Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Structural evolution of the P22-like phages: Comparison of Sf6 and P22 procapsid and virion architectures

Coat proteins of tailed, dsDNA phages and in herpesviruses include a conserved core similar to the bacteriophage HK97 subunit. This core is often embellished with other domains such as the telokin Ig-like domain of phage P22. Eighty-six P22-like phages and prophages with sequenced genomes share a similar set of virion assembly genes and, based on comparisons of twelve viral assembly proteins (structural and assembly/packaging chaperones), these phages are classified into three groups (P22-like, Sf6-like, and CUS-3-like). We used cryo-electron microscopy and 3D image reconstruction to determine the structures of Sf6 procapsids and virions ({approx} 7 A resolution), and the structure of the entire, asymmetric Sf6 virion (16-A resolution). The Sf6 coat protein is similar to that of P22 yet it has differences in the telokin domain and in its overall quaternary organization. Thermal stability and agarose gel experiments show that Sf6 virions are slightly less stable than those of P22. Finally, bacterial host outer membrane proteins A and C were identified in lipid vesicles that co-purify with Sf6 particles, but are not components of the capsid.

60 APPLIED LIFE SCIENCES↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EFFECTS OF DIFFUSE BACKGROUND EMISSION AND SOURCE CROWDING ON PHOTOMETRIC COMPLETENESS IN SPITZER SPACE TELESCOPE IRAC SURVEYS: THE GLIMPSE CATALOGS AND ARCHIVES

We characterize the completeness of point source lists from Spitzer Space Telescope surveys in the four Infrared Array Camera (IRAC) bandpasses, emphasizing the Galactic Legacy Infrared Mid-Plane Survey Extraordinaire (GLIMPSE) programs (GLIMPSE I, II, 3D, 360; Deep GLIMPSE) and their resulting point source Catalogs and Archives. The analysis separately addresses effects of incompleteness resulting from high diffuse background emission and incompleteness resulting from point source confusion (i.e., crowding). An artificial star addition and extraction analysis demonstrates that completeness is strongly dependent on local background brightness and structure, with high-surface-brightness regions suffering up to five magnitudes of reduced sensitivity to point sources. This effect is most pronounced at the IRAC 5.8 and 8.0 {mu}m bands where UV-excited polycyclic aromatic hydrocarbon emission produces bright, complex structures (photodissociation regions). With regard to diffuse background effects, we provide the completeness as a function of stellar magnitude and diffuse background level in graphical and tabular formats. These data are suitable for estimating completeness in the low-source-density limit in any of the four IRAC bands in GLIMPSE Catalogs and Archives and some other Spitzer IRAC programs that employ similar observational strategies and are processed by the GLIMPSE pipeline. By performing the same analysis on smoothed images we show that the point source incompleteness is primarily a consequence of structure in the diffuse background emission rather than photon noise. With regard to source confusion in the high-source-density regions of the Galactic Plane, we provide figures illustrating the 90% completeness levels as a function of point source density at each band. We caution that completeness of the GLIMPSE 360/Deep GLIMPSE Catalogs is suppressed relative to the corresponding Archives as a consequence of rejecting stars that lie in the point-spread function wings of saturated sources. This effect is minor in regions of low saturated star density, such as toward the Outer Galaxy; this effect is significant along sightlines having a high density of saturated sources, especially for Deep GLIMPSE and other programs observing closer to the Galactic center using 12 s or longer exposure times.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-D-BRA-03: Four-Dimensional Dose Reconstruction Through Retrospective Phase Determination Using Cine Images of Electronic Portal Imaging Device

