SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry

This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Proper cooling-water chemistry is essential to preserving the DTL and CCL structures during their design lifetime. Appropriate water chemistry will protect cooling-water passages and brazed joints of the structure from erosion, corrosion, and fouling. The RCCS/QMCS DIW chemistry is managed by sidestreams built into the cooling loops; chemicals are not used. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended. During the evaluation period, the pH, dissolved oxygen, and water resistivity of the cooling water were observed. The data were collected by instruments mounted on mobile chemistry carts, which were moved from one RCCS/QMCS DIW skid to another. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time. It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similar regime, with a pH of about 7.5 (slightly alkaline), low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH. An RCCS/QMCS chemistry guidance document published in May 2017 describes and standardizes the methods and practices for water chemical treatment for the SNS RCCS and QMCS. It is very difficult to accurately measure the pH, dissolved oxygen, and water resistivity in highly pure water. Therefore, a regularly scheduled calibration program will be established for the instruments. Recommendations are given at the end of the report on how to run the RCCS/QMCS cooling water chemistry. Chemical analysis of the material trapped by the polishing loop prefilters is conducted twice a year. The analysis and its benefits are described in Chapter 9.

42 ENGINEERING↗

Method for rapid development of additive manufacturing parameter set

An apparatus includes a control system that defines a test part having multiple features of multiple feature types. The control system controls an additive manufacturing (AM) machine to print multiple copies of the test part, with each copy being printed according to a respective set of values used as printing parameters. A measurement system obtains a computed tomography (CT) image of each of the copies of the test part. An analysis system, for each of the plurality of feature types, analyzes the CT images to identify a selected set of values for the printing parameters. The analysis system identifies a portion of the CT image related to a first feature and assesses its density based on an average grayscale value. The AM machine is then controlled to print production parts according to, for each feature type of the production parts, the selected set of values for the printing parameters.

Bhattad, Pradeep↗

PC/104 Embedded IOCs at Jefferson Lab

Jefferson Lab has developed embedded IOCs based on PC/104 single board computers (SBC) for low level control systems. The PC/104 IOCs run EPICS on top of the RTEMS operating system. Two types of control system configurations are used in different applications, PC/104 SBC with commercial PC/104 I/O cards and PC/104 SBC with custom designed FPGA-based boards. RTEMS was built with CEXP shell to run on the PC/104 SBC. CEXP shell provides the function of dynamic object loading, which is similar to the widely used VxWorks operating system. Standard software configurations were setup for PC/104 IOC application development to provide a familiar format for new projects as well as ease the conversion of applications from VME based IOCs to PC/104 IOCs. Many new projects at Jefferson Lab are going to employ PC/104 SBCs as IOCs and some applications have already been running them for accelerator operations. The PC/104 - RTEMS IOC provides a free open source Real-Time Operating System (RTOS), low cost/maintenance, easily installed/ configured, flexible, and reliable solution for accelerator control and 12GeV Upgrade projects.

43 PARTICLE ACCELERATORS↗

Payload interposer (PIP) system and control software

A payload interposer (PIP) system and its control software provide an interface between a space vehicle and a payload. The PIP board facilitates power and communications between a command and data handler (CDH) of the space vehicle and the payload. A microcontroller of the PIP board may control operation of the payload, format messages between the space vehicle and the payload, and extract data from the payload for downlink via the space vehicle.

