Search NASA⌕ Search

SEARCH · Search NASA

Results for “Composite testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Composite Overwrapped Pressure Vessels (COPV) Stress Rupture Test: Part 2

One of the major concerns for the aging Space Shuttle fleet is the stress rupture life of composite overwrapped pressure vessels (COPVs). Stress rupture life of a COPY has been defined as the minimum time during which the composite maintains structural integrity considering the combined effects of stress levels and time. To assist in the evaluation of the aging COPVs in the Orbiter fleet an analytical reliability model was developed. The actual data used to construct this model was from testing of COPVs constructed of similar, but not exactly same materials and pressure cycles as used on Orbiter vessels. Since no actual Orbiter COPV stress rupture data exists the Space Shuttle Program decided to run a stress rupture test to compare to model predictions. Due to availability of spares, the testing was unfortunately limited to one 40" vessel. The stress rupture test was performed at maximum operating pressure at an elevated temperature to accelerate aging. The test was performed in two phases. The first phase, 130 F, a moderately accelerated test designed to achieve the midpoint of the model predicted point reliability. A more aggressive second phase, performed at 160 F, was designed to determine if the test article will exceed the 95% confidence interval ofthe model. In phase 3, the vessel pressure was increased to above maximum operating pressure while maintaining the phase 2 temperature. After reaching enough effectives hours to reach the 99.99% confidence level of the model phase 4 testing began when the temperature was increased to greater than 170 F. The vessel was maintained at phase 4 conditions until it failed after over 3 million effect hours. This paper will discuss the results of this test, it's implications and possible follow-on testing.

Russell, Richard↗

Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN

Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to perform this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing of Full Scale Flight Qualified Kevlar Composite Overwrapped Pressure Vessels

Many decades ago NASA identified a need for low-mass pressure vessels for carrying various fluids aboard rockets, spacecraft, and satellites. A pressure vessel design known as the composite overwrapped pressure vessel (COPV) was identified to provide a weight savings over traditional single-material pressure vessels typically made of metal and this technology has been in use for space flight applications since the 1970's. A typical vessel design consisted of a thin liner material, typically a metal, overwrapped with a continuous fiber yarn impregnated with epoxy. Most designs were such that the overwrapped fiber would carry a majority of load at normal operating pressures. The weight advantage for a COPV versus a traditional singlematerial pressure vessel contributed to widespread use of COPVs by NASA, the military, and industry. This technology is currently used for personal breathing supply storage, fuel storage for auto and mass transport vehicles and for various space flight and aircraft applications. The NASA Engineering and Safety Center (NESC) was recently asked to review the operation of Kevlar 2 and carbon COPVs to ensure they are safely operated on NASA space flight vehicles. A request was made to evaluate the life remaining on the Kevlar COPVs used on the Space Shuttle for helium and nitrogen storage. This paper provides a review of Kevlar COPV testing relevant to the NESC assessment. Also discussed are some key findings, observations, and recommendations that may be applicable to the COPV user community. Questions raised during the investigations have revealed the need for testing to better understand the stress rupture life and age life of COPVs. The focus of this paper is to describe burst testing of Kevlar COPVs that has been completed as a part of an the effort to evaluate the effects of ageing and shelf life on full scale COPVs. The test articles evaluated in this discussion had a diameter of 22 inches for S/N 014 and 40 inches for S/N 011. The time between manufacture and burst was 28 and 22 years. Visual inspection, shearography, heat soak thermography and borescope inspection were performed on vessel S/N 011 and all but shearography was performed on S/N 014 before they were tested and details of this work can be found in a companion paper titled, "Nondestructive Methods and Special Test Instrumentation Supporting NASA Composite Overwrapped Pressure Vessel Assessments." The vessels were instrumented so that measurements could be made to aid in the understanding of vessel response. Measurements made on the test articles included girth, boss displacement, internal volume, multiple point strain, full field strain, eddy current, acoustic emission (AE) pressure and temperature. The test article before and during burst is shown with the pattern used for digital image correlation full field strain measurement blurring as the vessel fails.

