Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Physics with WASA-at-COSY

The WASA detector facility is an internal experiment at the COoler SYnchrotron COSY in Juelich, Germany. The COSY accelerator provides proton and deuteron beams with momenta up to 3.7 GeV/c giving access to hadron physics including the strange quark sector. The WASA-at-COSY physics program focuses on light meson decays where rare decays are used to scrutinize symmetries and symmetry breaking. The structure of hadrons is probed with transition form factors and hadron spectroscopy while hadron dynamics is studied via reaction dynamics and few body reactions. Goals and status are reported with special emphasis on the meson Dalitz decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using the automata processor for fast pattern recognition in high energy physics experiments. A proof of concept

Here, we explore the Micron Automata Processor (AP) as a suitable commodity technology that can address the growing computational needs of pattern recognition in High Energy Physics (HEP) experiments. A toy detector model is developed for which an electron track confirmation trigger based on the Micron AP serves as a test case. Although primarily meant for high speed text-based searches, we demonstrate a proof of concept for the use of the Micron AP in a HEP trigger application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Likelihood-Based Particle Identification in the Short-Baseline Near Detector

Accurate particle identification is crucial in any high-energy physics experiment, allowing scientists to understand the unique interactions and mechanisms at play in a detector. In this project, I develop and study a new particle identification (PID) algorithm for the Short-Baseline Near Detector, a likelihood-based approach, different from out current $\chi^2$ method. A likelihood estimation offers a more physically motivated strategy for PID. The distribution random energy losses of charged particles traveling through a medium are described by the Vavilov probability density function. By using this model, we can account for random energy losses and construct likelihood functions specific to each particle type, potentially enabling a more accurate method for PID.

Vanderwaal, Sophia [U. Alabama, Huntsville] (ORCID↗

Search for new phenomena in three- or four-lepton events in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search with minimal model dependence for physics beyond the Standard Model in events featuring three or four charged leptons (3ℓ and 4ℓ, ℓ = e,μ) is presented. The analysis aims to be sensitive to a wide range of potential new-physics theories simultaneously. This analysis uses data from pp collisions delivered by the Large Hadron Collider at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV and recorded with the ATLAS detector, corresponding to the full Run 2 dataset of 139 fb -1 . The 3ℓ and 4ℓ phase space is divided into 22 event categories according to the number of leptons in the event, the missing transverse momentum, the invariant mass of the leptons, and the presence of leptons originating from a Z-boson candidate. These event categories are analysed independently for the presence of deviations from the Standard Model. No statistically significant deviations from the Standard Model predictions are observed. Upper limits for all signal regions are reported in terms of the visible cross-section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Noble Gas Excimer Detectors for Security and Safeguards Applications

Noble gas excimer detectors are a technology that is common in particle physics research and less common in applications for security and international safeguards. These detectors offer the capability to detect gammas with an energy resolution similar to NaI and to detect neutrons with good energy resolution as well. Depending on the noble gas selected and whether or not it is in a gaseous or liquid state, the sensitivity to gammas and neutrons can be tuned according to the needs of the application. All of this flexibility can be available at a significant cost saving over alternative technologies. This paper will review this detector technology and its applicability to security and safeguards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect search for dark matter in the Sun

If dark matter is be captured in the Sun and self-annihilate, evidence of this process might be observable on the Earth in form of a neutrinos, which are copiously produced in the annihilation process. We discuss a novel signature of dark matter annihilations in the Sun that originates from monoenergetic neutrinos produced in pion and kaon decays. Based on this signature we find competitive sensitivities for the detection of dark matter at present and next-generation neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mechanical stability of the CMS strip tracker measured with a laser alignment system

The CMS tracker consists of 206 m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from −25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements of tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