42 ENGINEERING↗

A Cybersecurity Event Simulation Tool and Platform

Digital Instrumentation and Control Systems (ICSs) have replaced analog control systems in nuclear power plants raising cybersecurity concerns. To study and understand the cybersecurity risks of nuclear power plants both high fidelity models of the plant physics and controllers must be created, and a framework to test and evaluate cyber security events must be established. A testing and evaluation framework of cybersecurity events consists of a method of interfering with control systems, a simulation of the plant network, and a network packet capture and recording tool. Sandia National Labs (SNL) in collaboration with the University of New Mexico’s Institute for Space and Nuclear Power Studies (UNM-ISNPS) is developing such a cybersecurity testing framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Alfalfa [SWR 18-17]

Alfalfa is a web based software service that implements a virtual building control system using the EnergyPlus simulation as a backend. Conventional building energy simulation is non interactive, meaning that a simulation is started and run to completion without any user input during the simulation. Alfalfa allows a client to start a building simulation, then interactively read sensor locations and dynamically command actuators in realtime. The Alfalfa web service conforms to the Project Haystack standard, which is a specification adopted by many building control system vendors. The service enables Haystack compliant control system vendors to test their control modules and algorithms without the need for a physical building or modifying their hardware and software, enabling faster and cheaper development cycles. Alfalfa has use cases beyond control system testing. One example is building fault detection, where physical building performance can be compared to simulated values in realtime, indicating where there may be a problem in the building. Another use case is informing predictive control systems, where near future events are simulated to premptively guide control decisions in the real building. This software is web based and designed to be self service. Users of Alfalfa can upload an OpenStudio building model and begin communicating with the simulated building without any advanced setup or configuration, as if they were communicating a real building control system. Behind the scenes, Alfalfa makes extensive use of Amazon Web Services, in order to scale from a very small number of users and buildings, to extremely large numbers in a cost effective way.

Benne, Kyle↗

Mesoscale system feedback-induced dissipation and noise suppression

A high-gain and low-noise negative feedback control (“feedback control”) system can detect charge transfer in quantum systems at room temperatures. The feedback control system can attenuate dissipative coupling between a quantum system and its thermodynamic environment. The feedback control system can be integrated with standard commercial voltage-impedance measurement system, for example, a potentiostat. In one aspect, the feedback control system includes a plurality of electrodes that are configured to electrically couple to a sample, and a feedback mechanism coupled to a first electrode of the plurality of electrodes. The feedback mechanism is configured to detect a potential associated with the sample via the first electrode. The feedback mechanism provides a feedback signal to the sample via a second electrode of the plurality of electrodes, the feedback signal is configured to provide excitation control of the sample at a third electrode of the plurality of electrode.

Gupta, Chaitanya↗

OPSAID improvements and capabilities report.

Process Control System (PCS) and Industrial Control System (ICS) security is critical to our national security. But there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. Sandia National Laboratories has performed the research and development of the OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy Office of Electricity Delivery and Energy Reliability (DOE/OE), to address this issue. OPSAID is an open-source architecture for PCS/ICS security that provides a design basis for vendors to build add-on security devices for legacy systems, while providing a path forward for the development of inherently-secure PCS elements in the future. Using standardized hardware, a proof-of-concept prototype system was also developed. This report describes the improvements and capabilities that have been added to OPSAID since an initial report was released. Testing and validation of this architecture has been conducted in another project, Lemnos Interoperable Security Project, sponsored by DOE/OE and managed by the National Energy Technology Laboratory (NETL).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A View on Future Building System Modeling and Simulation

This chapter presents what a future environment for building system modeling and simulation may look like. As buildings continue to require increased performance and better comfort, their energy and control systems are becoming more integrated and complex. We therefore focus in this chapter on the modeling, simulation and analysis of building energy and control systems. Such systems can be classified as heterogeneous systems because they involve multiple domains, such as thermodynamics, fluid dynamics, heat and mass transfer, electrical systems, control systems and communication systems. Also, they typically involve multiple temporal and spatial scales, and their evolution can be described by coupled differential equations, discrete equations and events. Modeling and simulating such systems requires a higher level of abstraction and modularisation to manage the increased complexity compared to what is used in today's building simulation programs. Therefore, the trend towards more integrated building systems is likely to be a driving force for changing the status quo of today's building simulation programs. Thischapter discusses evolving modeling requirements and outlines a path toward a future environment for modeling and simulation of heterogeneous building systems.A range of topics that would require many additional pages of discussion has been omitted. Examples include computational fluid dynamics for air and particle flow in and around buildings, people movement, daylight simulation, uncertainty propagation and optimisation methods for building design and controls. For different discussions and perspectives on the future of building modeling and simulation, we refer to Sahlin (2000), Augenbroe (2001) and Malkawi and Augenbroe (2004).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PJM Controller Testing with Prototypic PJM Nozzle Configuration

