Effect of mean velocity shear on the dissipation rate of turbulent kinetic energy

The dissipation rate of turbulent kinetic energy in incompressible turbulence is investigated using a two-scale DIA. The dissipation rate is shown to consist of two parts; one corresponds to the dissipation rate used in the current turbulence models of eddy-viscosity type, and another comes from the viscous effect that is closely connected with mean velocity shear. This result can elucidate the physical meaning of the dissipation rate used in the current turbulence models and explain part of the discrepancy in the near-wall dissipation rates between the current turbulence models and direct numerical simulation of the Navier-Stokes equation.

Yoshizawa, Akira↗

On the modeling of low-Reynolds-number turbulence

A full Reynolds-stress closure that is capable of describing the flow all the way to the wall was formulated for turbulent flow through circular pipe. Since viscosity does not appear explicitly in the pressure redistribution terms, conventional high-number models for these terms are found to be applicable. However, the models for turbulent diffusion and viscous dissipation have to be modified to account for viscous diffusion near a wall. Two redistribution and two diffusion models are investigated for their effects on the model calculations. Wall correction to pressure redistribution modeling is also examined. Diffusion effects on calculated turbulent properties are further investigated by simplifying the transport equations to algebraic equations for Reynolds stress. Two approximations are explored. These are the equilibrium and nonequilibrium turbulence assumptions. Finally, the two-equation closure is also used to calculate the flow in question and the results compared with all the other model calculations. Fully developed pipe flows at two moderate Reynolds numbers are used to validate these model calculations.

So, R. M. C.↗

Reduction of wind-tunnel wall interference by controlled wall flow

Corrections for wind tunnel wall interferences are applied successfully to high lift models when the model to tunnel size ratio is small. The accuracy of the corrections becomes poorer when larger models are tested. An alternate method of testing was developed in which flow through the porous walls of the tunnel was actively controlled so as to approximate free air conditions in the neighborhood of the model during the test. The amount and distribution of the controlled flow through the walls is computed using a potential flow representation of the model based on the measured lift. Theoretical analysis is presented to prove the convergence of the method to free air conditions and to substantiate the general three dimensional theory of operation when the normal flow distribution is continuous. A two dimensional tunnel was constructed to evaluate the concept. Results show that substantial reduction of wall interference may be achieved with relatively low values of porosity of actively controlled walls.

Bernstein, S.↗

Nongray radiative gas analyses using the S-N discrete ordinates method

The S-N discrete ordinates method is applied to analyze radiative heat transfer in nongray gases. Spectral correlation between the terms in the equation of transfer is considered for black or nearly nonreflecting walls. Formulations to apply the S-N method using a narrow-band or the exponential wide-band model are presented. The net radiative wall heat fluxes and the radiative source distributions are obtained for uniform, parabolic, and boundary layer-type temperature profiles, as well as for a parabolic concentration profile. The narrow- and wide-band nongray solutions are compared with gray-band approximations using the same band models. The computational speed of the gray-band approximation is obtained at the expense of accuracy in the internal fluxes and radiative source distributions. The wall radiative flux predictions by the gray-band approximation are satisfactory.

Kim, T. K.↗

Hydrogen film cooling investigation

Effects of flow turning, flow acceleration, and supersonic flow on film cooling were determined experimentally and correlated in terms of an entrainment film cooling model. Experiments were conducted using thin walled metal test sections, hot nitrogen mainstream gas, and ambient hydrogen or nitrogen as film coolants. The entrainment film cooling model relates film cooling effectiveness to the amount of mainstream gases entrained with the film coolant in a mixing layer. The experimental apparatus and the analytical model used are described in detail and correlations for the entrainment fraction and film coolant-to-wall heat transfer coefficient are presented.

