Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Automated Vulnerability Detection for Compiled Smart Grid Software

While testing performed with proper experimental controls can provide scientifically quantifiable evidence that software does not contain unintentional vulnerabilities (bugs), it is insufficient to show that intentional vulnerabilities exist, and impractical to certify devices for the expected long lifetimes of use. For both of these needs, rigorous analysis of the software itself is essential. Automated software behavior computation applies rigorous static software analysis methods based on function extraction (FX) to compiled software to detect vulnerabilities, intentional or unintentional, and to verify critical functionality. This analysis is based on the compiled firmware, takes into account machine precision, and does not rely on heuristics or approximations early in the analysis.

99 GENERAL AND MISCELLANEOUS↗

Improving Bending Moment Measurements on Wind Turbine Blades

Full-scale fatigue testing of wind turbine blades is conducted using resonance test techniques where the blade plus additional masses is excited at its first resonance frequency to achieve the target loading amplitude. Because there is not a direct relationship between the force applied by an actuator and the bending moment, the blade is instrumented with strain gauges that are calibrated under static loading conditions to determine the sensitivity or relationship between strain and applied moment. Then, during dynamic loading the applied moment is calculated using the strain response of the structure. A similar procedure is also used in the field to measure in-service loads on turbine blades. Because wind turbine blades are complex twisted structures and the deflections are large, there is often significant cross-talk coupling in the sensitivity of strain gauges placed on the structure. Recent work has shown that a sensitivity matrix with nonzero cross terms must be employed to find constant results when a blade is subjected to both flap and lead-lag loading. However, even under controlled laboratory conditions, potential for errors of 3 percent or more in the measured moment exist when using the typical cross-talk matrix approach due to neglecting the influence of large deformations and torsion. This is particularly critical when considering a biaxial load as would be applied on the turbine or during a biaxial fatigue test. This presentation describes these results demonstrating errors made when performing current loads measurement practices on wind turbine blades in the lab and evaluating potential improvements using enhanced cross-talk matrix approaches and calibration procedures.

17 WIND ENERGY↗

Solving quasi‐static equations with the material‐point method

Summary The material‐point method models continua by following a set of unconnected material points throughout the deformation of a body. This set of points provides a Lagrangian description of the material and geometry. Information from the material points is projected onto a background grid where equations of motion are solved. The grid solution is then used to update the material points. This paper describes how to use this method to solve quasi‐static problems. The resulting discrete equations are a coupled set of nonlinear equations that are then solved with a Jacobian‐free, Newton–Krylov algorithm. The technique is illustrated by examining two problems. The first problem simulates a compact tension test and includes a model of material failure. The second problem computes effective, macroscopic properties of a polycrystalline thin film. Copyright © 2015 John Wiley & Sons, Ltd.

Sanchez, J.↗

Contact Angle Measurements Using Sessile Drop and Micro-CT Data from Six Sandstones

Numerous sessile drop and micro-computed tomography (micro-CT) studies have been conducted to quantify Geologic Carbon Storage formation wettability by measuring static contact angles (θ); however, the influence of pore geometry remains unknown. In this work, six sandstones (Bandera Brown, Berea, Bentheimer, Mt. Simon, Navajo, and Nugget) are used to measure θ using the two aforementioned experimental methods at identical testing conditions (45°C and 12.41 MPa). The range of θ measured at in situ conditions (micro-CT) exceeds those the range at ex situ (sessile drop method) conditions for all sandstones. However, when droplets with more representative in situ diameters are analyzed, θ averages show ex situ θ exceed those of in situ θ. Pore geometry does influence local θ, but the size of ex situ droplets relative to pore size appears to influence θ. This is an important to consider for future sessile drop studies used for analysis of CO 2 behavior in carbon storage reservoirs.

