Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Control of molten salt corrosion of fusion structural materials by metallic beryllium

A series of tests have been performed between 2001 and 2006 at the Safety and Tritium Applied Research facility of the Idaho National Laboratory to demonstrate chemical compatibility between the molten salt flibe (2LiF+BeF2 in moles) and fusion structural materials once suitable fluoride potential control methods are established. The tests adopted metallic beryllium contact as main fluoride potential control, and the results have been published in recent years. A further step was to expose two specimens of low activation ferritic/martensitic steel 9Cr-2W to static corrosion tests that include an active corrosion agent (hydrofluoric gas) in controlled conditions at 530 C, and the results of the tests are presented in this paper. The results confirmed the expected correlation of the HF recovery with the concentration of metallic impurities dissolved in the salt because of specimen corrosion. The metals concentration dropped to level close to the detectable limit when the beryllium rod was inserted and increased once the content of excess beryllium in the system had been consumed by HF reduction and specimens corrosion progressed. Metallographic analysis of the samples after 500 hours exposure in reactive conditions showed evidence of the formation of unstable chromium oxide layers on the specimens surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LIBS measurement of trace tantalum and rhenium in tungsten for in-situ diagnostic of nuclear transmutation

Calibration-free laser-induced breakdown spectroscopy (CF-LIBS) was applied to tungsten (W)- tantalum (Ta) alloy and W-rhenium (Re) alloy. In the W-Ta alloy measurement, an apparent Ta I line at 648.5 nm was found to be isolated from W I lines and used for the concentration determination. Accurate concentration measurements were achieved for a W - 2 at.% Ta specimen at the ambient gas pressure between 0.1 and 10 Torr of He, Ne and Ar gas. Within these ambient gas species, the highest line intensities were obtained by Ar gas. In the W-Re alloy measurement, the detection limit of trace Re in W-Re was investigated. CF-LIBS results agree well with the nominal concentration of Re down to W-0.5 at.% Re specimen which is better than the measurement accuracy of EDX (energy-dispersive X-ray micro-analysis). Further improvements are required in order to measure 0.2 at.% Re in W expected at ITER.

36 MATERIALS SCIENCE↗

Tomographic analysis of dilute impurities in semiconductor nanostructures

We describe the application of pulsed-laser atom probe (PLAP) tomography to the analysis of dopants and unintentional impurities in Si and Ge nanowires grown by the vapor-liquid-solid mechanism. PLAP tomography was used to determine the concentration of phosphorous in Ge nanowires and B in Si nanowires, enabling comparisons of the atomic concentrations of the reactants with those of the reaction products. Oxygen impurities were also detected, but the contribution from background gas adsorption was not ruled out. Gold catalyst impurities were not detected, and an upper bound of 5 ppm was established. Intrinsic and extrinsic origins of the detection limits of dopants and other impurities are described in detail. A tapered nanowire geometry was found to improve the mass resolution and signal-to-noise ratio by increasing the tip cooling rate. Simulations of nanowire cooling under laser pulsing were used to validate this improved approach to PLAP analysis of nanowires. - Graphical abstract: Scanning electron micrograph of a P-doped Ge nanowire including the Au catalyst tip (top). The corresponding 3D reconstruction (middle) and mass spectrum (bottom) of the boxed region produced via atom probe tomography. From the 3D reconstruction and mass spectrum, the concentration and distribution of dopants can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of graphene/polyaniline composite multilayer films by electrostatic layer-by-layer assembly

