Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

ITER ECH Switch Design and Analysis

The electron cyclotron heating system (ECH) on ITER uses 24 evacuated microwave transmission lines carrying up to 1.4 MW of power each at 170 GHz to provide resonance heating of electrons in the ITER plasma and to enable plasma current drive. A critically important component in this system is the microwave switch that allows the microwaves to be directed from the gyrotrons to either dummy loads or between launchers in the upper and equatorial ports of the ITER tokamak while maintaining the vacuum integrity of the transmission lines. A moveable, water-cooled CuCrZr mirror is used to redirect the microwave transmission between two orthogonal waveguides. In this paper, we describe the optimized design of the mirror cooling passages produced by computational fluid dynamics analysis using ANSYS CFX with k-ε and k-ω shear stress transport turbulence models, and verify that the design parameters for mass flow rate, inlet temperature and pressure are adequate for good thermomechanical performance. Non-uniform heating of the mirror face from the incident microwaves induces deflections that should be less than 25 microns to meet the integrated transmission line efficiency specification. In the current 1.4 MW switch design, 0.03 kg/s of 36°C water at 10 bar inlet pressure can remove the 2660 W of ohmic heating in the mirror produced by the elliptical polarization power and maintain the surface temperature below 150°C. The water delta-T is 21°C with a 0.5 bar pressure drop in the mirror. Finally, the maximum predicted displacement in the center of the mirror face is less than 25 μm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SPS antenna element evaluation

The SPS transmitting array requires an architecture which will provide a low weight, high efficiency and high structural rigidity. Waveguide slot arrays constitute the most desirable option. Consequently, such an array was chosen for the SPS. Waveguide slot arrays offer high efficiency, uniform illumination, and are fairly lightweight. Bandwidths of such arrays are narrow, typically 1/2-2%. Although this does not directly impact the SPS, which transmits power at a single frequency of 2.45 GHz, the narrow bandwidth does constrain the thermal and mechanical tolerances of the antenna. The purpose of this program is to better define the electronic aspects of an SPS specific waveguide slot array. The specific aims of the program are as follows: (1) To build a full-scale half-module, 10 stick, array, the design parameters for which are to be determined analytical considerations tempered by experimental data on a single slotted radiating stick, (2) To experimentally evaluate the completed array with respect to antenna pattern, impedance and return loss; and (3) To measure swept transmission amplitude and phase to provide a data base for design of a receiving antenna.

Lunden, C. D.↗

A novel electro-hydraulic unit design based on a shaftless integration of an internal gear machine and a permanent magnet electric machine

In recent years, increasingly stringent emission regulations have spurred an electrification trend in off-highway vehicle technology. To address challenges such as the high cost of power electronics components, limited battery capacity, and the substantial modifications required for the vehicles, there is a pressing need to develop high-speed, cost-effective, compact, and efficient electro-hydraulic units capable of powering vehicle functions. In response to these demands, this paper introduces an innovative morphology for an electro-hydraulic unit and outlines the integration method for a crescent-type internal gear machine with a permanent magnet synchronous electric machine. The proposed morphology aims to minimize component count through a shaftless solution while incorporating a cooling system that utilizes the same working fluid as the hydraulic machine. The design approach utilizes a genetic algorithm optimization process to maximize overall energy efficiency and compactness. Insights gained from the optimization results shed light on the relationship between key design parameters and unit performance, enhancing the understanding of this electro-hydraulic unit. A prototype of the unit was manufactured and tested, demonstrating a volumetric efficiency ranging from 81 % to 97 % at a maximum rotational velocity of the pinion of 6000 rpm. Finally, these results validate both the morphology and the design approach, indicating the feasibility of designing compact electro-hydraulic units that leverage hydraulic machines with higher maximum rotational velocities than commercially available counterparts as a mean to enhance efficiency and compactness.

30 DIRECT ENERGY CONVERSION↗

Performance enhancement of thin film silicon solar cells based on distributed Bragg reflector and diffraction grating

The influence of various designing parameters were investigated and explored for high performance solar cells. Single layer grating based solar cell of 50 μm thickness gives maximum efficiency up to 24 % whereas same efficiency is achieved with the use of three bilayers grating based solar cell of 30 μm thickness. Remarkably, bilayer grating based solar cell design not only gives broadband absorption but also enhancement in efficiency with reduced cell thickness requirement. This absorption enhancement is attributed to the high reflection and diffraction from DBR and grating respectively. The obtained short-circuit current were 29.6, 32.9, 34.6 and 36.05 mA/cm{sup 2} of 5, 10, 20 and 30 μm cell thicknesses respectively. These presented designing efforts would be helpful to design and realize new generation of solar cells.

