Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Distributionally Robust Partially Observable Markov Decision Process with Moment-Based Ambiguity

In this paper, we consider a distributionally robust partially observable Markov decision process (DR-POMDP), where the distribution of the transition-observation probabilities is unknown at the beginning of each decision period, but their realizations can be inferred using side information at the end of each period after an action being taken. We build an ambiguity set of the joint distribution using bounded moments via conic constraints and seek an optimal policy to maximize the worst-case (minimum) reward for any distribution in the set. We show that the value function of DR-POMDP is piecewise linear convex with respect to the belief state and propose a heuristic search value iteration method for obtaining lower and upper bounds of the value function. We conduct numerical studies and demonstrate the computational performance of our approach via testing instances of a dynamic epidemic control problem. Our results show that DR-POMDP can produce more robust policies under misspecified distributions of transition-observation probabilities as compared to POMDP but has less costly solutions than robust POMDP. The DR-POMDP policies are also insensitive to varying parameter in the ambiguity set and to noise added to the true transition-observation probability values obtained at the end of each decision period.

97 MATHEMATICS AND COMPUTING↗

Rare Earth Element (REE) and Critical Mineral Fractions of Central Appalachian Coal-Related Strata Determined by 7-Step Sequential Extraction

Rare earth elements (REEs) and critical minerals (CMs) are used in many modern industries, including the automotive sector, generation and storage, clean energy, and defense. The demand for REEs is increasing, and the REE supply chain is unpredictable. The US has driven to assess non-conventional sources of REE (such as coal underclay) to identify domestic resources to stabilize this uncertainty in supply. Knowledge of the minerology, distribution, and modes of occurrence of REEs is integral to the assessment of non-conventional sources. Additionally, extraction techniques can be optimized and targeted when REE distribution in different solid fractions from source material is understood. In this study, four bituminous coal-related samples associated with the Lower and Middle Kittanning coal seams in the Appalachian Basin (US) underwent a seven-step sequential extraction procedure, primarily targeting the water-soluble, exchangeable, acid soluble, mildly reducible, moderately reducible, strongly reducible, and oxidizable fractions. The REE and other elements of interest from each extraction step were analyzed, and the percentages of element extracted from raw solids were calculated. REEs extracted from the total seven steps were reported as the extractable fraction, whereas the fractions in the residual solids were reported as the non-extractable fraction. Less than 6% of REE were extracted from three samples. Twenty-one percent of REE was extracted from the fourth sample, mainly from the steps targeting oxidizable and exchangeable phases. Co-extraction of critical metals (Co, Ni, Cu, and Zn) occurred during the oxidizable, exchangeable, acid soluble, and water-soluble steps for the four samples. In the extracted fractions, the four samples all exhibited a middle and heavy REE enrichment relative to light REE. The mobility of major cation (e.g., Ca, Fe, and P) and REE is associated with exchangeable, oxidizable, and acid soluble fractions. Non-extractable REE is likely held in refractory apatitic phases, and/or primary REE-phosphates (e.g., monazite and xenotime).

58 GEOSCIENCES↗

Data assimilation for burnup distribution of PWR with three-dimensional variational algorithm and artificial neutral network

In this paper, a data-assimilation method has been proposed and applied for the burnup distribution of PWR. The burnup distribution is significant to the safety and economy of the reactor, as it is essential for the fuel-reloading design and optimization. Due to the burnup distribution cannot be measured directly during the reactor operation, the numerical simulation is widely applied to determine the burnup distribution. However, there is a deviation between the numerical simulation and the actual core due to some unavoidable factors, such as component manufacturing deviation, uneven flow distribution and so on. These differences would induce the errors to the simulation values of power distributions and hence to the burnup distribution. To address this problem, a data-assimilation method for the burnup distribution has been proposed with the application of power-distribution measurements. In our research, the three-dimensional variational (3DVAR) algorithm was applied for burnup-distribution calibration and the artificial neutral network (ANN) was applied to establish the relation between power distribution and corresponding burnup distribution. As engineering verification, the proposed data-assimilation method has been applied to the CNP1000 PWR operated in China. The numerical results indicated that the burnup-distribution errors can be reduced notably, as the maximum value of relative errors for power distribution can be reduced from 5.35% to 3.96%. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A VSM-Based DER Dispatch MINLP for Volt-VAR Control in Unbalanced Power Distribution Systems

