Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMECHANICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

NASA's challenge for tomorrow

The early space probes provided our first detailed look at the planets, and demonstrated the critical role played by parts technology. The advanced orbital platform under development, the Space Station Freedom (which represents a pivotal step in the space program) contains about 5 million Electrical, Electronic and Electromechanical (EEE) parts. Thus, EEE parts continue to be crucial to mission success. The NASA EEE parts program establishes and directs policy and integration throughout the Agency. The EEE program structure, issues and solutions are described. The challenge presented by advanced electronic devices is discussed.

Barney, Daniel L.↗

Milliwatt mixer for small fluid samples

Mixing without excessive heating is sometimes needed for temperature-sensitive fluids. An inexpensive low-frequency electronic filter based on a mechanical resonator to produce a compact (16 mm) and low-power (1-3 mW) mixer for low viscosity fluids is developed. Tests made in air and methanol at room temperature and in fluoroform near its critical point are compared against the predictions of an electromechanical model.

Berg, Robert F.↗

Workspace visualization and time-delay telerobotic operations

The paper examines the performance of telerobotic tasks where the operator and robot are physically separated, and a comunication time delay of up to several seconds between them exists. This situation is applicable to space robotic servicing-assembly-maintenance operations on low earth or geosynchronous orbits with a ground-based command station. Attention is given to two developments which address advanced time-delay teleoperations for unstructured tasks: (1) the 'phantom robot', a real-time predictive graphics simulator developed to allow teleoperator eye-to-hand coordination or robot free-space kinematics under a time delay of several seconds; and (2) shared compliance control, a modified form of automatic electromechanical impedance control employed in parallel with manual position control to permit soft contact and grasp compliance with workpiece geometry under a time delay of several seconds.

Schenker, P. S.↗

Induction motor control

Electromechanical actuators developed to date have commonly ultilized permanent magnet (PM) synchronous motors. More recently switched reluctance (SR) motors have been advocated due to their robust characteristics. Implications of work which utilized induction motors and advanced control techniques are discussed. When induction motors are operated from an energy source capable of controlling voltages and frequencies independently, drive characteristics are obtained which are superior to either PM or SR motors. By synthesizing the machine frequency from a high-frequency carrier (nominally 20 kHz), high efficiencies, low distortion, and rapid torque response are available. At this time multiple horsepower machine drives were demonstrated, and work is on-going to develop a 20 hp average, 40 hp peak class of aerospace actuators. This effort is based upon high-frequency power distribution and management techniques developed by NASA for Space Station Freedom.

Hansen, Irving G.↗

In-situ measurement of sensitivity for a piezoelectric sensor

The paper presents a technique for the in situ and real-time measurement of sensitivity change in a piezoelectric accelerometer. This technique involves the electrical stimulation of the accelerometer's piezoelectric element in a 'diagnostic' frequency band and the measurement of the frequency response of the sensor's electromechanical properties. It is found that changes in the piezomechanical properties of a compression-mode accelerator, as measured by the autocalibration function, detected a relative change in sensitivity.

Flanagan, Patrick M.↗

TEXSYS - A large scale demonstration of model-based real-time control of a Space Station subsystem

A hybrid approach to qualitative and temporal reasoning, using a device-oriented model-based representation in conjunction with both consistency-based and classification diagnosis methods, can be effectively used to monitor and control a complex electromechanical system. An example of this approach is given in some recent tests of the Thermal Expert System (TEXSYS) in control of the Boeing Aerospace Thermal Bus System (BATBS), a prototype two-phase Space Station Freedom thermal bus. The constraints of realtime performance and changing target hardware led to significant changes in the initial approach, including a reduction in the use of deep structural reasoning and the addition of temporal reasoning capabilities. TEXSYS test results show the successful completion of both nominal control and fault recovery actions with the BATBS.

Glass, B. J.↗

Modeling Optics For Analyses Of Dynamics And Controls

Method of computing optical sensitivities of single- and multiple-element optical trains developed for analyses of dynamics of optoelectro-mechanical systems, including controlled optics (lenses, mirrors, prisms, and/or gratings mounted on electromechanical actuators) supported by flexible structure. Based on techniques of ray tracing and on matrix representation of each surface of each optical element.

