At least 991 records · Page 55

Preparation of metrological states in dipolar-interacting spin systems

Abstract Spin systems are an attractive candidate for quantum-enhanced metrology. Here we develop a variational method to generate metrological states in small dipolar-interacting spin ensembles with limited qubit control. For both regular and disordered spatial spin configurations the generated states enable sensing beyond the standard quantum limit (SQL) and, for small spin numbers, approach the Heisenberg limit (HL). Depending on the circuit depth and the level of readout noise, the resulting states resemble Greenberger-Horne-Zeilinger (GHZ) states or Spin Squeezed States (SSS). Sensing beyond the SQL holds in the presence of finite spin polarization and a non-Markovian noise environment. The developed black-box optimization techniques for small spin numbers ( N ≤ 10) are directly applicable to diamond-based nanoscale field sensing, where the sensor size limits N and conventional squeezing approaches fail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybridization of colloidal handlebodies with singular defects and topological solitons in chiral liquid crystals

Topology can manifest itself in colloids when quantified by invariants like Euler characteristics of nonzero-genus colloidal surfaces, albeit spherical colloidal particles are most often studied, and colloidal particles with complex topology are rarely considered. On the other hand, singular defects and topological solitons often define the physical behavior of the molecular alignment director fields in liquid crystals. Interestingly, nematic liquid crystalline dispersions of colloidal particles allow for probing the interplay between topologies of surfaces and fields, but only a limited number of such cases have been explored so far. Here, we study the hybridization of topological solitons, singular defects, and topologically nontrivial colloidal particles with the genus of surfaces different from zero in a chiral nematic liquid crystal phase. Hybridization occurs when distortions separately induced by colloidal particles and LC solitons overlap, leading to energy minimization-driven redistribution of director field deformations and defects. As a result, hybrid director configurations emerge, combining topological features from both components. We uncover a host of director field configurations complying with topological theorems, which can be controlled by applying electric fields. Rotational and translational dynamics arise due to the nonreciprocal evolution of the director fields in response to alternating electric fields of different frequencies. These findings help define a platform for controlling topologically hyper-complex colloidal structures and dynamics with electrically reconfigurable singular defects and topological solitons induced by colloidal handlebodies.

Lee, Jun-Yong [Hiroshima Univ. (Japan)]↗

Development of analytically capable time-of-flight mass spectrometer with continuous ion introduction

The present article describes the results and findings explored in the course of the development of the analytically capable prototype of continuous time-of-flight (CTOF) mass spectrometer. Currently marketed pulsed TOF (PTOF) instruments use ion introduction with a 10 ns or so pulse width, followed by a waiting period roughly 100 {mu}s. Accordingly, the sample is under excitation in 10{sup -4} part of the total measuring time. This very low duty cycle severely limits the sensitivity of the PTOF method. A possible approach to deal with this problem is to use linear sinusoidal dual modulation technique (CTOF) as described in this article. This way the sensitivity of the method is increased, due to the 50% duty cycle of the excitation. All other types of TOF spectrometer use secondary electron multiplier (SEM) for detection, which unfortunately discriminates in amplification in favor of the lighter ions. This discrimination effect is especially undesirable in a mass spectrometric method, which targets high mass range. In CTOF method, SEM is replaced with Faraday cup detector, thus eliminating the mass discrimination effect. Omitting SEM is made possible by the high ion intensity and the very slow ion detection with some hundred hertz detection bandwidth. The electrometer electronics of the Faraday cup detector operates with amplification 10{sup 10} V/A. The primary ion beam is highly monoenergetic due to the construction of the ion gun, which made possible to omit any electrostatic mirror configuration for bunching the ions. The measurement is controlled by a personal computer and the intelligent signal generator Type Tabor WW 2571, which uses the direct digital synthesis technique for making arbitrary wave forms. The data are collected by a Labjack interface board, and the fast Fourier transformation is performed by the software. Noble gas mixture has been used to test the analytical capabilities of the prototype setup. Measurement presented proves the results of the mathematical calculations as well as the future potentiality for use in chemical analysis of gaseous mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-frequency range, dynamic matching network and power system for the “Shoelace” radio frequency antenna on the Alcator C-Mod tokamak

