Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

TU-H-BRC-05: Stereotactic Radiosurgery Optimized with Orthovoltage Beams

Purpose: To achieve improved stereotactic radiosurgery (SRS) dose distributions using orthovoltage energy fluence modulation with inverse planning optimization techniques. Methods: A pencil beam model was used to calculate dose distributions from the institution’s orthovoltage unit at 250 kVp. Kernels for the model were derived using Monte Carlo methods as well as measurements with radiochromic film. The orthovoltage photon spectra, modulated by varying thicknesses of attenuating material, were approximated using open-source software. A genetic algorithm search heuristic routine was used to optimize added tungsten filtration thicknesses to approach rectangular function dose distributions at depth. Optimizations were performed for depths of 2.5, 5.0, and 7.5 cm, with cone sizes of 8, 10, and 12 mm. Results: Circularly-symmetric tungsten filters were designed based on the results of the optimization, to modulate the orthovoltage beam across the aperture of an SRS cone collimator. For each depth and cone size combination examined, the beam flatness and 80–20% and 90–10% penumbrae were calculated for both standard, open cone-collimated beams as well as for the optimized, filtered beams. For all configurations tested, the modulated beams were able to achieve improved penumbra widths and flatness statistics at depth, with flatness improving between 33 and 52%, and penumbrae improving between 18 and 25% for the modulated beams compared to the unmodulated beams. Conclusion: A methodology has been described that may be used to optimize the spatial distribution of added filtration material in an orthovoltage SRS beam to result in dose distributions at depth with improved flatness and penumbrae compared to standard open cones. This work provides the mathematical foundation for a novel, orthovoltage energy fluence-modulated SRS system.

60 APPLIED LIFE SCIENCES↗

DE 1 particle and wave observations in Auroral Kilometric Radiation (AKR) source regions

The high-altitude plasma instrument on board the DE 1 satellite was operating during several near crossings of the AKR source in the nightside auroral region. Observations of electron distributions indicate a region of perpendicular heating adjacent to, and within, the source region. Loss cones, trapped particles, beams, and electron conical distributions are also observed near and within the source region, which extends perpendicular to the magnetic field line for at least 20 km. Near the AKR source region wave-particle interactions appear to have modified the observed electron distributions. We compare the observations to those predicted by recently published numerical simulations.

Menietti, J. D.↗

The linear instability of dilute ultrarelativistic e{sup ±} pair beams

The annihilation of TeV photons from extragalactic TeV sources and the extragalactic background light produces ultrarelativistic e{sup ±} beams, which are subject to powerful plasma instabilities that sap their kinetic energy. Here we study the linear phase of the plasma instabilities that these pair beams drive. To this end, we calculate the linear growth rate of the beam-plasma and oblique instability in the electrostatic approximation in both the reactive and kinetic regimes, assuming a Maxwell–Jüttner distribution for the pair beam. We reproduce the well-known reactive and kinetic growth rates for both the beam-plasma and oblique mode. We demonstrate for the oblique instability that there is a broad spectrum of unstable modes that grow at the maximum rate for a wide range of beam temperatures and wave-vector orientations relative to the beam. We also delineate the conditions for applicability for the reactive and kinetic regimes and find that the beam-plasma mode transitions to the reactive regime at a lower Lorentz factor than the oblique mode due to a combination of their different scalings and the anisotropy of the velocity dispersions. Applying these results to the ultrarelativistic e{sup ±} beams from TeV blazars, we confirm that these beams are unstable to both the kinetic oblique mode and the reactive beam-plasma mode. These results are important in understanding how powerful plasma instabilities may sap the energy of the ultrarelativistic e{sup ±} beams as they propagate through intergalactic space.

