Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Accuracy of the centrifugal sudden approximation in the H + CHD{sub 3} → H{sub 2} + CD{sub 3} reaction

The initial state selected time-dependent wave packet method has been extended to calculate the coupled-channel reaction probabilities with total angular momentum J{sub tot} > 0 for the title reaction with seven degrees of freedom included. Fully converged integral cross sections were obtained for the ground and a number of vibrational excited initial states on a new potential energy surface recently constructed by this group using neural network fitting. As found from a previous study with the centrifugal sudden (CS) approximation, all these initial vibrational excitations investigated in this study enhance the reactivity considerably at a given collision energy, in particular the CH stretch excited state. The energy initially deposited in CH stretch motion is more effective than translational energy on promoting the reaction in the entire energy region, while for CH bending or CD{sub 3} umbrella excitations only at the high collision energy the vibrational energy becomes more effective. Our calculations also revealed that the accuracy of the CS approximation considerably deteriorates with the increase of J{sub tot}, in particular on the threshold energy. The CS approximation underestimates the integral cross sections for all these initial states, albeit not very severely. In general, it works better at high collision energies and for vibrationally excited initial states, with the increase of integral cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy

A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10–60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 μm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10–60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated electrostatic probe device of high resolution and accuracy

In this work, an automated apparatus for driving single electrostatic probes and acquiring the plasma-related data has been designed and fabricated. The voltage range of the present system is ±110 V with an adjustable voltage step as low as 3 mV. Voltage and current measurements are carried out with high resolution and high accuracy circuits, both based on 16 bit analog-to-digital converters. The code embedded in a micro-controller, schedules the operation of the device and transfers the experimental data to a personal computer. The modular design of the system makes possible its modification and thus increases its adaptability to different plasma setups. Finally, the reliable operation of the entire device is confirmed by tests in Electron Cyclotron Resonance plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct coupled-channels deperturbation analysis of the A{sup 1}Σ{sup +} ∼ b{sup 3}Π complex in LiCs with experimental accuracy

We have carried out the direct deperturbation analysis of about 780 rovibronic term values of the strongly spin-orbit (SO) coupled A{sup 1}Σ{sup +} and b{sup 3}Π states of the {sup 7}Li{sup 133}Cs molecule recorded by polarization labelling spectroscopy technique. The explicit A{sup 1}Σ{sup +} ∼ b{sup 3}Π{sub Ω=0,1,2} coupled-channels treatment allowed us to reproduce 95% experimental term values with a standard deviation of 0.05 cm{sup −1} which is close to the accuracy of the present experiment. The initial potential energy curves (PECs) of the mutually perturbed states and SO matrix elements were ab initio evaluated in the basis of the spin-averaged wave functions. The empirically refined PECs and SO functions, along with the theoretical transition dipole moments, were used to predict energy and radiative properties of the A ∼ b complex for low J levels of both {sup 7}Li{sup 133}Cs and {sup 6}Li{sup 133}Cs isotopologues. The reasonable candidates for the stimulated Raman transitions between initial Feshbach resonance states, the mixed levels of the A ∼ b complex, and absolute ground X{sup 1}Σ{sup +} (v = 0 and J = 0) state were identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical accuracy from quantum Monte Carlo for the benzene dimer

We report an accurate study of interactions between benzene molecules using variational quantum Monte Carlo (VMC) and diffusion quantum Monte Carlo (DMC) methods. We compare these results with density functional theory using different van der Waals functionals. In our quantum Monte Carlo (QMC) calculations, we use accurate correlated trial wave functions including three-body Jastrow factors and backflow transformations. We consider two benzene molecules in the parallel displaced geometry, and find that by highly optimizing the wave function and introducing more dynamical correlation into the wave function, we compute the weak chemical binding energy between aromatic rings accurately. We find optimal VMC and DMC binding energies of −2.3(4) and −2.7(3) kcal/mol, respectively. The best estimate of the coupled-cluster theory through perturbative triplets/complete basis set limit is −2.65(2) kcal/mol [Miliordos et al., J. Phys. Chem. A 118, 7568 (2014)]. Our results indicate that QMC methods give chemical accuracy for weakly bound van der Waals molecular interactions, comparable to results from the best quantum chemistry methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linear-scaling time-dependent density-functional theory beyond the Tamm-Dancoff approximation: Obtaining efficiency and accuracy with in situ optimised local orbitals

