Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Beneficial Use of Harvested Ponded Fly Ash and Landfilled FGD Materials for High-Volume Surface Mine Reclamation

The overall motivation of this project was to demonstrate at laboratory, bench-scale, and full-scale demonstration levels that (a) coal ash surface impoundments can go through closure by removal as per USEPA and state regulations so that the material can be used as is (other than draining free water using CCRs piles) in high-volume beneficial applications, (b) FGD material from closed out FGD facilities can be excavated and recompacted for coal mine reclamation, and (c) harvested CCRs can be beneficially utilized (providing a net environmental gain) in large-volumes for reclamation at abandoned coal mine sites across the US, especially in the Eastern and Midwest coal mining regions. The objectives of this project were to: 1) promote the safe and cost-effective closure by removal of coal ash impoundments, 2) harvest landfilled FGD, and 3) promote the high-volume beneficial use of these harvested CCRs in the reclamation of abandoned surface coal mine sites across the eastern and midwestern coal mining regions of the United States. The major tasks carried out for this project are summarized below: 1) Conesville Full-Scale Demonstration Project: About 2 million tons of harvested CCR materials from the closure by removal of an inactive fly ash pond and an adjacent old FGD landfill were used for the full-scale demonstration project to fully reclaim a nearby partially completed abandoned surface coal mine. Site monitoring for the project duration was carried out and results are discussed. 2) Laboratory Testing: Geotechnical and environmental testing of harvested ponded fly ash and landfilled FGD material at the former Conesville power plant were carried out. Completing the laboratory testing allowed for QA/QC for the full-scale site construction and informed the formulation of the risk analysis. 3) Risk Analysis: We developed a reliable computational model for fate and transport. We used these models and the rich set of monitored data for the Conesville site to analyze risks to human health and ecological risks associated with high-volume surface mine reclamation using harvested CCRs. 4) GIS Siting Study: A Geographic Information System (GIS) study was carried out for three states in the Eastern coal mining region and two states in the Midwest coal region. This effort provided site specific GIS information for five states and allowed us to establish protocols that other states can follow in implementing their own state specific GIS study.

01 COAL, LIGNITE, AND PEAT↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have beendeveloped for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TU-AB-201-03: A Robot for the Automated Delivery of An Electromagnetic Tracking Sensor for the Localization of Brachytherapy Catheters

Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The system consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Special tooling for joining tubing in place

The Saturn S-II stage and the Apollo spacecraft will include in their design and construction various pressurized tubing systems that will encounter service temperatures of 280° F to -423° F. Design engineering and reliability requirements and weight restrict ions have dictated new concepts to assure leak-tight joints for rocket engine fuel lines, pressurization systems, utility systems, and hydraulic systems. An investigation was initiated at North American Aviation, Inc., Space and Information Systems Division, utilizing the in-place automatically controlled miniaturized fusion-welding equipment originally developed by the Los Angeles Division of NAA and modified to meet the needs of Apollo and Saturn welded tubular systems. The objective was to make circumferential flanged weld joints in any position in 304L stainless for Saturn S-II and sleeve-type joints in 304L for Apollo. Inconel X, commercially pure titanium, 5052-0 aluminum, and 6061 T6 aluminum were also tested experimentally. Extensive environmental, static, and dynamic testing programs were conducted to determine the as-welded mechanical properties, design allowables, and reliability for the tube joints. This paper discusses both the experimental and production phases. Subsequently, the new tube welding process was approved and incorporated into manufacturing fabrication methods for tube joining.

Saturn S-II stage↗

Flight and ground tests of a GOES satellite time receiver for satellite communications applications

A satellite time receiver was tested in various environmental conditions during the past year. The commercial receiver designed to work with the National Oceanic and Atmospheric Administration's (NOAA) Geostationary Operational Environmental Satellites (GOES). The test program included operation at low elevation during flight in a military cargo aircraft and long term comparison with laboratory standards. The GOES satellite time receiver offers an opportunity to provide easy wide area coverage synchronization at low cost.

Swanson, R. L.↗

Test methods for optical disk media characteristics (for 356 mm ruggedized magneto-optic media)

Standard test methods for computer storage media characteristics are essential and allow for conformance to media interchange standards. The test methods were developed for 356 mm two-sided laminated glass substrate with a magneto-optic active layer media technology. These test methods may be used for testing other media types, but in each case their applicability must be evaluated. Test methods are included for a series of different media characteristics, including operational, nonoperational, and storage environments; mechanical and physical characteristics; and substrate, recording layer, and preformat characteristics. Tests for environmental qualification and media lifetimes are also included. The best methods include testing conditions, testing procedures, a description of the testing setup, and the required calibration procedures.

