Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experimental Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55

Enhancement of optical absorption by modulation of the oxygen flow of TiO{sub 2} films deposited by reactive sputtering

Oxygen-deficient TiO{sub 2} films with enhanced visible and near-infrared optical absorption have been deposited by reactive sputtering using a planar diode radio frequency magnetron configuration. It is observed that the increase in the absorption coefficient is more effective when the O{sub 2} gas supply is periodically interrupted rather than by a decrease of the partial O{sub 2} gas pressure in the deposition plasma. The optical absorption coefficient at 1.5 eV increases from about 1 Multiplication-Sign 10{sup 2} cm{sup -1} to more than 4 Multiplication-Sign 10{sup 3} cm{sup -1} as a result of the gas flow discontinuity. A red-shift of {approx}0.24 eV in the optical absorption edge is also observed. High resolution transmission electron microscopy with composition analysis shows that the films present a dense columnar morphology, with estimated mean column width of 40 nm. Moreover, the interruptions of the O{sub 2} gas flow do not produce detectable variations in the film composition along its growing direction. X-ray diffraction and micro-Raman experiments indicate the presence of the TiO{sub 2} anatase, rutile, and brookite phases. The anatase phase is dominant, with a slight increment of the rutile and brookite phases in films deposited under discontinued O{sub 2} gas flow. The increase of optical absorption in the visible and near-infrared regions has been attributed to a high density of defects in the TiO{sub 2} films, which is consistent with density functional theory calculations that place oxygen-related vacancy states in the upper third of the optical bandgap. The electronic structure calculation results, along with the adopted deposition method and experimental data, have been used to propose a mechanism to explain the formation of the observed oxygen-related defects in TiO{sub 2} thin films. The observed increase in sub-bandgap absorption and the modeling of the corresponding changes in the electronic structure are potentially useful concerning the optimization of efficiency of the photocatalytic activity and the magnetic doping of TiO{sub 2} films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

60 APPLIED LIFE SCIENCES↗

Status of vibrational structure in {sup 62}Ni

Measurements consisting of {gamma}-ray excitation functions and angular distributions were performed using the (n,n{sup '{gamma}}) reaction on {sup 62}Ni. The excitation function data allowed us to check the consistency of the placement of transitions in the level scheme. From {gamma}-ray angular distributions, the lifetimes of levels up to {approx}3.8 MeV in excitation energy were extracted with the Doppler-shift attenuation method. The experimentally deduced values of reduced transition probabilities were compared with the predictions of the quadrupole vibrator model and with large-scale shell model calculations in the fp shell configuration space. Two-phonon states were found to exist with some notable deviation from the predictions of the quadrupole vibrator model, but no evidence for the existence of three-phonon states could be established. Z=28 proton core excitations played a major role in understanding the observed structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A generalized linear-quadratic model incorporating reciprocal time pattern of radiation damage repair

Purpose: It has been conventionally assumed that the repair rate for sublethal damage (SLD) remains constant during the entire radiation course. However, increasing evidence from animal studies suggest that this may not the case. Rather, it appears that the repair rate for radiation-induced SLD slows down with increasing time. Such a slowdown in repair would suggest that the exponential repair pattern would not necessarily accurately predict repair process. As a result, the purpose of this study was to investigate a new generalized linear-quadratic (LQ) model incorporating a repair pattern with reciprocal time. The new formulas were tested with published experimental data. Methods: The LQ model has been widely used in radiation therapy, and the parameter G in the surviving fraction represents the repair process of sublethal damage with T{sub r} as the repair half-time. When a reciprocal pattern of repair process was adopted, a closed form of G was derived analytically for arbitrary radiation schemes. The published animal data adopted to test the reciprocal formulas. Results: A generalized LQ model to describe the repair process in a reciprocal pattern was obtained. Subsequently, formulas for special cases were derived from this general form. The reciprocal model showed a better fit to the animal data than the exponential model, particularly for the ED50 data (reduced {chi}{sup 2}{sub min} of 2.0 vs 4.3, p = 0.11 vs 0.006), with the following gLQ parameters: {alpha}/{beta} = 2.6-4.8 Gy, T{sub r} = 3.2-3.9 h for rat feet skin, and {alpha}/{beta} = 0.9 Gy, T{sub r} = 1.1 h for rat spinal cord. Conclusions: These results of repair process following a reciprocal time suggest that the generalized LQ model incorporating the reciprocal time of sublethal damage repair shows a better fit than the exponential repair model. These formulas can be used to analyze the experimental and clinical data, where a slowing-down repair process appears during the course of radiation therapy.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Technical Note: Procedure for the calibration and validation of kilo-voltage cone-beam CT models