36 MATERIALS SCIENCE↗

GMctdospp: Description and validation of a CT dose calculation system

Purpose: To develop a Monte Carlo (MC)-based computed tomography (CT) dose estimation method with a graphical user interface with options to define almost arbitrary simulation scenarios, to make calculations sufficiently fast for comfortable handling, and to make the software free of charge for general availability to the scientific community. Methods: A framework called GMctdospp was developed to calculate phantom and patient doses with the MC method based on the EGSnrc system. A CT scanner was modeled for testing and was adapted to half-value layer, beam-shaping filter, z-profile, and tube-current modulation (TCM). To validate the implemented variance reduction techniques, depth-dose and cross-profile calculations of a static beam were compared against DOSXYZnrc/EGSnrc. Measurements for beam energies of 80 and 120 kVp at several positions of a CT dose-index (CTDI) standard phantom were compared against calculations of the created CT model. Finally, the efficiency of the adapted code was benchmarked against EGSnrc defaults. Results: The CT scanner could be modeled accurately. The developed TCM scheme was confirmed by the dose measurement. A comparison of calculations to DOSXYZnrc showed no systematic differences. Measurements in a CTDI phantom could be reproduced within 2% average, with a maximal difference of about 6%. Efficiency improvements of about six orders of magnitude were observed for larger organ structures of a chest-examination protocol in a voxelized phantom. In these cases, simulations took 25 s to achieve a statistical uncertainty of ∼0.5%. Conclusions: A fast dose-calculation system for phantoms and patients in a CT examination was developed, successfully validated, and benchmarked. Influences of scan protocols, protection method, and other issues can be easily examined with the developed framework.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP3-02: A Novel Setup Approach to Improve C-Spine Curvature Reproducibility for Head and Neck Radiotherapy Using Optical Surface Imaging with Two Regions of Interest

Purpose: To develop a novel approach to improve cervical spine (c-spine) curvature reproducibility for head and neck (HN) patients using optical surface imaging (OSI) with two regions of interests (ROIs). Methods: The OSI-guided, two-step setup procedure requires two ROIs: ROI-1 of the shoulders and ROI-2 of the face. The neck can be stretched or squeezed in superior-inferior (SI) direction using a specially-designed sliding head support. We hypothesize that when these two ROIs are aligned, the c-spine should fall into a naturally reproducible position under same setup conditions. An anthropomorphous phantom test was performed to examine neck pitch angles comparing with the calculated angles. Three volunteers participated in the experiments, which start with conventional HN setup using skin markers and room lasers. An OSI image and lateral photo-picture were acquired as the references. In each of the three replicate tests, conventional setup was first applied after volunteers got on the couch. ROI-1 was aligned by moving the body, followed by ROI-2 alignment via adjusting head position and orientation under real-time OSI guidance. A final static OSI image and lateral picture were taken to evaluate both anterior and posterior surface alignments. Three degrees of freedom can be adjusted if an open-face mask was applied, including head SI shift using the sliding head support and pitch-and-roll rotations using a commercial couch extension. Surface alignment was analyzed comparing with conventional setup. Results: The neck pitch angle measured by OSI is consistent with the calculated (0.2±0.6°). Volunteer study illustrated improved c-spine setup reproducibility using OSI comparing with conventional setup. ROI alignments with 2mm/1° tolerance are achieved within 3 minutes. Identical knee support is important to achieve ROI-1 pitch alignment. Conclusion: The feasibility of this novel approach has been demonstrated for c-spine curvature setup reproducibility. Further evaluation is necessary with bony alignment variation in patient studies. This study is in part supported by the NIH (U54CA137788).

60 APPLIED LIFE SCIENCES↗

High-bandwidth Modulation of H2/Syngas Fuel to Control Combustion Dynamics in Micro-Mixing Lean Premix Systems