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities—pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter × 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method for controlling fiber growth in a laser heated pedestal growth system by controlling a laser power output, a pedestal feedstock rate of motion, and a draw rate

One or more embodiments relate to a method for controlling fiber growth and fiber diameter in a laser heated pedestal growth (LHPG) system so as to provide long, continuous single-crystal optical fibers of uniform diameter. The method generally provides three independent parameter feedback controls to control the molten zone height, laser power, and fiber drawing rates simultaneously in order to reduce the mismatch between instantaneous diameter changes and current diameter. The method permits the growth of fibers with non-uniform diameters along the fiber's length. The method also provides the capability to stop the LHPG system, remove the exhausted pedestal feedstock with a second pedestal feedstock, and restart the LHPG system to provide a continuous fiber.

Buric, Michael P.↗

Advanced, Integrated Control for Building Operations to Achieve 40% Energy Saving

We developed and demonstrated a software based integrated advanced building control platform called Smart Energy Box (SEB), which can coordinate building subsystem controls, integrate variety of energy optimization algorithms and provide proactive and collaborative energy management and control for building operations using weather and occupancy information. The integrated control system is a low cost solution and also features: Scalable component based architecture allows to build a solution for different building control system configurations with needed components; Open Architecture with a central data repository for data exchange among runtime components; Extendible to accommodate variety of communication protocols. Optimal building control for central loads, distributed loads and onsite energy resource; uses web server as a loosely coupled way to engage both building operators and building occupants in collaboration for energy conservation. Based on the open platform of SEB, we have investigated and evaluated a variety of operation and energy saving control strategies on Carnegie Mellon University Intelligent Work place which is equipped with alternative cooling/heating/ventilation/lighting methods, including radiant mullions, radiant cooling/heating ceiling panels, cool waves, dedicated ventilation unit, motorized window and blinds, and external louvers. Based on the validation results of these control strategies, they were integrated in SEB in a collaborative and dynamic way. This advanced control system was programmed and computer tested with a model of the Intelligent Workplace's northern section (IW n ). The advanced control program was then installed in the IW n control system; the performance was measured and compared with that of the state of the art control system to verify the overall energy savings great than 40%. In addition advanced human machine interfaces (HMI's) were developed to communicate both with building occupants and the building operator. Lifecycle cost analyses of the advanced building control were performed, and a Building Control System Guide was prepared and published to inform owners, architects, and engineers dealing with new construction or renovation of buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Hierarchical Security Architecture for Cyber-Physical Systems

Security of control systems is becoming a pivotal concern in critical national infrastructures such as the power grid and nuclear plants. In this paper, we adopt a hierarchical viewpoint to these security issues, addressing security concerns at each level and emphasizing a holistic cross-layer philosophy for developing security solutions. We propose a bottom-up framework that establishes a model from the physical and control levels to the supervisory level, incorporating concerns from network and communication levels. We show that the game-theoretical approach can yield cross-layer security strategy solutions to the cyber-physical systems.