Purpose: To test a method to reconstruct a four-dimensional (4D) dose distribution using the correlation of pre-calculated 4D electronic portal imaging device (EPID) images and measured cine-EPID images. Methods: 1. A phantom designed to simulate a tumor in lung (a polystyrene block with 3.0 cm diameter embedded in cork) was placed on a sinusoidally moving platform with 2 cm amplitude and 4 sec/cycle. Ten-phase 4D CT images were acquired for treatment planning and dose reconstruction. A 6MV photon beam was irradiated on the phantom with static (field size=5×8.5 cm{sup 2}) and dynamic fields (sliding windows, 10×10 cm{sup 2}, X1 MLC closing in parallel with the tumor movement). 2. 4D and 3D doses were calculated forwardly on PTV (1 cm margin). 3. Dose images on EPID under the fields were calculated for 10 phases. 4. Cine EPID images were acquired during irradiation. 5. Their acquisition times were correlated to the phases of the phantom at which irradiation occurred by inter-comparing calculated “reference” EPID images with measured images (2D gamma comparison). For the dynamic beam, the tumor was hidden under MLCs during a portion of irradiation time; the correlation performed when the tumor was visible was extrapolated. 6. Dose for each phase was reconstructed on the 4D CT images and summed over all phases. The summation was compared with forwardly calculated 4D and 3D dose distributions. Monte Carlo methods were used for all calculations. Results: For the open and dynamic beams, the 4D reconstructed doses showed the pass rates of 92.7 % and 100 %, respectively, at the isocenter plane given 3% / 3 mm criteria. The better agreement of the dynamic beam was from its dose gradient which blurred the otherwise sharp difference between forward and reconstructed doses. This also contributed slightly better agreement in DVH of PTV. Conclusion: The feasibility of 4D reconstruction was demonstrated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-799: Verification of a Simultaneous Treatment of Multiple Brain Metastases Using VMAT Technique by a Composite Alanine-Gel Dosimeter Phantom

Purpose: This work presents an end-to-end test using a Gel-Alanine phantom to validate the three-dimensional (3D) dose distribution (DD) delivered by a single isocenter VMAT technique on the simultaneous treatment of multiple brain metastases. Methods: Three cylindrical phantons containing MAGIC-f gel dosimeter were used to measure the 3D DD of a VMAT treatment, the first two were filled with the gel dosimeter (Gel 1 and 2) and the third one was filled with gel and 12 alanine dosimeters distributed along it (Gel 3). Gels 1 and 3 were irradiated and gel 2 was used to map the magnetic resonance image (MRI) scanner field inomogeneities. A CT scan of gel 3 was used for the VMAT treatment planning and 5 alanine pellets were chosen as lesions, around them a PTV was grown and different dose prescriptions were assigned for each one, varying from 5 to 9Gy. Before treatment, the plan was approved in a QA based on an ionization chamber absolute dose measurement, a radiochromic film planar dose measurement and a portal dosimetry per field verification; and also the phantons positioning were verified by ExacTrac 6D correction and OBI kV Cone Beam CT. The gels were irradiated, the MRIs were acquired 24 hours after irradiation and finally, the alanine dosimeters were analysed in a X-band Electron Spin Resonance spectrometer. Results: The association of the two detectors enabled the 3D dose evaluation by gel and punctually inside target volumes by alanine. In the gamma analyses (3%/3mm) comparing the 5 PTVs’ central images DD with TPS expected DD more than 95% of the points were approved. The alanine absolute dose measurements were in agreement with TPS by less than 5%. Conclusion: The gel-alanine phantom enabled the dosimetric validation of multiple brain metastases treatment using VMAT, being an almost ideal tool for this application. This work is partially supported by FAPESP.

60 APPLIED LIFE SCIENCES↗

Field evaluation of semi‐automated moisture estimation from geophysics using machine learning

Geophysical methods can provide three-dimensional (3D), spatially continuous estimates of soil moisture. However, point-to-point comparisons of geophysical properties to measure soil moisture data are frequently unsatisfactory, resulting in geophysics being used for qualitative purposes only. This is because (1) geophysics requires models that relate geophysical signals to soil moisture, (2) geophysical methods have potential uncertainties resulting from smoothing and artifacts introduced from processing and inversion, and (3) results from multiple geophysical methods are not easily combined within a single soil moisture estimation framework. To investigate these potential limitations, an irrigation experiment was performed wherein soil moisture was monitored through time, and several surface geophysical datasets indirectly sensitive to soil moisture were collected before and after irrigation: ground penetrating radar, electrical resistivity tomography (ERT), and frequency domain electromagnetics (FDEM). Data were exported in both raw and processed form, and then snapped to a common 3D grid to facilitate moisture prediction by standard calibration techniques, multivariate regression, and machine learning. A combination of inverted ERT data, raw FDEM, and inverted FDEM data was most informative for predicting soil moisture using a random regression forest model (one-thousand 60/40 training/test cross-validation folds produced root mean squared errors ranging from 0.025–0.046 cm 3 /cm 3 ). This cross-validated model was further supported by a separate evaluation using a test set from a physically separate portion of the study area. Machine learning was conducive to a semi-automated model-selection process that could be used for other sites and datasets to locally improve accuracy.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of tibolone administration in bone architectural by MicroCT