The goal of this program was to develop and demonstrate fuel injection technologies that will facilitate the development of cost-effective turbine engines for Integrated Gasification Combined Cycle (IGCC) power plants, while improving efficiency and reducing emissions. The program involved developing a next-generation multi-point injector with enhanced stability performance for lean premix turbine systems that burn hydrogen (H2) or synthesis gas (syngas) fuels. A previously developed injector that demonstrated superior emissions performance was improved to enhance static flame stability through zone staging and pilot sheltering. In addition, piezo valve technology was implemented to investigate the potential for enhanced dynamic stability through high-bandwidth modulation of the fuel supply. Prototype injector and valve hardware were tested in an atmospheric combustion facility. The program was successful in meeting its objectives. Specifically, the following was accomplished: Demonstrated improvement of lean operability of the Parker multi-point injector through staging of fuel flow and primary zone sheltering; Developed a piezo valve capable of proportional and high-bandwidth modulation of gaseous fuel flow at frequencies as high as 500 Hz; The valve was shown to be capable of effecting changes to flame dynamics, heat release, and acoustic signature of an atmospheric combustor. The latter achievement indicates the viability of the Parker piezo valve technology for use in future adaptively controlled systems for the mitigation of combustion instabilities, particularly for attenuating combustion dynamics under ultra-lean conditions.

08 HYDROGEN↗

Drexel University Temperature Sensors

This document summarizes background information and presents results related to temperature measurements in the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) Drexel University Project 31091 irradiation. The objective of this test was to assess the radiation performance of new ceramic materials for advanced reactor applications. Accordingly, irradiations of transition metal carbides and nitrides were performed using the Hydraulic Shuttle Irradiation System (HSIS) in the B-7 position and in static capsules inserted into the A-3 and East Flux Trap Position 5 locations of the ATR.

36 MATERIALS SCIENCE↗

On linking an Earth system model to the equilibrium carbon representation of an economically optimizing land use model

Human activities are significantly altering biogeochemical cycles at the global scale, posing a significant problem for earth system models (ESMs), which may incorporate static land-use change inputs but do not actively simulate policy or economic forces. One option to address this problem is a to couple an ESM with an economically oriented integrated assessment model. Here we have implemented and tested a coupling mechanism between the carbon cycles of an ESM (CLM) and an integrated assessment (GCAM) model, examining the best proxy variables to share between the models, and quantifying our ability to distinguish climate- and land-use-driven flux changes. CLM’s net primary production and heterotrophic respiration outputs were found to be the most robust proxy variables by which to manipulate GCAM’s assumptions of long-term ecosystem steady state carbon, with short-term forest production strongly correlated with long-term biomass changes in climate-change model runs. By leveraging the fact that carbon-cycle effects of anthropogenic land-use change are short-term and spatially limited relative to widely distributed climate effects, we were able to distinguish these effects successfully in the model coupling, passing only the latter to GCAM. By allowing climate effects from a full earth system model to dynamically modulate the economic and policy decisions of an integrated assessment model, this work provides a foundation for linking these models in a robust and flexible framework capable of examining two-way interactions between human and earth system processes.

carbon cycle↗

Water Start Up Time Model Validation Test

This report is an Oregon Institute of Technology thesis project completed in partial fulfillment for the Masters of Science in Renewable Energy Engineering degree. The testing and research done for this report, investigate the phenomena of water start up time in the spiral case of hydro units. Water start up time is defined as the time it takes for water to accelerate from zero to rated velocity. From analysis of the literature there shows no published article of water start up time being measured and compared to theoretically calculated values. However a multiplier is used to create a buffer in the estimations of water start up time to use in the engineering and selection of governors for hydro units. The multiplier has also been widely used in computer model simulations which causes a dependence of this multiplier. In 2013 an article was published which challenges the hypothesis that water start up time has been over hypothesized and that the multiplier would be of a smaller value than what was hypothesized which would mean that the governing ability is more than what was expected. This proposal of a higher governing ability would mean that the hydro facilities that are currently standing has a higher stability rating than what was initially thought. The higher stability would allow for increased penetration of renewables onto the electrical grid. The lack of actual water start up time measurements as well as the infeasibility of testing on an actual hydro unit meant that a model would need to be designed, built, and tested. The model had two testing parameters that were examined. One of the parameters was flow rate that was controlled by the number of wicket gates that was installed into the system and the other was the reference height from the forebay to tail water. There were one hundred results from the test trials. The data from the trials showed a trend for the multiplier which was not constant as previously hypothesized and instead illustrated a parabolic trend that tapers into a linear digression. This result means that the range of testing was insufficient and the height range in which the trials were taking placed was subjected to higher variability. The results showed that the multiplier used in water start up time is not a constant and is variable based on the water level. The previous hypothesis stating that the water start up time is faster is false. In accordance with the results the trend showed that the actual water start up time is slower than what is hypothesized. This means at lower water levels the hypothesized governing ability is actually less than what is calculated to be using the current method of water start up time calculation for spiral cases. The theoretical analysis showed that with increased water level and flow rate showed that the multiplier has less effect on water start up time. The value of the water start up time tapering off from the experimental data shows that the trend for water start up time for both theoretical and experimental share similarities. An increased testing range of the water level in the trials will hypothetically lower the variability of the multiplier and in turn conform to a linear equation. The linear equation is shown to approach zero with increased head in which a static value can be achieved for a specified range.