Rousar, D. C.↗

Development of minimum correction wind tunnels

Flow distortions due to wind tunnel wall interference may be accounted for if the model to tunnel ratio is small, but the theory becomes less reliable as the model becomes larger. This paper presents theoretical analysis and experimental evidence which supports a new concept of wind tunnel. The method employs active control of flow through the walls so that the model is in approximately free air conditions during the test. Practical considerations in the design of such a tunnel are presented. Results indicate that a minimum correction wind tunnel may be achieved with active walls of relatively low porosity.

Bernstein, S.↗

Vortex methods for separated flows

The numerical solution of the Euler or Navier-Stokes equations by Lagrangian vortex methods is discussed. The mathematical background is presented in an elementary fashion and includes the relationship with traditional point-vortex studies, the convergence to smooth solutions of the Euler equations, and the essential differences between two- and three-dimensional cases. The difficulties in extending the method to viscous or compressible flows are explained. The overlap with the excellent review articles available is kept to a minimum and more emphasis is placed on the area of expertise, namely two-dimensional flows around bluff bodies. When solid walls are present, complete mathematical models are not available and a more heuristic attitude must be adopted. The imposition of inviscid and viscous boundary conditions without conformal mappings or image vortices and the creation of vorticity along solid walls are examined in detail. Methods for boundary-layer treatment and the question of the Kutta condition are discussed. Practical aspects and tips helpful in creating a method that really works are explained. The topics include the robustness of the method and the assessment of accuracy, vortex-core profiles, timemarching schemes, numerical dissipation, and efficient programming. Calculations of flows past streamlined or bluff bodies are used as examples when appropriate.

Spalart, Philippe R.↗

Thermal Desktop Modeling of the 2016 CRYOTE-2 Tank Chill and Fill Tests

The storing and transfer of cryogenic propellants is an enabling technology for NASA as it moves to expand future missions into low Earth orbit (LEO) and beyond. The transfer of cryogenic propellants is of particular interest because it has never been successfully demonstrated in microgravity. Several ground tests have been conducted in past decades examining various tank chilldown and fill methods. Creating accurate models using these historical datasets is a vital step toward developing appropriate modeling tools to form pre-test predictions for eventual flight and ground tests of various novel injector concepts. The goal of this work was to create a working model in Thermal Desktop using data from the CRYOTE-2 experiments whose purpose was to demonstrate the chill and fill process in a spherical receiver tank parametrically examining the effect of injection method, receiver tank initial wall temperature and initial state, supply pressure, and mass flow rate on the NVF process. These tests were conducting using liquid nitrogen with different injectors with different injection patterns. The focus of the current work is on one particular spray nozzle. The pressure rise inside the tank, the fill level, and the change in the outside wall temperature were all tracked and compared with test data. The Thermal Desktop model was able to accurately predict each of these metrics for this nozzle within 11.0%, 22.0%, and 7.0%, respectively.

Cryogenic Tank Chilldown↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Design and Performance Analysis of a Massively Parallel Atmospheric General Circulation Model

In the 1990's computer manufacturers are increasingly turning to the development of parallel processor machines to meet the high performance needs of their customers. Simultaneously, atmospheric scientists study weather and climate phenomena ranging from hurricanes to El Nino to global warming that require increasingly fine resolution models. Here, implementation of a parallel atmospheric general circulation model (GCM) which exploits the power of massively parallel machines is described. Using the horizontal data domain decomposition methodology, this FORTRAN 90 model is able to integrate a 0.6 deg. longitude by 0.5 deg. latitude problem at a rate of 19 Gigaflops on 512 processors of a Cray T3E 600; corresponding to 280 seconds of wall-clock time per simulated model day. At this resolution, the model has 64 times as many degrees of freedom and performs 400 times as many floating point operations per simulated day as the model it replaces.