This paper presents an optimal dispatch algorithm to coordinate customer-owned controllable loads and smart solar inverters with utility-owned voltage regulators and capacitors to meet voltage control objectives. The optimization problem is formulated as a mixed-integer nonlinear programming (MINLP) problem. A voltage sensitivity matrix (VSM) is used to linearize the effect of control actions on the voltage at customer nodes when solving the MINLP. The VSM is recalculated at each time step to improve the computational accuracy. Both discrete switching actions of the capacitor and VRs and the continuous adjustment of real and reactive power from load and smart inverters are considered in the MINLP volt-var problem formulation. The objective function minimizes the cost of all control actions and the magnitude of voltage fluctuations from the previous time period. Constraints ensure that the voltage at each node is maintained within ANSI limits and the feeder power factor is controlled within the desired range. The algorithm is tested using an actual 3-phase unbalanced distribution feeder model. Simulation results demonstrate that the proposed algorithm is computationally feasible on real circuits and improves voltage control while minimizing operational costs.

McEntee, Catie↗

Distributed wireless sensing for fugitive methane leak detection

Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It is demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.

04 OIL SHALES AND TAR SANDS↗

Distributed wireless sensing for methane leak detection technology

Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It is demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using spatial information about recurrence risk for robust optimization of dose-painting prescription functions

Purpose: To develop a robust method for deriving dose-painting prescription functions using spatial information about the risk for disease recurrence. Methods: Spatial distributions of radiobiological model parameters are derived from distributions of recurrence risk after uniform irradiation. These model parameters are then used to derive optimal dose-painting prescription functions given a constant mean biologically effective dose. Results: An estimate for the optimal dose distribution can be derived based on spatial information about recurrence risk. Dose painting based on imaging markers that are moderately or poorly correlated with recurrence risk are predicted to potentially result in inferior disease control when compared the same mean biologically effective dose delivered uniformly. A robust optimization approach may partially mitigate this issue. Conclusions: The methods described here can be used to derive an estimate for a robust, patient-specific prescription function for use in dose painting. Two approximate scaling relationships were observed: First, the optimal choice for the maximum dose differential when using either a linear or two-compartment prescription function is proportional to R, where R is the Pearson correlation coefficient between a given imaging marker and recurrence risk after uniform irradiation. Second, the predicted maximum possible gain in tumor control probability for any robust optimization technique is nearly proportional to the square of R.

61 RADIATION PROTECTION AND DOSIMETRY↗

Coordinated distribution network control of tap changer transformers, capacitors and PV inverters

A power distribution system operates most efficiently with voltage deviations along a feeder kept to a minimum and must ensure all voltages remain within specified limits. Recently with the increased integration of photovoltaics, the variable power output has led to increased voltage fluctuations and violation of operating limits. This study proposes an optimization model based on a recently developed heuristic search method, grey wolf optimization, to coordinate the various distribution controllers. Several different case studies on IEEE 33 and 69 bus test systems modified by including tap changing transformers, capacitors and photovoltaic solar panels are performed. Simulation results are compared to two other heuristic-based optimization methods: harmony search and differential evolution. Finally, the simulation results show the effectiveness of the method and indicate the usage of reactive power outputs of PVs facilitates better voltage magnitude profile.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal placement of data concentrators for expansion of the smart grid communications network

Evolving power systems with increasing renewables penetration, along with the development of the smart grid, calls for improved communication networks to support these distributed generation sources. Automatic and optimal placement of communication resources within the advanced metering infrastructure is critical to provide a high‐performing, reliable, and resilient power system. Three network design formulations based on mixed‐integer linear and non‐linear programming approaches are proposed to minimise network congestion by optimising residual buffer capacity through the placement of data concentrators and network routeing. Results on a case study show that the proposed models improve network connectivity and robustness, and increase average residual buffer capacity. Maximising average residual capacity alone, however, results in both oversaturated and underutilised nodes, while maximising either minimum residual capacity or total reciprocal residual capacity can yield much‐improved network load allocation. Consideration of connection redundancy improves network reliability further by ensuring quality‐of‐service in the event of an outage. Analysis of multi‐period network expansion shows that the models do not deviate significantly from optimal when used progressively (within 5% deviation), and are effective for utility planners to use for smart grid expansion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of multiple-shell gas nozzles for refurbished Z.

This paper presents initial designs of multiple-shell gas puff imploding loads for the refurbished Z generator. The nozzle has three independent drivers for three independent plena. The outer and middle plena may be charged to 250psia whilst the central jet can be charged to 1000psia. 8-cm and 12-cm outer diameter nozzles have been built and tested on the bench. The unique valve design provides a very fast opening, hence the amount of stray gas outside the core nozzle flow is minimized. A similar 8-cm nozzle was characterized earlier using a fiber optic interferometer, but at lower pressures and without the central jet. Those data have been scaled to the higher pressures required for refurbished Z and used to estimate performance. The use of three independent plena allows variation of the pressure (hence mass distribution) in the nozzle flow, allowing optimization of implosion stability and the on-axis mass that most contributes to K-shell emission. Varying the outer/middle mass ratios influences the implosion time and should affect the details of the assembly on axis as well as the radiation physics. Varying the central jet pressure will have a minor effect on implosion dynamics, but a strong effect on pinch conditions and radiation physics. Optimum mass distributions for planned initial Ar shots on refurbished Z are described. Additional interferometer data including the central jet and at higher pressures will also be presented.