79 ASTRONOMY AND ASTROPHYSICS↗

Classical and quantum description of electron trapping during the Cherenkov beam instability in plasma

A nonlinear quantum theory of the Cherenkov instability of a nonrelativistic monoenergetic electron beam in a cold plasma is constructed. It is shown that the instability of a low-density beam is almost purely quantum in nature and results from the emission of one quantum of a plasma wave-a plasmon-by the beam electrons. The number of emitted (and absorbed) plasmons increases with beam density, so, in the limit of high-density beams, the instability becomes a classical Cherenkov beam instability in plasma. Some analytic solutions and estimates are found, detailed numerical results are obtained, and the evolution of the quantum distribution function of the beam electrons in different regimes of the beam instability is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tailored Particle Beams From Single-Component Plasmas

Recently, we developed a non-destructive technique to create narrow beams of electrons (or positrons) of adjustable width and brightness from single-component plasmas confined in a Penning-Malmberg trap [Weber et al., Phys. Plasmas 13, 123502 (2008)]. Here, we review highlights of that work and discuss the distributions in energy of the extracted beams. A simple model for beam extraction predicts Gaussian beam profiles, with transverse spatial widths dependent on the number of particles in the beam. A Maxwellian energy distribution is predicted for small beams. The predictions of the theory are confirmed using electron plasmas. Extraction of over 50% of a trapped plasma into a train of nearly identical beams is demonstrated. Finally, the possibility of creating high quality, electrostatic beams by extraction from the confining magnetic field is discussed.

43 PARTICLE ACCELERATORS↗

Multipole mixtures in gamma transitions from the reaction {sup 92}Mo(n, n'{gamma})

Angular distributions of gamma rays from the reaction {sup 92}Mo(n,n'{gamma}) with respect to the axis of the fast-reactor-neutron beam were measured. The known scheme of levels and gamma transitions in {sup 92}Mo was supplemented. The multipole-mixture parameters {delta} were found for gamma transitions between levels. The relationship between the parameters {delta} and the structure of excited states of {sup 92}Mo is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic Gold Particle-Based Fiducial Markers for Proton Therapy of Prostate Cancer

Purpose: We examined the feasibility of using fiducial markers composed of microscopic gold particles and human-compatible polymers as a means to overcome current problems with conventional macroscopic gold fiducial markers, such as dose reduction and artifact generation, in proton therapy for prostate cancer. Methods and Materials: We examined two types of gold particle fiducial marker interactions: that with diagnostic X-rays and with a therapeutic proton beam. That is, we qualitatively and quantitatively compared the radiographic visibility of conventional gold and gold particle fiducial markers and the CT artifacts and dose reduction associated with their use. Results: The gold particle fiducials could be easily distinguished from high-density structures, such as the pelvic bone, in diagnostic X-rays but were nearly transparent to a proton beam. The proton dose distribution was distorted <5% by the gold particle fiducials with a 4.9% normalized gold density; this was the case even in the worst configuration (i.e., parallel alignment with a single-direction proton beam). In addition, CT artifacts were dramatically reduced for the gold particle mixture. Conclusion: Mixtures of microscopic gold particles and human-compatible polymers have excellent potential as fiducial markers for proton therapy for prostate cancer. These include good radiographic visibility, low distortion of the depth-dose distribution, and few CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-201-04: A Study of Cherenkov Light Generated and Collected in Plastic Scintillation Detector

Purpose: To study Cherenkov light emission in plastic scintillation detectors (PSDs) from a theoretical point of view to identify situations that may arise where the calibration coefficient obtained in one condition is not applicable to another condition. By identifying problematic situations, we hope to provide guidance on how to confidently use PSDs. Methods: Cherenkov light emission in PSD was modelled using basic physical principles. In particular, changes in refractive index as a function of wavelength were accounted for using the Sellmeier empirical equation. Both electron and photon beams were considered. For photons, realistic distributions of secondary charged particles were calculated using Klein-Nishina’s formula. Cherenkov production and collection in PSDs were studied for a range of parameters including beam energy, charged particle momentum distribution, detector orientation and material composition. Finally, experimental validation was made using a commercial plastic scintillation detector. Results: In specific situations, results show that the Cherenkov spectrum coupled in the PSD can deviate from its expected behaviour (i.e. one over the square of the wavelength). In these cases were the model is realistic it is possible to see a peak wavelength instead of a monotonically decreasing function. Consequences of this phenomenon are negligible when the momentum of charged particle is distributed randomly, but in some clinically relevant cases, such as an electron beam at depth close to R50 or for photon beams with minimal scatter component, the value of the calibration coefficient can be altered. Experimental tests with electron beams showed changes in the Cherenkov light ratio, the parameter used in the calibration of PSDs, up to 2–3% depending on the PSD orientation. Conclusion: This work is the first providing a physical explanation for apparent change in PSD calibration coefficient. With this new information at hand, it will be possible to better guide the clinical use of PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging High-Energy Electrons Propagating in a Crystal