A wide-frequency range (50–300 kHz) power system has been implemented for use with a new RF antenna – the “Shoelace” antenna – built to drive coherent plasma fluctuations in the edge of the Alcator C-Mod tokamak. A custom, dynamically tunable matching network allows two commercial 1 kW, 50-Ω RF amplifiers to drive the low-impedance, inductive load presented by the antenna. This is accomplished by a discretely variable L-match network, with 81 independently selected steps available for each of the series and parallel legs of the matching configuration. A compact programmable logic device provides a control system that measures the frequency with better than 1 kHz accuracy and transitions to the correct tuning state in less than 1 ms. At least 85% of source power is dissipated in the antenna across the operational frequency range, with a minimum frequency slew rate of 1 MHz/s; the best performance is achieved in the narrower band from 80 to 150 kHz which is of interest in typical experiments. The RF frequency can be run with open-loop control, following a pre-programmed analog waveform, or phase-locked to track a plasma fluctuation diagnostic signal in real time with programmable phase delay; the amplitude control is always open-loop. The control waveforms and phase delay are programmed remotely. These tools have enabled first-of-a-kind measurements of the tokamak edge plasma system response in the frequency range and at the wave number at which coherent fluctuations regulate heat and particle transport through the plasma boundary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the non-stiffness of edge transport in L-mode tokamak plasmas

Transport analyses using first-principle turbulence codes and 11/2 -D transport codes usually study radial transport properties between the tokamak plasma magnetic axis and a normalized minor radius around 0.8. In this region, heat transport shows significantly stiff properties resulting in temperature scalelength values (R∕L{sub T}) that are relatively independent of the level of the radial heat flux. We have studied experimentally in the tokamak à configuration variable [F. Hofmann et al., Plasma Phys. Controlled Fusion 36, B277 (1994)] the radial electron transport properties of the edge region, close to the last closed flux surface, namely, between ρ{sub V}=√(V/V{sub edge})=0.8 to 1. It is shown that electron transport is not stiff in this region and high R∕L{sub Te} values (∼20–40) can be attained even for L-mode confinement. We can define a “pedestal” location, already in L-mode regimes, where the transport characteristics change from constant logarithmic gradient, inside ρ{sub V} = 0.8, to constant gradient between 0.8 and 1.0. In particular, we demonstrate, with well resolved T{sub e} and n{sub e} profiles, that the confinement improvement with plasma current I{sub p}, with or without auxiliary heating, is due to this non-stiff edge region. This new result is used to explain the significant confinement improvement observed with negative triangularity, which could not be explained by theory to date. Preliminary local gyrokinetic simulations are now consistent with an edge, less stiff, region that is more sensitive to triangularity than further inside. We also show that increasing the electron cyclotron heating power increases the edge temperature inverse scalelength, in contrast to the value in the main plasma region. The dependence of confinement on density in ohmic plasmas is also studied and brings new insight in the understanding of the transition between linear and saturated confinement regimes, as well as of the density limit and appearance of a 2/1 tearing mode. The results presented in this paper provide an important new perspective with regards to radial transport in tokamak plasmas which goes beyond L-mode plasmas and explains some previous puzzling results. It is proposed that understanding the transport properties in this edge non-stiff region will also help in understanding the improved and high confinement edge properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the onset of ion cyclotron parametric decay instability of lower hybrid waves in a diverted tokamak

