Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

The Development of Vocational Vehicle Drive Cycles and Segmentation

Under a collaborative interagency agreement between the U.S. Environmental Protection Agency and the U.S Department of Energy (DOE), the National Renewable Energy Laboratory (NREL) performed a series of in-depth analyses to characterize the on-road driving behavior including distributions of vehicle speed, idle time, accelerations and decelerations, and other driving metrics of medium- and heavy-duty vocational vehicles operating within the United States. As part of this effort, NREL researchers segmented U.S. medium- and heavy-duty vocational vehicle driving characteristics into three distinct operating groups or clusters using real world drive cycle data collected at 1 Hz and stored in NREL's Fleet DNA database. The Fleet DNA database contains millions of miles of historical real-world drive cycle data captured from medium- and heavy vehicles operating across the United States. The data encompass data from existing DOE activities as well as contributions from valued industry stakeholder participants. For this project, data captured from 913 unique vehicles comprising 16,250 days of operation were drawn from the Fleet DNA database and examined. The Fleet DNA data used as a source for this analysis has been collected from a total of 30 unique fleets/data providers operating across 22 unique geographic locations spread across the United States. This includes locations with topology ranging from the foothills of Denver, Colorado, to the flats of Miami, Florida. The range of fleets, geographic locations, and total number of vehicles analyzed ensures results that include the influence of these factors. While no analysis will be perfect without unlimited resources and data, it is the researchers understanding that the Fleet DNA database is the largest and most thorough publicly accessible vocational vehicle usage database currently in operation. This report includes an introduction to the Fleet DNA database and the data contained within, a presentation of the results of the statistical analysis performed by NREL, review of the logistic model developed to predict cluster membership, and a discussion and detailed summary of the development of the vocational drive cycle weights and representative transient drive cycles for testing and simulation. Additional discussion of known limitations and potential future work are also included in the report content.

54 ENVIRONMENTAL SCIENCES↗

Use Attainability Analysis for Upper Sandia Canyon

This document presents a use attainability analysis (UAA) for the perennial segment of Upper Sandia Canyon, which is located within the Los Alamos National Laboratory (LANL) property near Los Alamos, New Mexico.1 This UAA is consistent with 20.6.4.15 New Mexico Administrative Code (NMAC) (New Mexico Environment Department [NMED] 2011c), which describes the perennial segment as “Sandia Canyon from Sigma Canyon upstream to LANL [National Pollutant Discharge Elimination System] NPDES outfall 001.” The perennial segment’s designated uses are coldwater aquatic life, livestock watering, wildlife habitat, and secondary contact. 40 Code of Federal Regulations (CFR) § 131.10(g) permits a state to remove a designated use that is not an existing use (as defined in 40 CFR §131.3), if a UAA demonstrates that naturally occurring pollutant concentrations prevent the attainment of the use or if physical conditions related to the natural features of the water body preclude the attainment of the aquatic life protection use. This UAA considers whether natural physical conditions in Upper Sandia Canyon, specifically air and/or water temperatures, prevent the designated aquatic life use water temperature limits (i.e., coldwater) from being attained in the perennial segment. The weight of evidence presented in this UAA supports the conclusion that, based on air-water temperature modeling and instream thermograph data, the coolwater aquatic life designated use is currently the attainable use. Accordingly, it is recommended that the coolwater aquatic life designated use replace the coldwater aquatic life designated use in the Upper Sandia Canyon assessment unit (AU).