It has recently become possible to focus a beam of high-energy electrons to a spot smaller than an atom, with vast potential for the study of condensed matter. We devise an experiment that can image, with subangstrom resolution, the distribution of such an electron beam as it scatters within an atomic lattice. Our experiments reveal the acute sensitivity of the scattered electron distribution to 0.1 A shifts of the impact point. Scattering due to plasmon excitations is also examined. Implications for the study of the atomic and electronic structure of condensed matter are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE HYDROGEN EPOCH OF REIONIZATION ARRAY DISH. I. BEAM PATTERN MEASUREMENTS AND SCIENCE IMPLICATIONS

The Hydrogen Epoch of Reionization Array (HERA) is a radio interferometer aiming to detect the power spectrum of 21 cm fluctuations from neutral hydrogen from the epoch of reionization (EOR). Drawing on lessons from the Murchison Widefield Array and the Precision Array for Probing the EOR, HERA is a hexagonal array of large (14 m diameter) dishes with suspended dipole feeds. The dish not only determines overall sensitivity, but also affects the observed frequency structure of foregrounds in the interferometer. This is the first of a series of four papers characterizing the frequency and angular response of the dish with simulations and measurements. In this paper, we focus on the angular response (i.e., power pattern), which sets the relative weighting between sky regions of high and low delay and thus apparent source frequency structure. We measure the angular response at 137 MHz using the ORBCOMM beam mapping system of Neben et al. We measure a collecting area of 93 m{sup 2} in the optimal dish/feed configuration, implying that HERA-320 should detect the EOR power spectrum at z ∼ 9 with a signal-to-noise ratio of 12.7 using a foreground avoidance approach with a single season of observations and 74.3 using a foreground subtraction approach. Finally, we study the impact of these beam measurements on the distribution of foregrounds in Fourier space.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Dosimetry of the BMRR Horizontal Thimble Tubes and Broad Beam Facility.

The Brookhaven Medical Research Reactor was a 5 mega-watt, light-water cooled and heavy-graphite moderated research facility. It has two shutter-equipped treatment rooms, three horizontally extended thimble tubes, and an ex-core broad beam facility. The three experimental thimbles, or activation ports, external to the reactor tank were designed for several uses, including the investigations on diagnostic and therapeutic methods using radioactive isotopes of very short half-life, the analysis of radiation exposure on tissue-equivalent materials using a collimated neutron beam, and the evaluation of dose effects on biological cells to improve medical treatment. At the broad beam facility where the distribution of thermal neutrons was essential uniform, a wide variety of mammalian whole-body exposures were studied using animals such as burros or mice. Also studied at the broad beam were whole-body phantom experiments, involving the use of a neutron or photon beam streaming through a screen to obtain the flux spectrum suitable for dose analysis on the sugar-urea-water mixture, a tissue-equivalent material. Calculations of the flux and the dose at beam ports based on Monte Carlo particle-transport code were performed, and measurements conducted at the same tally locations were made using bare or cadmium-covered gold foils. Analytical results, which show good agreement with measurement data, are presented in the paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Measuring the Density of a Molecular Cluster Injector via Visible Emission from an Electron Beam

A method to measure the density distribution of a dense hydrogen gas jet is pre- sented. A Mach 5.5 nozzle is cooled to 80K to form a flow capable of molecular cluster formation. A 250V, 10mA electron beam collides with the jet and produces Hα emission that is viewed by a fast camera. The high density of the jet, several 10 16 cm -3 , results in substantial electron depletion, which attenuates the H α emission. The attenuated emission measurement, combined with a simplified electron-molecule collision model, allows us to determine the molecular density profile via a simple iterative calculation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrashort-pulse laser calligraphy