The goal of the lower hybrid current drive (LHCD) program on Alcator C-Mod is to develop and optimize reactor-relevant steady-state plasmas by controlling current density profile. However, current drive efficiency precipitously decreases as the line averaged density (n{sup ¯}{sub e}) increases above ∼1 × 10{sup 20} m{sup −3}. Previous simulations show that the observed loss of current drive efficiency in high density plasmas stems from the interactions of LH waves with edge/scrape-off layer plasmas [Wallace et al., Phys. Plasmas 19, 062505 (2012)]. A recent observation [Baek et al., Plasma Phys. Controlled Fusion 55, 052001 (2013)] shows that the configuration dependent ion cyclotron parametric decay instability (PDI) is excited in the density range where the discrepancy between the experiments and simulations remains. Comparing the observed spectra with the homogeneous growth rate spectra indicates that the observed ion cyclotron PDI can be excited not only at the low-field-side but also at the high-field-side (HFS) edge of the tokamak. The model analysis shows that a relevant PDI process to Alcator C-Mod LHCD experiments is decay into ion cyclotron quasi-mode driven by parallel coupling. The underlying cause of the observed onset of ion cyclotron PDI is likely due to the weaker radial penetration of the LH wave in high density plasmas, which can lead to enhanced convective growth. Configuration-dependent PDIs are found to be correlated with different edge density profiles in different magnetic configurations. While the HFS edge of the tokamak can be potentially susceptible to PDI, as evidenced by experimental observations and ray-tracing analyses, enhancing single-pass absorption is expected to help recover the LHCD efficiency at reactor-relevant densities because it could suppress several parasitic loss mechanisms that are exacerbated in multi-pass regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma acceleration using a radio frequency self-bias effect

In this work plasma acceleration using a RF self-bias effect is experimentally studied. The experiments are conducted using a novel plasma accelerator system, called Neptune, consisting of an inductively coupled plasma source and a RF-biased set of grids. The plasma accelerator can operate in a steady state mode, producing a plasma flow with separately controlled plasma flux and velocity without any magnetic configuration. The operating pressure at the source output is as low as 0.2 mTorr and can further be decreased. The ion and electron flows are investigated by measuring the ion and electron energy distribution functions both space resolved and with different orientations with respect to the flow direction. It is found that the flow of electrons from the source is highly anisotropic and directed along the ion flow and this global flow of accelerated plasma is well localized in the plasma transport chamber. The maximum flux is about 7.5·10{sup 15} ions s{sup −1} m{sup −2} (at standard conditions) on the axis and decreasing to almost zero at a radial distances of more than 15 cm from the flow axis. Varying the RF acceleration voltage in the range 20–350 V, the plasma flow velocity can be changed between 10 and 35 km/s. The system is prospective for different technology such as space propulsion and surface modification and also interesting for fundamental studies for space-related plasma simulations and investigation of the dynamo effect using accelerated rotating plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing the activity of Pd ensembles on graphene by manipulating coordination environment

Atomic dispersion of metal catalysts on a substrate accounts for the increased atomic efficiency of single-atom catalysts (SACs) in various catalytic schemes compared to the nanoparticle counterparts. However, lacking neighboring metal sites has been shown to deteriorate the catalytic performance of SACs in a few industrially important reactions, such as dehalogenation, CO oxidation, and hydrogenation. Metal ensemble catalysts (M n ), an extended concept to SACs, have emerged as a promising alternative to overcome such limitation. Inspired by the fact that the performance of fully isolated SACs can be enhanced by tailoring their coordination environment (CE), we here evaluate whether the CE of M n can also be manipulated in order to enhance their catalytic activity. We synthesized a set of Pd ensembles (Pd n ) on doped graphene supports (Pd n /X-graphene where X = O, S, B, and N). We found that introducing S and N onto oxidized graphene modifies the first shell of Pd n converting Pd–O to Pd–S and Pd–N, respectively. Also, we further found that the B dopant significantly affected the electronic structure of Pd n by serving as an electron donor in the second shell. We examined the performance of Pd n /X-graphene toward selective reductive catalysis, such as bromate reduction, brominated organic hydrogenation, and aqueous-phase CO 2 reduction. We observed that Pd n /N-graphene exhibited superior performance by lowering the activation energy of the rate-limiting step, i.e., H 2 dissociation into atomic hydrogen. The results collectively suggest controlling the CE of SACs in an ensemble configuration is a viable strategy to optimize and enhance their catalytic performance.

