Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Detection and Characterization of Underground Facilities by Stochastic Inversion and Modeling of Data from the New Generation of Synthetic Aperture Satellites (Final Report)

Many clandestine development and production activities can be conducted underground to evade surveillance. The purpose of the study reported here was to develop a technique to detect underground facilities by broad-area search and then to characterize the facilities by inversion of the collected data. This would enable constraints to be placed on the types of activities that would be feasible at each underground site, providing a basis the design of targeted surveillance and analysis for more complete characterization. Excavation of underground cavities causes deformation in the host material and overburden that produces displacements at the ground surface. Such displacements are often measurable by a variety of surveying or geodetic techniques. One measurement technique, Interferometric Synthetic Aperture Radar (InSAR), uses data from satellite-borne (or airborne) synthetic aperture radars (SARs) and so is ideal for detecting and measuring surface displacements in denied access regions. Depending on the radar frequency and the acquisition mode and the surface conditions, displacement maps derived from SAR interferograms can provide millimeter- to centimeter-level measurement accuracy on regional and local scales at spatial resolution of {approx}1-10 m. Relatively low-resolution ({approx}20 m, say) maps covering large regions can be used for broad-area detection, while finer resolutions ({approx}1 m) can be used to image details of displacement fields over targeted small areas. Surface displacements are generally expected to be largest during or a relatively short time after active excavation, but, depending on the material properties, measurable displacement may continue at a decreasing rate for a considerable time after completion. For a given excavated volume in a given geological setting, the amplitude of the surface displacements decreases as the depth of excavation increases, while the area of the discernable displacement pattern increases. Therefore, the ability to detect evidence for an underground facility using InSAR depends on the displacement sensitivity and spatial resolution of the interferogram, as well as on the size and depth of the facility and the time since its completion. The methodology development described in this report focuses on the exploitation of synthetic aperture radar data that are available commercially from a number of satellite missions. Development of the method involves three components: (1) Evaluation of the capability of InSAR to detect and characterize underground facilities ; (2) inversion of InSAR data to infer the location, depth, shape and volume of a subsurface facility; and (3) evaluation and selection of suitable geomechanical forward models to use in the inversion. We adapted LLNL's general-purpose Bayesian Markov Chain-Monte Carlo procedure, the 'Stochastic Engine' (SE), to carry out inversions to characterize subsurface void geometries. The SE performs forward simulations for a large number of trial source models to identify the set of models that are consistent with the observations and prior constraints. The inverse solution produced by this kind of stochastic method is a posterior probability density function (pdf) over alternative models, which forms an appropriate input to risk-based decision analyses to evaluate subsequent response strategies. One major advantage of a stochastic inversion approach is its ability to deal with complex, non-linear forward models employing empirical, analytical or numerical methods. However, while a geomechanical model must incorporate adequate physics to enable sufficiently accurate prediction of surface displacements, it must also be computationally fast enough to render the large number of forward realizations needed in stochastic inversion feasible. This latter requirement prompted us first to investigate computationally efficient empirical relations and closed-form analytical solutions. However, our evaluation revealed severe limitations in the ability of existing empirical and analytical forms to predict deformations from underground cavities with an accuracy consistent with the potential resolution and precision of InSAR data. We followed two approaches to overcoming these limitations. The first was to develop a new analytical solution for a 3D cavity excavated in an elastic half-space. The second was to adapt a fast parallelized finite element method to the SE and evaluate the feasibility of using in the stochastic inversion. To date we have demonstrated the ability of InSAR to detect underground facilities and measure the associated surface displacements by mapping surface deformations that track the excavation of the Los Angeles Metro system. The Stochastic Engine implementation has been completed and undergone functional testing.

58 GEOSCIENCES↗

Bearing Fault Detection and Wear Estimation Using Machine Learning

Unpredicted bearings failures can be costly and dangerous. Current methods have been examining the use of machine learning algorithms to automatically detect bearing faults. Vibration specialists must react daily, as the sheer number of bearings and the machines they operate are critical and any downtime will result in loss of productivity and endanger personal. The method presented in this paper utilizes a novel approach to detect and determine bearings fault diameters. The detection algorithm uses the cubic support vector machine (SVM) for high accuracy inner and outer race fault detection. After detecting the type of fault, the data is then passed through a second layer that uses a modified K-means clustering and a linear interpolation to accurately estimate the diameter of the fault that was detected.