We present a solution of the full time-dependent density-functional theory (TDDFT) eigenvalue equation in the linear response formalism exhibiting a linear-scaling computational complexity with system size, without relying on the simplifying Tamm-Dancoff approximation (TDA). The implementation relies on representing the occupied and unoccupied subspaces with two different sets of in situ optimised localised functions, yielding a very compact and efficient representation of the transition density matrix of the excitation with the accuracy associated with a systematic basis set. The TDDFT eigenvalue equation is solved using a preconditioned conjugate gradient algorithm that is very memory-efficient. The algorithm is validated on a small test molecule and a good agreement with results obtained from standard quantum chemistry packages is found, with the preconditioner yielding a significant improvement in convergence rates. The method developed in this work is then used to reproduce experimental results of the absorption spectrum of bacteriochlorophyll in an organic solvent, where it is demonstrated that the TDA fails to reproduce the main features of the low energy spectrum, while the full TDDFT equation yields results in good qualitative agreement with experimental data. Furthermore, the need for explicitly including parts of the solvent into the TDDFT calculations is highlighted, making the treatment of large system sizes necessary that are well within reach of the capabilities of the algorithm introduced here. Finally, the linear-scaling properties of the algorithm are demonstrated by computing the lowest excitation energy of bacteriochlorophyll in solution. The largest systems considered in this work are of the same order of magnitude as a variety of widely studied pigment-protein complexes, opening up the possibility of studying their properties without having to resort to any semiclassical approximations to parts of the protein environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the accuracy of the Fowler method for monitoring non-constant work functions

The Fowler method is a prominent non-invasive technique to determine the absolute work function of a surface based on the photoelectric effect. The evaluation procedure relies on the correlation of the photocurrent with the incident photon energy hν which is mainly dependent on the surface work function χ. Applying Fowler’s theory of the photocurrent, the measurements can be fitted by the theoretical curve near the threshold hν⪆χ yielding the work function χ and a parameter A. The straightforward experimental implementation of the Fowler method is to use several particular photon energies, e.g. via interference filters. However, with a realization like that the restriction hν ≈ χ can easily be violated, especially when the work function of the material is decreasing during the measurements as, for instance, with coating or adsorption processes. This can lead to an overestimation of the evaluated work function value of typically some 0.1 eV, reaching up to more than 0.5 eV in an unfavorable case. A detailed analysis of the Fowler theory now reveals the background of that effect and shows that the fit-parameter A can be used to assess the accuracy of the determined value of χ conveniently during the measurements. Moreover, a scheme is introduced to quantify a potential overestimation and to perform a correction to χ to a certain extent. The issues are demonstrated exemplarily at the monitoring of the work function reduction of a stainless steel sample surface due to caesiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy of AFM force distance curves via direct solution of the Euler-Bernoulli equation

In an effort to improve the accuracy of force-separation curves obtained from atomic force microscope data, we compare force-separation curves computed using two methods to solve the Euler-Bernoulli equation. A recently introduced method using a direct sequential forward solution, Causal Time-Domain Analysis, is compared against a previously introduced Tikhonov Regularization method. Using the direct solution as a benchmark, it is found that the regularization technique is unable to reproduce accurate curve shapes. Using L-curve analysis and adjusting the regularization parameter, λ, to match either the depth or the full width at half maximum of the force curves, the two techniques are contrasted. Matched depths result in full width at half maxima that are off by an average of 27% and matched full width at half maxima produce depths that are off by an average of 109%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Communication: An adaptive configuration interaction approach for strongly correlated electrons with tunable accuracy

We introduce a new procedure for iterative selection of determinant spaces capable of describing highly correlated systems. This adaptive configuration interaction (ACI) determines an optimal basis by an iterative procedure in which the determinant space is expanded and coarse grained until self-consistency. Two importance criteria control the selection process and tune the ACI to a user-defined level of accuracy. The ACI is shown to yield potential energy curves of N{sub 2} with nearly constant errors, and it predicts singlet-triplet splittings of acenes up to decacene that are in good agreement with the density matrix renormalization group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Schrödinger equation solved for the hydrogen molecule with unprecedented accuracy