Greene, Nathanael↗

Application of Iosipescu specimen geometry to determination of shear strength in unidirectional composites

The Iosipescu (1967) test method, in conjunction with a finite element analysis of anisotropic, unidirectionally reinforced composite specimens, can be used to derive composite shear strength values despite the small size of the samples used. When such a specimen is loaded parallel to the fiber direction, fracture occurs by shear within a narrow region near the center of the specimen; this is consistent with the maximum shear area determined by finite element analysis. The resulting fracture surface, as observed, is characteristic of shear failure, occurring either within the matrix or at the fiber-matrix interface. Problems of compressive and mixed mode failure which accrue to short beam shear specimens are by the present method precluded.

Hurwitz, F. I.↗

Simple torsion test for shear moduli determination of orthotropic composites

The shear moduli G13 and G23 for two different composites (AS/3501 and T300/5209) of uniaxial and cross-ply fiber orientations were determined by torsion testing of flat specimens of rectangular cross section. Torsion tests were run under controlled angle of twist in an electro-hydraulic servo-controlled test system. Both laser and potentiometer methods of measuring the angle of twist were used. The in-plane shear modulus was calculated with a formula for transversally isotropic materials and a formula for orthotropic materials, while the out-of-plane shear modulus was calculated from the orthotropic material formula. Neither the uniaxial nor the angle-ply composite materials studied were transversely isotropic. The degree of anisotropy for the angle-ply materials was several times greater than that of the uniaxial composites. For specimens of uniaxial fiber orientation, the in-plane shear moduli could be calculated to a good approximation by using the isotropic formula and test machine deflection data.

Sumsion, H. T.↗

Autoignition test cell with flexible atmosphere control

Spontaneous combustion temperatures are usually found by simply beating material until it bursts into flames. Test cell allows control of test atmosphere and composition. Reusable device permits periodic sampling of decomposition products in test atmosphere. With modifications, cell could be used to determine melting points and reactivites of wide variety of substances.

Evans, D.↗

Rapidly solidified nickel aluminide of improved stoichiometry and ductilization

It has been found that tri-nickel aluminide compositions are quite sensitive to the ratio of nickel to aluminum in their ability to receive boron as a dopant and that compositions which are relatively poor in the aluminum component can be doped more effectively with boron. Further, it has been found for the nickel aluminides which have lower concentrations of aluminum that the percentage of boron which can be added to the composition to effectively increase the strength of the alloys is . favored by the lower aluminum ratio so that higher concentrations of boron are addable. The compositions which result have significant strength properties based on tensile tests of the compositions.

Alan I Taub↗

Electrical Resistance of SiC/SiC Ceramic Matrix Composites for Damage Detection and Life-Prediction

Ceramic matrix composites (CMC) are suitable for high temperature structural applications such as turbine airfoils and hypersonic thermal protection systems due to their low density high thermal conductivity. The employment of these materials in such applications is limited by the ability to accurately monitor and predict damage evolution. Current nondestructive methods such as ultrasound, x-ray, and thermal imaging are limited in their ability to quantify small scale, transverse, in-plane, matrix cracks developed over long-time creep and fatigue conditions. CMC is a multifunctional material in which the damage is coupled with the material s electrical resistance, providing the possibility of real-time information about the damage state through monitoring of resistance. Here, resistance measurement of SiC/SiC composites under mechanical load at both room temperature monotonic and high temperature creep conditions, coupled with a modal acoustic emission technique, can relate the effects of temperature, strain, matrix cracks, fiber breaks, and oxidation to the change in electrical resistance. A multiscale model can in turn be developed for life prediction of in-service composites, based on electrical resistance methods. Results of tensile mechanical testing of SiC/SiC composites at room and high temperatures will be discussed. Data relating electrical resistivity to composite constituent content, fiber architecture, temperature, matrix crack formation, and oxidation will be explained, along with progress in modeling such properties.

Smith, Craig↗

Out of the Autoclave Fabrication of LaRC[TradeMark] PETI-9 Polyimide Laminates

The NASA Langley Research Center developed polyimide system, LaRC PETI-9, has successfully been processed into composites by high temperature vacuum assisted resin transfer molding (HT-VARTM). To extend the application of this high use temperature material to other out-of-autoclave (OOA) processing techniques, the fabrication of PETI- 9 laminates was evaluated using only a vacuum bag and oven cure. A LaRC PETI-9 polyimide solution in NMP was prepared and successfully utilized to fabricate unidirectional IM7 carbon fiber prepreg that was subsequently processed into composites with a vacuum bag and oven cure OOA process. Composite panels of good quality were successfully fabricated and mechanically tested. Processing characteristics, composite panel quality and mechanical properties are presented in this work. The resultant properties are compared to previously developed LaRC material systems processed by both autoclave and OOA techniques including the well characterized, autoclave processed LaRC PETI-5.