42 ENGINEERING↗

Workshop Report for Next-Gen AI for Proliferation Detection: Accelerating the Development and Use of Explainability Methods to Design AI Systems Suitable for Nonproliferation Mission Applications

Artificial intelligence (AI) promises powerful new capabilities in an expansive array of applications. One area is proliferation detection, where AI can provide transformative tools to achieve objectives currently inaccessible using conventional methods. In particular, AI affords the opportunity to use new indicators and process massive amounts of heterogeneous data that can increase sensitivity to proliferant activities and push proliferation detection to the earliest possible stages. However, existing AI tools are not ready to achieve such potential, falling short in regard to some important considerations involved in proliferation detection. One crucial aspect that requires improvement is the explainability of the most powerful AI algorithms (i.e., understanding how the algorithms actually arrive at their conclusions)-the lack of which prevents widespread adoption in national security missions. The Data Science and AI portfolio within the National Nuclear Security Administration's Office of Defense Nuclear Nonproliferation Research and Development is driving the development of next-generation AI for proliferation detection through the expertise and work of the national laboratories and partners in academia. The "Next-Gen AI for Proliferation Detection: Accelerating the Development and Use of Explainability Methods to Design AI Systems Suitable for Nonproliferation Mission Applications" workshop aimed to further this objective. The meeting was held virtually on Sept. 15-16, 2020 and included more than 170 participants, primarily from the national laboratories with additional contributions from university researchers and mission partners. Each day included a keynote presentation, four technical presentations about cutting-edge research in explainability, and a panel to explore considerations in applying explainability and developing AI systems that can accelerate the transition of emerging AI technologies among partners and end users to solve critical mission questions. This report summarizes the Next-Gen AI for Proliferation Detection workshop's content and findings.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advancing Enhanced Raman Spectroscopy to Detect and Measure NOW Pheromones (CPRB 2022 proposal)

Insect sex pheromones are chemical compounds that insects release to attract their partners over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. These pheromone-based strategies can include monitoring, mating disruption, mass trapping, attract-and-kill and push-pull. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage by this pest. Just how mating disruption works is not fully established and likely varies across products and target species. For instance, the extent to which synthetic pheromones compete with natural pheromone is not well understood, or in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Furthermore, there may be specific conditions under which poor or impeded diffusion of synthetic pheromone diminishes the disruption effect, which could result in some males effectively locating females for reproduction. At the same time, many commercially available synthetic lures are also available, and growers have been effectively using them to track population development – although the attractive range of these lures remains unclear. That is, while pheromone lures can attract many moths, the relationship between trap capture and local populations, much less crop damage, remains unclear. Regardless of the emission source (aerosol puffers, meso emitters, lures etc.), we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. Raman spectroscopy (RS) may offer a means to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has a demonstrated capability to detect volatiles at extremely low concentrations. While other methods for detecting pheromones have proven to be successful, such analytical methods like mass spectrometry (MS) gas chromatography (GC) require sampling in the fields and are not real-time. Other methods such as EAG/ EAD are also invasive (use antennas) but are of course valuable. Opto-electronic, micro and nano sensors just recently enticed interest. We fall in this latter category, proposing the use of optical spectroscopy (Raman) in a fiber aided by nanostructures to provide a chemical fingerprint without transductions and in real-time (i.e. no sampling). To date, we have been able to generate Raman signatures for the main chemicals in synthetic pheromones (a first for science, to the best of our knowledge), observe their trends at different concentrations, and also provide a clear distinction of such signatures in mixed samples via Principal Component Analysis (PCA) – all of which strengthens our conclusions on the ability of RS to detect emissions in more realistic conditions. We also established processes to enhance the detection sensitivity via preconcentration with Solid Phase Micro Extraction (SPME) fibers and Surface Enhanced Raman Spectroscopy (SERS) to increase the overall optical signals. Furthermore, we explored limitations and requirements for detecting from dispensers, lures, or live moths, including Dept. of Energy and CA State regulatory approvals. Finally, we setup some of our first “orchard in a box” experiments to measure pheromone diffusion along with developing appropriate models.