Elderly women are at higher risk for hip fracture because of additional and relatively rapid bone loss due to estrogen deficiency by loss of the ovarian function and a longer average life span than men. The early application of agents that suppress the increase in bone turnover due to estrogen deficiency is essential to prevent bone loss and reduce the risk of osteoporosis. Some advanced imaging techniques may be required to investigate osteoporosis. X-ray micro-computed tomography has been used to generate high-resolution 3D images of cancellous and cortical bone morphology from normal and pathologic human and animal specimens. The aim of this study is to verify the effects of tibolone administration by evaluating the trabecular bone region. The experiment was performed on two groups of rats previously ovariectomized in which one received tibolone while the other did not. Tibolone administration (1 mg/day) began thirty days after the ovariectomy and the treatment remained for five months. At last, the animals were euthanized and femurs were collected. The scan was obtained using a Hamamatsu 10 Mp camera with a pixel size of 11.59 {mu}m and trabecular region in the right femoral head were quantified. All results were statistically evaluated with significance set at P<0.05%. Tibolone administration was shown to be beneficial in some analysis of the femoral head, performing higher bone volume and reducing the porosity when compared to ovariectomized. It can be concluded that tibolone administered to ovariectomized rats significantly preserved bone mass in the femoral head and microtomography was an efficient method to identify bone loss process and to evaluate potential therapies, as tibolone administration. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-faced GRAYQB™: a radiation mapping device

GrayQb{trademark} is a novel technology that has the potential to characterize radioactively contaminated areas such as hot cells, gloveboxes, small and large rooms, hallways, and waste tanks. The goal of GrayQb{trademark} is to speed the process of decontaminating these areas, which reduces worker exposures and promotes ALARA considerations. The device employs Phosphorous Storage Plate (PSP) technology as its primary detector material. PSPs, commonly used for medical applications and non-destructive testing, can be read using a commercially available scanner. The goal of GrayQb{trademark} technology is to locate, quantify, and identify the sources of contamination. The purpose of the work documented in this report was to better characterize the performance of GrayQb{trademark} in its ability to present overlay images of the PSP image and the associated visual image of the location being surveyed. The results presented in this report are overlay images identifying the location of hot spots in both controlled and field environments. The GrayQb{trademark} technology has been mainly tested in a controlled environment with known distances and source characteristics such as specific known radionuclides, dose rates, and strength. The original concept for the GrayQb{trademark} device involved utilizing the six faces of a cube configuration and was designed to be positioned in the center of a contaminated area for 3D mapping. A smaller single-faced GrayQb{trademark}, dubbed GrayQb SF, was designed for the purpose of conducting the characterization testing documented in this report. This lighter 2D version is ideal for applications where entry ports are too small for a deployment of the original GrayQb™ version or where only a single surface is of interest. The shape, size, and weight of these two designs have been carefully modeled to account for most limitations encountered in hot cells, gloveboxes, and contaminated areas. GrayQb{trademark} and GrayQb{trademark} SF share the same fundamental detection system design (e.g., pinhole and PSPs). Therefore, performance tests completed on the single face GrayQB in this report is also applicable to the six- faced GrayQB (e.g., ambient light sensitivity and PSP response). This report details the characterization of the GrayQb{trademark} SF in both an uncontrolled environment; specifically, the Savannah River Site (SRS) Plutonium Fuel Form Facility in Building 235-F (Metallurgical Building) and controlled testing at SRS’s Health Physics Instrument Calibration Facility and SRS’s R&D Engineering Imaging and Radiation Systems Building. In this report, the resulting images from the Calibration Facility were obtained by overlaying the PSP and visual images manually using ImageJ. The resulting images from the Building 235-F tests presented in this report were produced using ImageJ and applying response trends developed from controlled testing results. The GrayQb{trademark} technology has been developed in two main stages at Savannah River National Laboratory (SRNL): 1) the GrayQb{trademark} development was supported by SRNL’s Laboratory Directed Research and Development Program and 2) the GrayQb{trademark} SF development and its testing in Building 235-F were supported by the Office of Deactivation and Decommissioning and Facility Engineering (EM-13), U.S. Department of Energy – Office of Environmental Management.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-domain DAS 3D VSP elastic transmission tomography