47 OTHER INSTRUMENTATION↗

FN-DFE: Fuzzy-Neural Data Fusion Engine for Enhanced State-Awareness of Resilient Hybrid Energy System

Resiliency and improved state-awareness of modern critical infrastructures, such as energy production and industrial systems, is becoming increasingly important. As control systems become increasingly complex, the number of inputs and outputs increase. Therefore, in order to maintain sufficient levels of state-awareness, a robust system state monitoring must be implemented that correctly identifies system behavior even when one or more sensors are faulty. Furthermore, as intelligent cyber adversaries become more capable, incorrect values may be fed to the operators. To address these needs, this paper proposes a Fuzzy-Neural Data Fusion Engine (FN-DFE) for resilient state-awareness of control systems. The designed FN-DFE is composed of a three-layered system consisting of: 1) traditional threshold based alarms, 2) anomalous behavior detector using self-organizing fuzzy logic system, and 3) artificial neural network based system modeling and prediction. The improved control system state-awareness is achieved via fusing input data from multiple sources and combining them into robust anomaly indicators. In addition, the neural network based signal predictions are used to augment the resiliency of the system and provide coherent state-awareness despite temporary unavailability of sensory data. The proposed system was integrated and tested with a model of the Idaho National Laboratory’s (INL) hybrid energy system facility know as HYTEST. Experimental results demonstrate that the proposed FN-DFE provides timely plant performance monitoring and anomaly detection capabilities. It was shown that the system is capable of identifying intrusive behavior significantly earlier than conventional threshold based alarm systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SDN Project

The SDN Project completed on time and on budget and successfully accomplished 100% of the scope of work outlined in the original Statement of Project Objective (SOPO). The SDN Project formed an alliance between Ameren Corporation, University of Illinois Urbana- Champaign (UIUC), Pacific Northwest National Laboratories (PNNL), and Schweitzer Engineering Laboratories, Inc. (SEL). The objective of the SDN Project is to address Topic Area of Interest 2: Sustain critical energy delivery functions while responding to a cyber-intrusion under Funding Opportunity Announcement DE-FOA-0000797. The goal of the project is to design and commercially release technology that provides a method to sustain critical energy delivery functions during a cyber intrusion and to do this control system operators need the ability to quickly identify and isolate the affected network areas, and re-route critical information and control flows around. The objective of the SDN Project is to develop a Flow Controller that monitors, configures, and maintains the safe, reliable network traffic flows of all the local area networks (LANs) on a control system in the Energy sector. The SDN team identified the core attributes of a control system and produced an SDN flow controller that has the same core attributes enabling networks to be designed, configured and deployed that maximize the whitelisted, deny-bydefault and purpose built networks. This project researched, developed and commercially released technology that: Enables all field networks be to configured and monitored as if they are a single asset to be protected; Enables greatly improved and even precalculated response actions to reliability and cyber events; Supports pre-configured localized response actions tailored to provide resilience against failures and centralized response to cyber-attacks that improve network reliability and availability; Architecturally enables the right subject matter experts, who are usually the information technology and operational technology engineers, to be the ones centrally administering the technology and responding to events; Simplifies network configuration, improving deterministic Ethernet transport times, and providing instant visualization on where the communication circuits are and how all circuits are impacted when changes (e.g., configuration changes, failures or intrusions) happen, allowing operators to minimize downtime; and Improves the ability to identify deviations in network behavior resulting in detection and analysis of potential cyber intrusions and faster response times Results: This project has forever changed the way critical infrastructure networks are designed, secured, deployed and maintained. The cybersecurity and performance advantages achieved are significant, simply put traditional networking has been obsoleted while the team maintained Ethernet interoperability avoiding any legacy concerns. The team commercially released technology that accomplished all the cybersecurity goals outlined in the SOPO and completed it by executing the project management plan approved in the initial contract. The resulting Energy sector SDN flow controller model number is SEL-5056 and can be freely downloaded from the www.SELinc.com website. This technology not only improves the cybersecurity of control systems but has measured results that it improves the performance and reliability of the control system as well. This means the system owners can confidently apply it to their systems knowing that it will, “first do no harm” but actually improve the system as well. Success of the project is best measured by the sales and deployment of the technology. System owners in industrial, electric, defense, and oil and gas only months after commercial release have approved plans for deployment.

42 ENGINEERING↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.