much higher spatial resolution GLASS R n product is satisfactory. The GLASS R n product from 2000 to the present is operational and freely available to the public.

58 GEOSCIENCES↗

Cross-Scale Molecular Analysis of Chemical Heterogeneity in Shale Rocks

The organic and mineralogical heterogeneity in shale at micrometer and nanometer spatial scales contributes to the quality of gas reserves, gas flow mechanisms and gas production. Here, we demonstrate two molecular imaging approaches based on infrared spectroscopy to obtain mineral and kerogen information at these mesoscale spatial resolutions in large-sized shale rock samples. The first method is a modified microscopic attenuated total reflectance measurement that utilizes a large germanium hemisphere combined with a focal plane array detector to rapidly capture chemical images of shale rock surfaces spanning hundreds of micrometers with micrometer spatial resolution. The second method, synchrotron infrared nano-spectroscopy, utilizes a metallic atomic force microscope tip to obtain chemical images of micrometer dimensions but with nanometer spatial resolution. This chemically "deconvoluted" imaging at the nano-pore scale is then used to build a machine learning model to generate a molecular distribution map across scales with a spatial span of 1000 times, which enables high-throughput geochemical characterization in greater details across the nano-pore and micro-grain scales and allows us to identify co-localization of mineral phases with chemically distinct organics and even with gas phase sorbents. Finally, this characterization is fundamental to understand mineral and organic compositions affecting the behavior of shales.

04 OIL SHALES AND TAR SANDS↗

The structure of liquid water up to 360 MPa from x-ray diffraction measurements using a high Q-range and from molecular simulation

X-ray diffraction measurements of liquid water are reported at pressures up to 360 MPa corresponding to a density of 0.0373 molecules per Å{sup 3}. The measurements were conducted at a spatial resolution corresponding to Q{sub max} = 16 Å{sup −1}. The method of data analysis and measurement in this study follows the earlier benchmark results reported for water under ambient conditions having a density of 0.0333 molecules per Å{sup 3} and Q{sub max} = 20 Å{sup −1} [J. Chem. Phys. 138, 074506 (2013)] and at 70 °C having a density of 0.0327 molecules per Å{sup 3} and Q{sub max} = 20 Å{sup −1} [J. Chem. Phys. 141, 214507 (2014)]. The structure of water is very different at these three different T and P state points and thus they provide the basis for evaluating the fidelity of molecular simulation. Measurements show that at 360 MPa, the 4 waters residing in the region between 2.3 and 3 Å are nearly unchanged: the peak position, shape, and coordination number are nearly identical to their values under ambient conditions. However, in the region above 3 Å, large structural changes occur with the collapse of the well-defined 2nd shell and shifting of higher shells to shorter distances. The measured structure is compared to simulated structure using intermolecular potentials described by both first-principles methods (revPBE-D3) and classical potentials (TIP4P/2005, MB-pol, and mW). The DFT-based, revPBE-D3, method and the many-body empirical potential model, MB-pol, provide the best overall representation of the ambient, high-temperature, and high-pressure data. The revPBE-D3, MB-pol, and the TIP4P/2005 models capture the densification mechanism, whereby the non-bonded 5th nearest neighbor molecule, which partially encroaches the 1st shell at ambient pressure, is pushed further into the local tetrahedral arrangement at higher pressures by the more distant molecules filling the void space in the network between the 1st and 2nd shells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous measurements of kinetic and scalar energy spectrum time evolution in the Richtmyer–Meshkov instability upon reshock

The Richtmyer–Meshkov instability (Richtmyer, Commun. Pure Appl. Maths , vol. 13, issue 2, 1960, pp. 297–319; Meshkov, Fluid Dyn. , vol. 4, issue 5, 1972, pp. 101–104) of a twice-shocked gas interface is studied using both high spatial resolution single-shot (SS) and lower spatial resolution, time-resolved, high-speed (HS) simultaneous planar laser-induced fluorescence and particle image velocimetry in the Wisconsin Shock Tube Laboratory's vertical shock tube. The initial condition (IC) is a shear layer with broadband diffuse perturbations at the interface between a helium–acetone mixture and argon. This IC is accelerated by a shock of nominal strength Mach number $M = 1.75$ , and then accelerated again by the transmitted shock that reflects off the end wall of the tube. An ensemble of experiments is analysed after reshock while the interface mixing width grows linearly with time. The kinetic and scalar energy spectra and the terms of their evolution equation are calculated and compared between SS and HS experiments. The inertial range scaling of the scalar power spectrum is found to follow Gibson's relation (Gibson, Phys. Fluids , vol. 11, issue 11, 1968, pp. 2316–2327) as a function of Schmidt number when the effective turbulent Schmidt number is used in place of the material Schmidt number that controls equilibrium scaling. Further, the spatially integrated scalar flux follows similar behaviour observed for the kinetic energy in large eddy simulation studies by Zeng et al. ( Phys. Fluids , vol. 30, issue 6, 2018, 064106) while the spatially varying scalar flux exhibits back scatter along the centre of the mixing layer and forward energy transfer in the spike and bubble regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in solar radio astronomy

The status of the observations and interpretations of the sun's radio emission covering the entire radio spectrum from millimeter wavelengths to hectometer and kilometer wavelengths is reviewed. Emphasis is given to the progress made in solar radio physics as a result of recent advances in plasma and radiation theory. It is noted that the capability now exists of observing the sun with a spatial resolution of approximately a second of arc and a temporal resolution of about a millisecond at centimeter wavelengths and of obtaining fast multifrequency two-dimensional pictures of the sun at meter and decameter wavelengths. A summary is given of the properties of nonflaring active regions at millimeter, centimeter, and meter-decameter wavelengths. The properties of centimeter wave bursts are discussed in connection with the high spatial resolution observations. The observations of the preflare build-up of an active region are reviewed. High spatial resolution observations (a few seconds of arc to approximately 1 arcsec) are discussed, with particular attention given to the one- and two-dimensional maps of centimeter-wavelength burst sources.