13 HYDRO ENERGY↗

Radioisotope Power Systems: Considerations for use of Dynamic versus Static Conversion Technologies for NASA Missions

For more than five decades, Radioisotope Power Systems (RPS) have played a critical role in the exploration of space, enabling missions of scientific discovery to destinations across the solar system by providing electrical power to explore remote, challenging and extreme environments. In particular, RPS enable deep space missions where increased heliocentric distances reduce the ability of solar power to adequately meet spacecraft and instruments power requirements. Some previous notable missions that were enabled by RPS include Nimbus III, the Apollo Sur-face Experiments, the Pioneers 10 and 11, the Viking Mars Landers, Galileo, Ulysses, Cassini, New Horizons and Curiosity. The current operating set of missions that are enabled by RPS are Voyagers 1 and 2, Cassini, New Hori-zons, and Curiosity. The Multi-Mission Radioisotope Thermal Generator (MMRTG) is the current RPS used for mis-sions. An enhanced version of this generator outfitted with higher efficiency thermoelectrics is under development for potential use in the future. There are also current development efforts underway by NASA to explore dynamic power conversion systems such as Brayton and Stirling. This paper will compare and contrast the pros and cons of a generalized dynamic system with the current state-of-the-art thermoelectric static conversion system. The reason for this paper is to calmly analyze the pros and cons so that all the pertinent factors are placed under the same examination light with equal brightness. As with any purchase made the “newness” of certain items sometimes overrides a needed desire to fully vet all characteristics of the merchandise so that the best choice is made. The following areas will be specifically examined and discussed as they may impact the choice of radioisotope power system for a specific mission: • Projected power output to weight ratio (We/kg) • Amount of Pu-238 required per a fixed power output • Excess heat available to be rejected or used • Fueling operations during assembly by the Department of Energy (DOE) • Planetary protection protocol during fueling and testing of RPS • Transportation operations from DOE assembly site to Kennedy Space Center (KSC) • Remote operations at KSC prior to launch during Assembly Test and Launch Operations (ATLO) phase o Timing of the placement of the RPS onto spacecraft/rover o Off-normal operations at KSC

99 GENERAL AND MISCELLANEOUS↗

Mechanical Response of Castlegate Sandstone under Hydrostatic Cyclic Loading

The stress history of rocks in the subsurface affects their mechanical and petrophysical properties. Rocks can often experience repeated cycles of loading and unloading due to fluid pressure fluctuations, which will lead to different mechanical behavior from static conditions. This is of importance for several geophysical and industrial applications, for example, wastewater injection and reservoir storage wells, which generate repeated stress perturbations. Laboratory experiments were conducted with Castlegate sandstone to observe the effects of different cyclic pressure loading conditions on a common reservoir analogue. Each sample was hydrostatically loaded in a triaxial cell to a low effective confining pressure, and either pore pressure or confining pressure was cycled at different rates over the course of a few weeks. Fluid permeability was measured during initial loading and periodically between stress cycles. Samples that undergo cyclic loading experience significantly more inelastic (nonrecoverable) strain compared to samples tested without cyclic hydrostatic loading. Permeability decreases rapidly for all tests during the first few days of testing, but the decrease and variability of permeability after this depend upon the loading conditions of each test. Cycling conditions do affect the mechanical behavior; the elastic moduli decrease with the increasing loading rate and stress cycling. The degree of volumetric strain induced by stress cycles is the major control on permeability change in the sandstones, with less compaction leading to more variation from measurement to measurement. The data indicate that cyclic loading degrades permeability and porosity more than static conditions over a similar period, but the petrophysical properties are dictated more by the hydrostatic loading rate rather than the total length of time stress cycling is imposed.