42 ENGINEERING↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Updated Application of Frequency of Detection Methods for the INL Site Ambient Air Monitoring Network

This report presents a quantitative assessment of the current INL Site air monitoring network using frequency of detection (FD) methods. The first assessment of the INL network was performed in 2015 and made recommendations for improving the network. As a result of changes made in response to the recommendations and the addition of new source locations, the network was modified and reassessed in 2017. Since 2017, administration of the air sampling program has been consolidated under one contractor, which resulted in additional changes to the network (sampler numbers and locations) and changes in radionuclide detection levels. As a result of these changes and others, an updated assessment of the INL Site ambient air monitoring network was performed. The same two exposure scenarios used in previous assessments were used for this assessment: a resident scenario and a shepherd/rancher scenario. The resident was assumed to be continuously present at their residence/business/farm operation outside the INL Site boundary while the shepherd/rancher was assumed to be present 24-hours at the nearest INL grazing allotment boundary in each of the 22.5-degree sectors along the sector centerline from each source. Updates to both the resident and shepherd/rancher receptor locations were included. Other changes include updates to flow rates for stack sources, expansion of the list of important radionuclides based on the most recent National Emission Standards for Hazardous Pollutants (NESHAPs) analysis, and updated dose coefficients. The assessment was conducted to determine whether the current INL monitoring network is capable of detecting releases of important radionuclides from INL Site sources that have the potential to exceed a conservative dose threshold for the two exposure scenarios. The assessment revealed that for the resident scenario, the current network meets the desired performance objective (FD = 95%) for all radionuclides and sources except for Cl-36 from the TRA-770 stack (94.4%). For the shepherd/rancher scenario, the FD performance objective is met for all radionuclides and sources except tritium from MFC-774 and TAN 679 (91% for both). An investigation of reported emissions for the past three years revealed that Cl 36 is not emitted from TRA-770, and routine tritium emissions from MFC-774 and TAN-679 are very small and the sources are likely incapable of emitting enough tritium to cause a release that should be detectable by the monitoring network. This assessment is based on a conservative dose threshold. This coupled with fact that the FD for Cl 36 is only slightly less than the performance objective and Cl-36 is not emitted from TRA-770, modifying the network (i.e. adding another sampler, increasing sampler flow rate, moving samplers) to meet the 95% performance objective for this radionuclide/source/receptor scenario is not warranted. Similarly, because tritium emissions from MFC-774 and TAN-679 are very small and these two sources are likely incapable of causing a dose due to tritium release that should be detectable by the network, modifications to increase tritium detection for these sources is also unwarranted at this time. However, if it is required to meet the performance objective for tritium for all sources and receptor scenarios, additional analysis determined the FD could be raised from 91% to > 99% for both sources by adding two tritium samplers to the network.

61 RADIATION PROTECTION AND DOSIMETRY↗

Discrimination Report: A Multisensor system for detection andcharacterization of UXO, ESTCP Project MM-0437,