36 MATERIALS SCIENCE↗

Pit rim decomposition into multiple quantum dots on surfaces of epitaxial thin films grown on pit-patterned substrates

Here, we report results of dynamical simulations according to an experimentally validated surface morphological evolution model on the formation of regular arrays of quantum dot molecules (QDMs) consisting of 1D arrays of smaller interacting quantum dots (QDs). These QD arrays form along the sides of each pit rim on the surface of a coherently strained thin film epitaxially deposited on a semiconductor substrate, the surface of which consists of a periodic pattern of inverted prismatic pits with rectangular pit openings. We find that this complex QDM pattern results from the decomposition of the pit rim from a “quantum fortress” with four elongated QDs into four 1D arrays of multiple smaller QDs arranged along each side of the pit rim. Systematic parametric analysis indicates that varying the pit opening dimensions and the pit wall inclination directly impacts the number of QDs in the resulting QDM pattern, while varying the pit depth only affects the dimensions of the QDs in the nanostructure pattern. Therefore, the number, arrangement, and sizes of QDs in the resulting pattern of QDMs on the film surface can be engineered precisely by proper tuning of the pit design parameters. Our simulation results are supported by predictions of morphological stability analysis, which explains the pit rim decomposition into multiple QDs as the outcome of a tip-splitting instability and provides a fundamental characterization of the post-instability nanostructure pattern. Our theoretical findings can play a vital role in designing optimal semiconductor surface patterns toward enabling future nanofabrication technologies.

36 MATERIALS SCIENCE↗

Design study and performance analysis of a high-speed multistage variable-geometry fan for a variable cycle engine

A design technology study was performed to identify a high speed, multistage, variable geometry fan configuration capable of achieving wide flow modulation with near optimum efficiency at the important operating condition. A parametric screening study of the front and rear block fans was conducted in which the influence of major fan design features on weight and efficiency was determined. Key design parameters were varied systematically to determine the fan configuration most suited for a double bypass, variable cycle engine. Two and three stage fans were considered for the front block. A single stage, core driven fan was studied for the rear block. Variable geometry concepts were evaluated to provide near optimum off design performance. A detailed aerodynamic design and a preliminary mechanical design were carried out for the selected fan configuration. Performance predictions were made for the front and rear block fans.

Sullivan, T. J.↗

An analysis of strake vortex breakdown characteristics in relation to design features

This paper describes a water tunnel study of the vortex breakdown characteristics of a large number of analytically designed vortex strakes tested in combination with a moderate aspect ratio trapezoidal wing. A wide range of strake sizes and slenderness ratios are covered, and examples of the effects of the primary design parameters of size, span, and slenderness on the vortex breakdown characteristics are presented and analyzed in relation to the leading-edge suction distributions. Several examples of detailed planform shaping on strakes of the same general size and slenderness are shown from which it can be concluded that, consistent with the design criterion, those with leading-edge suction distributions which increase more rapidly near, and have a higher value at, the spanwise tip of the strake produce a more stable vortex.

Frink, N. T.↗

Evaluation of thick wall wave guide element

The SPS transmitting array requires an architecture which will provide a low weight, high efficiency and high structural rigidity. As noted above, waveguide slot arrays constitute the most desirable option. Consequently, such an array has been chosen for the SPS. Waveguide slot arrays offer high efficiency, uniform illumination, are are fairly lighweight. Bandwidths of such arrays are narrow, typically 1/2-2%. Although this does not directly impact the SPS, which transmits power at a single frequency of 2.45 GHz, the narrow bandwidth does constrain the thermal and mechanical tolerances of the antenna. The purpose of this program is to better define the electronic aspects of an SPS specific waveguide slot array. The specific aims of the program are as follows: (1) To build a full-scale half-module, 10 stick, array, the design parameters for which are to be determined by analytical considerations tempered by experimental data on a single slotted radiating stick, (2) To experimentally evaluate the completed array with respect to antenna pattern, impedance and return loss, and (3) To measure swept transmission amplitude and phase to provide a data base for design of a receiving antenna.

Nalos, E. J.↗

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗

Design optimization of an additively manufactured prototype recuperator for supercritical CO 2 power cycles

