Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Image Correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

An efficient instance segmentation approach for studying fission gas bubbles in irradiated metallic nuclear fuel

Abstract Gaseous fission products from nuclear fission reactions tend to form fission gas bubbles of various shapes and sizes inside nuclear fuel. The behavior of fission gas bubbles dictates nuclear fuel performances, such as fission gas release, grain growth, swelling, and fuel cladding mechanical interaction. Although mechanical understanding of the overall evolution behavior of fission gas bubbles is well known, lacking the quantitative data and high-level correlation between burnup/temperature and microstructure evolution blocks the development of predictive models and reduces the possibility of accelerating the qualification for new fuel forms. Historical characterization of fission gas bubbles in irradiated nuclear fuel relied on a simple threshold method working on low-resolution optical microscopy images. Advanced characterization of fission gas bubbles using scanning electron microscopic images reveals unprecedented details and extensive morphological data, which strains the effectiveness of conventional methods. This paper proposes a hybrid framework, based on digital image processing and deep learning models, to efficiently detect and classify fission gas bubbles from scanning electron microscopic images. The developed bubble annotation tool used a multitask deep learning network that integrates U-Net and ResNet to accomplish instance-level bubble segmentation. With limited annotated data, the model achieves a recall ratio of more than 90%, a leap forward compared to the threshold method. The model has the capability to identify fission gas bubbles with and without lanthanides to better understand the movement of lanthanide fission products and fuel cladding chemical interaction. Lastly, the deep learning model is versatile and applicable to the micro-structure segmentation of similar materials.

36 MATERIALS SCIENCE↗

SU-E-J-22: A Feasibility Study On KV-Based Whole Breast Radiation Patient Setup

Purpose: In room kilovoltage x-ray (kV) imaging provides higher contrast than Megavoltage (MV) imaging with faster acquisition time compared with on-board cone-beam computed tomography (CBCT), thus improving patient setup accuracy and efficiency. In this study we evaluated the clinical feasibility of utilizing kV imaging for whole breast radiation patient setup. Methods: For six breast cancer patients with whole breast treatment plans using two opposed tangential fields, MV-based patient setup was conducted by aligning patient markers with in room lasers and MV portal images. Beam-eye viewed kV images were acquired using Varian OBI system after the set up process. In house software was developed to transfer MLC blocks information overlaying onto kV images to demonstrate the field shape for verification. KV-based patient digital shift was derived by performing rigid registration between kV image and the digitally reconstructed radiography (DRR) to align the bony structure. This digital shift between kV-based and MV-based setup was defined as setup deviation. Results: Six sets of kV images were acquired for breast patients. The mean setup deviation was 2.3mm, 2.2mm and 1.8mm for anterior-posterior, superior-inferior and left-right direction respectively. The average setup deviation magnitude was 4.3±1.7mm for six patients. Patient with large breast had a larger setup deviation (4.4–6.2mm). There was no strong correlation between MV-based shift and setup deviation. Conclusion: A preliminary clinical workflow for kV-based whole breast radiation setup was established and tested. We observed setup deviation of the magnitude below than 5mm. With the benefit of providing higher contrast and MLC block overlaid on the images for treatment field verification, it is feasible to use kV imaging for breast patient setup.

60 APPLIED LIFE SCIENCES↗

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗

A study of Minnesota land and water resources using remote sensing

The author has identified the following significant results. Both LANDSAT imagery and digital data were studied for usefulness in surveying water conditions of Minnesota lakes. Initial consideration was given to analysis of LANDSAT image densities because of the low technologic and cost requirements. The techniques employed, however, yield inconsistent and unreliable results. A set of criteria are given for using LANDSAT data in identification of three categories of particulate contaminants in Lake Superior. A linear transformation giving the relationship between the residual LANDSAT intensities and concentrations of three contaminants was obtained from correlation of remote sensing data with insitu measurements. LANDSAT imagery was found useful in placing peat bogs and fens in their respective geologic settings. Artificial disturbances and drainageways in peatlands could be recognized and classified.