The Berkeley UXO Discriminator (BUD) is an optimally designed active electromagnetic system that not only detects but also characterizes UXO. The performance of the system is governed by a target size-depth curve. BUD was designed to detect UXO in the 20 mm to 155 mm size range for depths between 0 and 1.5 m, and to characterize them in a depth range from 0 to 1.1 m. The system incorporates three orthogonal transmitters and eight pairs of differenced receivers. Eight receiver coils are placed horizontally along the two diagonals of the upper and lower planes of the two horizontal transmitter loops. These receiver coil pairs are located on symmetry lines through the center of the system and each pair sees identical fields during the on-time of the pulse in all of the transmitter coils. They are wired in opposition to produce zero output during the on-time of the pulses in three orthogonal transmitters. Moreover, this configuration dramatically reduces noise in the measurements by canceling the background electromagnetic fields (these fields are uniform over the scale of the receiver array and are consequently nulled by the differencing operation), and by canceling the noise contributed by the tilt motion of the receivers in the Earth's magnetic field, and greatly enhances receiver sensitivity to the gradients of the target response. BUD is mounted on a small cart to assure system mobility. System positioning is provided by a Real Time Kinematic (RTK) GPS receiver. The system has two modes of operation: (1) the search mode, in which BUD moves along a profile and exclusively detects targets in its vicinity providing target depth and horizontal location, and (2) the discrimination mode, in which BUD is stationary above a target, and determines three discriminating polarizability responses together with the object location and orientation from a single position of the system. The detection performance of the system is governed by a size-depth curve shown in Figure 2. This curve was calculated for BUD assuming that the receiver plane is 0.2 m above the ground. Figure 2 shows that, for example, BUD can detect an object with 0.1 m diameter down to the depth of 0.9 m with a depth uncertainty of 10%. Any objects buried at a depth of more than 1.3 m will have a low probability of detection. The discrimination performance of the system is governed by a size-depth curve shown in Figure 3. Again, this curve was calculated for BUD assuming that the receiver plane is 0.2 m above the ground. Figure 3 shows that, for example, BUD can determine the polarizability of an object with 0.1 m diameter down to the depth of 0.63 m with polarizability uncertainty of 10%. Any objects buried at the depth more than 0.9 m will have a low discrimination probability. Object orientation estimates and equivalent dipole polarizability estimates used for large and shallow UXO/scrap discrimination are more problematic as they are affected by higher order (non-dipole) terms induced in objects due to source field gradients along the length of the objects. For example, a vertical 0.4 m object directly below the system needs to be about 0.90 m deep for perturbations due to gradients along the length of the object to be of the order of 20% of the uniform field object response. Similarly, vertical objects 0.5 m, and 0.6 m long need to be 1.15 m, and 1.42 m, respectively, below the system. For horizontal objects the effect of gradients across the object diameter are much smaller. For example, 155 mm and 105 mm projectiles need to be only 0.30 m, and 0.19 m, respectively, below the system. A polarizability index (in cm{sup 3}), which is an average value of the product of time (in seconds) and polarizability rate (in m{sup 3}/s) over the 34 sample times logarithmically spaced from 143 to 1300 {micro}s, and three polarizabilities, can be calculated for any object. We used this polarizability index to decide when the object is in a uniform source field. Objects with the polarizability index smaller than 600 cm{sup 3} and deeper than 1.8 m below BUD, or smaller than 200 cm{sup 3} and deeper than 1.35 m, or smaller than 80 cm{sup 3} and deeper than 0.90 m, or smaller than 9 cm{sup 3} and deeper than 0.20 m below BUD are sufficiently deep that the effects of vertical source field gradients should be less than 15%. All other objects are considered large and shallow objects. At the moment, interpretation software is available for a single object only. In case of multiple objects the software indicates the possible presence of metallic objects but is unable to provide characteristics of each individual object.

54 ENVIRONMENTAL SCIENCES↗

Worlds Beyond: A Strategy for the Detection and Characterization of Exoplanets

This report is a comprehensive study of the search for and study of planets around other stars (exoplanets). The young but maturing field of exoplanets is perhaps one of the most compelling fields of study in science today--both because of the discoveries made to date on giant planets around other stars, and because the detection of planets just like our Earth ('Earth analogs') is at last within reach technologically. In the Report we outline the need for a vigorous research program in exoplanets to understand our place in the cosmos: whether planets like our home Earth are a common or rare outcome of cosmic evolution. The strategy we developed is intended to address the following fundamental questions, in priority order, within three distinct 5-yr long phases, over a 15 year period: (1) What are the physical characteristics of planets in the habitable zones around bright, nearby stars? (2) What is the architecture of planetary systems? (3) When, how and in what environments are planets formed? The Report recommends a two-pronged strategy for the detection and characterization of planets the size of the Earth. For stars much less massive and cooler than our Sun (M-dwarfs), existing ground-based techniques including radial velocity and transit searches, and space-based facilities both existing and under development such as Spitzer and JWST, are adequate for finding and studying planets close to the mass and size of the Earth. Conducted in parallel with the M-dwarf strategy is one for the more challenging observations of the hotter and brighter F, G, and K stars, some of which are very close in properties to our Sun, in which the frequency of Earth-sized planets is assessed with Corot and Kepler, but new space missions are required for detection and study of specific Earth-mass and Earth-sized objects. Our Task Force concludes that the development of a space-based astrometric mission, narrowly-focused to identify specific nearby stars with Earth-mass planets, followed by direct detection and study via a spaceborne coronagraph/occulter or interferometric mission, is the most robust approach to pursue. Ground and space-based microlensing programs pursued in parallel would provide complementary information on planetary system architectures on galactic scales. The program for F, G, and K stars must be preceded, at the beginning of the strategy, by broad yet detailed technical assessments to determine whether the astrometric and direct detection technologies will be ready in the time frames envisioned (the second and third 5-yr periods, respectively). Also measurement of dust around nearby candidate stars must be undertaken early to determine whether typical systems are clean enough to make direct detection feasible. Alternative strategies are discussed should problems arise in any of these areas. Finally, the Task Force lays out recommended programs in ground-based observations of larger planets, of planet-forming disks, and theoretical and laboratory studies crucial to interpreting and understanding the outcome of the planet search and characterization observations.