Kundu, M. R.↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

Deblurring galaxy images with Tikhonov regularization on magnitude domain

Abstract We propose a regularization-based deblurring method that works efficiently for galaxy images. The spatial resolution of a ground-based telescope is generally limited by seeing conditions and is much worse than space-based telescopes. This circumstance has generated considerable research interest in the restoration of spatial resolution. Since image deblurring is a typical inverse problem and often ill-posed, solutions tend to be unstable. To obtain a stable solution, much research has adopted regularization-based methods for image deblurring, but the regularization term is not necessarily appropriate for galaxy images. Although galaxies have an exponential or Sérsic profile, the conventional regularization assumes the image profiles to behave linearly in space. The significant deviation between the assumption and real situations leads to blurring of the images and smoothing out the detailed structures. Clearly, regularization on logarithmic domain, i.e., magnitude domain, should provide a more appropriate assumption, which we explore in this study. We formulate a problem of deblurring galaxy images by an objective function with a Tikhonov regularization term on a magnitude domain. We introduce an iterative algorithm minimizing the objective function with a primal–dual splitting method. We investigate the feasibility of the proposed method using simulation and observation images. In the simulation, we blur galaxy images with a realistic point spread function and add both Gaussian and Poisson noise. For the evaluation with the observed images, we use galaxy images taken by the Subaru HSC-SSP. Both of these evaluations show that our method successfully recovers the spatial resolution of the deblurred images and significantly outperforms the conventional methods. The code is publicly available from the GitHub 〈https://github.com/kzmurata-astro/PSFdeconv_amag〉.

Murata, Kazumi↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Electron cyclotron emission quasi-optical transmission system on the HL-3 tokamak

A new quasi-optical (QO) Electron Cyclotron Emission (ECE) transmission system has been established on the HL-3 tokamak, which includes a focusing QO mirror combination and a long-distance transmission line. This system was developed to meet the requirements for poloidal spatial resolution and the high signal-to-noise ratio needed for magnetohydrodynamic (MHD) instability studies using ECE on the HL-3. The QO mirror combination was installed inside the vacuum chamber for focusing. Laboratory test results, theoretical calculations, and synthetic ECE simulation results indicate that the Gaussian beam can meet the spatial resolution requirements for the accurate measurement of the MHD instability on the q = 1/2/3 surfaces, corresponding to the poloidal mode numbers m = 3/6/9. This includes good diagnostic poloidal spatial resolution for the important 2/1 and 3/2 modes. At the front end of the transmission line, a high-efficiency mode converter was designed to transition the TE 10 mode to the HE 11 mode for input into the transmission line, with an insertion loss of less than 1.5 dB. A 30 m long-distance corrugated oversized waveguide was constructed, with transmission losses ranging from 6 to 10 dB in the 60–120 GHz range. Polarization adjustment results show that the polarization offset and geometric spatial polarization angle change consistently, which can provide a reference for polarization adjustment in other complex structured transmission lines. As a result, the newly established ECE QO transmission system will provide strong support for future physics research involving ECE on the HL-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of Satellite Imagers and Sounders for Low Earth Orbit and Technology Directions at NASA

Imagers and Sounders for Low Earth Orbit (LEO) provide fundamental global daily observations of the Earth System for scientists, researchers, and operational weather agencies. The imager provides the nominal 1-2 km spatial resolution images with global coverage in multiple spectral bands for a wide range of uses including ocean color, vegetation indices, aerosol, snow and cloud properties, and sea surface temperature. The sounder provides vertical profiles of atmospheric temperature, water vapor cloud properties, and trace gases including ozone, carbon monoxide, methane and carbon dioxide. Performance capabilities of these systems has evolved with the optical and sensing technologies of the decade. Individual detectors were incorporated on some of the first imagers and sounders that evolved to linear array technology in the '80's. Signal-to-noise constraints limited these systems to either broad spectral resolution as in the case of the imager, or low spatial resolution as in the case of the sounder. Today's area 2-dimensional large format array technology enables high spatial and high spectral resolution to be incorporated into a single instrument. This places new constraints on the design of these systems and enables new capabilities for scientists to examine the complex processes governing the Earth System.

remote sensing↗

Micro-CT at the imaging beamline P05 at PETRA III

The Imaging Beamline (IBL) P05 is operated by the Helmholtz-Zentrum Geesthacht and located at the DESY storage ring PETRA III. IBL is dedicated to X-ray full field imaging and consists of two experimental end stations. A micro tomography end station equipped for spatial resolutions down to 1 µm and a nano tomography end station for spatial resolutions down to 100 nm. The micro tomography end station is in user operation since 2013 and offers imaging with absorption contrast, phase enhanced absorption contrast and phase contrast methods. We report here on the current status and developments of the micro tomography end station including technical descriptions and show examples of research performed at P05.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