58 GEOSCIENCES↗

A meshing framework for digital twins for extrusion based additive manufacturing

Additive manufacturing (AM) allows for manufacturing of complex three-dimensional geometries not typically realizable with standard manufacturing practices. The internal microstructure of AM components has a significant impact on mechanical, vibrational, and shock properties and permits richer design space when this is controllable. Due to complex interactions of internal geometry of an extrusion-based AM component, it is common practice to assume homogeneous behavior or to perform characterization testing on specific toolpath configurations. To avoid testing or material waste, it is necessary to develop a consistently accurate numerical simulation framework with relevant boundary value problems that can handle the complicated geometry of internal material microstructure present in AM components. Herein, a framework is proposed to directly create computational meshes suitable for finite element analysis (FEA) of the fine-scale features generated from extrusion-based AM tool paths to maintain a strong process–structure–property-performance linkage. This mesh can be manually or automatically analyzed using standard FEA simulations such as quasi-static preloading or modal analysis. The framework allows an in-silico assessment of a target AM geometry where fine-scale features greatly impact quantities of design interest such as in soft elastomeric lattices where toolpath infill can greatly influence the self-contact of a structure in compression, which we use as a motivating exemplar. This approach greatly reduces both time and resource waste present in traditional build and test design cycles for non-intuitive design spaces, and acts as a tool for use in the production of a key component of a digital twin, a mesh suitable for finite element analysis. In conclusion, it also further allows for the exploration of toolpath infill to optimize component properties beyond simple linear properties such as density and stiffness.

Additive manufacturing↗

Concepts and Tests for the Remote-Controlled Dismantling of the Biological Shield and Form work of the KNK Reactor - 13425

The compact sodium-cooled nuclear reactor facility Karlsruhe (KNK), a prototype Fast Breeder, is currently in an advanced stage of dismantling. Complete dismantling is based on 10 partial licensing steps. In the frame of the 9. decommissioning permit, which is currently ongoing, the dismantling of the biological shield is foreseen. The biological shield consists of heavy reinforced concrete with built-in steel fitments, such as form-work of the reactor tank, pipe sleeves, ventilation channels, and measuring devices. Due to the activation of the inner part of the biological shield, dismantling has to be done remote-controlled. During a comprehensive basic design phase a practical dismantling strategy was developed. Necessary equipment and tools were defined. Preliminary tests revealed that hot wire plasma cutting is the most favorable cutting technology due to the geometrical boundary conditions, the varying distance between cutter and material, and the heavy concrete behind the steel form-work. The cutting devices will be operated remotely via a carrier system with an industrial manipulator. The carrier system has expandable claws to adjust to the varying diameter of the reactor shaft during dismantling progress. For design approval of this prototype development, interaction between manipulator and hot wire plasma cutting was tested in a real configuration. For the demolition of the concrete structure, an excavator with appropriate tools, such as a hydraulic hammer, was selected. Other mechanical cutting devices, such as a grinder or rope saw, were eliminated because of concrete containing steel spheres added to increase the shielding factor of the heavy concrete. Dismantling of the biological shield will be done in a ring-wise manner due to static reasons. During the demolition process, the excavator is positioned on its tripod in three concrete recesses made prior to the dismantling of the separate concrete rings. The excavator and the manipulator carrier system will be operated alternately. Main boundary condition for all the newly designed equipment is the decommissioning housing of limited space within the reactor building containment. To allow for a continuous removal of the concrete rubble, an additional opening on the lowest level of the reactor shaft will be made. All equipment and the interaction of the tools have to be tested before use in the controlled area. Therefore a full-scale model of the biological shield will be provided in a mock-up. The tests will be performed in early 2014. The dismantling of the biological shield is scheduled for 2015. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Corrosion Testing of TiN on Steel Substrates for use in Waste Packages