Shepherd, W. G.↗

Non-subjective cataract analysis and its application in space radiation risk assessment

Experimental animal studies and human observations suggest that the question is not whether or not prolonged space missions will cause cataracts to appear prematurely in the astronauts, but when and to what degree. Historically the major impediment to radiation cataract follow-up has been the necessarily subjective nature of assessing the degree of lens transparency. This has spurred the development of instruments which produce video images amenable to digital analysis. One such system, the Zeiss Scheimpflug slit lamp measuring system (SLC), was incorporated into our ongoing studies of radiation cataractogenesis. It was found that the Zeiss SLC measuring system has high resolution and permits the acquisition of reproducible images of the anterior segment of the eye. Our results, based on about 650 images of the rats lens, and followed over a period of 91 weeks of radiation cataract development, showed that the Integrated Optical Density (IOD) of the lens correlated well with conventional assessment with the added advantages of objectivity, permanent and transportable records and linearity as cataracts become more severe. This continuous data acquisition, commencing with cataract onset, can proceed through more advanced stages. The SLC exhibits much greater sensitivity reflected in a continuously progressive severity despite the artifactual plateaus in staging which occur using conventional scoring methods. Systems such as the Zeiss SLC should be used to monitor astronauts frequent visits to low earth orbit to obtain a longitudinal data-base on the influence of this activity on the lens.

Wu, B.↗

Digital halftoning methods for selectively partitioning error into achromatic and chromatic channels

A method is described for reducing the visibility of artifacts arising in the display of quantized color images on CRT displays. The method is based on the differential spatial sensitivity of the human visual system to chromatic and achromatic modulations. Because the visual system has the highest spatial and temporal acuity for the luminance component of an image, a technique which will reduce luminance artifacts at the expense of introducing high-frequency chromatic errors is sought. A method based on controlling the correlations between the quantization errors in the individual phosphor images is explored. The luminance component is greatest when the phosphor errors are positively correlated, and is minimized when the phosphor errors are negatively correlated. The greatest effect of the correlation is obtained when the intensity quantization step sizes of the individual phosphors have equal luminances. For the ordered dither algorithm, a version of the method can be implemented by simply inverting the matrix of thresholds for one of the color components.

Mulligan, Jeffrey B.↗

The evolution of the SEASAT imaging radar

The paper describes the design parameters and development of a synthetic aperture radar for use on the SEASAT spacecraft. This imaging radar is designed to operate at altitudes of 800 km with an orbital inclination of 108 deg, a nominal resolution of 25 m, and a swath width of 100 km. The design evolved from planetary imaging radar studies conducted over many years where an L-band imaging radar was developed and tested on aircraft flights as a prototype system to map the surface of Venus. A solid-state transmitter is used where the pulse repetition frequency is a function of altitude and will be about 2kHz for a 12-m long antenna. The receiver consists of the receiver protector, input filters, the gain control, and the RF amplifier. The ground station uses the standard NASA receiver with a 10-m antenna. The correlator, either optical or digital, must be able to compensate for the pitch and yaw variations of the spacecraft as well as the inherent effective yaw caused by the rotation of the earth, and extract the range curvature and range walk effects.

Brown, W. E., Jr.↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

Pulse-echo ultrasonic imaging method for eliminating sample thickness variation effects

A pulse-echo, immersion method for ultrasonic evaluation of a material is discussed. It accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer, automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjusments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.

Roth, Don J.↗

Pulse-Echo Ultrasonic Imaging Method for Eliminating Sample Thickness Variation Effects

A pulse-echo, immersion method for ultrasonic evaluation of a material which accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer and automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjustments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.

Roth, Don J.↗

Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement potential of laser speckle velocimetry

Laser speckle velocimetry, the measurement of fluid velocity by measuring the translation of speckle pattern or individual particles that are moving with the fluid, is described. The measurement is accomplished by illuminating the fluid with consecutive pulses of Laser Light and recording the images of the particles or the speckles on a double exposed photographic plate. The plate contains flow information throughout the image plane so that a single double exposure may provide data at hundreds or thousands of points in the illuminated region of the fluid. Conventional interrogation of the specklegram involves illuminating the plate to form Young's fringes, whose spacing is inversely proportional to the speckle separation. Subsequently the fringes are digitized and analyzed in a computer to determine their frequency and orientation, yielding the velocity magnitude and orientation. The Young's fringe technique is equivalent to performing a 2-D spatial correlation of the double exposed specklegram intensity pattern, and this observation suggests that correlation should be considered as an alternative processing method. The principle of the correlation technique is examined.