Podio, Fernando L.↗

Testing and Results of Human Metabolic Simulation Utilizing Ultrasonic Nebulizer Technology for Water Vapor Generation

Life support technology must be evaluated thoroughly before ever being implemented into a functioning design. A major concern during that evaluation is safety. The ability to mimic human metabolic loads allows test engineers to evaluate the effectiveness of new technologies without risking injury to any actual humans. The main function of most life support technologies is the removal of carbon dioxide (CO2) and water (H2O) vapor. As such any good human metabolic simulator (HMS) will mimic the human body s ability to produce these items. Introducing CO2 into a test chamber is a very straightforward process with few unknowns so the focus of this particular new HMS design was on the much more complicated process of introducing known quantities of H2O vapor on command. Past iterations of the HMS have utilized steam which is very hard to keep in vapor phase while transporting and injecting into a test chamber. Also steam adds large quantities of heat to any test chamber, well beyond what an actual human does. For the new HMS an alternative approach to water vapor generation was designed utilizing ultrasonic nebulizers as a method for creating water vapor. Ultrasonic technology allows water to be vibrated into extremely tiny pieces (2-5 microns) and evaporate without requiring additional heating. Doing this process inside the test chamber itself allows H2O vapor generation without the unwanted heat and the challenging process of transporting water vapor. This paper presents the design details as well as results of all initial and final acceptance system testing. Testing of the system was performed at a range of known human metabolic rates in both sea-level and reduced pressure environments. This multitude of test points fully defines the systems capabilities as they relate to actual environmental systems testing.

Stubbe, Matthew↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Base-Shake↗

Geographic and social disparities in exposure to air neurotoxicants at U.S. public schools

Highlights: • Ambient neurotoxicants pose serious risks at US public schools. • There are social and spatial disparities in ambient neurotoxicant risks. • One-third of all schools in EPA Region 2 are at “high risk” for neurotoxicant exposure. • Schools with higher % of Hispanic, black, and Asian students face disparate risks. • Schools serving the youngest (vs. older) students face disparate risks. Children are especially vulnerable to the health and developmental impacts of environmental hazards and they spend significant portions of their days at school. Yet there are no national-level studies examining school-level environmental inequalities and few have examined disparate exposure to neurological air toxicants, even though chronic exposure to air pollution impacts children's brain functioning. We paired information about the geographic locations and demographics of each public school in the US with air neurotoxicant exposure estimates pertaining to 24 known neurotoxicants included in the US Environmental Protection Agency's National Air Toxics Assessment. Using bivariate and multivariate statistics, we tested for environmental injustices in air neurotoxicant exposure at 84,969 US public schools. Metropolitan New York City (EPA Region 2) is the geographic region most burdened by air neurotoxicant exposures at schools since one-third of all schools in that region are in the top 10% (at {sup h}igh risk{sup )} for ambient neurotoxicant exposure among all schools nationwide. Students attending “high risk” public schools nationwide are significantly more likely to be eligible for free/reduced price meals, and to be Hispanic, black, or Asian/Pacific Islander (API). They are significantly less likely to be white or of another race. In a multivariate generalized estimating equation controlling for school district effects, schools with greater proportions of Hispanic, black, and API students, schools with higher enrollment, and schools located in more urban (vs. rural) counties face greater risks. Schools serving the youngest students (e.g., pre-kindergarten) have greater levels of risk than schools serving older students. Across all analyses, this study shows that racial/ethnic minority children are bearing the brunt of air neurotoxicant exposures at school, which may be unequally impacting their school performance and future potential.

54 ENVIRONMENTAL SCIENCES↗

A test program for solar collectors

Rigorous environmental and performance tests qualify solar collector for use in residential solar-energy systems. Testing over 7 month period examined pressurized effects, wind and snow loading, hail damage, solar and thermal degradation, effects of pollutants, efficiency, and outgassing. Test procedures and results are summarized in tables, graphs, and text.