Purpose: The aim of this work is to propose a general and simple procedure for the calibration and validation of kilo-voltage cone-beam CT (kV CBCT) models against experimental data. Methods: The calibration and validation of the CT model is a two-step procedure: the source model then the detector model. The source is described by the direction dependent photon energy spectrum at each voltage while the detector is described by the pixel intensity value as a function of the direction and the energy of incident photons. The measurements for the source consist of a series of dose measurements in air performed at each voltage with varying filter thicknesses and materials in front of the x-ray tube. The measurements for the detector are acquisitions of projection images using the same filters and several tube voltages. The proposed procedure has been applied to calibrate and assess the accuracy of simple models of the source and the detector of three commercial kV CBCT units. If the CBCT system models had been calibrated differently, the current procedure would have been exclusively used to validate the models. Several high-purity attenuation filters of aluminum, copper, and silver combined with a dosimeter which is sensitive to the range of voltages of interest were used. A sensitivity analysis of the model has also been conducted for each parameter of the source and the detector models. Results: Average deviations between experimental and theoretical dose values are below 1.5% after calibration for the three x-ray sources. The predicted energy deposited in the detector agrees with experimental data within 4% for all imaging systems. Conclusions: The authors developed and applied an experimental procedure to calibrate and validate any model of the source and the detector of a CBCT unit. The present protocol has been successfully applied to three x-ray imaging systems. The minimum requirements in terms of material and equipment would make its implementation suitable in most clinical environments.

60 APPLIED LIFE SCIENCES↗

Absolute NMR shielding scales and nuclear spin–rotation constants in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br and {sup 127}I)

We present nuclear spin–rotation constants, absolute nuclear magnetic resonance (NMR) shielding constants, and shielding spans of all the nuclei in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br, {sup 127}I), calculated using coupled-cluster singles-and-doubles with a perturbative triples (CCSD(T)) correction theory, four-component relativistic density functional theory (relativistic DFT), and non-relativistic DFT. The total nuclear spin–rotation constants determined by adding the relativistic corrections obtained from DFT calculations to the CCSD(T) values are in general in agreement with available experimental data, indicating that the computational approach followed in this study allows us to predict reliable results for the unknown spin–rotation constants in these molecules. The total NMR absolute shielding constants are determined for all the nuclei following the same approach as that applied for the nuclear spin–rotation constants. In most of the molecules, relativistic effects significantly change the computed shielding constants, demonstrating that straightforward application of the non-relativistic formula relating the electronic contribution to the nuclear spin–rotation constants and the paramagnetic contribution to the shielding constants does not yield correct results. We also analyze the origin of the unusually large absolute shielding constant and its relativistic correction of gold in AuF compared to the other gold monohalides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of the structural, electronic, elastic and thermodynamic properties of CuAl2X4 (X = O, S) spinel structure

Highlights: • Fundamental properties of CuAl{sub 2}X{sub 4} (X = O, S) aluminate spinels have been investigated. • The pressure dependence of the elastic constants C{sub ij} can be successfully fit by a straight line. • CuAl{sub 2}X{sub 4} (X = O, S) compounds are mechanically stable at ambient conditions. • Temperature and pressure dependences of some macroscopic parameters are achieved. - Abstract: The structural, electronic, elastic and thermodynamic properties of oxo- and thio-spinels have been predicted based on the ultrasoft pseudo-potential scheme as implemented in the CASTEP code. The exchange-correlation potential was treated within the generalized gradient approximation (GGA-PBE). The calculated structural parameters such as lattice constants and internal parameters are in good agreement with the available experimental data. The ground state electronic band structure revealed that CuAl{sub 2}X{sub 4} (XO, S) spinels are direct band gap semiconductors with a transition along Γ-Γ symmetry points. The calculated values of elastic constants satisfy the Born criteria at ambient conditions and confirm that the spinel structures of CuAl{sub 2}O{sub 4} and CuAl{sub 2}S{sub 4} are mechanically stable. The thiospinel structure may have a phase transition under pressure, due to the negative value of C{sub 44}. The influence of temperature and pressure on macroscopic characteristics of CuAl{sub 2}O{sub 4} and CuAl{sub 2}S{sub 4} compounds was estimated using the quasi-harmonic Debye model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Kinetic simulations of argon dusty plasma afterglow including metastable atom kinetics