A novel graphene/polyaniline composite multilayer film was fabricated by electrostatic interactions induced layer-by-layer self-assembly technique, using water dispersible and negatively charged chemically converted graphene (CCG) and positively charged polyaniline (PANI) as building blocks. CCG was achieved through partly reduced graphene oxide, which remained carboxyl group on its surface. The remaining carboxyl groups not only retain the dispersibility of CCG, but also allow the growth of the multilayer films via electrostatic interactions between graphene and PANI. The structure and morphology of the obtained CCG/PANI multilayer film are characterized by attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, Ultraviolet–visible absorption spectrum (UV–vis), scanning electron microscopy (SEM), Raman spectroscopy and X-Ray Diffraction (XRD). The electrochemical properties of the resulting film are studied using cyclic voltammetry (CV), which showed that the resulting CCG/PANI multilayer film kept electroactivity in neutral solution and showed outstanding cyclic stability up to 100 cycles. Furthermore, the composite film exhibited good electrocatalytic ability toward ascorbic acid (AA) with a linear response from 1×10{sup −4} to 1.2×10{sup −3} M with the detect limit of 5×10{sup −6} M. This study provides a facile and effective strategy to fabricate graphene/PANI nanocomposite film with good electrochemical property, which may find potential applications in electronic devices such as electrochemical sensor. - Graphical abstract: A novel graphene/polyaniline (CCG/PANI) film was prepared by layer-by-layer assembly. - Highlights: • A novel graphene/polyaniline (CCG/PANI) film was prepared by layer-by-layer assembly. • The water dispersible and negatively charged graphene (CCG) was used as building block. • CCG was achieved through partly reduced graphene oxide with carboxyl group on its surface. • CCG/PANI film kept electroactivity in neutral solution and showed good stability. • Good electrocatalytic ability toward ascorbic acid was also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoflakes of an aminoacid-based chiral coordination polymer: Synthesis, optical and electrochemical properties, and application in electrochemical sensing of H{sub 2}O{sub 2}

Nanoflakes of an aminoacid-based chiral coordination polymer (CP), [Cu{sub 2}(tyr){sub 2}(bipy)]{sub n}, were synthesized successfully in the presence of surfactant, as evidenced by the XRD and SEM results. UV–vis absorption spectrometry and fluorescence spectrometry were used to investigate the optical properties of the CP, which was found to be mainly attributed to the ligands, while the forming of the CP caused only slight change. On the other hand, Cu(II) ions acted as electrocatalytic active sites of the CP, as evidenced by cyclic voltammetry. The CP also showed good performance in the electrochemical sensing of H{sub 2}O{sub 2}: sensitivity of 85.6 mA mol{sup −1} L cm{sup −2}, linear range of 1.0×10{sup −5}–7.69×10{sup −3} M, detection limit of 1.0×10{sup −5} M (S/N=3), and fast response in mere 5 s. - Graphical abstract: Nanoflakes of an aminoacid-based chiral coordination polymer (CP), [Cu{sub 2}(tyr){sub 2}(bipy)]{sub n}, were synthesized successfully and showed good performance in the electrochemical sensing of H{sub 2}O{sub 2}. - Highlights: • Synthesis of nanoflakes of an aminoacid-based chiral CP. • Optical and electrochemical properties resulting respectively from ligands and Cu{sup II}. • Good performance in enzyme-free electrochemical sensing of H{sub 2}O{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trimethylamine sensing properties of graphene quantum Dots/α-Fe{sub 2}O{sub 3} composites

Graphene quantum dots (GQDs) were prepared by pyrolysis of citric acid. The sizes of the as-prepared GQDs were in the range of 2–4 nm. The GQDs/α-Fe{sub 2}O{sub 3} composites were prepared by loading GQDs with α-Fe{sub 2}O{sub 3} via a one-step facile hydrothermal method. The GQDs/α-Fe{sub 2}O{sub 3} composites were characterized by XRD, TGA, FTIR, Raman, SEM and TEM, respectively. The sensor devices were fabricated using the GQDs/α-Fe{sub 2}O{sub 3} composites as sensing materials. The effect of the amount of GQDs in the composites on the gas-sensing responses of the materials and the gas-sensing selectivity was investigated. The experimental results revealed that the sensor based on GQDs/α-Fe{sub 2}O{sub 3} (S-15) composite exhibited high sensitivity and good selectivity to TMA vapor. The responses of the sensor based on GQDs/α-Fe{sub 2}O{sub 3} (S-15) composite to 1000 ppm and 0.01 ppm TMA vapor attained 1033.0 and 1.9 at 270 °C, respectively. The response time and recovery time for 0.01 ppm TMA vapor were only 6 s and 4 s, respectively. - Graphical abstract: (1) The sizes of the GQDs are in the range of 2–5 nm; (2) The responses of the sensor based on GQDs/α-Fe{sub 2}O{sub 3} (S-15) composite to 0.01, 0.1, 1, 10, 100 and 1000 ppm TMA vapor at 270 °C are 1.9, 2.9, 5.5, 15.4, 293.0 and 1033.0, respectively, and the detection limit can reach 0.01 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional (3D) visualization of reflow porosity and modeling of deformation in Pb-free solder joints