Source record↗

Space Station Environmental Control and Life Support System Test Facility at Marshall Space Flight Center

Different aspects of Space Station Environmental Control and Life Support System (ECLSS) testing are currently taking place at Marshall Space Flight Center (MSFC). Unique to this testing is the variety of test areas and the fact that all are located in one building. The north high bay of building 4755, the Core Module Integration Facility (CMIF), contains the following test areas: the Subsystem Test Area, the Comparative Test Area, the Process Material Management System (PMMS), the Core Module Simulator (CMS), the End-use Equipment Facility (EEF), and the Pre-development Operational System Test (POST) Area. This paper addresses the facility that supports these test areas and briefly describes the testing in each area. Future plans for the building and Space Station module configurations will also be discussed.

Springer, Darlene↗

Impact of Drilling Operations on Lunar Volatiles Capture: Thermal Vacuum Tests

In Situ Resource Utilization (ISRU) enables future planetary exploration by using local resources to supply mission consumables. This idea of 'living off the land' has the potential to reduce mission cost and risk. On the moon, water has been identified as a potential resource (for life support or propellant) at the lunar poles, where it exists as ice in the subsurface. However, the depth and content of this resource has yet to be confirmed on the ground; only remote detection data exists. The upcoming Resource Prospector mission (RP) will 'ground-truth' the water using a rover, drill, and the RESOLVE science package. As the 2020 planned mission date nears, component level hardware is being tested in relevant lunar conditions (thermal vacuum). In August 2014 a series of drilling tests were performed using the Honeybee Robotics Lunar Prospecting Drill inside a 'dirty' thermal vacuum chamber at the NASA Glenn Research Center. The drill used a unique auger design to capture and retain the lunar regolith simulant. The goal of these tests was to investigate volatiles (water) loss during drilling and sample transfer to a sample crucible in order to validate this regolith sampling method. Twelve soil samples were captured over the course of two tests at pressures of 10(exp-5) Torr and ambient temperatures between -80C to -20C. Each sample was obtained from a depth of 40 cm to 50 cm within a cryogenically frozen bed of NU-LHT-3M lunar regolith simulant doped with 5 wt% water. Upon acquisition, each sample was transferred and hermetically sealed inside a crucible. The samples were later baked out to determine water wt% and in turn volatile loss by following ASTM standard practices. Of the twelve tests, four sealed properly and lost an average of 30% of their available water during drilling and transfer. The variability in the results correlated well with ambient temperature (lower the temperature lower volatiles loss) and the trend agreed with the sublimation rates for the same temperature. Moisture retention also correlated with quantity of sample: a larger amount of material resulted in less water loss. The drilling process took an average of 10 minutes to capture and transfer each sample. The drilling power was approximately 20 Watt with a Weight on Bit of approximately 30 N. The bit temperature indicated little heat input into formation during the drilling process.

drilling↗

Regolith Volatile Recovery at Simulated Lunar Environments

Lunar Polar Volatiles: Permanently shadowed craters at the lunar poles contain water, 5 wt according to LCROSS. Interest in water for ISRU applications. Desire to ground truth water using surface prospecting e.g. Resource Prospector and RESOLVE. How to access subsurface water resources and accurately measure quantity. Excavation operations and exposure to lunar environment may affect the results. Volatile capture tests: A series a ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations. Sample removal and transfer. Volatiles loss during sampling operations. Concept of operations, Instrumentation. This presentation is a progress report on volatiles capture results from these tests with lunar polar drill prototype hardware.

thermal vacuum tests↗

Sample acquisition and instrument deployment

Progress is reported in developing the Sample Acquisition and Instrument Deployment (SAID) system, a robotic system for deploying science instruments and acquiring samples for analysis. The system is a conventional four degree of freedom manipulator 2 meters in length. A baseline design has been achieved through analysis and trade studies. The design considers environmental operating conditions on the surface of Mars, as well as volume constraints on proposed Mars landers. Control issues have also been studied, and simulations of joint and tip movements have been performed. The systems have been fabricated and tested in environmental chambers, as well as soil testing and robotic control testing.

Boyd, Robert C.↗

Environmental charging of spacecraft surfaces: Tests of thermal control materials for use on the global positioning system flight space vehicle. Part 1: Specimens 1 to 5

The NASA/USAF program on Environmental Charging of Spacecraft Surfaces consists of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets and second surface mirrors of the type to be used on the Global Positioning System Flight Space Vehicle were tested to determine their response to electron flux. The primary result observed was that the ground connection of the metal layers of the blanket, as made by the baseline grounding technique using serrated washers and grommets, deteriorated with time at test. The discharges observed on the blankets were the glow type, not the 'lightning' strike observed on past specimens. Testing was performed at ambient laboratory temperatures.

Stevens, N. J.↗