Search NASA⌕ Search

SEARCH · Search NASA

Results for “test and evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heatingequipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ion Exchange Testing with SRF Resin FY2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.0, which was prepared and approved in response to the Test Specification 24590 PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590 PTF TEF RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Hanford Tank Waste Treatment and Immobilization Pl↗

Low Noble Metal Content Catalysts/Electrodes for Hydrogen Production by Water Electrolysis

Commercial proton exchange membrane (PEM)-based electrolyzers require highly expensive catalyst materials such as platinum group metals due to the acidic environment of the membrane. However, by optimizing the catalyst electrode structure for high utilization and activity, the amount of catalyst required can be reduced to an acceptable amount for both lifecycle and capital cost. In this project, we aim to reduce the Pt content by two orders of magnitude in the cathode catalyst for hydrogen evolution reaction (HER) and significantly reduce the Ir content in the anode catalyst for oxygen evolution reaction (OER). Proton has developed a collaboration over the past year and a half with the BNL electrocatalysis group, which will provide key expertise in design and synthesis of core-shell nanocatalysts and innovative structure integration of catalyst synthesis and electrode fabrication. The Phase 1 STTR will focus on optimization of the cathode catalyst and electrode for the hydrogen evolution reaction, and identifying an effective approach for significantly improving anode performance for the OER with reduced noble metal content. The catalyst design will combine the most active, durable components with atomic-level control of core-shell structure and narrow particle size distribution to maximize specific surface area. The synthesis methods will be developed to produce high quality catalysts at low cost for large scale production. GDEs will be fabricated to maximize the catalyst utilization at the cathode. Proton will conduct performance and durability tests, evaluate the results against current state-of-the-art catalysts/electrodes, and will estimate the production costs including lifecycle costs using the H2A model.

36 MATERIALS SCIENCE↗

Development of High Rate Coating Technology for Low Cost Electrochromic Dynamic Windows

Objectives of the Project: The objective of this project was to develop and demonstrate the feasibility of depositing critical electrochromic layers at high rate using new novel vacuum coating sources, to develop a full electrochromic process flow by combining conventional processes with new deposition sources, to characterize, test, evaluate, and optimize the resulting coatings and devices, and, to demonstrate an electrochromic device using the new process flow and sources. As addendum objectives, this project was to develop and demonstrate direct patterning methods with novel integration schemes. The long term objective, beyond this program, is to integrate these innovations to enable production of low-cost, high-performance electrochromic windows produced on highly reliable and high yielding manufacturing equipment and systems.

36 MATERIALS SCIENCE↗

Ion Exchange Testing with SRF Resin FY 2012

Ion exchange using spherical resorcinol-formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in at-tank deployment. Numerous studies have shown SRF resin to be effective for removing 137Cs from a wide variety of actual and simulated tank waste supernatants (Adamson et al. 2006; Blanchard et al. 2008; Burgeson et al. 2004; Duignan and Nash 2009; Fiskum et al. 2006a; Fiskum et al. 2006b; Fiskum et al. 2006c; Fiskum et al. 2007; Hassan and Adu-Wusu 2003; King et al. 2004; Nash et al. 2006). Prior work at the Pacific Northwest National Laboratory (PNNL) has focused primarily on the loading behavior for 4 to 6 M Na solutions at 25 to 45°C. Recent proposed changes to the WTP ion exchange process baseline indicate that loading may include a broader range of sodium molarities (0.1 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. This report discusses ion exchange loading kinetics testing activities performed in accordance with Test Plan TP-WTPSP-002, Rev. 3.01, which was prepared and approved in response to the Test Specification 24590-PTF-TSP-RT-09-002, Rev. 0 (Lehrman 2010) and Test Exception 24590-PTF-TEF-RT-11-00003, Rev. 0 (Meehan 2011). This testing focused on column tests evaluating the impact of elevated temperature on resin degradation over an extended period of time and batch contacts evaluating the impact on Cs loading over a broad range of sodium concentrations (0.1 to 5 M). These changes may be required to alleviate post-filtration precipitation issues and broaden the data range of SRF resin loading under the conditions expected with the new equipment and process changes.

Ion exchange↗

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whether model changes are needed in order to improve its behavior qualitatively and quantitatively.

97 MATHEMATICS AND COMPUTING↗

Utilization of SRNL-developed radiation-resistant polymer in high radiation environments

The radiation-resistant polymer developed by the Savannah River National Laboratory is adaptable for multiple applications to enhance polymer endurance and effectiveness in radiation environments. SRNL offers to collaborate with TEPCO in evaluation, testing, and utilization of SRNL’s radiation-resistant polymer in the D&D of the Fukushima Daiichi NPS. Refinement of the scope and associated costs will be conducted in consultation with TECPO.

