Membrane-based reactive separations for process intensification during power generation
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Not Available
The three-dimensional (3D) quasi-static particle-in-cell (PIC) algorithm is a very efficient method for modeling short-pulse laser or relativistic charged particle beam–plasma interactions. In this algorithm, the plasma response, i.e., plasma wave wake, to a non-evolving laser or particle beam is calculated using a set of Maxwell’s equations based on the quasi-static approximate equations that exclude radiation. The plasma fields are then used to advance the laser or beam forward using a large time step. The algorithm is many orders of magnitude faster than a 3D fully explicit relativistic electromagnetic PIC algorithm. It has been shown to be capable to accurately model the evolution of lasers and particle beams in a variety of scenarios. Additionally, at the same time, an algorithm in which the fields, currents and Maxwell equations are decomposed into azimuthal harmonics has been shown to reduce the algorithmic complexity of a 3D explicit PIC algorithm to that of a 2D algorithm when the expansion is truncated while maintaining accuracy for problems with near azimuthal symmetry. This hybrid algorithm uses a PIC description in r–z and a gridless description in . We describe a novel method that combines the quasi-static and hybrid PIC methods. This algorithm expands the fields, charge and current density into azimuthal harmonics. A set of the quasi-static field equations is derived for each harmonic. The complex amplitudes of the fields are then solved using the finite difference method. The beam and plasma particles are advanced in Cartesian coordinates using the total fields. Details on how this algorithm was implemented using a similar workflow to an existing quasi-static code, QuickPIC, are presented. The new code is called QPAD for QuickPIC with Azimuthal Decomposition. Benchmarks and comparisons between a fully 3D explicit PIC code (OSIRIS), a full 3D quasi-static code (QuickPIC), and the new quasi-static PIC code with azimuthal decomposition (QPAD) are also presented.
Not Available
Increasing the efficiency of coal power plants requires raising the operating temperature above 650°C. However, coal ash can severely attack alloy materials at high temperature. For example, the corrosion rates of commercial Fe- and Ni-based alloys are generally greater than 2 mm/year at 750°C in the gas environment of oxy-fuel combustion. Thus, a critical study is needed to determine the effect of the constituents in the ash on corrosion and find an approach to reduce the corrosion rates in an ash-laden environment at high temperature. The role of CaO in the ash (typical of U.S. Western coal ash) has been investigated in laboratory exposure environments with various structural alloys. Detailed results are presented on weight change, scale thickness, internal penetration, microstructural characteristics of corrosion products, and the cracking of scales for the alloys after exposure at 750°C. The thermal stability of K3Al(SO4)3 under the environment of oxy-fuel combustion was determined by thermogravimetric analysis and differential thermal analysis. The reaction of this low melting temperature salt with the CaO-containing ash is discussed. In addition, we performed synchrotron nanobeam X-ray analysis to study the phase and chemical composition of the oxide layers on the alloy surface. Results from these studies are used to address the role of CaO in ash in the long-term corrosion performance of alloys.
Purpose: To compare the outcomes of four cisplatin-based radiochemotherapy regimens in 311 patients with Stage III/IV squamous cell carcinoma of the head and neck. Methods and Materials: Concurrent chemotherapy consisted of three courses of cisplatin 100 mg/m{sup 2} on Day 1 (Group A, n = 74), two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 plus 5-fluorouracil 1,000 mg/m{sup 2} on Days 1-5 (Group B, n = 49), two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 plus 5-fluorouracil 600 mg/m{sup 2} on Days 1-5 (Group C, n = 102), or two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 (Group D, n = 86). The groups were retrospectively compared for toxicity and outcomes, and 11 additional factors were evaluated for outcomes. Results: No significant difference was observed among the groups regarding radiation-related acute oral mucositis and radiation-related late toxicities. Acute Grade 3 skin toxicity was significantly more frequent in Group B than in the patients of the other three groups (p = .013). The chemotherapy-related Grade 3 nausea/vomiting rate was 24% for Group A, 8% for Group B, 9% for Group C, and 6% for Group D (p = .003). The corresponding Grade 3 nephrotoxicity rates were 8%, 1%, 2%, and 1% (p = .019). The corresponding Grade 3-4 hematologic toxicity rates were 35%, 41%, 19%, and 21% (p = .027). Chemotherapy could be completed in 50%, 59%, 74%, and 83% of the Group A, B, C, and D patients, respectively (p = .002). Toxicity-related radiotherapy breaks occurred in 39%, 43%, 21%, and 15% of Groups A, B, C, and D, respectively (p = .005). The 3-year locoregional control rate was 67%, 72%, 60%, and 59% for Groups A, B, C, and D, respectively (p = .48). The corresponding 3-year metastasis-free survival rates were 67%, 74%, 63%, and 79% (p = .31), and the corresponding 3-year survival rates were 60%, 63%, 50%, and 71% (p = .056). On multivariate analysis, Karnofsky performance status, histologic grade, T/N category, preradiotherapy hemoglobin level, completion of chemotherapy, and radiotherapy breaks were associated with the outcome. Conclusion: The four compared radiochemotherapy regimens were not significantly different regarding treatment outcomes. Two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 were better tolerated than the other three regimens.