Schaffer, Daniel S.↗

Chill Down Process of Hydrogen Transport Pipelines

A pseudo-steady model has been developed to predict the chilldown history of pipe wall temperature in the horizontal transport pipeline for cryogenic fluids. A new film boiling heat transfer model is developed by incorporating the stratified flow structure for cryogenic chilldown. A modified nucleate boiling heat transfer correlation for cryogenic chilldown process inside a horizontal pipe is proposed. The efficacy of the correlations is assessed by comparing the model predictions with measured values of wall temperature in several azimuthal positions in a well controlled experiment by Chung et al. (2004). The computed pipe wall temperature histories match well with the measured results. The present model captures important features of thermal interaction between the pipe wall and the cryogenic fluid, provides a simple and robust platform for predicting pipe wall chilldown history in long horizontal pipe at relatively low computational cost, and builds a foundation to incorporate the two-phase hydrodynamic interaction in the chilldown process.

Mei, Renwei↗

Measurements in the near-wall region of a relaxing three-dimensional low speed turbulent air boundary layer

An experimental investigation was conducted at selected locations of the near-wall region of a three dimensional turbulent air boundary layer relaxing in a nominally zero external pressure gradient behind a transverse hump (in the form of a 30 deg swept, 5-foot chord wing-type model) faired into the side wall of a low speed wind tunnel. Wall shear stresses measured with a flush-mounted hot-film gage and a sublayer fence were in very good agreement with experimental data obtained with two Preston probes. With the upstream unit Reynolds number held constant at 325,000/ft. approximately one-fourth of the boundary layer thickness adjacent to the wall was surveyed with a single rotated hot-wire probe mounted on a specially designed minimum interference traverse mechanism. The boundary layer (approximately 3.5 in thick near the first survey station where the length Reynolds number was 5.5 million) had a maximum crossflow velocity ratio of 0.145 and a maximum crossflow angle of 21.875 deg close to the wall.

Hebbar, K. S.↗

A simplified fourwall interference assessment procedure for airfoil data obtained in the Langley 0.3-meter transonic cryogenic tunnel

A simplified fourwall interference assessment method has been described, and a computer program developed to facilitate correction of the airfoil data obtained in the Langley 0.3-m Transonic Cryogenic Tunnel (TCT). The procedure adopted is to first apply a blockage correction due to sidewall boundary-layer effects by various methods. The sidewall boundary-layer corrected data are then used to calculate the top and bottom wall interference effects by the method of Capallier, Chevallier and Bouinol, using the measured wall pressure distribution and the model force coefficients. The interference corrections obtained by the present method have been compared with other methods and found to give good agreement for the experimental data obtained in the TCT with slotted top and bottom walls.

Murthy, A. V.↗

A Parametric Study of a Plug Nozzle, Using the Liquid Propellant Program (LPP) Code

The Liquid Propellant Program (LPP) computer code is a super-set of the industry standard Two Dimensional Kinetics (TDK) computer code. The TDK code uses a two dimensional method of characteristics solution with fully coupled finite rate kinetics for axially symmetric nozzles. The chemical reactions are modeled with a generalized reaction package that include three dimensional body efficiencies and four reaction rate forms. The code performs optional solutions for frozen or equilibrium flow. TDK evaluates discrete shocks, both attached or induced. The Transonic module models variable mixture ratio profiles from the combustion chamber injector. The Mass Addition Boundary Layer module (MABL) calculates the boundary parameters with the same chemistry options, and includes transpiration or tangential slot injection of gas at the wall. The LPP upgrades include: planar nozzle, scarfed nozzles, plug nozzles, and scramjet nozzle configurations. The code evaluates both upper and lower wall flow simulation, and includes the interaction with the external flow. The MABL module evaluates equilibrium radiation heat transfer for both upper and lower walls. In addition, LPP code models combustion effects due to injector inefficiencies with the Spray Combustion Analysis Program (SCAP) module. The LPP package provides extensive post plotting capabilities for flow visualization. The LPP is sufficiently fast and robust to provide performance predictions for extensive parametric studies and sufficiently accurate to provide flow field and performance solutions for detailed studies.

Dunn, Stuart S.↗