The hydrogen molecule can be used for determination of physical constants, including the proton charge radius, and for improved tests of the hypothetical long range force between hadrons, which require a sufficiently accurate knowledge of the molecular levels. In this work, we perform the first step toward a significant improvement in theoretical predictions of H{sub 2} and solve the nonrelativistic Schrödinger equation to the unprecedented accuracy of 10{sup −12}. We hope that it will inspire a parallel progress in the spectroscopy of the molecular hydrogen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing the accuracy of high-dimensional neural network potentials and the systematic molecular fragmentation method: A benchmark study for all-trans alkanes

Many approaches, which have been developed to express the potential energy of large systems, exploit the locality of the atomic interactions. A prominent example is the fragmentation methods in which the quantum chemical calculations are carried out for overlapping small fragments of a given molecule that are then combined in a second step to yield the system’s total energy. Here we compare the accuracy of the systematic molecular fragmentation approach with the performance of high-dimensional neural network (HDNN) potentials introduced by Behler and Parrinello. HDNN potentials are similar in spirit to the fragmentation approach in that the total energy is constructed as a sum of environment-dependent atomic energies, which are derived indirectly from electronic structure calculations. As a benchmark set, we use all-trans alkanes containing up to eleven carbon atoms at the coupled cluster level of theory. These molecules have been chosen because they allow to extrapolate reliable reference energies for very long chains, enabling an assessment of the energies obtained by both methods for alkanes including up to 10 000 carbon atoms. We find that both methods predict high-quality energies with the HDNN potentials yielding smaller errors with respect to the coupled cluster reference.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy improvement in a calibration test bench for accelerometers by a vision system

A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the accuracy of the rate coefficients used in plasma fluid models for breakdown in air

The electrical breakdown of air depends on the balance between creation and loss of charged particles. In fluid models, datasets of the rate coefficients used are obtained either from fits to experimental data or by solutions of the Boltzmann equation. Here, we study the accuracy of the commonly used models for ionization and attachment frequencies and their impact on the prediction of the breakdown threshold for air. We show that large errors can occur depending on the model and propose the most accurate dataset available for modeling of air breakdown phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Algorithms for the reconstruction of the singular wave front of laser radiation: analysis and improvement of accuracy

The possibility of reconstructing a singular wave front of laser beams by the local tilts of the wave front measured with a Hartmann sensor is considered. The accuracy of the reconstruction algorithm described by Fried is estimated and its modification is proposed, which allows one to improve the reliability of the phase reconstruction. Based on the Fried algorithm and its modification, a combined algorithm is constructed whose advantages are demonstrated in numerical experiments. (control of laser radiation parameters)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A factor limiting the accuracy of optical loss measurements in single-mode fibres: ‘frozen-in’ inhomogeneities of the Rayleigh backscatter coefficient

Backscatter coefficient fluctuations at a wavelength of 1560 nm in Fujikura FutureGuide-LWP, Corning ClearCurve XB and Corning SMF-28 ULL telecom fibres have been studied using optical time-domain reflectometry and broadband (10 nm) depolarised light. It has been shown that, under the conditions of our experiments, such fluctuations are ‘frozen-in’ and that a typical standard deviation in noiselike reflectograms is 0.16 dB, with a correlation distance no greater than 1 m. Such results have been obtained for all fibre samples. The effect studied experimentally limits the accuracy of attenuation measurements in optical fibres, especially at short fibre lengths (tens and hundreds of metres). Moreover, it should be taken into account in designing distributed physical parameter sensors using Rayleigh scattering intensity as a reference channel. Possible sources of the inhomogeneities in the fibres are discussed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy of the duration estimates of ultrashort laser pulses using a single-shot second-order intensity autocorrelator

The accuracy of estimating the duration of single-cycle laser pulses with centre wavelengths of 910 and 780 nm is analysed using a single-shot second-order intensity autocorrelator. It is shown that estimates of the single-cycle pulse duration with an error of less than 5 % require the use of KDP crystals with a thickness of no more than 10 μm for the second harmonic generation. At the same time, to estimate the duration of a transform-limited pulse containing ten optical cycles, the crystal thickness can be up to 1 mm. In this case, at an optimum angle of convergence of the first-harmonic beams, the duration estimation error is less than 2 %. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