54 ENVIRONMENTAL SCIENCES↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of Quantification in Non-Destructive Characterization of Radioactive Waste Packages -Introduction to the Ideas of a Currently Started Project - 20197

For the characterization of radioactive waste packages (e.g. 200-L drums) with inhomogeneous activity and density distributions preferably non-destructive methods like segmented gamma scanning and transmission measurements are applied. While the first is used for identification of the radioactive inventory, both are necessary for a reliable activity quantification. Although at nuclear facilities, segmented gamma scanner are state-of-the-art and are mostly equipped with a vertically moveable transmission source the combining of this data and further a-priori information improving accuracy in data estimation giving realistic, reliable and traceable uncertainty estimations are improvable. This challenge is tackled by a R and D project funded by the German Federal Ministry of Education and Research (BMBF). The boundary conditions for this project are (i) taking into account the typical instrumentation available at nuclear facilities, (ii) minimize the overall measurement time and (iii) combining data from emission and transmission measurements by Bayesian methods. For the R and D project, being still in its initial stage, the basic ideas, the data used for evaluation and the result of a preliminary investigation demonstrating the proof of principle are presented. Additionally, some first aspects on spatial resolution in emission and transmission measurements are addressed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Method to Automate the Segmentation of the GTV and ITV for Lung Tumors

Four-dimensional computed tomography (4D-CT) is a useful tool in the treatment of tumors that undergo significant motion. To fully utilize 4D-CT motion information in the treatment of mobile tumors such as lung cancer, autosegmentation methods will need to be developed. Using autosegmentation tools in the Pinnacle{sup 3} v8.1t treatment planning system, 6 anonymized 4D-CT data sets were contoured. Two test indices were developed that can be used to evaluate which autosegmentation tools to apply to a given gross tumor volume (GTV) region of interest (ROI). The 4D-CT data sets had various phase binning error levels ranging from 3% to 29%. The appropriate autosegmentation method (rigid translational image registration and deformable surface mesh) was determined to properly delineate the GTV in all of the 4D-CT phases for the 4D-CT data sets with binning errors of up to 15%. The ITV was defined by 2 methods: a mask of the GTV in all 4D-CT phases and the maximum intensity projection. The differences in centroid position and volume were compared with manual segmentation studies in literature. The indices developed in this study, along with the autosegmentation tools in the treatment planning system, were able to automatically segment the GTV in the four 4D-CTs with phase binning errors of up to 15%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analyses to support waste disposition of SNS Inner Reflector Plug

The Spallation Neutron Source Inner Reflector Plug (IRP) is scheduled for replacement. It reached end of life-time because of moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. In order to support the disposal of spent IRP, waste characterization analyses are performed. These analyses include an accurate estimate of the radionuclide inventory and the residual dose rate. Using this data, the package class is determined for the and appropriate containers for temporary storage and subsequent transport are assigned. Analyses are performed in four steps: a radiation transport analysis of the radiation environment for producing the flux and isotope production information using MCNPX, a multi-cell transmutation analysis based n CINDER90, the generation of decay gamma source terms, and the gamma transport analyses of the decay gammas arriving at residual dose rates again using MCNPX. . Due to the complexity of the geometry of the lower segment, transport analyses for the residual dose rate require elaborate work for the source terms definition.

Popova, Irina I.↗

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

42 ENGINEERING↗

Multitaper Magnitude‐Squared Coherence for Time Series With Missing Data: Understanding Oscillatory Processes Traced by Multiple Observables

To explore the hypothesis of a common source of variability in two time series, observers may estimate the magnitude-squared coherence (MSC), which is a frequency-domain view of the cross correlation. For time series that do not have uniform observing cadence, MSC can be estimated using Welch's overlapping segment averaging. However, multitaper has superior statistical properties to Welch's method in terms of the tradeoff between bias, variance, and bandwidth. The classical multitaper technique has recently been extended to accommodate time series with underlying uniform observing cadence from which some observations are missing. This situation is common for solar and geomagnetic data sets, which may have gaps due to breaks in satellite coverage, instrument downtime, or poor observing conditions. We demonstrate the scientific use of missing-data multitaper magnitude-squared coherence by detecting known solar mid-term oscillations in simultaneous, missing-data time series of solar Lyman α flux and geomagnetic Disturbance Storm Time index. Due to their superior statistical properties, we recommend that multitaper methods be used for all heliospheric time series with underlying uniform observing cadence.