99 GENERAL AND MISCELLANEOUS↗

Smart distribution systems

The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs) and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs) of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. A comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD), is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Furthermore, test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs) is introduced. Future research in a smart distribution environment is proposed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The emergence of nonuniform spatiotemporal fractionation schemes within the standard BED model

Purpose: Nonuniform spatiotemporal radiotherapy fractionation schemes, i.e., delivering distinct dose distributions in different fractions can potentially improve the therapeutic ratio. This is possible if the dose distributions are designed such that similar doses are delivered to normal tissues (exploit the fractionation effect) while hypofractionating subregions of the tumor. In this paper, the authors develop methodology for treatment planning with nonuniform fractions and demonstrate this concept in the context of intensity-modulated proton therapy (IMPT). Methods: Treatment planning is performed by simultaneously optimizing (possibly distinct) IMPT dose distributions for multiple fractions. This is achieved using objective and constraint functions evaluated for the cumulative biologically equivalent dose (BED) delivered at the end of treatment. BED based treatment planning formulations lead to nonconvex optimization problems, such that local gradient based algorithms require adequate starting positions to find good local optima. To that end, the authors develop a combinatorial algorithm to initialize the pencil beam intensities. Results: The concept of nonuniform spatiotemporal fractionation schemes is demonstrated for a spinal metastasis patient treated in two fractions using stereotactic body radiation therapy. The patient is treated with posterior oblique beams with the kidneys being located in the entrance region of the beam. It is shown that a nonuniform fractionation scheme that hypofractionates the central part of the tumor allows for a skin and kidney BED reduction of approximately 10%–20%. Conclusions: Nonuniform spatiotemporal fractionation schemes represent a novel approach to exploit fractionation effects that deserves further exploration for selected disease sites.

60 APPLIED LIFE SCIENCES↗

Load Modeling with Smart Meter Data for Advanced Volt-VAR Optimization Applications

This paper demonstrates the creation of time-varying, end-use electric load models with electric meter data for use by advanced, model-based volt-VAR optimization (VVO) control schemes. VVO has been shown to reduce energy consumption and peak demand in the electric distribution system. Modern VVO systems use power flow models to make control decisions. In order to make optimal decisions, these models must contain accurate load models. To improve these load models, this work uses active power, reactive power, and voltage magnitude measurements from advanced metering infrastructure (AMI) in a simulated distribution feeder to create electric load models for each customer meter. Three different modeling approaches are discussed, and their effectiveness is measured by comparing the optimality of VVO solutions with a base case. The results show that the models derived from AMI data can accurately represent some end-use load behavior like total energy costs, but lose accuracy when considering more dynamic system behavior like voltage violations over small time intervals. This work helps to advance state-of-the-art, model-based VVO by providing a data-driven modeling technique which acknowledges that optimal distribution system control requires a treatment of the system which is dependent on time, voltage, and system conditions.

Thayer, Brandon L.↗

A multi-objective optimization approach to optimal sensor location problem in $\mathrm{IGCC}$ power plants

Integrated Gasification Combined Cycle (IGCC) power plants provide a cleaner and more efficient way to obtain energy from coal. In order to operate an IGCC power plant in a safe and stable manner, several input and output process parameters need to be monitored. However, due to economic and operational constraints, it is infeasible to place sensors at every input and output process parameter location. Hence, it becomes important to select the most effective sensor locations which lead to maximum information gain about the plant conditions. Practical issues present in an IGCC power plant, such as harsh physical conditions and variability in process parameters, make the optimal sensor location problem an especially complicated one. Further, sensors can have multiple objectives and they can produce uncertainties due to measurement errors. Here this work considers hybrid hardware and virtual sensing for advanced power systems with multiple objectives. In order to solve this real world large scale problem, we use a novel algorithm called Better Optimization of Nonlinear Uncertain Systems (BONUS). BONUS works in probability distribution space and avoids sampling for each optimization and derivative calculations iterations. A new algorithm for multi-objective optimization is also developed specifically for problem. The result of this nonlinear stochastic multi-objective problem is the non-dominated, or Pareto set, which provides trade-offs between various objectives like observability, cost, and thermal efficiency. This is the first attempt at solving the problem of optimal sensor deployment in advanced power plants, with consideration of hybrid hardware and virtual sensing and incorporation of uncertainty with multiple objectives.