An outer shield barrier for spent nuclear fuel casks is being developed in order to improve dry cask performance under mechanical, chemical, and radiological burdens. The materials proposed for the outer shield barrier are titanium nitride (TiN), a composite oxide layer consisting of ZrO{sub 2}, TiO{sub 2}, and Al{sub 2}O{sub 3}, and a final layer of molybdenum disulfide (MoS{sub 2}). A proposed multilayer and multicomposite approach are being investigated in order to optimize the outer shield barriers performance. Spent nuclear fuel casks are frequently made, in part, of 304 and 316 stainless steels. These materials have been chosen as substrates to deposit single layer films of the proposed materials. In order to understand how these materials will behave layered and composited it is first necessary to understand how they perform individually. Several corrosion studies have been performed and analyzed for cyclic corrosion and static corrosion in different brine solutions and at different temperatures. The corrosion rate, over potential, activation enthalpy, and entropy of corrosion have been documented in previous publications. One of the main functions of the TiN coating is to serve as a corrosion barrier on the waste package. In this study we investigate pitting corrosion on thin layers of TiN through cyclic polarization testing and scanning electron microscopy. The corrosion protection of thin layers of TiN has been investigated on 304 and 316 stainless steels. Cyclic polarization testing has been used to this end. Corrosion rates have been calculated using tefel fits on data obtained from this testing and SEM images were used in conjunction with this data. Pitting is observed to occur even at the thickest deposition conditions tested. Although the corrosion rates decrease at these thicker values - sometimes dramatically - thicker layers will be deposited in the future to provide complete resistance to pitting. Deposition and testing of these layers is currently underway. (authors)

36 MATERIALS SCIENCE↗

Accuracy in Resolving the First Hydration Layer on a Transition-Metal Oxide Surface: Experiment (AP-XPS) and Theory

Understanding the equilibrium conditions at the metal oxide/aqueous interface is a key component toward visualizing the structure of water in confined environments and differentiating the catalytic activity of transition-metal oxides. While ambient pressure X-ray photoelectron spectroscopy (AP-XPS) has been the primary technique to investigate the formation of a hydration layer on many surfaces, results over the extended relative humidity (RH) range accessible experimentally have not been compared quantitatively to theoretical predictions. With the use of first-principles theoretical methods and accumulated knowledge of AP-XPS spectral analysis, we do so here for a model surface, TiO 2 -terminated undoped SrTiO 3 (100) (STO). The measured distribution of OH and H 2 O coverages from vacuum up to the first hydration layer is in good agreement with a static density functional theory (DFT) configuration involving partial dissociation of H 2 O per Ti-atom mediated by H-bonding. Furthermore, ab initio molecular dynamics (AIMD) simulations at 300 K for select coverages (1/4, 1/2, and 1 ML) test the role of fluctuations and entropy in the competition between adsorption and dissociation with coverage. This comparison between theory and experiment for OH and H 2 O coverages on STO provides a foundation for a more quantitative assessment of the first hydration layer and associated competition between adsorption, dissociation, and H-bonding on transition-metal oxide surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multipurpose modular experimental station for the DiProI beamline of Fermi-Elettra free electron laser

We present a compact modular apparatus with a flexible design that will be operated at the DiProI beamline of the Fermi-Elettra free electron laser (FEL) for performing static and time-resolved coherent diffraction imaging experiments, taking advantage of the full coherence and variable polarization of the short seeded FEL pulses. The apparatus has been assembled and the potential of the experimental setup is demonstrated by commissioning tests with coherent synchrotron radiation. This multipurpose experimental station will be open to general users after installation at the Fermi-Elettra free electron laser in 2011.

43 PARTICLE ACCELERATORS↗