99 GENERAL AND MISCELLANEOUS↗

Development of a Safeguards Verification Method and Instrument to Detect Pin Diversion from Pressurized Water Reactor (PWR) Spent Fuel Assemblies Phase I Study

A novel methodology to detect diversion of spent fuel from Pressurized Water Reactors (PWR) has been developed in order to address a long unsolved safeguards verification problem for international safeguards community such as International Atomic Energy Agency (IAEA) or European Atomic Energy Community (EURATOM). The concept involves inserting tiny neutron and gamma detectors into the guide tubes of a spent fuel assembly and measuring the signals. The guide tubes form a quadrant symmetric pattern in the various PWR fuel product lines and the neutron and gamma signals from these various locations are processed to obtain a unique signature for an undisturbed fuel assembly. Signatures based on the neutron and gamma signals individually or in a combination can be developed. Removal of fuel pins from the assembly will cause the signatures to be visibly perturbed thus enabling the detection of diversion. All of the required signal processing to obtain signatures can be performed on standard laptop computers. Monte Carlo simulation studies and a set of controlled experiments with actual commercial PWR spent fuel assemblies were performed and validated this novel methodology. Based on the simulation studies and benchmarking measurements, the methodology developed promises to be a powerful and practical way to detect partial defects that constitute 10% or more of the total active fuel pins. This far exceeds the detection threshold of 50% missing pins from a spent fuel assembly, a threshold defined by the IAEA Safeguards Criteria. The methodology does not rely on any operator provided data like burnup or cooling time and does not require movement of the fuel assembly from the storage rack in the spent fuel pool. A concept was developed to build a practical field device, Partial Defect Detector (PDET), which will be completely portable and will use standard radiation measuring devices already in use at the IAEA. The use of the device will not require any information provided by the operator or any prior knowledge of the spent fuel assembly. The device can also be operated without any movement of the spent fuel from its storage position. Based on parametric studies conducted via computer simulation, the device should be able to detect diversion of as low as ten percent of the missing or replaced fuel from an assembly regardless of the location of the missing fuel within the assembly, of the cooling time, initial fuel enrichment or burnup levels. Conditions in the spent fuel pool such as clarity of the water or boron content are also not issues for this device. The shape of the base signature is principally dependent on the layout of the guide tubes in the various types of PWR fuel assemblies and perturbations in the form of replaced fuel pins will distort this signature. These features of PDET are all unique and overcome limitation and disadvantages presented by currently used devices such as the Fork detector or the Cerenkov Viewing Device. Thus, this device when developed and tested could fill an important need in the safeguards area for partial defect detection, a technology that the IAEA has been seeking for the past few decades.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Viral RNA testing and automation on the bead-based CBNE detection microsystem.

We developed prototype chemistry for nucleic acid hybridization on our bead-based diagnostics platform and we established an automatable bead handling protocol capable of 50 part-per-billion (ppb) sensitivity. We are working towards a platform capable of parallel, rapid (10 minute), raw sample testing for orthogonal (in this case nucleic acid and immunoassays) identification of biological (and other) threats in a single sensor microsystem. In this LDRD we developed the nucleic acid chemistry required for nucleic acid hybridization. Our goal is to place a non-cell associated RNA virus (Bovine Viral Diarrhea, BVD) on the beads for raw sample testing. This key pre-requisite to showing orthogonality (nucleic acid measurements can be performed in parallel with immunoassay measurements). Orthogonal detection dramatically reduces false positives. We chose BVD because our collaborators (UC-Davis) can supply samples from persistently infected animals; and because proof-of-concept field testing can be performed with modification of the current technology platform at the UC Davis research station. Since BVD is a cattle-prone disease this research dovetails with earlier immunoassay work on Botulinum toxin simulant testing in raw milk samples. Demonstration of BVD RNA detection expands the repertoire of biological macromolecules that can be adapted to our bead-based detection. The resources of this late start LDRD were adequate to partially demonstrate the conjugation of the beads to the nucleic acids. It was never expected to be adequate for a full live virus test but to motivate that additional investment. In addition, we were able to reduce the LOD (Limit of Detection) for the botulinum toxin stimulant to 50 ppb from the earlier LOD of 1 ppm. A low LOD combined with orthogonal detection provides both low false negatives and low false positives. The logical follow-on steps to this LDRD research are to perform live virus identification as well as concurrent nucleic acid and immunoassay detection.