Breckenridge, William C.↗

Scanning System Acquires Data At Designated Coordinates

Firmware in computer-controlled electromechanical scanning apparatus enables acquisition of data "on the fly" - as scanning head passes through designated positions on plane. Scanning motion steady, no sacrifice of positional accuracy. Control system has "Interrupt" structure commanding central processing unit to enter data-acquisition routine when x-y table reaches designated measurement positions. Adaptable to systems required to take data, or perform machining operations at designated positions.

Chern, E. James↗

Solid state devices

The Solid State Device research program is directed toward developing innovative devices for space remote and in-situ sensing, and for data processing. Innovative devices can result from the standard structures in innovative materials such as low and high temperature superconductors, strained layer superlattices, or diamond films. Innovative devices can also result from innovative structures achieved using electron tunneling or nanolithography in standard materials. A final step is to use both innovative structures and innovative materials. A new area of emphasis is the miniaturization of sensors and instruments molded by using the techniques of electronic device fabrication to micromachine silicon into micromechanical and electromechanical sensors and actuators.

Source record↗

Collision avoidance sensor skin

The objective was to totally eliminate the possibility of a robot (or any mechanism for that matter) inducing a collision in space operations. We were particularly concerned that human beings were safe under all circumstances. This was apparently accomplished, and it is shown that GSFC has a system that is ready for space qualification and flight. However, it soon became apparent that much more could be accomplished with this technology. Payloads could be made invulnerable to collision avoidance and the blind spots behind them eliminated. This could be accomplished by a simple, non-imaging set of 'Capaciflector' sensors on each payload. It also is evident that this system could be used to align and dock the system with a wide margin of safety. Throughout, lighting problems could be ignored, and unexpected events and modeling errors taken in stride. At the same time, computational requirements would be reduced. This can be done in a simple, rugged, reliable manner that will not disturb the form factor of space systems. It will be practical for space applications. The lab experiments indicate we are well on the way to accomplishing this. Still, the research trail goes deeper. It now appears that the sensors can be extended to end effectors to provide precontact information and make robot docking (or any docking connection) very smooth, with minimal loads impacted back into the mating structures. This type of ability would be a major step forward in basic control techniques in space. There are, however, baseline and restructuring issues to be tackled. The payloads must get power and signals to them from the robot or from the astronaut servicing tool. This requires a standard electromechanical interface. Any of several could be used. The GSFC prototype shown in this presentation is a good one. Sensors with their attendant electronics must be added to the payloads, end effectors, and robot arms and integrated into the system.

Source record↗

Kate's Model Verification Tools

Kennedy Space Center's Knowledge-based Autonomous Test Engineer (KATE) is capable of monitoring electromechanical systems, diagnosing their errors, and even repairing them when they crash. A survey of KATE's developer/modelers revealed that they were already using a sophisticated set of productivity enhancing tools. They did request five more, however, and those make up the body of the information presented here: (1) a transfer function code fitter; (2) a FORTRAN-Lisp translator; (3) three existing structural consistency checkers to aid in syntax checking their modeled device frames; (4) an automated procedure for calibrating knowledge base admittances to protect KATE's hardware mockups from inadvertent hand valve twiddling; and (5) three alternatives for the 'pseudo object', a programming patch that currently apprises KATE's modeling devices of their operational environments.

Morgan, Steve↗

Advanced electric motor technology: Flux mapping

This report contains the assumptions, mathematical models, design methodology, and design points involved with the design of an electromechanical actuator (EMA) suitable for directing the thrust vector of a large MSFC/NASA launch vehicle. Specifically the design of such an actuator for use on the upcoming liquid fueled National Launch System (NLS) is considered culminating in a point design of both the servo system and the electric motor needed. A major thrust of the work is in selecting spur gear and roller screw reduction ratios to achieve simultaneously wide bandwidth, maximum power transfer, and disturbance rejection while meeting specified horsepower requirements at a given stroking speed as well as a specified maximum stall force. An innovative feedback signal is utilized in meeting these diverse objectives.