Supercritical CO 2 (sCO 2 ) power cycles are being developed due to their potential for high efficiency and reduced capital cost. It is necessary that these recuperators operate at high pressures and temperatures, up to 30 MPa and 900 K, with effectiveness values > 95% and pressure drops <1% to achieve high cycle efficiencies. Moreover, it is also necessary to have reasonable cost recuperators to control the capital costs of the sCO 2 power cycles. In this study, a Plate Pin-Fin (PPF) heat exchanger has been proposed as an sCO 2 recuperator. This preliminary recuperator design leverages capabilities enabled by additive manufacturing. Although the PPF design has characteristics similar to those of a plate heat exchanger, small diameter and relatively long fins are used to increase surface area, enhance heat transfer, and provide structural support for the partition plates that separate the fluid streams. Existing correlations for heat transfer and pressure drop were adapted for the PPF heat exchanger. These correlations were implemented in a 1D analytical model and used for the optimization of a 5-kW th high temperature recuperator for an indirect sCO 2 cycle by varying the design parameters to minimize the quantity of material required. A 3D conjugate heat transfer numerical simulations were conducted to validate the heat transfer and pressure loss correlations. A steepest descent method was used to minimize heat exchanger mass for a 5-kW prototype recuperator subject to a maximum specified pressure drop. Additionally, the design analysis indicated that an optimum PPF recuperator would be attained for the minimum allowable pin transverse spacing, minimum pin width, minimum pin height and near maximum cell aspect ratio. Moreover, at a low material requirement of 0.216 kg/kW and a pressure drop, which is almost five times lower than the allowable pressure drop design target, the optimized PPF heat exchanger has the high potential to be an alternative to a printed circuit heat exchanger, which is a conservative design basis for the current state-of-the-art sCO 2 recuperators.

42 ENGINEERING↗

Advancements and Opportunities for On-board 700 bar Compressed Hydrogen Tanks in the Progression towards the Commercialization of Fuel Cell Vehicles

Fuel cell vehicles are entering the automotive market with significant potential to reduce harmful greenhouse emissions, facilitate energy security, and increase efficiency while providing expected driving range and fill times. One of the challenges for successful commercialization is transitioning the on-board fuel system from liquid gasoline to compressed hydrogen gas. Storing high pressurized hydrogen requires a specialized structural pressure vessel, significantly different in function from a gasoline container. In addition, the lower hydrogen energy combined with highly efficient fuel cell still requires a storage vessel that is four times the volume of a gasoline tank. In the late 1990s, the industry first developed hydrogen tanks based on traditional type 3 and 4 compressed natural gas (CNG) tanks designed for 250 bar service. As fuel cell vehicles developed along with the need for greater driving range, the OEMs increased the hydrogen storage pressure to 350 bar and then to 700 bar, which is currently the industry norm. However, the 700 bar pressure vessels continued to be manufactured using the materials and the design approach from the CNG tank technologies. In 2012 the U.S. Department of Energy, Office of Fuel Cell Technologies initiated a project to develop Enhanced Materials and Design Parameters for Reducing the Cost of Hydrogen Storage Tanks. The project took a holistic approach to improving performance by investigating: 1) the cost tradeoff of reduced composite mass at 500 bar versus the added insulation cost for cold gas operation at 200K, 2) using hybrid fiber layups to refine the tank composite design, 3) increasing the composite translation efficiency by adding nano-reinforcing particles to the resin, and 4) substituting a lower cost alternate resin in the filament winding process. This paper summarizes the effectiveness of these design modifications and considers the outlook for on-board 700 bar compressed hydrogen tank systems to achieve the commercialization goals for fuel cell vehicles.

Hydrogen storage, carbon fiber composite, compo, a↗

Parametric Modeling Investigation of a Radially-Staged Low-Emission Aviation Combustor

Aviation gas-turbine combustion demands high efficiency, wide operability and minimal trace gas emissions. Performance critical design parameters include injector geometry, combustor layout, fuel-air mixing and engine cycle conditions. The present investigation explores these factors and their impact on a radially staged low-emission aviation combustor sized for a next-generation 24,000-lbf-thrust engine. By coupling multi-fidelity computational tools, a design exploration was performed using a parameterized annular combustor sector at projected 100% takeoff power conditions. Design objectives included nitrogen oxide emission indices and overall combustor pressure loss. From the design space, an optimal configuration was selected and simulated at 7.1, 30 and 85% part-power operation, corresponding to landing-takeoff cycle idle, approach and climb segments. All results were obtained by solution of the steady-state Reynolds-averaged Navier-Stokes equations. Species concentrations were solved directly using a reduced 19-step reaction mechanism for Jet-A. Turbulence closure was obtained using a nonlinear K-epsilon model. This research demonstrates revolutionary combustor design exploration enabled by multi-fidelity physics-based simulation.

design analysis↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and global optimization of high-efficiency solar thermal systems with tungsten cermets

Solar thermal, thermoelectric, and thermophotovoltaic (TPV) systems have high maximum theoretical efficiencies; experimental systems fall short because of losses by selective solar absorbers and TPV selective emitters. To improve these critical components, we study a class of materials known as cermets. While our approach is completely general, the most promising cermet candidate combines nanoparticles of silica and tungsten. We find that 4-layer silica-tungsten cermet selective solar absorbers can achieve thermal transfer efficiencies of 84.3% at 400 K, and 75.59% at 1000 K, exceeding comparable literature values. Three layer silica-tungsten cermets can also be used as selective emitters for InGaAsSb-based thermophotovoltaic systems, with projected overall system energy conversion efficiencies of 10.66% at 1000 K using realistic design parameters. The marginal benefit of adding more than 4 cermet layers is small (less than 0.26%, relative).