Adrian, R. J.↗

Image processing via VLSI: A concept paper

Implementing specific image processing algorithms via very large scale integrated systems offers a potent solution to the problem of handling high data rates. Two algorithms stand out as being particularly critical -- geometric map transformation and filtering or correlation. These two functions form the basis for data calibration, registration and mosaicking. VLSI presents itself as an inexpensive ancillary function to be added to almost any general purpose computer and if the geometry and filter algorithms are implemented in VLSI, the processing rate bottleneck would be significantly relieved. A set of image processing functions that limit present systems to deal with future throughput needs, translates these functions to algorithms, implements via VLSI technology and interfaces the hardware to a general purpose digital computer is developed.

Nathan, R.↗

Application of DPIV to Enhanced Mixing Heated Nozzle Flows

Digital Particle Imaging Velocimetry (DPIV) is a planar velocity measurement technique that continues to be applied to new and challenging engineering research facilities while significantly reducing facility test time. DPIV was used in the GRC Nozzle Acoustic Test Rig (NATR) to characterize the high temperature (560 C), high speed (is greater than 500 m/s) flow field properties of mixing enhanced jet engine nozzles. The instantaneous velocity maps obtained using DPIV were used to determine mean velocity, rms velocity and two-point correlation statistics to verify the true turbulence characteristics of the flow. These measurements will ultimately be used to properly validate aeroacoustic model predictions by verifying CFD input to these models. These turbulence measurements have previously not been possible in hot supersonic jets. Mapping the nozzle velocity field using point based techniques requires over 60 hours of test time, compared to less than 45 minutes using DPIV, yielding a significant reduction in testing time. A dual camera DPIV configuration was used to maximize the field of view and further minimize the testing time required to map the nozzle flow. The DPIV system field of view covered 127 by 267 mm. Data were acquired at 19 axial stations providing coverage of the flow from the nozzle exit to 2.37 in downstream. At each measurement station, 400 image frame pairs were acquired from each camera. The DPIV measurements of the mixing enhanced nozzle designs illustrate the changes in the flow field resulting in the reduced noise signature.

Wernet, Mark P.↗

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEW CANDIDATE ERUPTIVE YOUNG STARS IN LYNDS 1340

We report on the discovery of three candidate eruptive young stars, found during our comprehensive multi-wavelength study of the young stellar population of the dark cloud L1340. These stars are as follows. (1) IRAS 02224+7227 (2MASS 02270555+7241167, HH 487S) exhibited FUor-like spectrum in our low-resolution optical spectra. The available photometric data restrict its luminosity to 23 L {sub ☉} < L {sub bol} < 59 L {sub ☉}. (2) 2MASS 02263797+7304575, identified as a classical T Tauri star during our Hα survey, exhibited an EXor-type brightening in 2005 November at the time of the Sloan Digital Sky Survey observations of the region. (3) 2MASS 02325605+7246055, a low-mass embedded young star, associated with a fan-shaped infrared nebula, underwent an outburst between the DSS 1 and DSS 2 surveys, leading to the appearance of a faint optical nebula. Our [S II] and Hα images, as well as the Spitzer Infrared Array Camera 4.5 μm images, revealed Herbig-Haro objects associated with this star. Our results suggest that amplitudes and timescales of outbursts do not necessarily correlate with the evolutionary stage of the stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Multibeam single frequency synthetic aperture radar processor for imaging separate range swaths

A single-frequency multibeam synthetic aperture radar for large swath imaging is disclosed. Each beam illuminates a separate ""footprint'' (i.e., range and azimuth interval). The distinct azimuth intervals for the separate beams produce a distinct Doppler frequency spectrum for each beam. After range correlation of raw data, an optical processor develops image data for the different beams by spatially separating the beams to place each beam of different Doppler frequency spectrum in a different location in the frequency plane as well as the imaging plane of the optical processor. Selection of a beam for imaging may be made in the frequency plane by adjusting the position of an aperture, or in the image plane by adjusting the position of a slit. The raw data may also be processed in digital form in an analogous manner.

Jain, A.↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