Doane, George B., III↗

Experiences in the development of rotary joints for robotic manipulators in space applications

European developments in robotics for space applications have resulted in human arm-like manipulators with six or more rotational degrees of freedom. The rotary joints including their own electromechanical actuator and feedback sensors must be very compact units. The specific joint concept is presented as evolved so far. The problems encountered during the first hardware development phases are covered on both component and joint level.

Priesett, Klaus↗

Mechanisms of the Space Active Vibration Isolation (SAVI)

The Space Active Vibration Isolation (SAVI) is a concept for vibration isolation of one body from another with simultaneous precise control in 6 Degrees Of Freedom (DOF). SAVI achieves this using a combination of electromechanical linear actuators and magnetic actuators. Other mechanisms of interest include a structure for simulating the body being pointed, an apparatus to simulate the body that is the vibration source, and mechanisms to off-load the weight of each of these two bodies from the experiment to approximate a zero-g condition. A SAVI was built and tested to demonstrate these capabilities.

Schmitt, Frank↗

Model compilation: An approach to automated model derivation

An approach is introduced to automated model derivation for knowledge based systems. The approach, model compilation, involves procedurally generating the set of domain models used by a knowledge based system. With an implemented example, how this approach can be used to derive models of different precision and abstraction is illustrated, and models are tailored to different tasks, from a given set of base domain models. In particular, two implemented model compilers are described, each of which takes as input a base model that describes the structure and behavior of a simple electromechanical device, the Reaction Wheel Assembly of NASA's Hubble Space Telescope. The compilers transform this relatively general base model into simple task specific models for troubleshooting and redesign, respectively, by applying a sequence of model transformations. Each transformation in this sequence produces an increasingly more specialized model. The compilation approach lessens the burden of updating and maintaining consistency among models by enabling their automatic regeneration.

Keller, Richard M.↗

Precision magnetic suspension linear bearing

We have shown the design and analyzed the electromechanics of a linear motor suitable for independently controlling two suspension degrees of freedom. This motor, at least on paper, meets the requirements for driving an X-Y stage of 10 Kg mass with about 4 m/sq sec acceleration, with travel of several hundred millimeters in X and Y, and with reasonable power dissipation. A conceptual design for such a stage is presented. The theoretical feasibility of linear and planar bearings using single or multiple magnetic suspension linear motors is demonstrated.

Trumper, David L.↗

An electrostatically suspended, micro-mechanical rate gyroscope

SatCon Technology has performed a study of micromechanical gyroscopes. The goals of this program were to define a baseline system configuration and establish technical feasibility for proof of principle and prototype fabrication. This report documents the research and presents the baseline mechanical design, sensors, control systems, and electronics. This section presents a project overview and specific technical objectives. Section 2 contains a background on micromechanical technology. Section 3 contains the microgyroscope specifications and configurations. Section 4 contains the electromechanical design. Section 5 outlines the control and electronics. Section 6 presents a preliminary sequence for microfabrication of the baseline design, and Section 7 contains conclusions and recommendations for further work.

Hawkey, Timothy↗

Payload retention device

A payload retention device for grappling and retaining a payload in docked position on a supporting structure in the cargo bay of a space vehicle is presented. The device comprises a two-fault tolerant electromagnetic grappling system comprising electromagnets for attracting and grappling a grapple strike plate affixed to the payload when in proximity thereto and an electromechanical latching assembly comprising a pair of independent latching subassemblies. Each subassembly comprises a set of latching pawls which are driven into latching and unlatching positions relative to a grappled payload by a pair of gearmotors, each equipped with a ratchet clutch drive mechanism which is two-fault tolerant with respect to latching such that only one gearmotor of the four needs to be operational to effect a latch of the payload but is single fault tolerant with respect to release of a latched payload. Sensors are included for automatically sensing the magnetic grappling of a payload and for automatically de-energizing the gearmotors of the latching subassemblies when a latch condition is achieved.

Monford, Leo G., Jr.↗