36 MATERIALS SCIENCE↗

DYNAMIC STABILITY OF THE SOLAR SYSTEM: STATISTICALLY INCONCLUSIVE RESULTS FROM ENSEMBLE INTEGRATIONS

Due to the chaotic nature of the solar system, the question of its long-term stability can only be answered in a statistical sense, for instance, based on numerical ensemble integrations of nearby orbits. Destabilization of the inner planets, leading to close encounters and/or collisions can be initiated through a large increase in Mercury's eccentricity, with a currently assumed likelihood of ∼1%. However, little is known at present about the robustness of this number. Here I report ensemble integrations of the full equations of motion of the eight planets and Pluto over 5 Gyr, including contributions from general relativity. The results show that different numerical algorithms lead to statistically different results for the evolution of Mercury's eccentricity (e{sub M}). For instance, starting at present initial conditions (e{sub M}≃0.21), Mercury's maximum eccentricity achieved over 5 Gyr is, on average, significantly higher in symplectic ensemble integrations using heliocentric rather than Jacobi coordinates and stricter error control. In contrast, starting at a possible future configuration (e{sub M}≃0.53), Mercury's maximum eccentricity achieved over the subsequent 500 Myr is, on average, significantly lower using heliocentric rather than Jacobi coordinates. For example, the probability for e{sub M} to increase beyond 0.53 over 500 Myr is >90% (Jacobi) versus only 40%-55% (heliocentric). This poses a dilemma because the physical evolution of the real system—and its probabilistic behavior—cannot depend on the coordinate system or the numerical algorithm chosen to describe it. Some tests of the numerical algorithms suggest that symplectic integrators using heliocentric coordinates underestimate the odds for destabilization of Mercury's orbit at high initial e{sub M}.

79 ASTRONOMY AND ASTROPHYSICS↗

Adjustable superconducting anisotropy in MoGe-permalloy hybrids.

We studied the magneto-transport properties of magnetically coupled superconductor ferromagnet MoGe/Permalloy bilayers. The rotatable anisotropy Permalloy ferromagnet with stripe domain structure induces in-plane anisotropy in superconducting order parameter. Superconducting phase diagram shows that near the superconductor-normal state phase boundary the superconductivity is localized in narrow mesoscopic channels just above the magnetic domain walls. By changing the in-plane direction of magnetic stripe domains it is possible to re-configure the direction of the superconducting channels and controllably rotate the direction of the in-plane anisotropy axis in the superconductor.

36 MATERIALS SCIENCE↗

Intense nonclassical light: Controllable two-photon Talbot effect

We study the spatial interference pattern of two-photon correlation function for a coherently phased linear array of N emitters with a double-Raman scheme, each producing nonclassically correlated photon pairs. The N{sup 2} dependence in the two-photon correlation serves as a coherent amplification method for producing intense nonclassical light. The spatial distribution of the correlation can be controlled by lasers, and depends on the detection configuration. For two coincident detectors, the nonclassical correlation displays the spatial Talbot pattern, but modulated by quantum interference effect. The image revival distance is found to be twice the usual Talbot length. For symmetrically located detectors (X{sub 1}=-X{sub 2}), the correlation displays a distorted Talbot pattern with intricate features and lack of symmetry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-plane hexagonal antiferromagnet in the Cu-Mn-As system Cu 0.82 Mn 1.18 As

We report the single-crystal growth and characterization of a hexagonal phase Cu 0.82 Mn 1.18 As, in the Cu-Mn-As system. This compound contains the same square-pyramidal MnAs 5 units as the tetragonal and orthorhombic polymorphs of CuMnAs. Calorimetry, magnetometry, and neutron diffraction measurements reveal antiferromagnetic ordering at 270 K. The magnetic structure consists of a triangular arrangement of spins in the ab plane. Hexagonal Cu 0.82 Mn 1.18 As shows resistivity that varies only weakly from 5 to 300 K, and is many times higher than tetragonal CuMnAs, indicative of a strongly scattering metal. First-principles calculations confirm the metallic band structure with a small density of states at the Fermi energy. The neutron-refined magnetic ground state is close to the computationally determined minimum energy configuration. This compound should serve as a clear control when disentangling the effects of current-driven Néel switching of metallic antiferromagnets since it exhibits in-plane spins but the magnetic ordering does not break degeneracy along the a and b directions, unlike tetragonal CuMnAs.