59 BASIC BIOLOGICAL SCIENCES↗

Annual Groundwater Detection Monitoring Report for the Idaho CERCLA Disposal Facility (2008)

This report presents the data collected for groundwater detection monitoring at the Idaho Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Disposal Facility (ICDF) during calendar year 2008. The detection-monitoring program developed for the ICDF groundwater-monitoring wells is applicable to six wells completed in the uppermost portion of the Snake River Plain Aquifer - five wells downgradient of the ICDF and one well upgradient. The ICDF detection-monitoring program was established to meet the substantive requirements of Title 40 Code of Federal Regulations (CFR) Parts 264.97 and 264.98, which are applicable or relevant and appropriate requirements under CERCLA. Semiannual groundwater samples were collected and analyzed for indicator parameters in March and September. The indicator parameters focus on constituents that are found in higher concentrations in ICDF leachate than in groundwater (bicarbonate alkalinity, sulfate, U-233, U-234, and U-238). The only detection monitoring limits that were exceeded were for bicarbonate alkalinity. Bicarbonate alkalinity is naturally occurring in groundwater. Bicarbonate alkalinity found in ICDF detection monitoring wells is not a result of waste migration from the ICDF landfill or the evaporation pond. The U.S. Department of Energy will continue with detection monitoring for the ICDF, which is semiannual sampling for indicator parameters.

54 ENVIRONMENTAL SCIENCES↗

Applications of a single-molecule detection in early disease diagnosis and enzymatic reaction study

Various single-molecule techniques were utilized for ultra-sensitive early diagnosis of viral DNA and antigen and basic mechanism study of enzymatic reactions. DNA of human papilloma virus (HPV) served as the screening target in a flow system. Alexa Fluor 532 (AF532) labeled single-stranded DNA probes were hybridized to the target HPV-16 DNA in solution. The individual hybridized molecules were imaged with an intensified charge-coupled device (ICCD) in two ways. In the single-color mode, target molecules were detected via fluorescence from hybridized probes only. This system could detect HPV-16 DNA in the presence of human genomic DNA down to 0.7 copy/cell and had a linear dynamic range of over 6 orders of magnitude. In the dual-color mode, fluorescence resonance energy transfer (FRET) was employed to achieve zero false-positive count. We also showed that DNA extracts from Pap test specimens did not interfere with the system. A surface-based method was used to improve the throughput of the flow system. HPV-16 DNA was hybridized to probes on a glass surface and detected with a total internal reflection fluorescence (TIRF) microscope. In the single-probe mode, the whole genome and target DNA were fluorescently labeled before hybridization, and the detection limit is similar to the flow system. In the dual-probe mode, a second probe was introduced. The linear dynamic range covers 1.44-7000 copies/cell, which is typical of early infection to near-cancer stages. The dual-probe method was tested with a crudely prepared sample. Even with reduced hybridization efficiency caused by the interference of cellular materials, we were still able to differentiate infected cells from healthy cells. Detection and quantification of viral antigen with a novel single-molecule immunosorbent assay (SMISA) was achieved. Antigen from human immunodeficiency virus type 1(HIV-1) was chosen to be the target in this study. The target was sandwiched between a monoclonal capture antibody and a polyclonal detector antibody. The capture antibody was covalently immobilized on modified glass slides. The detector antibody was conjugated with AF532 labeled secondary antibody prior to being used as probe for the antigen. Imaging was performed with a TIRF system. This technique is demonstrated for detecting HIV-1 p24 antigen down to 0.1 pg/mL with a dynamic range of over 4 orders of magnitude. A Langmuir isotherm fit the molecule count dependence on the target concentration. The results also showed that neither sensitivity nor dynamic range was affected by the biological matrix. SMISA is therefore a promising approach for the early diagnosis of virus-induced diseases. Single-molecule enzymatic kinetics and enantioselectivity were monitored in real time by using TIRF microscopy. AF532 labeled poly-L-lysine (PLL) or poly-D-lysine (PDL) was covalently immobilized on a dithiobis (succinimidyl undecanoate) self-assembled monolayer (DSU SAM). Chain shortening due to enzymatic hydrolysis resulted in the reduction of the individual fluorescence intensities. A broad distribution was obtained when 100 single-molecule half-lives were analyzed. However, the detailed hydrolysis process involved also a long-lived component and an induction period that varied significantly among molecules. Charge and steric heterogeneity at the surface are responsible for these features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensor integration study for a shallow tunnel detection system.