The volume, size, and dispersion of porosity in solder joints are known to affect mechanical performance and reliability. Most of the techniques used to characterize the three-dimensional (3D) nature of these defects are destructive. With the enhancements in high resolution computed tomography (CT), the detection limits of intrinsic microstructures have been significantly improved. Furthermore, the 3D microstructure of the material can be used in finite element models to understand their effect on microscopic deformation. In this paper we describe a technique utilizing high resolution (< 1 {mu}m) X-ray tomography for the three-dimensional (3D) visualization of pores in Sn-3.9Ag-0.7Cu/Cu joints. The characteristics of reflow porosity, including volume fraction and distribution, were investigated for two reflow profiles. The size and distribution of porosity size were visualized in 3D for four different solder joints. In addition, the 3D virtual microstructure was incorporated into a finite element model to quantify the effect of voids on the lap shear behavior of a solder joint. The presence, size, and location of voids significantly increased the severity of strain localization at the solder/copper interface.

36 MATERIALS SCIENCE↗

The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures

In material science microfocus X-ray computed tomography (micro-CT) is one of the most popular non-destructive techniques to visualise and quantify the internal structure of materials in 3D. Despite constant system improvements, state-of-the-art micro-CT images can still hold several artefacts typical for X-ray CT imaging that hinder further image-based processing, structural and quantitative analysis. For example spatial resolution is crucial for an appropriate characterisation as the voxel size essentially influences the partial volume effect. However, defining the adequate image resolution is not a trivial aspect and understanding the correlation between scan parameters like voxel size and the structural properties is crucial for comprehensive material characterisation using micro-CT. Therefore, the objective of this study was to evaluate the influence of the spatial image resolution on the micro-CT based morphological analysis of three-dimensional (3D) open porous structures with a high surface complexity. In particular the correlation between the local surface properties and the accuracy of the micro-CT-based macro-morphology of 3D open porous Ti6Al4V structures produced by selective laser melting (SLM) was targeted and revealed for rough surfaces a strong dependence of the resulting structure characteristics on the scan resolution. Reducing the surface complexity by chemical etching decreased the sensitivity of the overall morphological analysis to the spatial image resolution and increased the detection limit. This study showed that scan settings and image processing parameters need to be customized to the material properties, morphological parameters under investigation and the desired final characteristics (in relation to the intended functional use). Customization of the scan resolution can increase the reliability of the micro-CT based analysis and at the same time reduce its operating costs. - Highlights: • We examine influence of the image resolution on μCT-based morphological analysis. • Surface properties influence accuracy of μCT-based morphology of porous structures. • Total porosity was the least sensitive to surface complexity and scan voxel size. • The beam thickness analysis was overestimated by the surface roughness. • Voxel size customization can significantly reduce a cost of the μCT-based analysis.

36 MATERIALS SCIENCE↗

A novel nanostructured composite formed by interaction of copper octa(3-aminopropyl)octasilsesquioxane with azide ligands: Preparation, characterization and a voltammetric application

This study presents the preparation, characterization and application of copper octa(3-aminopropyl)octasilsesquioxane following its subsequent reaction with azide ions (ASCA). The precursor (AC) and the novel compound (ASCA) were characterized by Fourier transform infrared spectra (FTIR), nuclear magnetic resonance (NMR), electron paramagnetic resonance (EPR), scanning electronic microscopy (SEM), X-ray diffraction (XRD), Thermogravimetric analyses and voltammetric technique. The cyclic voltammogram of the modified graphite paste electrode with ASCA (GPE-ASCA), showed one redox couple with formal potential (E{sub 1/2}{sup ox}) = 0.30 V and an irreversible process at 1.1 V (vs. Ag/AgCl; NaCl 1.0 M; v=20mVs{sup -1}). The material is very sensitive to nitrite concentrations. The modified graphite paste electrode (GPE-ASCA) gives a linear range from 1.0 x 10{sup -4} to 4.0 x 10{sup -3} mol L{sup -1} for the determination of nitrite, with a detection limit of 2.1 x 10{sup -4} mol L{sup -1} and the amperometric sensitivity of 8.04 mA/mol L{sup -1}.