01 COAL, LIGNITE, AND PEAT↗

Valuation of Distributed Wind Turbines Providing Multiple Market Services

The role of wind turbines has traditionally been limited to providing energy capacity to the grid, but the availability of smart inverters and recent regulatory changes provide the technical and policy capability for wind turbines to also provide ancillary services. However, in contrast to the technical and policy aspects, the valuation of distributed wind turbines providing such services has not been thoroughly studied. This paper presents an optimal market-participation method for distributed wind turbines and valuates different strategies in California Independent System Operator’s balancing area. The services include energy capacity, regulation up and down, and reserves. An optimization problem is formulated to determine optimal power output for each service and demonstrated using historical data for one complete year. The revenues from multiple services are quantified, and a sensitivity analysis is performed to relate market prices with revenues. It is found that the optimal strategy generates 6% more revenue compared to the revenue from participating in the energy market only. Also, the reduced energy prices in future scenarios increase the relative importance of market participation in ancillary services.

Bhatti, Bilal Ahmad↗

Model Improvement for ADMS Deployment

The objective of this research is to evaluate the performance of the advanced distribution management system (ADMS) Volt/VAR Optimization (VVO) application for different levels of model quality and different levels of measurement density -- using 4 different load days VVO optimized for conservative voltage regulation (CVR) and six feeders from Xcel Energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Placement and Sizing of Inverter-Based Renewable Systems in Multi-Phase Distribution Networks

This study develops a tractable formulation for optimal placement and sizing of inverter-based renewable systems in multi-phase distribution networks. The goal of the formulation is to minimize the cost of inverter installation, average power import, and average distributed generation curtailment. Threephase and single-phase inverter models are presented that preserve the underlying mappings between renewable uncertainty to power injection. The uncertainty of distributed generators (DGs) and loads are characterized by a finite set of scenarios. Linear multi-phase power flow approximations are used in conjunction with scenario reduction techniques to arrive at a tractable twostage stochastic formulation for optimal DG placement and sizing. First-stage decisions are locations for DG deployment and capacity sizes, and second-stage decisions include DG real power curtailment, reactive power support, as well as feeder voltage profile. The resulting formulation is a mixed-integer second-order cone program and can be solved efficiently either by existing optimization solvers or by relaxing the binary variables to the [0,1] interval. Simulation studies on standard multi-phase IEEE test feeders promise that optimal stochastic planning of DGs reduces costs during validation, compared to a scheme where uncertainty is only represented by its average value.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Correlation of FMISO simulations with pimonidazole-stained tumor xenografts: A question of O{sub 2} consumption?

Purpose: To compare a dedicated simulation model for hypoxia PET against tumor microsections stained for different parameters of the tumor microenvironment. The model can readily be adapted to a variety of conditions, such as different human head and neck squamous cell carcinoma (HNSCC) xenograft tumors. Methods: Nine different HNSCC tumor models were transplanted subcutaneously into nude mice. Tumors were excised and immunoflourescently labeled with pimonidazole, Hoechst 33342, and CD31, providing information on hypoxia, perfusion, and vessel distribution, respectively. Hoechst and CD31 images were used to generate maps of perfused blood vessels on which tissue oxygenation and the accumulation of the hypoxia tracer FMISO were mathematically simulated. The model includes a Michaelis–Menten relation to describe the oxygen consumption inside tissue. The maximum oxygen consumption rate M{sub 0} was chosen as the parameter for a tumor-specific optimization as it strongly influences tracer distribution. M{sub 0} was optimized on each tumor slice to reach optimum correlations between FMISO concentration 4 h postinjection and pimonidazole staining intensity. Results: After optimization, high pixel-based correlations up to R{sup 2} = 0.85 were found for individual tissue sections. Experimental pimonidazole images and FMISO simulations showed good visual agreement, confirming the validity of the approach. Median correlations per tumor model varied significantly (p < 0.05), with R{sup 2} ranging from 0.20 to 0.54. The optimum maximum oxygen consumption rate M{sub 0} differed significantly (p < 0.05) between tumor models, ranging from 2.4 to 5.2 mm Hg/s. Conclusions: It is feasible to simulate FMISO distributions that match the pimonidazole retention patterns observed in vivo. Good agreement was obtained for multiple tumor models by optimizing the oxygen consumption rate, M{sub 0}, whose optimum value differed significantly between tumor models.

60 APPLIED LIFE SCIENCES↗