During the past several years, there has been a growing recognition of the threats posed by the use of shallow tunnels against both international border security and the integrity of critical facilities. This has led to the development and testing of a variety of geophysical and surveillance techniques for the detection of these clandestine tunnels. The challenges of detection of these tunnels arising from the complexity of the near surface environment, the subtlety of the tunnel signatures themselves, and the frequent siting of these tunnels in urban environments with a high level of cultural noise, have time and again shown that any single technique is not robust enough to solve the tunnel detection problem in all cases. The question then arises as to how to best combine the multiple techniques currently available to create an integrated system that results in the best chance of detecting these tunnels in a variety of clutter environments and geologies. This study utilizes Taguchi analysis with simulated sensor detection performance to address this question. The analysis results show that ambient noise has the most effect on detection performance over the effects of tunnel characteristics and geological factors.

58 GEOSCIENCES↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Deep Learning and Photogrammetric Reconstruction for Automated Crack Detection and Dimensional Measurement in Mining Operations

Surface crack detection and dimensional measurement at active mining sites present significant safety and operational challenges. Manual inspection methods are labor-intensive, spatially incomplete, and expose personnel to hazardous environments, while existing automated approaches have been developed primarily for concrete civil infrastructure and have not been validated on the complex, variable surfaces characteristic of mining environments. This dissertation presents an automated pipeline that integrates deep learning semantic segmentation with Structure-from-Motion photogrammetry to detect surface cracks and measure their aperture, length, and vertical displacement from standard RGB imagery acquired during routine Uncrewed Aerial Vehicle (UAV) survey operations, without requiring additional sensor hardware or manual measurement. The pipeline combines a U-Net architecture with an EfficientNet-B0 encoder, pretrained on the SDNET2018 concrete crack dataset and fine-tuned on a mining-specific dataset spanning laboratory concrete specimens, coal refuse impoundment embankments, and post-blast limestone quarry benches. Photogrammetric reconstruction is performed using COLMAP Structure-from-Motion and Multi-View Stereo, with crack segmentation masks projected into the reconstructed point cloud to enable three-dimensional vertical displacement measurement through local plane fitting and bimodal surface detection. The pipeline was validated across 36 controlled laboratory specimens at three imaging distances and four vertical displacement levels, achieving aperture measurement RMSE of 0.047 cm and R² of 0.954, and vertical displacement RMSE of 0.140 cm and R² of 0.966, against independent caliper measurements. Field application at a coal refuse impoundment in southwestern Pennsylvania detected 71 crack components across the embankment crest, with a dominant longitudinal crack exhibiting aperture values reaching 28 cm and a 95th percentile vertical displacement of 35.53 cm, consistent in magnitude and spatial distribution with simultaneously acquired LiDAR-derived estimates. Application across four post-blast limestone quarry bench datasets in California successfully characterized blast-induced fracture networks at ground sampling distances ranging from 0.59 to 1.23 cm/pixel, with detected crack geometries physically consistent with observable surface conditions at each site. The results demonstrate that deep learning-based crack detection and photogrammetric measurement can be integrated into routine UAV inspection workflows at mining sites, providing repeatable, scalable, and quantitative crack characterization across surface types, crack scales, and displacement magnitudes not previously addressed in the literature. The pipeline requires no dedicated surveying equipment beyond the UAV platforms already deployed at mine sites for survey and monitoring purposes, supporting practical adoption within existing operational workflows.