36 MATERIALS SCIENCE↗

Low loss Sr{sub 1-x}Ca{sub x}La{sub 4}Ti{sub 5}O{sub 17} microwave dielectric ceramics

Highlights: {yields} New single phase highly dense (95%) microwave dielectric Sr{sub 1-x}Ca{sub x}La{sub 4}Ti{sub 5}O{sub 17} (0 {<=} x {<=} 1) ceramics were designed and processed. {yields} Theoretical density and molar volume decreased due to the substitution of small Ca{sup 2+} for large Sr{sup 2+}. {yields} As required for microwave dielectric applications, optimum properties (i.e. {epsilon}{sub r} {approx} 53.7, Qf{sub o} {approx} 11,532 GHz and {tau}{sub f} {approx} -1.4 ppm/{sup o}C) were achieved for Sr{sub 0.4}Ca{sub 0.6}La{sub 4}Ti{sub 5}O{sub 17} (x = 0.6). -- Abstract: Microwave dielectric ceramics in the Sr{sub 1-x}Ca{sub x}La{sub 4}Ti{sub 5}O{sub 17} (0 {<=} x {<=} 1) composition series were prepared through a solid state mixed oxide route. All the compositions formed single phase ceramics within the detection limit of in-house X-ray diffraction when sintered in the temperature range 1450-1580 {sup o}C. Theoretical density and molar volume decreased due to the substitution of Ca{sup 2+} for Sr{sup 2+} which was associated with a decrease in the dielectric constant ({epsilon}{sub r}) and temperature coefficient of resonant frequency ({tau}{sub f}) but an increase in quality factor, Qf{sub o}. Optimum properties were achieved for Sr{sub 0.4}Ca{sub 0.6}La{sub 4}Ti{sub 5}O{sub 17} which exhibited, {epsilon}{sub r} {approx} 53.7, Qf{sub o} {approx} 11,532 GHz and {tau}{sub f} {approx} -1.4 ppm/{sup o}C.

36 MATERIALS SCIENCE↗

Hierarchical hollow microsphere and flower-like indium oxide: Controllable synthesis and application as H{sub 2}S cataluminescence sensing materials

Graphical abstract: Hierarchical hollow microsphere and flower-like In{sub 2}O{sub 3} were controllable fabricated through a novel and simple hydrothermal process, and the former showed superior cataluminescence sensing performance to H{sub 2}S. Highlights: ► In{sub 2}O{sub 3} hierarchical hollow sphere were prepared via a hydrothermal route. ► The growth process of In{sub 2}O{sub 3} hierarchical hollow sphere has been investigated. ► The sensor based on prepared In{sub 2}O{sub 3} shows good sensing performance to H{sub 2}S. -- Abstract: In the present work, In{sub 2}O{sub 3} hierarchical hollow microsphere and flower-like microstructure were achieved controllably by a hydrothermal process in the sodium dodecyl sulfate (SDS)-N,N-dimethyl-formamide (DMF) system. XRD, SEM, HRTEM and N{sub 2} adsorption measurements were used to characterize the as-prepared indium oxide materials and the possible mechanism for the microstructures formation was briefly discussed. The cataluminescence gas sensor based on the as-prepared In{sub 2}O{sub 3} was utilized to detect H{sub 2}S concentrations in flowing air. Comparative gas sensing results revealed that the sensor based on hierarchical hollow microsphere exhibited much higher sensing sensitivity in detecting H{sub 2}S gas than the sensor based on flower-like microstructure. The present gas sensor had a fast response time of 5 s and a recovery time of less than 25 s, furthermore, the cataluminescence intensity vs. H{sub 2}S concentration was linear in range of 2–20 μg mL{sup −1} with a detection limit of 0.5 μg mL{sup −1}. The present highly sensitive, fast-responding, and low-cost In{sub 2}O{sub 3}-based gas sensor for H{sub 2}S would have many practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile synthesis of Cu/Cu{sub x}O nanoarchitectures with adjustable phase composition for effective NO{sub x} gas sensor at room temperature