SUMMARY Full-wavefield elastic imaging of active-source seismic data acquired by downhole receivers commonly offers higher-resolution subsurface images in the vicinity of a borehole compared to conventional surface seismic data sets, which can lack higher-frequency wavefield components due to longer travel paths and increased attenuation. An increasingly used approach for downhole acquisition is vertical seismic profiling (VSP), which has become more attractive when coupled with distributed acoustic sensing (DAS) using optical fibres installed in wells. The main difficulty for generating high-quality images with full-wavefield imaging tools for DAS VSP data, though, is the need for an accurate velocity model. To build plausible velocity models using active-source DAS VSP data, we adopt a 3-D image-domain elastic transmission tomography technique, originally developed for surface-recorded passive (microseismic) data, by exchanging the source and receiver positions (i.e. reciprocity) to mimic a passive-seismic surface monitoring scenario. The inversion approach exploits various images for each source constructed through time-reverse imaging (TRI) of downgoing P- and S-wave first-arrival waveforms. The TRI process uses the kinetic term of the (extended) PS energy imaging condition that exhibits sufficient sensitivity to velocity model errors. The method automatically updates the P- and S-wave velocity models to optimize image focusing via adjoint-state inversion. We illustrate the efficacy of the adopted elastic inversion technique using an active-source DAS 3-D VSP field data set acquired in the North Slope of Alaska. The numerical experiments demonstrate that the inverted elastic velocity models can be further used in full-wavefield acoustic/elastic imaging algorithms to obtain accurate subsurface images.

Oren, Can (ORCID:000000019534265X)↗

The Differential Algebra Based Multiple Level Fast Multipole Algorithm for 3D Space Charge Field Calculation and Photoemission Simulation

Coulomb interaction between charged particles inside a bunch is one of the most importance collective effects in beam dynamics, becoming even more significant as the energy of the particle beam is lowered to accommodate analytical and low-Z material imaging purposes such as in the time resolved Ultrafast Electron Microscope (UEM) development currently underway at Michigan State University. In addition, space charge effects are the key limiting factor in the development of ultrafast atomic resolution electron imaging and diffraction technologies and are also correlated with an irreversible growth in rms beam emittance due to fluctuating components of the nonlinear electron dynamics. In the short pulse regime used in the UEM, space charge effects also lead to virtual cathode formation in which the negative charge of the electrons emitted at earlier times, combined with the attractive surface field, hinders further emission of particles and causes a degradation of the pulse properties. Space charge and virtual cathode effects and their remediation are core issues for the development of the next generation of high-brightness UEMs. Since the analytical models are only applicable for special cases, numerical simulations, in addition to experiments, are usually necessary to accurately understand the space charge effect. In this paper we will introduce a grid-free differential algebra based multiple level fast multipole algorithm, which calculates the 3D space charge field for n charged particles in arbitrary distribution with an efficiency of O(n), and the implementation of the algorithm to a simulation code for space charge dominated photoemission processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of controlled prewetting on part formation in binder jet additive manufacturing

