Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Selective separation of Sr by potassium titanates from solution of nitrate - 15248

The radioactive waste treatment is planned in LWTF (Low-level radioactive Waste Treatment Facility, JAEA) for the low-level liquid wastes generated from Tokai-reprocessing facility [1]. The target liquid wastes mainly consist of highly concentrated sodium nitrate (4.7 M NaNO{sub 3}) containing low level radioactive {sup 137}Cs and {sup 90}Sr, while the conventional adsorbent (Titanic acid-PAN) has some problems in the adsorption performance and irradiation resistance. In this study, the adsorption properties of Sr{sup 2+} ions, leaching properties of Sr{sup 2+} and irradiation properties were clarified by using the novel adsorbent of potassium titanates (KT-1). Relatively large uptake percentage (99%) and maximum uptake capacity (0.37 mmol/g) were obtained for the KT-1 compared to that of Titanic acid-PAN. As for the breakthrough properties, KT-1 had the smoother breakthrough carve and larger 5% breakthrough capacity compared to Titanic acid-PAN. From the results of batch and column experiments, KT-1 was effective for the uptake of Sr{sup 2+} ions in the presence of highly concentrated Na{sup +} ions. The leached percentages of Sr{sup 2+} ions form calcined products of Sr-KT-1 in pure water and 0.1 M NaOH were less than the detection limit of ICP-AES, and those in 0.1 M HCl tended to markedly decrease with calcining temperature; the formation of SrTiO{sub 3} phase above 800 deg. deg. C was effective for the lowering of leachability. The irradiation stability of the adsorbent was examined by instrumental analyses and the evaluation for the uptake percentage of Sr{sup 2+} ions by batch method. The growth of surface crystal was observed by SEM, but no significant change in X-ray diffraction peak was observed, and Sr{sup 2+} uptake (%) was almost constant. The novel adsorbent of KT-1 had excellent characteristics for Sr selectivity, uptake capacity, leachability and irradiation resistance. KT-1 is thus effective for the treatment and disposal in LWTF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ohmic losses in coaxial resonators with longitudinal inner-outer corrugation

In this paper, a coaxial resonator with longitudinal inner-outer corrugation is introduced. Its eigen-equation and expression of ohmic losses are derived. Ohmic losses in the cavity are investigated. Results show that ohmic losses in the outer and inner conductors share a similar variation trend, while the former is larger than the later. What's more, changes of the inner and outer slot depth and width induce different variations of ohmic losses on the surface of the inner and outer conductors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-threshold, single-transverse-mode, 940-nm vertical-cavity surface-emitting laser with a mode filter and half-wavelength cavity

We demonstrate a structure for a vertical-cavity surface-emitting laser (VCSEL) with a mode filter and half-wavelength (λ/2) cavity. The effects of λ/2- and λ-cavities on the threshold current are studied. The thickness and etched diameter of the mode filter are optimised to achieve single-transverse-mode output. The results show that when changing from λ-cavity to λ/2-cavity, the threshold current of the VCSEL decreases by 30.7% (from 0.85 mA to 0.65 mA). In addition, for the mode-filter thickness of 80 nm, and the etched diameter of 2.5 μm, the side mode suppression ratio reaches 90 dB, which meets the requirement of single-transverse-mode output. The VCSELs with the optimised design can overcome many difficulties and have great potential in 3D face recognition. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Payload concepts for investigations of electrostatic dust motion on the lunar surface

Significant experimental and computational investigations have explored the feasibility of electrostatically-motivated dust motion on the lunar surface. The motion of lunar dust influences our understanding of the evolution of the surface and may also present a hazard to future exploration vehicles and astronauts. The possibility of a sustained exploration presence on the lunar surface opens the door to long-term experiments on the lunar surface, akin to the science facilities on the International Space Station. We have identified four measurements/observations that would significantly advance our understanding of dust-plasma interactions on the lunar surface. In this context, we provide conceptual designs for payloads to obtain these observations: a Langmuir probe, dust deposit witness plate, regolith charge measurement instrument, and cameras to look for evidence of horizon glow. These payloads could deploy independently and sequentially, or together as a suite. The proposed payloads would provide key observations that would inform future modeling efforts and direct future in situ experiments to understand the dust-plasma environment, both for planetary science and spacecraft design applications.