Graphical abstract: The Cu/Cu{sub x}O nanoarchitectures with 30–70 nm hollow nanospheres reduced by 3 mmol NaBH{sub 4} exhibits excellent gas-sensing property to low-concentration NO{sub x} gas at room temperature. - Highlights: • The Cu/Cu{sub x}O nanoarchitectures with hollow nanospheres are successfully synthesized. • The method is used for preparing the with Cu/Cu{sub x}O adjustable phase composition. • The C3 sample exhibites excellent gas-sensing propertie to NO{sub x} at room temperation. • The Cu/Cu{sub x}O nanoarchitectures have significant for application of gas sensor. - Abstract: The Cu/Cu{sub x}O nanoarchitectures with 30–70 nm hollow nanospheres are successfully synthesized by a facile wet chemical method. The synthesized products have been studied by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and thermo gravimetric-differential scanning calorimetry (TG-DSC) analysis. The Cu/Cu{sub x}O sensors based on the nanoarchitectures are used to detect the NO{sub x} at room temperature. The results demonstrate that the obtained Cu/Cu{sub x}O nanoarchitectures reduced by 3 mmol NaBH{sub 4} exhibits excellent gas-sensing properties: low detection limit of 0.97 ppm, relatively high sensitivity, short response time, broad linear range and high selectivity. The reasons for gas-sensing activity enhancement on Cu/Cu{sub x}O nanoarchitectures are discussed. The Cu/Cu{sub x}O nanocrystalline with the hierarchical pores structure and tunable compositions have significant for application of gas sensor.

36 MATERIALS SCIENCE↗

Sodium doping effect on physicochemical properties of K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) for the determination of mercury(II): Application in seawater samples

Highlights: • The apatite, K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1), was synthesized using reaction solid. • The obtained apatite was used to determine mercury in seawater samples from Morocco. • The effect of doping sodium into apatite on physic-chemical parameters was studied. • The influence of the electrochemical variables was investigated to determine mercury. - Abstract: A new chemically modified electrode was synthesized for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV). The electrode was modified by lacunar apatite K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) synthesized using solid reaction. These powders were crystallized in the hexagonal system, space group P6{sub 3}/m. The effect of sodium content on structural, thermodynamic and electrochemical properties of prepared apatite has been studied. Therefore, the best results was obtained using NaCaPb{sub 3}(PO{sub 4}){sub 3} (x = 1) as modifier of carbon paste electrode for the electrochemical detection of mercury(II). The later ions were preconcentrated on the surface of the modified electrode and oxidized at 0.06 V vs. Ag/AgCl. The electroanalytical procedure comprises of two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse voltammetry. The different parameters that govern the two steps were optimized. A linear response was obtained in the concentration range from 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} to 2.0 mol L{sup −1} × 10{sup −7} mol L{sup −1} Hg(II) after activation of the electrode surface under the optimized conditions. The standard deviation was evaluated in a high and low concentration of mercury(II). The values ​​obtained for seven consecutive measurements were 1.24% and 5.07% of 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} and 5.0 mol L{sup −1} × 10{sup −6} mol L{sup −1} mercury(II) solutions respectively. The detection limit and quantification limit for mercury(II), calculated from nine times standard deviation of blank/slope of the calibration graph, were 1.086 mol L{sup −1} × 10{sup −8} mol L{sup −1} and 3.62 mol L{sup −1} × 10{sup −8} mol L{sup −1}, respectively. The proposed chemically modified electrode was applied to determine mercury(II) in seawater samples.

36 MATERIALS SCIENCE↗

Infrared light-assisted preparation of Ag nanoparticles-reduced graphene oxide nanocomposites for non-enzymatic H{sub 2}O{sub 2} sensing

Graphical abstract: An infrared light irradiation method has been developed for preparation of AgNPs/rGO nanocomposites for electrochemical detection of H{sub 2}O{sub 2}. - Highlights: • AgNPs/rGO nanocomposites have been prepared by photochemical method. • AgNPs/rGO nanocomposites exhibit good sensing performances for detection of H{sub 2}O{sub 2}. • The present work provides a simple and green method for preparation of rGO-based materials. - Abstract: A green method has been developed for preparation of Ag nanoparticles/reduced graphene oxide (AgNPs/rGO) nanocomposites by infrared light irradiation. The characterizations indicate the successful preparation of AgNPs/rGO nanocomposites. Most importantly, AgNPs/rGO nanocomposites exhibit excellent electrocatalytic activity for reduction of H{sub 2}O{sub 2}, leading to a high-performance non-enzymatic H{sub 2}O{sub 2} sensor with linear detection range and detection limit about 0.1 mM to 140 mM (r = 0.9896) and 3.0 μM, respectively.