Crack detection, Dimensional Measurement↗

MINIMAL PROSPECTS FOR RADIO DETECTION OF EXTENSIVE AIR SHOWERS IN THE ATMOSPHERE OF JUPITER

One possible approach for detecting ultra-high-energy cosmic rays and neutrinos is to search for radio emission from extensive air showers created when they interact in the atmosphere of Jupiter, effectively utilizing Jupiter as a particle detector. We investigate the potential of this approach. For searches with current or planned radio telescopes we find that the effective area for detection of cosmic rays is substantial (∼3 × 10{sup 7} km{sup 2}), but the acceptance angle is so small that the typical geometric aperture (∼10{sup 3} km{sup 2} sr) is less than that of existing terrestrial detectors, and cosmic rays also cannot be detected below an extremely high threshold energy (∼10{sup 23} eV). The geometric aperture for neutrinos is slightly larger, and greater sensitivity can be achieved with a radio detector on a Jupiter-orbiting satellite, but in neither case is this sufficient to constitute a practical detection technique. Exploitation of the large surface area of Jupiter for detecting ultra-high-energy particles remains a long-term prospect that will require a different technique, such as orbital fluorescence detection.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIO DETECTION PROSPECTS FOR A BULGE POPULATION OF MILLISECOND PULSARS AS SUGGESTED BY FERMI-LAT OBSERVATIONS OF THE INNER GALAXY

The dense stellar environment of the Galactic center has been proposed to host a large population of as-yet undetected millisecond pulsars (MSPs). Recently, this hypothesis has found support in an analysis of gamma-rays detected using the Large Area Telescope onboard the Fermi satellite, which revealed an excess of diffuse GeV photons in the inner 15 deg about the Galactic center. The excess can be interpreted as the collective emission of thousands of MSPs in the Galactic bulge, with a spherical distribution strongly peaked toward the Galactic center. In order to fully establish the MSP interpretation, it is essential to find corroborating evidence in multi-wavelength searches, most notably through the detection of radio pulsations from individual bulge MSPs. Based on globular cluster observations and gamma-ray emission from the inner Galaxy, we investigate the prospects for detecting MSPs in the Galactic bulge. While previous pulsar surveys failed to identify this population, we demonstrate that upcoming large-area surveys of this region should lead to the detection of dozens of bulge MSPs. Additionally, we show that deep targeted searches of unassociated Fermi sources should be able to detect the first few MSPs in the bulge. The prospects for these deep searches are enhanced by a tentative gamma-ray/radio correlation that we infer from high-latitude gamma-ray MSPs. Such detections would constitute the first clear discoveries of field MSPs in the Galactic bulge, with far-reaching implications for gamma-ray observations, the formation history of the central Milky Way, and strategy optimization for future deep radio pulsar surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

On the Prospects of Gamma-Ray Burst Detection in the TeV Band

A gamma-ray burst (GRB) jet running into an external medium is expected to generate luminous GeV–TeV emission lasting from minutes to several hours. The high-energy emission results from inverse Compton upscattering of prompt and afterglow photons by shock-heated thermal plasma. At its peak the high-energy radiation carries a significant fraction of the power dissipated at the forward shock. We discuss in detail the expected TeV luminosity, using a robust “minimal” emission model. Then, using the statistical properties of the GRB population (luminosity function, redshift distribution, afterglow energy), we simulate the expected detection rates of GRBs by current and upcoming atmospheric Cherenkov instruments. We find that GRBs exploding into a low-density interstellar medium must produce TeV emission that would have already been detected by the currently operating Cherenkov telescopes. The absence of detections is consistent with explosions into a dense wind of the GRB progenitor. If, as suggested by the recent analysis of Fermi LAT data, the typical environment of long GRBs is a Wolf–Rayet progenitor wind with the density parameter A∼10{sup 11} g cm{sup −1}, then 10%–20% of the bursts that trigger the space-borne detectors should also be detectable by the upcoming Cherenkov Telescope Array (CTA) under favorable observing conditions. Since absorption by the extragalactic background light limits the detectability above 0.1 TeV for all but the most nearby bursts (z≲1), the reduced energy threshold of CTA is the key improvement over current instruments, which should increase the number of detectable bursts by at least a factor of 3 compared with currently operating facilities.

79 ASTRONOMY AND ASTROPHYSICS↗