42 ENGINEERING↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Development of intelligent instruments with embedded HTTP servers for control and data acquisition in a cryogenic setup—The hardware, firmware, and software implementation

The power of Ethernet for control and automation technology is being largely understood by the automation industry in recent times. Ethernet with HTTP (Hypertext Transfer Protocol) is one of the most widely accepted communication standards today. Ethernet is best known for being able to control through internet from anywhere in the globe. The Ethernet interface with built-in on-chip embedded servers ensures global connections for crate-less model of control and data acquisition systems which have several advantages over traditional crate-based control architectures for slow applications. This architecture will completely eliminate the use of any extra PLC (Programmable Logic Controller) or similar control hardware in any automation network as the control functions are firmware coded inside intelligent meters itself. Here, we describe the indigenously built project of a cryogenic control system built for linear accelerator at Inter University Accelerator Centre, known as “CADS,” which stands for “Complete Automation of Distribution System.” CADS deals with complete hardware, firmware, and software implementation of the automated linac cryogenic distribution system using many Ethernet based embedded cryogenic instruments developed in-house. Each instrument works as an intelligent meter called device-server which has the control functions and control loops built inside the firmware itself. Dedicated meters with built-in servers were designed out of ARM (Acorn RISC (Reduced Instruction Set Computer) Machine) and ATMEL processors and COTS (Commercially Off-the-Shelf) SMD (Surface Mount Devices) components, with analog sensor front-end and a digital back-end web server implementing remote procedure call over HTTP for digital control and readout functions. At present, 24 instruments which run 58 embedded servers inside, each specific to a particular type of sensor-actuator combination for closed loop operations, are now deployed and distributed across control LAN (Local Area Network). A group of six categories of such instruments have been identified for all cryogenic applications required for linac operation which were designed to build this medium-scale cryogenic automation setup. These devices have special features like remote rebooters, daughter boards for PIDs (Proportional Integral Derivative), etc., to operate them remotely in radiation areas and also have emergency switches by which each device can be taken to emergency mode temporarily. Finally, all the data are monitored, logged, controlled, and analyzed online at a central control room which has a user-friendly control interface developed using LabVIEW{sup ®}. This paper discusses the overall hardware, firmware, software design, and implementation for the cryogenics setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a high efficiency for the calibration method.

, standards, surface roughness, interference micro↗

Radon induced surface contaminations in low background experiments

In neutrinoless double-beta decay and dark matter searches, one of the main issues is to increase the experimental sensitivity through careful material selection and production, minimizing the background contributions. In order to achieve the required, extremely low, counting rates, very stringent requirements must be fulfilled in terms of bulk material radiopurity. As the experimental sensitivity increases, the bulk impurities in the detector components decrease, and surface contaminations start to play an increasingly significant role In fully active detectors, like cryogenic particle detectors, surface contaminations are a critical issue (as shown by the CUORICINO experiment). {sup 222}Rn is by far the most intense source of airborne radioactivity, and if a radio-pure material is exposed to environment where the Radon concentration is not minimized, {sup 210}Pb and {sup 210}Po contaminations can occur. The mechanisms and the dynamics of Radon-induced surface contaminations are reviewed, and specific solutions to prevent and to reject the induced background are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Germanium detectors for nuclear spectroscopy: Current research and development activity at LNL

High-purity Germanium (HPGe) detectors have reached an unprecedented level of sophistication and are still the best solution for high-resolution gamma spectroscopy. In the present work, we will show the results of the characterization of new surface treatments for the production of these detectors, studied in the framework of our multidisciplinary research program in HPGe detector technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high temperature instrument for consecutive measurements of thermal conductivity, electrical conductivity, and Seebeck coefficient

A device for measuring a plurality of material properties is designed to include accurate sensors configured to consecutively obtain thermal conductivity, electrical conductivity, and Seebeck coefficient of a single sample while maintaining a vacuum or inert gas environment. Four major design factors are confirmed as sample-heat spreader mismatch, radiation losses, parasitic losses, and sample surface temperature variance. The design is analyzed using finite element methods for high temperature ranges up to 1000°C as well as ultra-high temperatures up to 2500°C. A temperature uncertainty of 0.46% was estimated for a sample with cold and hot sides at 905.1 and 908.5°C, respectively. The uncertainty at 1000°C was calculated to be 0.7% for a ΔT of 5°C between the hot and cold sides. The thermal conductivity uncertainty was calculated to be -8.6% at ~900°C for a case with radiative gains, and +8.2% at ~1000°C for a case with radiative losses, indicating the sensitivity of the measurement to the temperature of the thermal guard in relation to the heat spreader and sample temperature. Lower limits of -17 and -13% error in thermal conductivity measurements were estimated at the ultra-high temperature of ~2500°C for a single-stage and double-stage radiation shield, respectively. Lastly, it is noted that this design is not limited to electro-thermal characterization and will enable measurement of ionic conductivity and surface temperatures of energy materials under realistic operating conditions in extreme temperature environments.

47 OTHER INSTRUMENTATION↗

Atmospheric Radiation Measurement Program Climate Research Facility Operation quarterly report July 1 - September 30, 2010.