Binder jetting is an additive manufacturing process that bonds powder through selectively depositing binder by inkjet printing. The part is then extracted and densified by sintering and/or infiltration. The process offers low costs and fast build rates, but properties can be poor due to residual porosity after sintering. The inkjet printing process may contribute to this residual porosity by creating large pores. The droplet kinetic energy ejects some powder particles from the bed and rearranges others. Particle ejection and rearrangement are theorized to create porous regions in binder-jetted parts. In this work, small amounts of moisture are added to the spread powder before printing and the impact on part formation, part properties, and printing parameters measured with varied droplet spacing, droplet velocity, and print frequency. Moisture is added by applying an atomized fluid mixture to the powder between layer spreading and binder printing. The fluid mixture partially evaporates but leaves a stable residue to increase cohesion and enhance imbibition. Moisture addition to the powder increases the range of droplet spacings for line formation while reducing particle ejection, powder rearrangement, and balling in layer and multilayer parts. Excessive moisture addition decreases the effective saturation of printed lines, but saturation in 3D parts is less impacted. Increased surface roughness in the first few layers of a print was also mitigated with prewetting. Finally, high-speed X-ray imaging verified prewetting reduction in particle ejection and rearrangement.

36 MATERIALS SCIENCE↗

The Occlusion Spectrum for Volume Classification and Visualization

Despite the ever-growing improvements on graphics processing units and computational power, classifying 3D volume data remains a challenge. In this paper, we present a new method for classifying volume data based on the ambient occlusion of voxels. This information stems from the observation that most volumes of a certain type, e.g., CT, MRI or flow simulation, contain occlusion patterns that reveal the spatial structure of their materials or features. Furthermore, these patterns appear to emerge consistently for different data sets of the same type. We call this collection of patterns the \emph{occlusion spectrum} of a dataset. We show that using this occlusion spectrum leads to better two-dimensional transfer functions that can help classify complex data sets in terms of the spatial relationships among features. In general, the ambient occlusion of a voxel can be interpreted as a weighted average of the intensities in a spherical neighborhood around the voxel. Different weighting schemes determine the ability to separate structures of interest in the occlusion spectrum. We present a general methodology for finding such a weighting. We show results of our approach in 3D imaging for different applications, including brain and breast tumor detection and the visualization of turbulent flow.

42 ENGINEERING↗

Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy

Purpose: Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. Methods: The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Results: Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm. With graphics processing unit hardware used to accelerate computations, the 4D-VOI reconstruction required a 40-s reconstruction time. Conclusions: 4D-VOI reconstruction effectively reduces undersampling artifacts and resolves lung tumor motion in 4D-CBCT. The 4D-VOI reconstruction is computationally inexpensive compared with more sophisticated iterative algorithms. Compared with these algorithms, our 4D-VOI reconstruction is an attractive alternative in 4D-CBCT for reconstructing target motion without generating numerous streak artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nondestructive volumetric 3-D chemical mapping of nickel-sulfur compounds at the nanoscale

Nano-structures of nickel (Ni) and nickel subsulfide (Ni{sub 3}S{sub 2}) materials were studied and mapped in 3D with high-resolution x-ray nanotomography combined with full field XANES spectroscopy. This method for characterizing these phases in complex microstructures is an important new analytical imaging technique, applicable to a wide range of nanoscale and mesoscale electrochemical systems.

36 MATERIALS SCIENCE↗

Processing of phase change materials by fused deposition modeling: Toward efficient thermal energy storage designs

We report that recently, several efforts have emerged that employ additive manufacturing techniques to integrate phase change material (PCM) thermal energy storage into geometrically complex designs for advanced thermal management. In this work, we contribute to this emerging research by reporting on the production of a composite nylon-based filament for fused deposition modeling incorporating encapsulated PCMs for 3D printing heat sink geometries. Microencapsulated PCM (MEPCM) with a 6 degrees C transition temperature was selected as the material for thermal energy storage. This transition temperature was selected due to its suitability to provide thermal energy storage to target air-conditioning applications in buildings. In an attempt to improve the thermal conductivity of the composite, fine boron nitride fillers were added, although the effect on improvement was found to be negligible in the overall composite mixture. The nylon-MEPCM ratio in the filaments was optimized, and filaments containing up to 40 wt% MEPCM were successfully synthesized, which were found optimal for 3D printing complex heat sink and other geometries. Thermal and mechanical properties of the filaments were characterized, including latent heat of fusion, thermal conductivity, phase change temperature, tensile strength, and more. Thermal infrared imaging of heat sink geometries printed using the MEPCM filaments undergoing thermal discharging was also conducted. This work presents the most promising result to date in the open literature for a 3D-printed PCM composite in the combination of size, energy density, and geometric complexity of printed parts.