The afterglow of a dusty plasma of rf discharge in argon is simulated by the particle-in-cell-Monte Carlo collision (PIC-MCC) method. The experimental observation that heavy dust contamination of plasma leads to an anomalous increase in the electron density at the beginning of afterglow is explained by release of electrons from the dust surface. Under the assumption that the floating potential of particles is in equilibrium with plasma conditions, the fast cooling of electrons in afterglow plasma due to a rapid escape of hot electrons from the volume leads to a decrease in the magnitude of the floating potential and hence to a loss of charge by dust. The intensive desorption of electrons from nanoparticles is the origin of anomalous behavior of the electron density. At the next stage of afterglow, when the electrons become cool, the plasma decay is defined by ambipolar diffusion. The effect of metastable argon atoms is also considered. Additional ionization due to metastable atom collisions affects the electron temperature but does not change the behavior of the electron density qualitatively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active sites of ligand-protected Au{sub 25} nanoparticle catalysts for CO{sub 2} electroreduction to CO

Recent experimental studies have reported the electrochemical reduction of carbon dioxide (CO{sub 2}) into CO at atomically precise negatively charged Au{sub 25}{sup −} nanoclusters. The studies showed CO{sub 2} conversion at remarkably low overpotentials, but the exact mechanisms and nature of the active sites remain unclear. We used first-principles density functional theory and continuum solvation models to examine the role of the cluster during electrochemical CO{sub 2} reduction and analyze the free energies of proposed intermediate species. Contrary to previous assumptions, our results show that the fully ligand protected cluster is not an active CO{sub 2} reduction catalyst because formation of the crucial carboxyl intermediate required very high electrochemical potentials. Instead, our calculations suggest that the reduction process likely occurs on a dethiolated gold site, and adsorbed carboxyl intermediate formation was significantly stabilized at dethiolated gold sites. These findings point to the crucial role of exposed metal sites during electrochemical CO{sub 2} reduction at gold nanocluster catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Geothermal Drilling Using Millimeter Wave Technology (Final Technical Research Report)

Conventional drilling methods are very mature, but still have difficulty drilling through very deep,very hard and hot rocks for geothermal, nuclear waste entombment and oil and gas applications.This project demonstrated the capabilities of utilizing only high energy beams to drill such rocks,commonly called ‘Direct Energy Drilling’, which has been the dream of industry since the invention of the laser in the 1960s. A new region of the electromagnetic spectrum, millimeter wave (MMW) wavelengths at 30-300 giga-hertz (GHz) frequency was used to accomplish this feat. To demonstrate MMW beam drilling capabilities a lab bench waveguide delivery, monitoring and instrument system was designed, built and tested around an existing (but non-optimal) 28 GHz frequency, 10 kilowatt (kW) gyrotron. Low waveguide efficiency, plasma generation and reflected power challenges were overcome. Real-time monitoring of the drilling process was also demonstrated. Then the technical capability of using only high power intense millimeter waves to melt (with some vaporization) four different rock types (granite, basalt, sandstone, limestone) was demonstrated through 36 bench tests. Full bore drilling up to 2” diameter (size limited by the available MMW power) was demonstrated through granite and basalt samples. The project also demonstrated that MMW beam transmission losses through high temperature (260°C, 500oF), high pressure (34.5 MPa, 5000 psi) nitrogen gas was below the error range of the meter long path length test equipment and instruments utilized. To refine those transmission losses closer, to allow extrapolation to very great distances, will require a new test cell design and higher sensitivity instruments. All rock samples subjected to high peak temperature by MMW beams developed fractures due to thermal stresses, although the peak temperature was thermodynamically limited by radiative losses. Therefore, this limited drill rate and rock strength data were not able to be determined experimentally. New methods to encapsulate larger rock specimens must be developed and higher power intensities are needed to overcome these limitations. It was demonstrated that rock properties are affected (weakening then strengthened) by exposure to high temperatures. Since only MMW beams can economically reach rock temperatures of over 1650°C, even exceeding 3000°C, that can cause low viscosity melts or vaporization of rocks. Future encapsulated rock specimens must provide sufficiently large sizes of thermally impacted material to provide for the necessary rock strength, permeability and other analyzes required. Multiple MMW field systems, tools and methods for drilling and lining were identified. It was concluded that forcing a managed over-pressure drilling operation would overcome water influx and hot rock particulates handling problems, while simultaneously forming the conditions necessary to create a strong, sealing rock melt liner. Materials that contact hot rock surfaces were identified for further study. High power windows and gases for beam transmission under high pressures are critical paths for some of the MMW drilling systems. Straightness/ alignment can be a great benefit or a problem, especially if a MMW beam is transmitted through an existing, conventionally drilled bore.