Astro-statistics techniques (1886)↗

Cold Cap Bubble Topology

The feed composition of a high level nuclear waste (HLW) glass melter establishes the overall melting rate by influencing the thermo-physical and morphological properties of a relatively insulating cold cap layer over the molten phase. Data from X ray tomography of laboratory scale quenched cold caps provide insight into the distribution and morphology of bubbles, collectively known as primary foam, within this layer for various feed compositions at temperatures between 600°C and 1040°C. The images were digitally segmented to capture features of interest, then processed to obtain statistics that characterize the cold cap structure, including total pellet volume, void fraction, bubble radius distribution and morphology as a function of temperature. These statistics will be used to analyze the melting behavior of the waste glass as a function of silicate content. This temperature-dependent morphological data can be used in future investigations to synthetically generate cold cap structures for use in models of heat transfer through the upper layer of a HLW glass melter, with emphasis on nuclear waste remediation application at the Hanford Site in Washington, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NOvA Recent Results with Neutrino+Antineutrino Data

NOvA is a long-baseline neutrino oscillation experiment using Fermilab's 700 kW NuMI muon neutrino beam. Two functionally identical scintillator detectors are placed off the beam axis, separated by 810 km oscillation baseline. Both detectors have high active material fractions and are finely segmented allowing for precise identification and analysis of neutrino interactions. By observing both the disappearance of muon (anti)neutrinos and appearance of electron (anti)neutrinos in the beam, NOvA can impose constraints on the yet undetermined parameters of neutrino oscillation phenomenon, such as the neutrino mass ordering, CP violation and the octant of the large mixing angle. NOvA also studies neutral-current neutrino interactions, thus extending its scope beyond the standard three-flavor paradigm. This paper presents the latest NOvA results with the complete neutrino data sample up to date and first antineutrino data collected since February 2017.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Decayheatml

This code is designed to predict and analyze the decay heat generated in molten salt reactors (MSRs) using a hybrid approach that combines machine learning and segmented polynomial fitting. The accurate prediction of decay heat is essential for reactor safety and the optimization of spent fuel storage. The code operates through several key components: 1) Data Architecture: It incorporates a modular data architecture that handles various MSR-specific operational parameters such as power density, humidity content, and air ingress. These parameters are sampled using Sobol sequences to ensure comprehensive coverage of operational uncertainties. 2) Machine Learning Framework: The code employs a diverse set of machine learning models, including polynomial regression, decision trees, random forests, gradient boosting, support vector regression, k-nearest neighbors, multi-layer perceptrons, and symbolic regression. These models are trained to predict decay heat over a wide temporal range, from immediate shutdown up to 10,000 years. 3) Region-Optimized Training: The temporal domain is divided into multiple regions, each modeled separately to capture distinct decay heat characteristics across different time scales. This approach significantly improves the accuracy and interpretability of predictions. 4) Segmented Polynomial Interpretation (SPI): The SPI method translates machine learning predictions into piecewise polynomial equations. These equations are physically interpretable and can be directly integrated into existing engineering workflows and safety analyses. 5) Front-End Interfaces: The code includes both a Jupyter notebook interface for research development and a Streamlit web application for operational deployment. These interfaces allow users to interactively explore decay heat predictions, adjust operational parameters, and visualize results in real-time. 6) Applications: The framework supports various applications, including safety system validation and spent fuel container optimization. It enables real-time evaluation of worst-case decay heat scenarios, informing the design of passive safety systems and optimizing container designs for long-term storage. Overall, this code provides a robust, accurate, and user-friendly tool for predicting decay heat in MSRs, enhancing reactor safety, and optimizing spent fuel management.