14 SOLAR ENERGY↗

A Silicon-Tungsten ECal with Integrated Electronics

We summarize recent R&D progress for a silicon-tungsten electromagnetic calorimeter (ECal) with integrated electronics, designed to meet the ILC physics requirements. A basic physics requirement for ILC detectors is that they provide excellent reconstruction of hadronic final states. This allows access to new physics which is complementary to the LHC. One statement for a requirement on jet reconstruction is that intermediate particles which decay into jets, such as W, Z, or top, can be identified and isolated. This places unprecedented requirements on 2-jet or 3-jet mass resolution, typically at the level of 3-5% using the PFA technique, which makes challenging demands on the calorimeters. The electromagnetic energy resolution is not expected to limit jet resolution using a PFA. However, particle separation - photon-photon and charged hadron-photon - is crucial. In addition, if one provides this kind of imaging calorimeter to meet the PFA needs, these same features will also be put to good use for reconstruction of specific tau decay modes (to enable final-state polarization measurement), to 'track' photons (even if originating from a vertex displaced from the interaction point), to track MIPS, and so forth. Figure 1 and Table 1 provide some context for our ECal design within the SiD detector concept, along with some main design parameters. More detail is included in the presentation.

43 PARTICLE ACCELERATORS↗

Overview of Recent Developments in Pellet Injection for ITER

Pellet injection is the primary fueling technique planned for core fueling of ITER burning plasmas. Also, the injection of relatively small pellets to purposely trigger rapid small edge localized modes (ELMs) has been proposed as a possible solution to the heat flux damage from larger natural ELMs likely to be an issue on the ITER divertor surfaces. The ITER pellet injection system is designed to inject pellets into the plasma through both inner and outer wall guide tubes. The inner wall guide tubes will provide high throughput pellet fueling while the outerwall guide tubes will be used primarily to trigger ELMs at a high frequency (>15 Hz). The pellet fueling rate ofeach injector is to be up to 120 Pa-m3/s, which will require the formation of solid D-T at a volumetric rate of ~1500 mm3/s. Two injectors are to be provided for ITER at the startup with a provision for up to six injectorsduring the D-T phase. The required throughput of each injector is greater than that of any injector built to date, and a novel twin-screw continuous extrusion system is being developed to meet the challenging design parameters. Status of the development activities will be presented, highlighting recent progress.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of defects in composite wind turbine blades – Part 3: A framework for treating defects as uncertainty variables for blade analysis

Abstract. Given that wind turbine blades are large structures, the use of low-cost composite manufacturing processes and materials has been necessary for the industry to be cost competitive. Since these manufacturing methods can lead to the inclusion of unwanted defects, potentially reducing blade life, the Blade Reliability Collaborative tasked the Montana State University Composites Group with assessing the effects of these defects. Utilizing the results of characterization and mechanical testing studies, probabilistic models were developed to assess the reliability of a wind blade with known defects. As such, defects were found to be best assessed as design parameters in a parametric probabilistic analysis allowing for establishment of a consistent framework to validate categorization and analysis. Monte Carlo simulations were found to adequately describe the probability of failure of composite blades with included defects. By treating defects as random variables, the approaches utilized indicate the level of conservation used in blade design may be reduced when considering fatigue. In turn, safety factors may be reduced as some of the uncertainty surrounding blade failure is reduced when analyzed with application specific data. Overall, the results indicate that characterization of defects and reduction of design uncertainty is possible for wind turbine blades.

Riddle, Trey W.↗

Effect of gaseous and solid simulated jet plumes on an 040A space shuttle launch configuration at m=1.6 to 2.2

The effect of plume-induced flow separation and aspiration effects due to operation of both orbiter and the solid rocket motors on a 0.019-scale model of the launch configuration of the Space Shuttle Vehicle is determined. Longitudinal and lateral-directional stability data were obtained at Mach numbers of 1.6, 2.0, and 2.2 with and without the engines operating. The plumes exiting from the engines were simulated by a cold-gas jet supplied by an auxiliary 200-atm air supply system and solid-body plume simulators. The aerodynamic effects produced by these two simulation procedures are compared. The parameters most significantly affected by the jet plumes are pitching moment, elevon control effectiveness, axial force, and orbiter wing loads. The solid rocket motor (SRM) plumes have the largest effect on the aerodynamic characteristics. The effect of the orbiter plumes in combination with the SRM plumes is also significant. Variations in the nozzle design parameters and configuration changes can reduce the jet plume-induced aerodynamic effects.

Dods, J. B., Jr.↗