36 MATERIALS SCIENCE↗

SU-F-T-364: Monte Carlo-Dose Verification of Volumetric Modulated Arc Therapy Plans Using AAPM TG-119 Test Patterns

Purpose: To investigate the Monte Carlo (MC)-based dose verification for VMAT plans by a treatment planning system (TPS). Methods: The AAPM TG-119 test structure set was used for VMAT plans by the Pinnacle3 (convolution/superposition), using a Synergy radiation head of a 6 MV beam with the Agility MLC. The Synergy was simulated with the EGSnrc/BEAMnrc code, and VMAT dose distributions were calculated with the EGSnrc/DOSXYZnrc code by the same irradiation conditions as TPS. VMAT dose distributions of TPS and MC were compared with those of EBT3 film, by 2-D gamma analysis of ±3%/3 mm criteria with a threshold of 30% of prescribed doses. VMAT dose distributions between TPS and MC were also compared by DVHs and 3-D gamma analysis of ±3%/3 mm criteria with a threshold of 10%, and 3-D passing rates for PTVs and OARs were analyzed. Results: TPS dose distributions differed from those of film, especially for Head & neck. The dose difference between TPS and film results from calculation accuracy for complex motion of MLCs like tongue and groove effect. In contrast, MC dose distributions were in good agreement with those of film. This is because MC can model fully the MLC configuration and accurately reproduce the MLC motion between control points in VMAT plans. D95 of PTV for Prostate, Head & neck, C-shaped, and Multi Target was 97.2%, 98.1%, 101.6%, and 99.7% for TPS and 95.7%, 96.0%, 100.6%, and 99.1% for MC, respectively. Similarly, 3-D gamma passing rates of each PTV for TPS vs. MC were 100%, 89.5%, 99.7%, and 100%, respectively. 3-D passing rates of TPS reduced for complex VMAT fields like Head & neck because MLCs are not modeled completely for TPS. Conclusion: MC-calculated VMAT dose distributions is useful for the 3-D dose verification of VMAT plans by TPS.

60 APPLIED LIFE SCIENCES↗

Coherent Beam Combining of High Power Broad-Area Laser Diode Array with a Closed-V-shape External Talbot Cavity

We have coherently combined a high-power broad-area laser diode array by using a feedback loop closed off-axis external Talbot cavity. The off-axis feedback from two gratings provides transverse-mode control of broad-area lasers. The Talbot configuration of the external cavity implements diffractive coupling among laser diodes. Feedback from two gratings increases external cavity quality factor and spectrum selection capability. As a result, spatial coherence was improved and spectral linewidth was narrowed down. The high visibility of the far-field profile indicates that high spatial coherence was achieved. We also observed symmetric far-field profiles indicating that laser array was phase locked to in-phase and out-of-phase super-modes, respectively. Transition between these super-modes was observed by tuning one grating's tilted angle.

42 ENGINEERING↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability

In fall 2019, the National Association of Regulatory Utility Commissioners (NARUC) and the National Association of State Energy Officials (NASEO) initiated a joint Microgrids State Working Group (MSWG), funded by the U.S. Department of Energy (DOE) Office of Electricity (OE). The MSWG aims to bring together NARUC and NASEO members to explore the capabilities, costs, and benefits of microgrids; discuss barriers to microgrid development; and develop strategies to plan, finance, and deploy microgrids to improve resilience. This report, Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability, focuses specifically on how clean energy microgrids can achieve both resilience and clean energy benefits. The paper provides an overview of the challenges faced by clean energy microgrids, outlines benefits that clean energy microgrids can provide, and details economic and cost considerations for the development of clean energy microgrid projects. Outlined in the paper are the necessary technological components of a clean energy microgrid, including generation, storage, energy efficiency measures, and smart controls. Current technologies are highlighted, along with potential configurations of clean technologies that are approaching cost competitiveness with commercially available options. The paper concludes with both policy and regulatory considerations for State Energy Offices and Public Utility Commissions to enhance the development and deployment of clean energy microgrids. Although it touches on the clean energy microgrids’ role in integrating distributed energy resources (DERs) into the larger grid, this is not the focus of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SPARC - Plans for a New Critical Experiment Facility with a Horizontal Split Table