Retamales, Mauricio Eduardo Tano [Idaho National L↗

Data for: Ultrasonic characterization of material heterogeneities in stainless steel parts fabricated by powder bed fusion

These are the raw ultrasonic waveform files and nanoindentation measurements for three additively manufactured 316L stainless steel components with different fabrication parameters. Each part's length is divided into four segmented regions where their fabrication energy densities change. Part V+ begins at 33 J/mm^3 and increases in energy density by 3 J/mm^3 with each segment. Part C remains at a constant 33 J/mm^3 throughout the part. Part V- begins at 33 J/mm^3 and decreases in energy density by 3 J/mm^3 with each segment. We have found that the ultrasonic waves in regions with higher energy densities will traverse more quickly, as shown by the shorter time of flight, and vice versa. Similarly, nanoindentation measurements of reduced modulus and hardness follow this trend. We have measured the direction in which the parts were fabricated (build direction) and the segmented regions that are perpendicular to the build direction (transverse directions). The build direction longitudinal wave velocity measurements are considerably lower than their transverse direction counterparts, indicating anisotropy between the two directions. In Part C, we have removed material from one of its surfaces and recorded its ultrasonic and nanoindentation measurements with each material removal iteration. Changes in the material properties are more prominent by nanoindentation, suggesting material heterogeneity between the part's surface and interior. The README.txt file has information on how to navigate the files and process the data.

Anisotropy↗

Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring

Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated inin vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone–tissue and air–tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and thein vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the nominal and measured cases, respectively. For air the corresponding figures were 0.991 and 0.993. Compared to an unattenuated reference image, the mean error in simulated PET uptake in the brain was 9.16% when AC maps derived from nominal trajectories was used, with errors in the SUV{sub max} for simulated lesions in the range of 7.17%–12.19%. Corresponding figures when AC maps derived from measured trajectories were used were 0.34% (mean error) and −0.21% to +1.81% (lesions). Conclusions: Eddy current artifacts in UTE imaging can be corrected for by measuring the true k-space trajectories during a calibration scan and using them in subsequent image reconstructions. This improves the accuracy of segmented PET attenuation maps derived from UTE sequences and subsequent PET reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

Mitigation of spatial nonstationarity with vision transformers

Spatial nonstationarity, the location variance of features’ statistical distributions, is ubiquitous in many natural settings. For example, in geological reservoirs rock matrix porosity varies vertically due to geomechanical compaction trends, in mineral deposits grades vary due to sedimentation and concentration processes, in hydrology rainfall varies due to the atmosphere and topography interactions, and in metallurgy crystalline structures vary due to differential cooling. Conventional geostatistical modeling workflows rely on the assumption of stationarity to be able to model spatial features for geostatistical inference. Nevertheless, this is often not a realistic assumption when dealing with nonstationary spatial data and this has motivated a variety of nonstationary spatial modeling workflows such as trend and residual decomposition, cosimulation with secondary features, and spatial segmentation and independent modeling over stationary subdomains. The advent of deep learning technologies has enabled new workflows for modeling spatial relationships. However, there is a paucity of demonstrated best practice and general guidance on mitigation of spatial nonstationarity with deep learning in the geospatial context. We demonstrate the impact of two common types of geostatistical spatial nonstationarity on deep learning model prediction performance and propose the mitigation of such impacts using self-attention (vision transformer) models. We demonstrate the utility of vision transformers for the mitigation of nonstationarity with relative errors as low as 10%, exceeding the performance of alternative deep learning methods such as convolutional neural networks. We establish best practice by demonstrating the ability of self-attention networks for modeling large-scale spatial relationships in the presence of commonly observed geospatial nonstationarity.

58 GEOSCIENCES↗

Atlas-Based Segmentation Improves Consistency and Decreases Time Required for Contouring Postoperative Endometrial Cancer Nodal Volumes

Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical target volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean {+-} standard deviation of 32 {+-} 9 vs. 23 {+-} 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 {+-} 3 vs. 21 {+-} 5 min (p = .003), 39 {+-} 12 vs. 30 {+-} 5 min (p = .055), and 29 {+-} 5 vs. 20 {+-} 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