Purpose: To investigate the dosimetric impact of the heterogeneity dose calculation Acuros (Transpire Inc., Gig Harbor, WA), a grid-based Boltzmann equation solver (GBBS), for brachytherapy in a cohort of cervical cancer patients. Methods and Materials: The impact of heterogeneities was retrospectively assessed in treatment plans for 26 patients who had previously received {sup 192}Ir intracavitary brachytherapy for cervical cancer with computed tomography (CT)/magnetic resonance-compatible tandems and unshielded colpostats. The GBBS models sources, patient boundaries, applicators, and tissue heterogeneities. Multiple GBBS calculations were performed with and without solid model applicator, with and without overriding the patient contour to 1 g/cm{sup 3} muscle, and with and without overriding contrast materials to muscle or 2.25 g/cm{sup 3} bone. Impact of source and boundary modeling, applicator, tissue heterogeneities, and sensitivity of CT-to-material mapping of contrast were derived from the multiple calculations. American Association of Physicists in Medicine Task Group 43 (TG-43) guidelines and the GBBS were compared for the following clinical dosimetric parameters: Manchester points A and B, International Commission on Radiation Units and Measurements (ICRU) report 38 rectal and bladder points, three and nine o'clock, and {sub D2cm3} to the bladder, rectum, and sigmoid. Results: Points A and B, D{sub 2} cm{sup 3} bladder, ICRU bladder, and three and nine o'clock were within 5% of TG-43 for all GBBS calculations. The source and boundary and applicator account for most of the differences between the GBBS and TG-43 guidelines. The D{sub 2cm3} rectum (n = 3), D{sub 2cm3} sigmoid (n = 1), and ICRU rectum (n = 6) had differences of >5% from TG-43 for the worst case incorrect mapping of contrast to bone. Clinical dosimetric parameters were within 5% of TG-43 when rectal and balloon contrast were mapped to bone and radiopaque packing was not overridden. Conclusions: The GBBS has minimal impact on clinical parameters for this cohort of patients with unshielded applicators. The incorrect mapping of rectal and balloon contrast does not have a significant impact on clinical parameters. Rectal parameters may be sensitive to the mapping of radiopaque packing.
Purpose: To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Methods and Materials: Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × -20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. Results: In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Conclusions: Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.
In this study, we extend the moment-based acceleration algorithm for the charge, momentum, and energy conserving Vlasov–Ampère discretization developed in Ref. [1] by including a reduced Fokker–Planck operator. We propose an energy conserving discretization for the Fokker–Planck collision operator. We show by numerical experiment that the new algorithm 1) efficiently converges the nonlinearly coupled Vlasov–Fokker–Planck–Ampère system, and 2) accurately steps over stiff time-scales such as the inverse electron plasma frequency, and the electron–electron collision time-scale. We demonstrate that discrete energy conservation is critical to eliminate numerical heating issues when strong density gradients exist.
In this study, we propose a charge, momentum, and energy conserving discretization for the 1D–1V Vlasov–Ampère system of equations on an Eulerian grid. The new conservative discretization is nonlinear in nature, but can be efficiently converged with a moment-based nonlinear accelerator algorithm. We demonstrate the conservation and convergence properties of the scheme with various numerical examples, including a multi-scale ion–acoustic shockwave problem.
We present a numerical algorithm for simulating the spinodal decomposition described by the three dimensional Cahn–Hilliard–Cook (CHC) equation, which is a fourth-order stochastic partial differential equation with a noise term. The equation is discretized in space and time based on a fully implicit, cell-centered finite difference scheme, with an adaptive time-stepping strategy designed to accelerate the progress to equilibrium. At each time step, a parallel Newton–Krylov–Schwarz algorithm is used to solve the nonlinear system. We discuss various numerical and computational challenges associated with the method. The numerical scheme is validated by a comparison with an explicit scheme of high accuracy (and unreasonably high cost). We present steady state solutions of the CHC equation in two and three dimensions. The effect of the thermal fluctuation on the spinodal decomposition process is studied. We show that the existence of the thermal fluctuation accelerates the spinodal decomposition process and that the final steady morphology is sensitive to the stochastic noise. We also show the evolution of the energies and statistical moments. In terms of the parallel performance, it is found that the implicit domain decomposition approach scales well on supercomputers with a large number of processors.
This work describes the Plasma Simulation Code (psc), an explicit, electromagnetic particle-in-cell code with support for different order particle shape functions. We review the basic components of the particle-in-cell method as well as the computational architecture of the psc code that allows support for modular algorithms and data structure in the code. We then describe and analyze in detail a distinguishing feature of psc: patch-based load balancing using space-filling curves which is shown to lead to major efficiency gains over unbalanced methods and a previously used simpler balancing method.