36 MATERIALS SCIENCE↗

Innovative approach to reduction of waste streams for cutting operations in remote environments

SRNL proposes to develop and demonstrate an approach using the SRNL rotary microfilter (RMF) technology for reducing waste streams in remote cutting operations during decontamination operations. SRNL offers to collaborate with Tokyo Electric Power Company (TEPCO) in evaluation, testing, and utilization of SRNL’s radiation-hardened rotary microfilter in the deactivation and decommissioning (D&D) operations of the Fukushima Daiichi Nuclear Power Station (NPS). Refinement of the scope and associated costs will be conducted in consultation with TEPCO.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanical properties and microstructure characterization of unirradiated Eurofer-97 steel variants for the EUROfusion project

To understand the microstructure and mechanical property degradation of various Eurofer-97 steel variants being neutron irradiated at HFIR up to 2.5 and 20 dpa for the EUROfusion programme, it is necessary to develop a general understanding of these steels in non-irradiated form. In this context, room temperature mechanical property evaluation tests and multi-length scale microstructure characterization of the different Eurofer-97 steel variants: H, I, J, K, L, M, N, O, P and reference E series steels, was performed at ORNL. Mechanical tests consisted of Vickers hardness indentation measurements, uniaxial tensile tests and fracture toughness tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High Efficiency Motors for Refrigerated Open Display Cases

The project was designed to evaluate, test and quantify the savings available from replacing incumbent motor solutions with QM Power Inc.'s (QMP) new Q-Sync permanent magnet synchronous evaporator fan motors in commercial refrigeration applications.

30 DIRECT ENERGY CONVERSION↗

High Efficiency OLED Light Engine

LED Specialists has accomplished the program objective in designing a high efficiency OLED light engine combining high-performance OLED panels in the 5W-8W range. We achieved our goal by using an Active-Clamp Flyback circuit topology using state-of-the-art electronics. Evaluation testing of our second-generation prototype PC board has demonstrated an efficiency rating of 93% and dimming capability between 100% and 5% of OLED brightness. A reliability analysis of the design shows it to have a predicted Mean Time Between Failures (MTBF) of approximately 1,000,000 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sequim Bay Underwater UXO Prototype Demonstration Site: Field Operations Summary, 2020

This report provides a summary of Pacific Northwest National Laboratory’s (PNNL’s) activities to initiate Phase II development of the Sequim Bay Underwater UXO Prototype demonstration site (MR-2735) in 2020. Testbed development and field operations were conducted by PNNL’s Coastal and Marine Research Laboratory (MCRL) in support of the Strategic Environmental Research and Development Program (SERDP) and Environmental Security Technology Certification Program (ESTCP) underwater Munitions Response (MR) program. A series of standardized underwater unexploded ordnance (UXO) demonstration sites (“testbeds”) are being developed by SERDP/ESTCP to test, evaluate, and demonstrate technologies that can detect, geolocate, and classify proud and buried munitions in 0–35 m water depths. As a prototype demonstration site, Sequim Bay is a semi-enclosed marine waterbody containing sand and mud sediments with minimal clutter in 5–30 m water depths. MCRL is located at the entrance to Sequim Bay, where it provides operational, logistical, and facilities support for testbed activities.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Operational and Mission Highlights A Monthly Summary of Top Achievements April 2022

When the Laboratory’s Detonator Production team originally completed manufacturing two ALT939 DEV#1 functional cables — the first development units produced in this lot, team members quickly hit an obstacle when electrical testing for these cables failed. Team members sent the cables out for further testing, which revealed the root cause of failure involved the cables’ connectors. Although a challenging issue to resolve, the team worked together and solved the issue ahead of a stipulated deadline, with the cables completed and shipped to support system tests. The team responsible for this challenging work included members from Detonator Production, Nondestructive Testing & Evaluation, and collaborators from Sandia National Laboratories.

42 ENGINEERING↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonizing Cooking Appliances With Hydrogen

A novel hydrogen compatible heterogeneous burner prototype was engineered, fabricated, and evaluated for applications in cooking appliances. The key features targeted and accomplished under this effort included fuel flexibility, tolerance to high hydrogen concentrations (up to 85% in atmospheric design and 100% in premixed design), wide range of thermal power ratings, thermal cycling, reliability, and most importantly safety. The burner was operated in the range of 3000 – 12,000 Btu/h under all practical operating conditions (cold start, hot restart, fuel concentration variance). The heterogeneous oxidation burner technology was evaluated for overall performance targeting safety, reliability, emissions, fuel flexibility, and energy efficiency in a commercial RV and residential cooking range appliance prototypes. The burner demonstrated safe and reliable performance generating infrared heating energy without the consumption of any parasitic energy while using low-cost materials. Performance evaluation testing of the novel IR burner demonstrated fuel flexibility with hydrogen blended natural gas while significantly eliminating air pollutants like NOx and methane and increasing the energy efficiency by up to 20%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