36 MATERIALS SCIENCE↗

Immobilization of ruthenium phthalocyanine on silica-coated multi-wall partially oriented carbon nanotubes: Electrochemical detection of fenitrothion pesticide

Highlights: • Hybrid material, SiO{sub 2}/MWCNTs containing ruthenium phthalocyanine (RuPc) synthesized in situ. • Silica containing multi-walled carbon nanotube partially oriented. • Determination of pesticide fenitrothion in orange juice. - Abstract: This paper reports on the determination of the pesticide fenitrothion using a glassy carbon electrode modified with silica-coated, multi-walled, partially oriented carbon nanotubes, SiO{sub 2}/MWCNTs, containing ruthenium phthalocyanine (RuPc) synthesized in situ. The hybrid SiO{sub 2}/MWCNTs/RuPc material was characterized by UV–vis absorption spectroscopy, X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM) and differential pulse voltammetry. The modified electrode showed well-defined peaks in the presence of fenitrothion in acetate buffer, pH 4.5, with a sensitivity of 0.0822 μA μM{sup −1} mm{sup −2} and a detection limit of 0.45 ppm. Notably, the modified SiO{sub 2}/MWCNTs/RuPc electrodes with did not suffer from significant influences in the presence of other organophosphorus pesticides during the determination of the fenitrothion pesticide. Moreover, this modified electrode showed excellent performance in the determination of fenitrothion in orange juice.

36 MATERIALS SCIENCE↗

Responsive hybrid inorganic-organic system derived from lanthanide luminescence

Highlights: • A novel covalent hybrid material was used to detect hemoglobin. • All the recognition experiments were performed in buffer solution. • Porous nano-structures was extensively studied for the recognition. - Abstract: Terbium ions were incorporated into new organic-inorganic matrices to achieve intense green emissions. Hemoglobin (HB) interactions lead to dramatic changes in the luminescence emission intensities. Infrared spectra, morphological studies and photoluminescence give information for the speciation and process of hemoglobin additions. The porous material has a large specific surface area of 351 cm{sup 2}/g and the detection limit for HB (0.7 μM) was much lower than its physical doped material (8 μM). This promising hybrid material will lead to the design of versatile optical probes that are efficiently responding to the external targets.

36 MATERIALS SCIENCE↗

Irradiation route to aqueous synthesis of highly luminescent ZnSe quantum dots and its function as a copper ion fluorescence sensor

Highlights: • Radiation chemical technique can provide a useful route for synthesis of ZnSe QDs. • Chelating nature of ethylene diamine is exploited for capping nanoparticles. • ZnSe QDs can be a suitable sensitive alternative to toxic cadmium-based system. • Cu(II) ion is probed by QDs in the presence of other physiologically relevant ions. - Abstract: Size-controlled synthesis of stable ZnSe QDs with narrow distribution in aqueous environment through conventional soft chemical method still poses a challenge. The proposed radiation assisted strategy demonstrates aqueous synthesis of stable, monodisperse and luminescent ZnSe QDs capped with chelating ethylene diamine under ambient conditions and at room temperature. Radiation chemical method facilitates in slow and in-situ release of selenium ion from sodium selenosulfate. The concentrations of precursors, such as zinc salt, selenium source, ethylene diamine and absorbed radiation (7–90 kGy) dose were optimized for obtaining good quality particles. Selective quenching of luminescence of as-synthesized quantum dots (QDs) by Cu{sup 2+} ions vis-à-vis other physiologically important cations provide evidence for use of ZnSe quantum dots as alternative to toxic Cd-based quantum dots to probe Cu{sup 2+} ions. The linear relation of ratio of loss in emission intensity as a function of concentration of Cu(II) indicates detection limit in nano-molar range.

36 MATERIALS SCIENCE↗