04 OIL SHALES AND TAR SANDS↗

Why diamond dimensions and electrode geometry are crucial for small photon beam dosimetry

Recent use of very small photon beams (down to 4 mm) in stereotactic radiotherapy requires new detectors to accurately determine the delivered dose. Diamond detectors have been presented in the literature as an attractive candidate for this application, due to their small detection volume and the diamond atomic number (Z = 6) which is close to water effective atomic number (Zeff ∼ 7.42). However, diamond exhibits a density 3.51 times greater than that of water and recent studies using Monte Carlo simulations have demonstrated the drawback of a high-density detector on small beam output factors. The current study focuses on geometrical parameters of diamond detector, namely, the diamond dimensions and the electrode geometry, in order to solve the dosimetric issues still observed in small photon beams with diamond detectors. To give better insights to these open questions, we have used both computational method and experimental analysis. This study highlighted that reducing diamond dimensions is crucial for small beam output factor measurements and to limit the influence of its high density. Furthermore, electrodes covering the whole diamond surface were essential for a dose rate independence of the diamond detector. The optimal dosimeter derived from this work presented small diamond dimensions of approximately 1 × 1 × 0.15 mm{sup 3}, with diamond-like-carbon electrodes covering the whole diamond surface. A dose rate independence of this diamond detector (better than 0.5% over a wide range of dose rates available on a stereotactic dedicated facility) was obtained due to the electrode geometry. Concerning the output factor measurements, a good agreement (better than 1.1%) was observed between this carbon material detector and two types of passive dosimeters (LiF microcubes and EBT2 radiochromic films) for all beam sizes except the smallest field of 0.6 × 0.6 cm{sup 2} with a deviation of 2.6%. This new study showed the high performance of this diamond detector in small photon beams, in comparison with various commercially available passive and active dosimeters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extraction of the muon signals recorded with the surface detector of the Pierre Auger Observatory using recurrent neural networks

The Pierre Auger Observatory, at present the largest cosmic-ray observatory ever built, is instrumented with a ground array of 1600 water-Cherenkov detectors, known as the Surface Detector (SD). The SD samples the secondary particle content (mostly photons, electrons, positrons and muons) of extensive air showers initiated by cosmic rays with energies ranging from 1017eV up to more than 1020eV. Measuring the independent contribution of the muon component to the total registered signal is crucial to enhance the capability of the Observatory to estimate the mass of the cosmic rays on an event-by-event basis. However, with the current design of the SD, it is difficult to straightforwardly separate the contributions of muons to the SD time traces from those of photons, electrons and positrons. In this paper, we present a method aimed at extracting the muon component of the time traces registered with each individual detector of the SD using Recurrent Neural Networks. We derive the performances of the method by training the neural network on simulations, in which the muon and the electromagnetic components of the traces are known. We conclude this work showing the performance of this method on experimental data of the Pierre Auger Observatory. We find that our predictions agree with the parameterizations obtained by the AGASA collaboration to describe the lateral distributions of the electromagnetic and muonic components of extensive air showers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Taylor Expansion-Based Adaptive Design Strategy for Global Surrogate Modeling With Applications in Groundwater Modeling

Global sensitivity analysis (GSA) and uncertainty quantification (UQ) for groundwater modeling are challenging because of the model complexity and significant computational requirements. To reduce the massive computational cost, a cheap-to-evaluate surrogate model is usually constructed to approximate and replace the expensive groundwater models in the GSA and UQ. Constructing an accurate surrogate requires actual model simulations on a number of parameter samples. Thus, a robust experimental design strategy is desired to locate informative samples so as to reduce the computational cost in surrogate construction and consequently to improve the efficiency in the GSA and UQ. In this study, we develop a Taylor expansion-based adaptive design (TEAD) that aims to build an accurate global surrogate model with a small training sample size. TEAD defines a novel hybrid score function to search informative samples, and a robust stopping criterion to terminate the sample search that guarantees the resulted approximation errors satisfy the desired accuracy. The good performance of TEAD in building global surrogate models is demonstrated in seven analytical functions with different dimensionality and complexity in comparison to two widely used experimental design methods. The application of the TEAD-based surrogate method in two groundwater models shows that the TEAD design can effectively improve the computational efficiency of GSA and UQ for groundwater modeling.