25 ENERGY STORAGE↗

Versatile technique for assessing thickness of 2D layered materials by XPS

X-ray photoelectron spectroscopy (XPS) has been utilized as a versatile method for thickness characterization of various two-dimensional (2D) films. Accurate thickness can be measured simultaneously while acquiring XPS data for chemical characterization of 2D films having thickness up to approximately 10 nm. For validating the developed technique, thicknesses of few-layer graphene (FLG), MoS 2 and amorphous boron nitride (a-BN) layer, produced by microwave plasma chemical vapor deposition (MPCVD), plasma enhanced chemical vapor deposition (PECVD), and pulsed laser deposition (PLD) respectively, were accurately measured. The intensity ratio between photoemission peaks recorded for the films (C 1s, Mo 3d, B 1s) and the substrates (Cu 2p, Al 2p, Si 2p) is the primary input parameter for thickness calculation, in addition to the atomic densities of the substrate and the film, and the corresponding electron attenuation length (EAL). The XPS data was used with a proposed model for thickness calculations, which was verified by cross-sectional transmission electron microscope (TEM) measurement of thickness for all the films. The XPS method determines thickness values averaged over an analysis area which is orders of magnitude larger than the typical area in cross-sectional TEM imaging, hence provides an advanced approach for thickness measurement over large areas of 2D materials. The study confirms that the versatile XPS method allows rapid and reliable assessment of the 2D material thickness and this method can facilitate in tailoring growth conditions for producing very thin 2D materials effectively over a large area. Furthermore, the XPS measurement for a typical 2D material is non-destructive and does not require special sample preparation. Furthermore, after XPS analysis, exactly the same sample can undergo further processing or utilization.

2D film thickness↗

THE DATA REDUCTION PIPELINE FOR THE APACHE POINT OBSERVATORY GALACTIC EVOLUTION EXPERIMENT

The Apache Point Observatory Galactic Evolution Experiment (APOGEE), part of the Sloan Digital Sky Survey III, explores the stellar populations of the Milky Way using the Sloan 2.5-m telescope linked to a high resolution (R ∼ 22,500), near-infrared (1.51–1.70 μm) spectrograph with 300 optical fibers. For over 150,000 predominantly red giant branch stars that APOGEE targeted across the Galactic bulge, disks and halo, the collected high signal-to-noise ratio (>100 per half-resolution element) spectra provide accurate (∼0.1 km s{sup −1}) RVs, stellar atmospheric parameters, and precise (≲0.1 dex) chemical abundances for about 15 chemical species. Here we describe the basic APOGEE data reduction software that reduces multiple 3D raw data cubes into calibrated, well-sampled, combined 1D spectra, as implemented for the SDSS-III/APOGEE data releases (DR10, DR11 and DR12). The processing of the near-IR spectral data of APOGEE presents some challenges for reduction, including automated sky subtraction and telluric correction over a 3°-diameter field and the combination of spectrally dithered spectra. We also discuss areas for future improvement.

79 ASTRONOMY AND ASTROPHYSICS↗

"Sintering" Models and In-Situ Experiments: Data Assimilation for Microstructure Prediction in SLS Additive Manufacturing of Nylon Components

Selective laser sintering methods are workhorses for additively manufacturing polymer-based components. The ease of rapid prototyping also means it is easy to produce illicit components. It is necessary to have a data-calibrated in-situ physical model of the build process in order to predict expected and defective microstructure characteristics that inform component provenance. Toward this end, sintering models are calibrated and characteristics such as component defects are explored. This is accomplished by assimilating multiple data streams, imaging analysis, and computational model predictions in an adaptive Bayesian parameter estimation algorithm. From these data sources, along with a phase-field model, bulk porosity distributions are inferred. Model parameters are constrained to physically-relevant search directions by sensitivity analysis, and then matched to predictions using adaptive sampling. Using this feedback loop, data-constrained estimates of sintering model parameters along with uncertainty bounds are obtained.

3D printing, Additive Manufacturing, polymer, sint↗