Several critical experiment facilities, sometimes referred to as zero power reactor facilities, have provided crucial data to aid understanding and validate nuclear-physics models since the beginning of nuclear technology. Indeed, the first man-made reactor, Chicago Pile-1, was essentially this type of reactor. However, there was a downturn in nuclear technology development toward the turn of the millennium, and the need for these specialized research facilities waned. Now there are few of these experimental facilities operational in the world and those that remain have relatively small critical assembly machines. The need for criticality safety benchmark experiments at intermediate neutron energy levels and the modern resurgence of interest in advanced reactors designs, many of which do not have historical precedents in terms of nuclear fuel composition, moderator, and coolant combinations, all combine to create a substantial need for a critical experiment facility with a large horizontal split-table (HST) machine. A HST machine is used to arrange two separate and subcritical parts of a core assembly, bring them together in a precise manner to achieve criticality using remote controls, and separate them to achieve a subcritical configuration again. A new effort was recently performed to develop user needs for a HST, assess candidate locations at the Idaho National Laboratory (INL), and develop a plan for deployment. This project is referred to as the System Physics Advanced Reactor Critical facility (SPARC). A few months after this assessment began, and shortly after as a viable pathway was emerging, a series of important presidential executive orders were issued to revitalize nuclear energy in the United States (U.S.). The relevance of SPARC to these executive orders was immediately apparent. The far-reaching potential of SPARC to these executive orders will reside in its ability to produce data which facilitates licensing of advanced nuclear reactor designs while reducing uncertainties to help increase energy production alongside new criticality safety data to enable more efficient nuclear fuel manufacture, transport, and storage.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the Initial Isothermal Physics Measurements at the Fast Flux Test Facility, a Prototypic Liquid Metal Fast Breeder Reactor

The Fast Flux Test Facility (FFTF) was a 400-MWt, sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission reactor plant designed for the irradiation testing of nuclear reactor fuels and materials for the development of liquid metal fast breeder reactors (LMFBRs). The FFTF was fueled with plutonium-uranium mixed oxide (MOX) and reflected by Inconel-600. Westinghouse Hanford Company operated the FFTF as part of the Hanford Engineering Development Laboratory (HEDL) for the U.S. Department of Energy on the Hanford Site near Richland, Washington. Although the FFTF was a testing facility not specifically designed to breed fuel or produce electricity, it did provide valuable information for LMFBR projects and base technology programs in the areas of plant system and component design, component fabrication, prototype testing, and site construction. The major objectives of the FFTF were to provide a strong, disciplined engineering base for the LMFBR program, provide fast flux testing for other U.S. programs, and contribute to the development of a viable self-sustaining competitive U.S. LMFBR industry. During its ten years of operation, the FFTF acted as a national research facility to test advanced nuclear fuels, materials, components, systems, nuclear power plant operating and maintenance procedures, and active and passive reactor safety technologies; it also produced a large number of isotopes for medical and industrial users, generated tritium for the U.S. fusion research program, and participated in cooperative, international research work. Prior to the implementation of the reactor characterization program, a series of isothermal physics measurements were performed; this acceptance testing program consisted of a series of control rod worths, critical rod positions, subcriticality measurements, maximum reactivity addition rates, shutdown margins, excess reactivity, and isothermal temperature coefficient reactivity. The results of these experiments were of particular importance because they provide extensive information which can be directly applied to the design of large LMFBR’s. It should be recognized that the data presented in the initial report were evaluated only to the extent necessary to ensure that adequate data were obtained. Later reports provided further interpretation and detailed comparisons with prediction techniques. The conclusion of the isothermal physics measurements was that the FFTF nuclear characteristics were essentially as designed and all safety requirements were satisfied. From a nuclear point of view, the FFTF was qualified to proceed into power operation mode. The FFTF was completed in 1978 and first achieved criticality on February 9, 1980. Upon completion of the isothermal physics and reactor characterization programs, the FFTF operated for ten years from April 1982 to April 1992. Reactor operations of the FFTF were terminated and the reactor facility was then defueled, deactivated, and placed into cold standby condition. Deactivation of the reactor was put on hold from 1996 to 2000 while the U.S. Department of Energy examined alternative uses for the FFTF but then announced the permanent deactivation of the FFTF in December 2001. Its core support basket was later drilled in May 2005, so as to remove all remaining sodium coolant. On April 17, 2006, the American Nuclear Society designated the FFTF as a “National Nuclear Historic Landmark”.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