Cano, Robert J.↗

Infusible thermoplastic resin based sandwich structures for wind blade applications and the influence of scrim on facesheet to core interface debonding

Infusible thermoplastic Elium® family of resins from Arkema have garnered much attention in recent years as a possible replacement for thermoset resins in laminate and sandwich composite manufacturing for wind blade applications due to its ease of recyclability and the ability to utilize existing manufacturing processes without imposing complicated variations. However, physical and mechanical properties of the proposed Elium® based thermoplastic composites must be comparable to existing epoxy (thermoset) based composites using manufacturing processes relevant for large wind turbine blades. A 13-meter-long demonstration blade was manufactured for that purpose and sandwich samples were obtained from that project for a detailed study. This paper details three-point flexural properties of unidirectional E-glass fiber reinforced acrylic and epoxy based sandwich panels with identical balsa wood core materials. In addition, to evaluate the relative merit considering debond failure mode, the interfacial critical strain energy release rate, predominantly in mode-1, was compared via single cantilever beam testing. In sandwich composites constructed with balsa wood core material, resin uptake by the balsa core is traditionally impeded via the insertion of a scrim material at the facesheet to core interface. Results revealed that inclusion of scrim mesh layer at the facesheet to core interface reduced flexural properties and strain energy release rates in panels infused with acrylic resin but did not significantly reduce these properties in epoxy infused facesheets.

Engineering↗

Full-scale testing, production and cost analysis data for the advanced composite stabilizer for Boeing 737 aircraft. Volume 1: Technical summary

The full scale ground test, ground vibration test, and flight tests conducted to demonstrate a composite structure stabilizer for the Boeing 737 aircraft and obtain FAA certification are described. Detail tools, assembly tools, and overall production are discussed. Cost analyses aspects covered include production costs, composite material usage factors, and cost comparisons.

Aniversario, R. B.↗

Flight service evaluation of composite helicopter components

This first interim report presents the technical background for including environmental effects in the design of helicopter composite structures, and test results after approximately two year field exposure of components and panels. Composite structural components were removed from Sikorsky S-76 helicopters commercially operated in the Gulf Coast region of Louisiana. Fatigue tests were conducted for a graphite/epoxy tail rotor spar and static test for a graphite/epoxy and Kevlar/epoxy stabilizer. Graphite/epoxy and Kevlar/epoxy panels are being exposed to the outdoor environment in Stratford, Connecticut and West Palm Beach, Florida. For this reporting period the two year panels were returned, moisture measurements taken, and strength tests conducted. Results are compared with initial type certificate strengths for components and with initial laboratory coupon tests for the exposed panels. Comparisons are also presented with predicted and measured moisture contents.

Rich, M. J.↗

Flight service evaluation of composite helicopter components

This first interim report presents the technical background for including environmental effects in the design of helicopter composite structures, and test results after approximately two year field exposure of components and panels. Composite structural components were removed from Sikorsky S-76 helicopters commercially operated in the Gulf Coast region of Louisiana. Fatigue tests were conducted for a graphite/epoxy tail rotor spar and static test for a graphite/epoxy and Kevlar/epoxy stabilizer. Graphite/epoxy and Kevlar/epoxy panels are being exposed to the outdoor environment in Stratford, Connecticut and West Palm Beach, Florida. For this reporting period the two year panels were returned, moisture measurements taken, and strength tests conducted. Results are compared with initial type certificate strengths for components and with initial laboratory coupon tests for the exposed panels. Comparisons are also presented with predicted and measured moisture contents.

Rich, M. J.↗

Certification of damage tolerant composite structure

A reliability based certification testing methodology for impact damage tolerant composite structure was developed. Cocured, adhesively bonded, and impact damaged composite static strength and fatigue life data were statistically analyzed to determine the influence of test parameters on the data scatter. The impact damage resistance and damage tolerance of various structural configurations were characterized through the analysis of an industry wide database of impact test results. Realistic impact damage certification requirements were proposed based on actual fleet aircraft data. The capabilities of available impact damage analysis methods were determined through correlation with experimental data. Probabilistic methods were developed to estimate the reliability of impact damaged composite structures.

Rapoff, Andrew J.↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