58 GEOSCIENCES↗

Solvent Additives: Key Morphology-Directing Agents for Solution-Processed Organic Solar Cells

By affecting film formation during the solution processing, solvent additives can provide fine control of the active layer morphology of organic photovoltaics. As such, solvent additives form a versatile method of experimental control for enhancing organic solar cell device performance. In this review, we provide a brief history of bulk heterojunction organic photovoltaics (OPV) processed from solution and the advent of solvent additives, putting them into context with other morphology directing agents. We present our current understanding of how solvent additives impact various mechanisms of phase separation, enabled by recent advances in morphology characterization by in situ X-ray scattering, absorbance and reflectometry. Indeed, understanding solvent additives’ effects on film formation has allowed them to be applied and combined effectively and synergistically to boost OPV performance. Their success as a morphology control strategy has also prompted the use of solvent additives in related organic semiconductor technologies. Finally, we discuss the role of solvent additives in the development of next-generation OPV active layers. In conclusion, despite concerns over their environmental toxicity and role in photo-instability, solvent additives will likely remain relevant morphological directing agents as research interests evolve toward non-fullerene acceptors, ternary blends and environmentally sustainable solvents.

36 MATERIALS SCIENCE↗

Single gold atoms stabilized on nanoscale metal oxide supports are catalytic active centers for various reactions

Key recent findings that demonstrate that single‐gold atom sites stabilized on various oxide supports by –O bonds are the unique catalytic sites for a number of reactions, including the water‐gas shift reaction, methanol partial oxidation and steam reforming reactions, and the selective dehydrogenation of ethanol are summarized herein. Atomic dispersion of gold on various metal oxides was followed with aberration‐corrected high angle annular dark field/scanning transmission microscopy imaging and x‐ray absorption spectroscopy (XANES/EXAFS). Gold nanoparticles and subnanometer clusters are active only through their interfacial atoms directly interacting with the support, hence if present, they entail precious metal waste. From a design perspective, the important feature in these supported catalysts is the creation of many single‐site gold species anchored on the oxide support to maximize activity. Atomic gold‐centered catalyst designs afford 100% atom efficiency, and more importantly, have distinct product selectivity, different from that of extended metal surfaces. Novel experimental synthesis methods of atomically dispersed Au catalysts are discussed, which pave the way for the efficient use of precious metals, broadening the application of properly designed gold and other precious metals (Pt, Pd) to different reactions in energy conversion and green chemicals production. © 2015 American Institute of Chemical Engineers AIChE J , 62: 429–439, 2016

Wang, Chongyang↗

Tailored Frequency Conversion in Nonlinear Subwavelength Grating Metaslabs

The use of metaslab waveguides consisting of subwavelength gratings (SWGs) is proposed as a highly flexible approach to obtain phase‐matched frequency conversion in nonlinear integrated devices. Control over the phase matching (PM) condition is achieved through modification of the linear modal propagation constants by the SWG. The method is experimentally demonstrated by fabrication of 0.4 mm‐long GaAs metaslabs designed for second harmonic generation of near‐infrared light. A controlled spectral shift of up to 100 nm in the PM condition, relative to a uniform slab is observed. Excellent agreement is found between the experimental results and finite‐difference eigenmode simulations, which predict a tunable frequency conversion bandwidth of ∼300 nm for the design parameters. The different regimes of PM control supported by the structure are discussed. This work highlights the potential of SWGs as building blocks for tailored frequency conversion in nonlinear integrated devices.

Form birefringence↗

Toward predictive permeabilities: Experimental measurements and multiscale simulation of methanol transport in Nafion

A polymer membrane's permeability to solutes determines its suitability for various applications: a permeability value is essential for predicting performance in diverse contexts. Using aqueous methanol permeation through Nafion as an example, we describe a methodology for determining membrane permeability that accounts for boundary layer effects and the possibility of swelling. For the materials and apparatus used herein, analysis of a permeance measurement and computational fluid dynamics simulations show that the mass transfer boundary layer is on the order of ones to tens of microns. Additionally, the data are used to develop and validate a multiscale model describing solute permeation through a hydrated membrane as a series of physical mechanistic steps: reversible adsorption from solution at the membrane interface, diffusion driven by a concentration gradient within the membrane, and reversible desorption into solution at the opposite membrane interface. The validated model is used to predict methanol transport across a solar-driven CO 2 reduction device and to assess the impact of polymer changes on the measured value. The approach of combining experimental data, computational fluid dynamics, and the mechanistic multiscale model is expected to provide more accurate analysis of membrane permeation data in cases with polymer swelling or unusual device geometries, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