Individual raw datastreams from instrumentation at the Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real-time. Raw and processed data are then sent approximately daily to the ARM Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual datastream, site, and month for the current year and (2) site and fiscal year (FY) dating back to 1998. The U.S. Department of Energy (DOE) requires national user facilities to report time-based operating data. The requirements concern the actual hours of operation (ACTUAL); the estimated maximum operation or uptime goal (OPSMAX), which accounts for planned downtime; and the VARIANCE [1-(ACTUAL/OPSMAX)], which accounts for unplanned downtime. The OPSMAX time for the fourth quarter of FY2010 for the Southern Great Plains (SGP) site is 2097.60 hours (0.95 2208 hours this quarter). The OPSMAX for the North Slope of Alaska (NSA) locale is 1987.20 hours (0.90 2208) and for the Tropical Western Pacific (TWP) locale is 1876.80 hours (0.85 2208). The first ARM Mobile Facility (AMF1) deployment in Graciosa Island, the Azores, Portugal, continues, so the OPSMAX time this quarter is 2097.60 hours (0.95 x 2208). The differences in OPSMAX performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure OPSMAX for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams that have been received by the Archive. Data not at the Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Therefore, data availability is directly related to individual instrument uptime. Thus, the average percentage of data in the Archive represents the average percentage of the time (24 hours per day, 92 days for this quarter) that the instruments were operating this quarter. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period July 1-September 30, 2010, for the fixed sites. Because the AMF operates episodically, the AMF statistics are reported separately and not included in the aggregate average with the fixed sites. This fourth quarter comprises a total of 2208 possible hours for the fixed and mobile sites. The average of the fixed sites exceeded our goal this quarter. The Site Access Request System is a web-based database used to track visitors to the fixed and mobile sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has historically had a Central Facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. Beginning in the second quarter of FY2010, the SGP began a transition to a smaller footprint (150 km x 150 km) by rearranging the original instrumentation and new instrumentation made available through the American Recovery and Reinvestment Act of 2009 (ARRA). The Central Facility and 4 extended facilities will remain, but there will be up to 12 new surface characterization facilities, 4 radar facilities, and 3 profiler facilities sited in the smaller domain. This new configuration will provide observations at scales more appropriate to current and future climate models. The transition to the smaller footprint is ongoing through this quarter. The TWP locale has the Manus, Nauru, and Darwin sites. These sites will also have expanded measurement capabilities with the addition of new instrumentation made available through ARRA funds. It is anticipated that the new instrumentation at all the fixed sites will be in place by the end of calendar year 2011. AMF1 continues its 20-month deployment in Graciosa Island, the Azores, Portugal, that began on May 1, 2009. The AMF will also have additional observational capabilities by the end of 2011. The second ARM Mobile Facility (AMF2) was deployed this quarter to Steamboat Springs, Colorado, in support of the Storm Peak Lab Cloud Property Validation Experiment (STORMVEX). The first field deployment of the second ARM Mobile Facility will be used to validate ARM-developed algorithms that convert the remote sensing measurements to cloud properties for liquid and mixed phase clouds. Although AMF2 is being set up this quarter, the official start date of the field campaign is not until November 1, 2010. This quarterly report provides the cumulative numbers of scientific user accounts by site for the period October 1, 2009-September 30, 2010.

54 ENVIRONMENTAL SCIENCES↗

Experiment Automation with a Robot Arm using the Liquids Reflectometer Instrument at the Spallation Neutron Source

The Liquids Reflectometer instrument installed at the Spallation Neutron Source (SNS) enables observations of chemical kinetics, solid-state reactions and phase-transitions of thin film materials at both solid and liquid surfaces. Effective measurement of these behaviors requires each sample to be calibrated dynamically using the neutron beam and the data acquisition system in a feedback loop. Since the SNS is an intense neutron source, the time needed to perform the measurement can be the same as the alignment process, leading to a labor-intensive operation that is exhausting to users. An update to the instrument control system, completed in March 2013, implemented the key features of automated sample alignment and robot-driven sample management, allowing for unattended operation over extended periods, lasting as long as 20 hours. We present a case study of the effort, detailing the mechanical, electrical and software modifications that were made as well as the lessons learned during the integration, verification and testing process.

automated alignment↗

Surface characterization of nanomaterials and nanoparticles: Important needs and challenging opportunities