Control of structural modifications inside silica glass by changing the front tilt of an ultrashort pulse is demonstrated, achieving a calligraphic style of laser writing. The phenomena of anisotropic bubble formation at the boundary of an irradiated region and modification transition from microscopic bubbles formation to self-assembled form birefringence are observed, and the physical mechanisms are discussed. The results provide the comprehensive evidence that the light beam with centrosymmetric intensity distribution can produce noncentrosymmetric material modifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transformation of double-half inverse Gaussian hollow beams into superposition of finite Airy beams using an optical Airy transform

In the present work, we investigate theoretically the transformation of a double-half inverse Gaussian hollow (DHIGH) beam into a superposition of finite Airy beams by using an optical Airy transform system. The analytical expression of the generated finite Airy beam is derived by means of the generalized Huygens–Fresnel integral diffraction. Numerical calculations show that the optical Airy transform system converts the central dark spot of the hollow incident beam into peak intensity. It is demonstrated that the characteristics of the transverse intensity distribution of the output finite Airy beam are determined by the phase pattern’s constants of the Airy transform system and the radius size of the incident DHIGH beam. Moreover, it is shown that the profile of the central peak intensity of the generated beam can be controlled by means of the radius size of the incident hollow DHIGH beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing initial baryon stopping and equation of state with rapidity-dependent directed flow of identified particles

In this work, using a (3 + 1)-dimensional hybrid framework with parametric initial conditions, we study the rapidity-dependent directed flow $v_1 (y)$ of identified particles, including pions, kaons, protons, and lambdas in heavy-ion collisions. Cases involving Au + Au collisions are considered, performed at $\sqrt {^SNN}$ ranging from 7.7 to 200 GeV. The dynamics in the beam direction is constrained using the measured pseudo-rapidity distribution of charged particles and the net proton rapidity distribution. Within this framework, the directed flow of mesons is driven by the sideward pressure gradient from the tilted source, and that of baryons mainly due to the initial asymmetric baryon distribution with respect to the beam axis driven by the transverse expansion. Our approach successfully reproduces the rapidity- and beam energy-dependence of $v_1$ for both mesons and baryons. We find that the $v_1 (y)$ of baryons has strong constraining power on the initial baryon stopping, and together with that of mesons, the directed flow probes the equation of state of the dense nuclear matter at finite chemical potentials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-363: Experimentally Validated Pencil Beam Scanning Source Model in TOPAS

Purpose: Monte Carlo method can provide the most accurate dose calculation for pencil beam scanning (PBS) proton therapy if the proton sources and particle interaction mechanisms are correct. Methods: TOPAS 1.8, a simulation tool based on Geant4.9.6, was utilized to simulate proton spot profiles. Proton sources, placed at the phantom surface, were modelled with three two-dimensional Gaussian functions to fit measured in-air spot profiles up to 100 mm radius. Simulations were compared with profiles measured using EBT3 film in Solidwater phantoms at various depths from the surface to the end of range for 100, 115, 150, 180, 210 and 225 MeV proton beams with phantom surface locations at 270 mm upstream and at isocentre. Results: Simulation can reproduce one-dimensional integral dose versus radius within 1 mm/1% and two-dimensional profiles within 1 mm out to 0.1% of the central spot dose for all the studied depths of all energies. For two-dimensional 0.01% isodose, simulation can reproduce all 210 MeV proton beam measurements, but cannot predict the diamond-shaped isodose distributions of the 115 MeV beam. When the proton spots are scanned 100 mm off axis, no profile difference can be found between the central axis and the off axis locations for the 210 MeV beam. For the 115 MeV beam, differences of up to 2 mm are observed at the ends of the diamond-shaped 0.01% isodose contour, implying there are lower energy components in the energy spectrum which are less than 4% of the primary energy. Subsequent simulation demonstrates that adopting such an energy spectrum within the source model can improve the distance agreement by 5–6 mm for isodoses below 0.1% near the end of range of the 115 MeV proton beam. Conclusion: Excellent agreement between simulation and measurement validates our PBS source model and the particle interaction mechanism embedded in TOPAS.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