This review examines characterization challenges inherently associated with understanding nanomaterials and the roles surface and interface characterization methods can play in meeting some of the challenges. In parts of the research community, there is growing recognition that studies and published reports on the properties and behaviors of nanomaterials often have reported inadequate or incomplete characterization. As a consequence, the true value of the data in these reports is, at best, uncertain. With the increasing importance of nanomaterials in fundamental research and technological applications, it is desirable that researchers from the wide variety of disciplines involved recognize the nature of these often unexpected challenges associated with reproducible synthesis and characterization of nanomaterials, including the difficulties of maintaining desired materials properties during handling and processing due to their dynamic nature. It is equally valuable for researchers to understand how characterization approaches (surface and otherwise) can help to minimize synthesis surprises and to determine how (and how quickly) materials and properties change in different environments. Appropriate application of traditional surface sensitive analysis methods (including x-ray photoelectron and Auger electron spectroscopies, scanning probe microscopy, and secondary ion mass spectroscopy) can provide information that helps address several of the analysis needs. In many circumstances, extensions of traditional data analysis can provide considerably more information than normally obtained from the data collected. Less common or evolving methods with surface selectivity (e.g., some variations of nuclear magnetic resonance, sum frequency generation, and low and medium energy ion scattering) can provide information about surfaces or interfaces in working environments (operando or in situ) or information not provided by more traditional methods. Although these methods may require instrumentation or expertise not generally available, they can be particularly useful in addressing specific questions, and examples of their use in nanomaterial research are presented.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multispectral and thermal surface imagery and surface elevation mosaics - SGP July 2022

This data set contains high-resolution image products (orthomosaics) acquired from midsized uncrewed aerial systems that have been processed for value-added quality. The instrument itself, a multispectral imager, the Altum by Micasense, captures six spectral bands (red, green blue, NIR, red edge, and LWIR/thermal1) as radiance, which is converted to reflectance via custom code. The code used to develop these images first uses tools from the Micasense Python library2 to apply dark level corrections, row gradient corrections, and radiometric corrections. Next, it uses the processing API from Agisoft Metashape software to align and mosaic the processed imagery, following the processes developed by the USGS' structure from motion workflow documentation.3 Captures at different altitudes (recorded in MSL) produce an orthomosaic, a tif image containing information related to the six spectral bands, and a digital elevation model (DEM), a tif image containing information related to the elevation of the surveyed terraine. Metadata included in every image can be used to extract lat, lon, and reflectance values. 1 https://www.arm.gov/publications/tech_reports/handbooks/doe-sc-arm-tr-281.pdf 2 https://micasense.github.io/imageprocessing/MicaSense%20Image%20Processing%20Setup.html 3 https://pubs.usgs.gov/of/2021/1039/ofr20211039.pdf

54 ENVIRONMENTAL SCIENCES↗

Atomic spins on surfaces

When adapted to cryogenic temperatures and high magnetic fields, a scanning tunneling microscope can assemble and probe spin chains, logic gates, and other configurations of magnetic atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Surface Effects and Electron Emission from Diamond-Amplifier Cathodes

Emission of electrons in diamond experiments based on the promising diamond-amplifier concept was recently demonstrated. Transmission mode experiments have shown the potential to realize over two orders of magnitude charge amplification. However, the recent emission experiments indicate that surface effects should be understood in detail to build cathodes with optimal properties. We have made progress in understanding secondary electron generation and charge transport in diamond with models we implemented in the VORPAL particle-in-cell computational framework. We introduce models that we have been implementing for surface effects (band bending and electron affinity), charge trapping, and electron emission from diamond. Then, we present results from 3D VORPAL diamond-vacuum simulations with the integrated capabilities on generating electrons and holes, initiated by energetic primary electrons, charge transport, and then emission of electrons from diamond into vacuum. Finally, we discuss simulation results on the dependence of the electron emission on diamond surface properties.

43 PARTICLE ACCELERATORS↗

Multispectral and thermal surface imagery and surface elevation mosaics - Pendleton Feb 2023

This data set contains high-resolution image products (orthomosaics) acquired from midsized uncrewed aerial systems that have been processed for value-added quality. The instrument Altum multispectral imager by Micasense, captures in six bands (blue - 475nm, green - 560nm, red - 668nm, red edge - 717nm, near-infrared - 840 and LWIR/thermal - 11000nm. The optical bands are converted to reflectance via custom code using the instantaneous band horizontal irradiance ratio to the radiance of the pixel. The code used to develop these images first uses tools from the Micasense Python library to apply dark level corrections, row gradient corrections, and radiometric corrections. Next, it uses the processing API from Agisoft Metashape software to align and mosaic the processed imagery, following the processes developed by the USGS' structure from motion workflow documentation. Captures from different altitudes are used to produce an orthomosaic at each height. A tif image containing information related to the six spectral bands, and a digital elevation model (DEM), a tif image containing information related to the elevation of the surveyed terrain. 1 https://www.arm.gov/publications/tech_reports/handbooks/doe-sc-arm-tr-281.pdf 2 https://micasense.github.io/imageprocessing/MicaSense%20Image%20Processing%20Setup.html 3 https://pubs.usgs.gov/of/2021/1039/ofr20211039.pdf

54 ENVIRONMENTAL SCIENCES↗